Kohler PRO 2.0 iS Owner's Manual

Page 1
OWNER’S MANUAL
Generator
PRO 2.0 iS
7PB-F8199-L2
Page 2
-
Read this manual carefully before operating this machine. This manual should
stay with this machine if it is sold.
Page 3
AE00002
INTRODUCTION
Congratulations on your purchase of your new Kohler. This manual will provide you with a good basic understanding of the operation and maintenance of this machine. If you have any questions regarding the operation or maintenance of your machine, please consult a Kohler portable dealer.
AE00022
© 2014 Reprinted by Kohler Co. under license.
Any reproduction or unauthorized use
the copyright holder is expressly prohibited.
PRO 2.0 iS
OWNER’S MANUAL
First edition, January 2014
All rights reserved.
without the written permission of
Printed in China.
KohlerPower.com33 590 03
Page 4
IMPORTANT MANUAL INFORMATION
Particularly important information is distin­guished in this manual by the following notations.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety mes­sages that follow this symbol to avoid possible injury or death.
WARNING
A WARNING indicates a hazardous sit­uation which, if not avoided, could result in death or serious injury.
NOTICE
A NOTICE indicates special precau­tions that must be taken to avoid dam­age to the machine or other property.
TIP
A TIP provides key information to make procedures easier or clearer.
AE00032
WARNING
PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THE MACHINE.
TIP
9 Kohler continually seeks advance-
ments in product design and quality. Therefore, while this manual contains the most current product information available at the time of printing, there may be minor discrepancies between your machine and this manual. If there is any question concerning this manual, please consult a Kohler por­table dealer.
9 This manual should be considered a
permanent part of this machine and should remain with this machine when resold.
* Product and specifications are subject to
change without notice.
KohlerPower.com 33 590 03
Page 5
AE00041
CONTENTS
SAFETY INFORMATION ....................... 1
Exhaust fumes are poisonous ............ 2
Fuel is highly flammable and
poisonous ............................................ 2
Engine and muffler may be hot ........... 2
Electric shock prevention .................... 3
Connection notes ................................ 4
Connection .......................................... 4
Extension cord notes .......................... 4
LOCATION OF IMPORTANT
LABELS ................................................. 5
DESCRIPTION ....................................... 7
Control panel ....................................... 7
CONTROL FUNCTION .......................... 8
Engine switch ...................................... 8
Recoil starter ....................................... 8
Oil warning light (Red) ........................ 8
DC protector ........................................ 9
Economy control switch ...................... 9
AC pilot light (Green) ........................ 10
Overload indicator light (Red) ........... 10
Fuel tank cap .................................... 10
Fuel tank cap air vent knob ............... 11
Fuel cock knob .................................. 11
Ground (earth) terminal .................... 11
Twin Tech .......................................... 12
PERIODIC MAINTENANCE ................ 27
Maintenance chart ............................ 27
Spark plug inspection ....................... 29
Carburetor adjustment ...................... 30
Engine oil replacement ..................... 30
Air filter .............................................. 32
Muffler screen and spark arrester ..... 33
Fuel tank filter ................................... 35
STORAGE ............................................ 36
Drain the fuel ..................................... 36
Engine ............................................... 38
TROUBLESHOOTING ......................... 39
SPECIFICATIONS ................................ 42
Dimensions ....................................... 42
Engine ............................................... 42
Generator .......................................... 42
CONSUMER INFORMATION .............. 43
Identification number records ............ 43
Machine identification ....................... 43
EXHAUST EMISSION CONTROL
SYSTEM AND COMPONENTS ........... 44
WIRING DIAGRAM .............................. 45
PREPARATION .................................... 13
Fuel ................................................... 13
Engine oil .......................................... 14
PRE-OPERATION CHECK .................. 16
Pre-operation check .......................... 16
OPERATION ........................................ 17
Starting the engine ............................ 17
Stopping the engine .......................... 19
Connection ........................................ 20
Battery charging ................................ 21
Operating range of DC power
supply ................................................ 24
Application range .............................. 25
High Altitude Operation .................... 26
KohlerPower.com33 590 03
Page 6
1
7DK-036
AE00071
SAFETY INFORMATION
9 This generator is not designed for on-board use.
Do not use it while installed on the vehicle.
9 Do not modify the generator or use it with its parts
removed.
9 Do not allow children to operate the generator.
9 Be sure to carry the generator only by its carrying
handle.
1 Carrying handle
9 Do not place any obstacles on the generator.
KohlerPower.com1 33 590 03
Page 7
7DK-001
AE00072
7DK-002
7DK-003
7DK-004
7DK-005
Exhaust fumes are poisonous
9 Using a generator indoors CAN KILL YOU IN
MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
9 NEVER use inside a home or garage, EVEN IF
doors and windows are open.
9 Only use OUTSIDE and far away from windows,
doors, and vents.
AE00075
Fuel is highly flammable and poisonous
9 Always turn off the engine when refuelling.
9 Never refuel while smoking or in the vicinity of an
open flame.
9 Take care not to spill any fuel on the engine or
muffler when refueling.
9 Do not leave the generator inside the vehicle or in
the trunk.
9 If you swallow any fuel, inhale fuel vapor, or allow
any to get in your eye(s), see your doctor immedi­ately. If any fuel spills on your skin or clothing, immediately wash with soap and water and change your clothes.
9 When operating or transporting the generator, be
sure it is kept upright. If it tilts, fuel may leak from the carburetor or fuel tank.
AE00843
Engine and muffler may be hot
9 Place the generator in a place where pedestrians
or children are not likely to touch the machine.
KohlerPower.com33 590 03 2
Page 8
1
7PB-011
7DK-008a
7DK-009
7DK-010
7DK-007
7DK-006
9 Avoid placing any flammable materials near the
exhaust outlet during operation.
9 In order to prevent overheating, ensure adequate
airflow by keeping the machine at least 1 m (3 ft) from objects or other equipment.
9 Do not operate the engine with a dust cover or
other objects covering it.
9 When covering the generator, be sure to do so
only after the engine and muffler have completely cooled down.
AE00083
Electric shock prevention
9 Never operate the engine in rain or snow.
9 Never touch the generator with wet hands or elec-
trical shock will occur.
9 Connect the Ground (earth) terminal to a ground
source. In order to prevent electrical shock, the generator must be grounded when using an elec­trical device with a ground plug.
1 Ground (earth) terminal
KohlerPower.com3 33 590 03
Page 9
7DK-012
1
2
1
2
AE00088
Connection notes
9 Avoid connecting the generator to commercial
power outlet.
9 Avoid connecting the generator in parallel with any
other generator.
1 Correct 2 Incorrect
AE00091
Connection
WARNING
Before the generator can be connected to a build­ing’s electrical system, a licensed electrician must install an isolation (transfer) switch in the build­ing’s main fuse box. The switch is the connection point for generator power and allows selection of generator or main line power to the building. This will prevent the generator from charging the main power line (backfeeding) when the main power supply has failed or has been turned off for line repair. Backfeeding can electrocute or injure line maintenance personnel. Also, generator and build­ing electrical system damage can occur when nor­mal operating power returns if unit is used without an isolation switch.
AE00086
Extension cord notes
Extension cords should be protected by a tough flexi­ble rubber sheath (IEC 245) or the equivalent to with­stand mechanical stresses.
KohlerPower.com33 590 03 4
Page 10
AE00062
1
2
7DK-013
3
4
5
6
7PB-014
LOCATION OF IMPORTANT LABELS
Please read the following labels carefully before oper­ating this machine.
TIP
Maintain or replace safety and instruction labels, as necessary.
1
KohlerPower.com5 33 590 03
Page 11
2
Hot parts can cause severe burns. Do not touch generator while operating or just after stopping.
Electrical shock can cause injury. Do not touch wires while generator is running. Do not connect generator to a building's electrical system unless using
an isolation (transfer) switch installed by a certified, licensed electrician.
Explosive Fuel can cause fires and severe burns. Do not fill fuel tank while generator is hot or running.
Las piezas calientes pueden causar quemaduras graves. No toque el generador durante el funcionamiento o inmediatamente después
de pararse.
La explosión del carburante puede provocar incendios y quemaduras graves. No llene el tanque de combustible mientras el generador esté caliente o
funcionando.
Las descargas eléctricas pueden provocar lesiones. No toque los cables con el generador en funcionamient.
No conecte el generador al sistema eléctrico de un edificio salvo que lo haga a través de un conmutador de aislamiento (transferencia) instalado por un electricista titulado autorizado.
7PB-F4162-20
3
5
4
6
KohlerPower.com33 590 03 6
Page 12
1
2
3
4
7DK-015
DESCRIPTION
1 2 3 4 5
6
7 8
9
0
q
w
7PB-017
5
6
7
7PB-016
1 Carrying handle 2 Fuel tank cap air vent knob 3 Fuel tank cap 4 Recoil starter 5 Fuel gauge 6 Muffler 7 Oil filler cap
AE00103
Control panel
1 Oil warning light 2 AC pilot light 3 Overload indicator light 4 Economy control switch
(Black)
5 Engine switch (Red) 6 Fuel cock knob 7 Choke knob 8 Twin Tech (parallel running
terminal)
9 AC receptacle 0 DC protector (breaker) q Ground (earth) terminal w DC receptacle
KohlerPower.com7 33 590 03
Page 13
1
2
7DK-018
1
700-115
AE00101
CONTROL FUNCTION
AE00121
Engine switch
The engine switch controls the ignition system.
17” (ON)
Ignition circuit is switched on. The engine can be started.
25” (STOP)
Ignition circuit is switched off. The engine will not run.
Recoil starter
The recoil starter is used to start the engine. Pull the recoil starter slowly until it is engaged, then pull it briskly.
1 Recoil starter handle
NOTICE
9 Pull the recoil starter handle straight. 9 Return the recoil starter handle slowly. 9 Do not touch the recoil starter handle while
the generator is operating.
AE00111
Oil warning light (Red)
When the oil level falls below the lower level, the oil warning light comes on and then the engine stops automatically. Unless you refill with oil, the engine will not start again.
TIP
If the engine stalls or does not start, turn the engine switch to “7” (ON) and then pull the recoil starter. If the oil warning light flickers for a few seconds, the engine oil is insufficient. Add oil and restart.
KohlerPower.com33 590 03 8
Page 14
1
2
7DK-020
DC protector
1
2
7PB-052
The DC protector turns to 3” (OFF) automatically when electric device being connected to the generator is operating and current above the rated flows. To use this equipment again, turn on the DC protector by pressing its button to
1 “I” (ON)
“I” (ON).
Direct current is output. (This is the default position.)
2 3” (OFF)
Direct current is not output.
NOTICE
Reduce the load of the connected electric device below the specified rated output of the generator if the DC protector turns off. If the DC protector turns off again, stop using the device immediately and consult a Kohler portable dealer.
AE00142
Economy control switch
1 “I” (ON)
When the economy control switch is turned to ON, the economy control unit controls the engine speed according to the connected load. The results are bet­ter fuel consumption and less noise.
23” (OFF)
When the economy control switch is turned to OFF, the engine runs at the rated r/min (4,500 r/min) regardless of whether is a load connected or not.
TIP
The economy control switch must be turned to OFF when using electric devices that require a large start­ing current, such as a compressor of a submersible pump.
KohlerPower.com9 33 590 03
Page 15
1
7DK-021
7DK-022
AC pilot light (Green)
1
7DK-048
The AC pilot light comes on when the engine starts and produces power.
1 AC pilot light
AE01087
Overload indicator light (Red)
The overload indicator light comes on when an over­load of a connected electrical device is detected, the inverter control unit overheats, or the AC output volt­age rises. Then, the AC protector will trip, stopping power generation in order to protect the generator and any connected electric devices. The AC pilot light (Green) will go off and the overload indicator light (Red) will stay on, but the engine will not stop running.
1 Overload indicator light
When the overload indicator light comes on and power generation stops, proceed as follows:
1. Turn off any connected electric devices and stop the engine.
2. Reduce the total wattage of connected electric devices within the rated output.
3. Check for blockages in the cooling air inlet and around the control unit. If any blockages are found, remove.
4. After checking, restart the engine.
TIP
The overload indicator light may come on for a few seconds at first when using electric devices that require a large starting current, such as a compressor or a submersible pump. However, this is not a mal­function.
Fuel tank cap
Remove the fuel tank cap by turning it counterclock­wise.
KohlerPower.com33 590 03 10
Page 16
1
2
7DK-023
2
1
7DK-024
1
7PB-011
Fuel tank cap air vent knob
The fuel tank cap is provided with an air vent knob to stop fuel flow. The air vent knob must be turned to ON. This will allow fuel to flow to the carburetor and the engine to run. When the engine is not in use, turn the air vent knob to OFF to stop fuel flow.
1 Air vent knob 2 Fuel tank cap
Fuel cock knob
The fuel cock supplies fuel from the fuel tank to the carburetor. The fuel cock has two positions.
1 ON
With the knob in this position, fuel flows to the carbu­retor. Normal using is done with the knob in this posi­tion.
2 OFF
With the knob in this position, fuel will not flow. Always turn the knob to this position when the engine is not running.
Ground (earth) terminal
Ground (earth) terminal connects the earth line for prevention of electric shock. When the electric device is grounded, be sure to ground the generator also.
1 Ground (earth) terminal
KohlerPower.com11 33 590 03
Page 17
7DK-042a
Twin Tech (Terminal for connecting special cables for parallel running)
This is the terminal for connecting special cables for parallel running of two PRO 2.0 iS. The parallel run­ning requires two PRO 2.0 iS and the special cables. (The rated output in parallel running is 3.0 kVA and the rated current is 25.0 A.) The handling, operation procedure and the notes on usage are described in the Parallel Power Cable Kit owner’s manual included in the Parallel Power Cable Kit. Consult a Kohler portable dealer for this Parallel Power Cable Kit.
KohlerPower.com33 590 03 12
Page 18
3
4
7DK-037
7DK-091
1
2
7DK-028
707-095
PREPARATION
WARNING
AE00856
Fuel
9 Fuel is highly flammable and poisonous.
Check “SAFETY INFORMATION” (See page 2) carefully before filling.
9 Do not overfill the fuel tank, otherwise it may
overflow when the fuel warms up and expands.
9 After fill the fuel, make sure the fuel tank cap
is tightened securely.
1. Stop the engine.
2. Place the generator on a level surface.
3. Remove the fuel tank cap.
4. Check the fuel level.
5. If low, fill the tank with fuel.
NOTICE
9 Immediately wipe off spilled fuel with a clean,
dry, soft cloth, since fuel may deteriorate painted surfaces or plastic parts.
9 Use only unleaded gasoline. The use of leaded
gasoline will cause severe damage to internal engine parts.
Make sure there is sufficient fuel in the tank. When refueling, be sure to fill the tank up to the “LEVEL” (red) mark of the fuel tank filter.
1 Fuel level 2 Fuel tank filter 3 Fuel level gauge 4 “LEVEL” (red) mark
KohlerPower.com13 33 590 03
Page 19
2
7PB-031
1
7PB-030
5
6
7DK-093
Recommended fuel: Unleaded gasoline Fuel tank capacity: Total:
4.2 L (1.11 US gal, 0.92 Imp gal)
5 6
“F” “E”
Full
Empty
Your Kohler engine has been designed to use regular unleaded gasoline with a pump octane number ((R + M)/2) of 86 or higher, or research octane number of 91 or higher.
AE00222
Engine oil
NOTICE
The generator has been shipped without engine oil. Do not start the engine until you have filled it with the sufficient engine oil.
1. Place the generator on a level surface.
2. Remove the panel.
1 Panel
3. Remove the oil filler cap.
2 Oil filler cap
KohlerPower.com33 590 03 14
Page 20
700-119
3
4. Fill the specified amount of the recommended
0˚C
å
Kohler 10W-30
SAE 10W
ç
SAE #20
SAE #30
32˚F
25˚C
80˚F
engine oil, and then install and tighten the oil filler cap.
NOTICE
7PB-033
9 Do not tilt the generator when adding engine
oil. This could result in overfilling and damage to the engine.
9 Be sure no foreign material enters the crank-
case.
3 Correct level
Recommended engine oil:
å
Kohler 10W-30,
SAE 10W-30 or 10W-40
SAE #30
ç
SAE #20
SAE 10W Recommended engine oil grade: API Service SE type or higher Engine oil quantity:
0.4 L (0.42 US qt, 0.35 Imp qt)
5. Install the panel.
KohlerPower.com15 33 590 03
Page 21
AE00845
WARNING
PRE-OPERATION CHECK
If any item in the Pre-operation check is not work­ing properly, have it inspected and repaired before operating the generator.
The condition of a generator is the owner’s responsi­bility. Vital components can start to deteriorate quickly and unexpectedly, even if the generator is unused.
TIP
Pre-operation checks should be made each time the generator is used.
Pre-operation check
Fuel (See page 13)
9 Check fuel level in fuel tank. 9 Refuel if necessary.
Fuel line
9 Check fuel hose for crack or damage. 9 Replace if necessary.
Engine oil (See page 14)
9 Check oil level in engine. 9 If necessary, add recommended oil to specified
level.
9 Check generator for oil leakage.
The point where abnormality was recognized by use
9 Check operation. 9 If necessary, consult a Kohler portable dealer.
KohlerPower.com33 590 03 16
Page 22
7PB-047
3
7DK-038
AE00846
WARNING
1
7DK-034
2
7DK-035
OPERATION
9 Never operate the engine in a closed area or it
may cause unconsciousness and death within a short time. Operate the engine in a well ven­tilated area.
9 Before starting the engine, do not connect any
electric devices.
9 Clean dusts, dirt or water off the receptacle
before use.
NOTICE
The generator has been shipped without engine oil. Do not start the engine until you have filled it with the sufficient engine oil.
Starting the engine
1. Turn the economy control switch (Black) to “3
(OFF).
13” (OFF)
2. While holding the fuel tank cap so that it will not move, turn the air vent knob to ON.
2 ON
3. Turn the fuel cock knob to ON.
3 ON
KohlerPower.com17 33 590 03
Page 23
7DK-041
5
7DK-040
4
7DK-039
4. Turn the engine switch (Red) to “7” (ON).
WARNING
47” (ON)
5. Pull the choke knob fully out.
5 Choke knob
TIP
The choke is not required to start a warm engine. Push the choke knob in to the original position.
6. Pull the recoil starter slowly until it is engaged, then pull it briskly.
Be careful to use the recoil starter. In rare cases, the recoil starter handle can be drawn back quick­ly by the engine kickback.
TIP
Grasp the carrying handle firmly to prevent the gener­ator from falling over when pulling the recoil starter.
KohlerPower.com33 590 03 18
Page 24
1
7DK-034
7PB-047
2
7DK-044
6
7PB-042
7. After the engine starts, warm up the engine until the engine does not stop when the choke knob is returned to the original position.
6 Original position
TIP
When starting the engine, with the economy control switch ON, and there is no load on the generator: 9 in ambient temperature below 0 °C (32 °F), the
engine will run at the rated r/min (4,500 r/min) for 5 minutes to warm up the engine.
9 in ambient temperature below 5 °C (41 °F), the
engine will run at the 4,500 r/min for 3 minutes to warm up the engine.
The economy control unit operates normally after the above time period, while the economy control switch is ON.
AE01025
Stopping the engine
1. Turn off any electric devices.
2. Turn the economy control switch (Black) to “3” (OFF).
13” (OFF)
3. Disconnect any electric devices.
4. Turn the engine switch (Red) to “5” (STOP).
25” (STOP)
KohlerPower.com19 33 590 03
Page 25
WARNING
3
7DK-045
4
7DK-092
5. Turn the fuel cock knob to OFF.
3 OFF
6. Turn the fuel tank cap air vent knob to OFF after the engine has completely cooled down.
4 OFF
AE00839
Connection
Alternating Current (AC)
Be sure any electric devices are turned off before plugging them in.
NOTICE
9 Be sure all electric devices including the lines
and plug connections are in good condition before connection to the generator.
9 Be sure the total load is within generator rated
output.
9 Be sure the receptacle load current is within
receptacle rated current.
TIP
Make sure to ground (earth) the generator. When the electric device is grounded, be sure to ground the generator also.
KohlerPower.com33 590 03 20
Page 26
2
7DK-049
1
7DK-048
1. Start the engine.
7PB-043
2. Plug in to AC receptacle.
3. Make sure the AC pilot light is on.
1 AC pilot light
4. Turn the economy control switch to “I” (ON).
2 “I” (ON)
5. Turn on any electric devises.
TIP
The economy control switch must be turned to “3” (OFF) to increase engine speed to rated r/min.
Battery charging
NOTICE
Do not connect a VRLA (Valve Regulated Lead Acid) battery. To charge a VRLA battery, a special (constant-voltage) battery charger is required.
TIP
9 The generator DC rated voltage is 12 V. 9 Start the engine first, and then connect the gener-
ator to the battery for charging.
9 Before starting to charge the battery, make sure
that the DC protector is turned on.
KohlerPower.com21 33 590 03
Page 27
762-040
1
2
6v 6v
12v
762-041
1. Start the engine.
2. Connect the red battery charger lead to the posi­tive (+) battery terminal.
1 Red battery charger lead 2 Black battery charger lead
3. Connect the black battery charger lead to the negative (–) battery terminal.
4. Turn the economy control switch “3” (OFF) to start battery charging.
NOTICE
9 Be sure the economy control switch is turned
off while charging the battery.
9 Be sure to connect the red battery charger
lead to the positive (+) battery terminal, and connect the black lead to the negative (–) bat­tery terminal. Do not reverse these positions.
9 Connect the battery charger leads to the bat-
tery terminals securely so that they are not disconnected due to engine vibration or other disturbances.
9 Charge the battery in the correct procedure by
following instructions in the owner’s manual for the battery.
9 The DC protector turns
cally if current above the rated flows during battery charging.
To restart charging the battery, turn the DC
protector on by pressing its button to (ON). If the DC protector turns off again, stop charging the battery immediately and consult a Kohler portable dealer.
3” (OFF) automati-
“I”
KohlerPower.com33 590 03 22
Page 28
WARNING
3 “I” (ON)
3
4
7PB-052
4 3” (OFF)
TIP
9 Follow instructions in the owner’s manual for the
battery to determine the end of battery charging.
9 Measure the specific gravity of electrolyte to
determine if the battery is fully charged. At full charge, the electrolyte specific gravity is between
1.26 and 1.28.
9 It is advisable to check the specific gravity of the
electrolyte at least once every hour to prevent overcharging the battery.
Never smoke or make and break connections at the battery while charging. Sparks may ignite the battery gas. Battery electrolyte is poisonous and dangerous, causing severe burns, etc. contains sulfuric (sul­phuric) acid. Avoid contact with skin, eyes or clothing. Antidote: EXTERNAL-Flush with water. INTERNAL-Drink large quantities of water or milk. Follow with milk of magnesia, beaten egg or vege­table oil. Call physician immediately. EYES: Flush with water for 15 minutes and get prompt medical attention. Batteries produce explo­sive gases. Keep sparks, flame, cigarettes, etc., away. Ventilate when charging or using in closed space. Always cover eyes when working near bat­teries. KEEP OUT OF REACH OF CHILDREN.
KohlerPower.com23 33 590 03
Page 29
Operating range of DC power supply (exclusively for charging 12 V battery)
This power source is designed to charge batteries up to 40 Ah that are half-discharged. Do not charge bat­teries of a higher capacity than 40 Ah.
12 V battery
The time required for recharging a battery varies depending on the discharge level of the battery. When the specific gravity of the battery reaches 1.26 to 1.28, charging is complete. When charging, check the bat­tery’s specific gravity once an hour. The average time for charging a half-discharged 40 Ah battery is approximately 5 hours. Be sure to check the battery fluid level before charging.
NOTICE
9 Do not connect any load to the battery or use
the engine starter motor while charging. This causes high current to flow through the gener­ator which will burn out the coil.
9 Do not connect a VRLA (Valve Regulated Lead
Acid) battery. To charge a VRLA battery, a spe­cial (constant-voltage) battery charger is required.
KohlerPower.com33 590 03 24
Page 30
AE00812
1
7DK-021
Application range
When using the generator, make sure the total load is within rated output of a genera­tor. Otherwise, generator damage may occur.
AC
Power factor 1 0.8–0.95
PRO 2.0 iS –1,600 W –1,280 W –544 W
0.4–0.75
(Efficiency 0.85)
TIP
9 “–” means below. 9 Application wattage indicates when each device is
used by itself.
9 The simultaneous usage of AC and DC power is
possible but total wattage should not exceed the rated output.
EX:
Generator rated output 1,600 VA
Frequency Power factor
AC
1.0 –1,500 W
0.8 –1,180 W
DC
Rated voltage
12 V
Rated current
8 A
DC
96 W
(12 V/8 A)
9 The overload indicator light comes on when total
wattage exceeds the application range. (See page 10 for more details.)
1 Overload indicator light
NOTICE
9 Do not overload. The total load of all electrical appliances must not exceed
the supply range of the generator. Overloading will damage the generator.
9 When supplying precision equipment, electronic controllers, PCs, electronic
computers, microcomputer-based equipment or battery chargers, keep the generator a sufficient distance away to prevent electrical interference from the engine. Also ensure that electrical noise from the engine does not inter­fere with any other electrical devices located near the generator.
9 If the generator is to supply medical equipment, advice should first be
obtained from the manufacturer, a medical professional or hospital.
9 Some electrical appliances or general-purpose electric motors have high starting
currents, and cannot therefore be used, even if they lie within the supply ranges given in the above table. Consult the equipment manufacturer for further advice.
KohlerPower.com25 33 590 03
Page 31
High Altitude Operation
This engine may require a high altitude carburetor kit to ensure correct engine opera­tion at altitudes above 4000 ft. (1219 meters). If you operate your engine at altitudes above 4000 ft. (1219 meters) consistently, have your local Kohler portable dealer per­form the necessary carburetor modification. This engine should be operated in its origi­nal configuration below 4000 ft. (1219 meters) as damage may occur if high altitude carburetor kit is installed and operated below 4000 ft. (1219 meters).
KohlerPower.com33 590 03 26
Page 32
AE00401
WARNING
WARNING
PERIODIC MAINTENANCE
Safety is an obligation of the owner. Periodic inspection, adjustment and lubrication will keep your generator in the safest and most efficient condition possible. The most impor­tant points of generator inspection, adjustment, and lubrication are explained on the fol­lowing pages.
If you are not familiar with maintenance work, have a Kohler portable dealer do it for you.
AE00403
Maintenance chart
Stop the engine before starting maintenance work.
NOTICE
Use only Kohler specified genuine parts for replacement. Ask an authorized Kohler portable dealer for further information.
Item Routine
Spark plug
Fuel • Check fuel level and leakage.
Fuel hose
Engine oil
Air filter element
Muffler screen
Spark arrester
Fuel tank filter • Clean and replace if necessary.
• Check condition.
• Clean and replace if necessary.
• Check fuel hose for cracks or damage. Replace if necessary.
• Check oil level in engine.
• Replace.
• Check condition.
• Clean.
• Check condition.
• Clean and replace if necessary.
• Check condition.
• Clean and replace if necessary.
Pre-
operation
check
2
2
2
Every
6 months or 100 Hr
2
(*1)
2
(*2)
2
2
2
12 months
or 300 Hr
2
KohlerPower.com27 33 590 03
Page 33
Item Routine
Pre-
operation
check
Every
6 months or 100 Hr
12 months
or 300 Hr
Crankcase breather hose
Cylinder head
• Check breather hose for cracks or damage.
• Replace if necessary.
• Decarbonize cylinder head.
• More frequently if necessary.
After every 500 Hrs.
Valve clearance • Check and adjust valve clearance.
Idle speed • Check and adjust idle speed.
Recoil starter • Check recoil starter for damage.
Fittings / fasteners
The point where abnormality was recognized by use.
....
*1
Initial replacement of the engine oil is after one month or 20 hours of operation.
....
*2
The air filter element needs to be cleaned more frequently when using in unusually wet or
• Check all fittings and fasteners.
• Correct if necessary.
2
dusty areas.
.....
Since these items require special tools, data and technical skills, have a Kohler portable deal­er perform the service.
2
KohlerPower.com33 590 03 28
Page 34
4
3
7DK-053
5
6
7DK-054
a
760-001a
Spark plug inspection
1
2
7PB-030
The spark plug is an important engine component, which should be checked periodically.
1. Remove the screws, and then remove the cover.
1 Screw 2 Cover
2. Remove the spark plug cap and cap, and insert the tool through the hole from the outside of the cover.
3 Spark plug cap 4 Cap
3. Insert the handlebar into the tool and turn it coun­terclockwise to remove the spark plug.
5 Tool 6 Handlebar
4. Check for discoloration and remove the carbon.
The porcelain insulator around the center elec-
trode of spark plug should be a medium-to-light tan color.
5. Check the spark plug type and gap.
a Spark plug gap
Standard spark plug: 33 132 02-S (Kohler) Spark plug gap:
0.6–0.7 mm (0.024–0.028 in)
TIP
The spark plug gap should be measured with a wire thickness gauge and, if necessary, adjusted to specifi­cation.
KohlerPower.com29 33 590 03
Page 35
6. Install the spark plug.
1
2
7PB-030
WARNING
Spark plug tightening torque: 20 Nm (2.0 m·kgf, 14 ft·lbf)
TIP
If a torque wrench is not available when installing a spark plug, a good estimate of the correct torque is 1/4–1/2 turn past finger tight. However, the spark plug should be tightened to the specified torque as soon as possible.
7. Install the spark plug cap and cap.
8. Install the cover and tighten the screws.
AE00431
Carburetor adjustment
The carburetor is a vital part of the engine. Adjusting should be left to a Kohler portable dealer with the pro­fessional knowledge, specialized data, and equipment to do so properly.
AE00412
Engine oil replacement
Avoid draining the engine oil immediately after stopping the engine. The oil is hot and should be handled with care to avoid burns.
1. Place the generator on a level surface and warm up the engine for several minutes.
Then stop the engine and turn the fuel cock knob,
fuel tank cap air vent knob to OFF.
2. Remove the screws and then remove the cover.
1 Screw 2 Cover
KohlerPower.com33 590 03 30
Page 36
7DK-031
3
4
7DK-055
7DK-033
700-006a
5
0˚C
å
Kohler 10W-30
SAE 10W
ç
SAE #20
SAE #30
32˚F
25˚C
80˚F
3. Remove the oil filler cap.
3 Oil filler cap 4 O-ring
4. Place an oil pan under the engine. Tilt the genera­tor to drain the oil completely.
5. Check the oil filler cap and O-ring. Replace them if damaged.
6. Place the generator on a level surface.
7. Add engine oil to the correct level.
NOTICE
9 Do not tilt the generator when adding engine
oil. This could result in overfilling and damage to the engine.
9 Be sure no foreign material enters the crank-
case.
5 Correct level
Recommended engine oil:
å Kohler 10W-30,
SAE 10W-30 or 10W-40
SAE #30
ç
SAE #20
SAE 10W Recommended engine oil grade: API Service SE type or higher Engine oil quantity:
0.4 L (0.42 US qt, 0.35 Imp qt)
8. Wipe the cover clean, and wipe up any spilled oil.
KohlerPower.com31 33 590 03
Page 37
1
2
7PB-030
3
4
7DK-061
WARNING
7DK-062
7
5
6
9. Install the O-ring and the oil filler cap.
6
7
7PB-030
10. Install the cover and tighten the screws.
6 Screw 7 Cover
AE01084
Air filter
1. Remove the screws, and then remove the cover.
1 Screw 2 Cover
2. Remove the screw and then remove the air filter case cover.
3 Screw 4 Air filter case cover
3. Remove the foam element.
5 Screw 6 Air filter case cover 7 Foam element
4. Wash the foam element in solvent and dry it.
Never use solvent while smoking or in the vicinity of an open flame.
5. Oil the foam element and squeeze out excess oil. The foam element should be wet but not dripping.
NOTICE
Do not wring out the foam element when squeez­ing it. This could cause it to tear.
KohlerPower.com33 590 03 32
Page 38
7DK-026
1
2
1
7PB-066
WARNING
Recommended oil: Foam-air-filter oil or engine oil (See page 15)
6. Insert the foam element into the air filter case.
NOTICE
The engine should never run without the foam ele­ment; excessive piston and cylinder wear may result.
TIP
Be sure the foam element sealing surface matches the air filter so there is no air leak.
7. Install the air filter case cover in its original posi­tion and tighten the screw.
8. Install the cover and tighten the screws.
AE01075
Muffler screen and spark arrester
The engine and muffler will be very hot after the engine has been run. Avoid touching the engine and muffler while they are still hot with any part of your body or clothing during inspection or repair.
1. Remove the muffler cover screws, and then remove the muffler cover.
1 Muffler cover screw 2 Muffler cover
KohlerPower.com33 33 590 03
Page 39
8
7
7DK-065a
711-075
3
4
5
7DK-063
7DK-064
6
7DK-065
2. Loosen the muffler cap bolt and then remove the muffler cap and muffler screen.
3 Muffler cap bolt 4 Muffler cap 5 Muffler screen
3. Use a flathead screw driver to pry the spark arrester out from the muffler.
4. Remove the spark arrester.
6 Spark arrester
5. Remove the carbon deposits on the muffler cap, muffler screen and spark arrester using a wire brush.
NOTICE
When cleaning, use the wire brush lightly to avoid damaging or scratching of the muffler cap, muffler screen and spark arrester.
6. Check the muffler screen and spark arrester.
Replace them if damaged.
7. Install the spark arrester.
TIP
Align the spark arrester projection to the hole in the muffler pipe.
7 Spark arrester projection 8 Hole
KohlerPower.com33 590 03 34
Page 40
7DK-068
8. Install the muffler screen and muffler cap, and
2
1
7PB-069
WARNING
WARNING
then tighten the muffler cap bolt.
Muffler cap bolt tightening torque:
3.5 Nm (0.35 m·kgf, 2.5 ft·lbf)
9. Install the muffler cover and tighten the muffler cover screws.
AE00471
Fuel tank filter
Never use gasoline while smoking or in the vicini­ty of an open flame.
1. Remove the fuel tank cap and fuel tank filter.
1 Fuel tank cap 2 Fuel tank filter
2. Clean the fuel tank filter with gasoline.
Replace it if damaged.
3. Wipe the fuel tank filter and insert it.
4. Install the fuel tank cap.
Be sure the fuel tank cap is tightened securely.
KohlerPower.com35 33 590 03
Page 41
AE00601
WARNING
1
7DK-044
2
7DK-039
STORAGE
Long term storage of your machine will require some preventive procedures to guard against deterioration.
AE01056
Drain the fuel
1. Turn the engine switch to “5” (STOP).
15” (STOP)
2. Remove the fuel tank cap and fuel tank filter. Extract the fuel from the fuel tank into an approved gasoline container using a commercially available hand siphon. Then, install the fuel tank filter and fuel tank cap.
Fuel is highly flammable and poisonous. Check “SAFETY INFORMATION” (See page 2) carefully.
NOTICE
Immediately wipe off spilled fuel with a clean, dry, soft cloth, since fuel may deteriorate painted sur­faces or plastic parts.
3. Turn the engine switch to “7” (ON).
27” (ON)
KohlerPower.com33 590 03 36
Page 42
4. Turn the fuel tank cap air vent knob and fuel cock
3
7DK-035
4
7DK-038
5
6
7PB-030
7
7DK-071
knob to ON.
3 ON 4 ON
5. Start the engine and leave it run until it stops.
The engine stops in approximately 20 minutes
time by running out of fuel.
TIP
9 Do not connect with any electrical devices.
(unloaded operation)
9 Duration of the running engine depends on the
amount of the fuel left in the tank.
6. Remove the screws, and then remove the cover.
5 Screw 6 Cover
7. Drain the fuel remaining in the carburetor into an approved container by loosening the drain screw on the carburetor float chamber.
7 Drain screw
8. Tighten the drain screw.
9. Turn the engine switch to “5” (STOP).
10. Turn the fuel cock knob to OFF.
11. Install the cover and tighten the screws.
12. Turn the fuel tank cap air vent knob to OFF after the engine has completely cooled down.
13. Tighten further if any screws, bolts and nuts are loose.
14. Store the generator in a dry, well-ventilated place, with the cover placed over it.
KohlerPower.com37 33 590 03
Page 43
Engine
7DK-072
Perform the following steps to protect the cylinder, pis­ton ring, etc. from corrosion.
1. Remove the spark plug, pour about one table­spoon of engine oil (See page 15) into the spark plug hole and install the spark plug. Recoil start the engine by turning over several times (with igni­tion off) to coat the cylinder walls with oil.
2. Pull the recoil starter until you feel compression. Then stop pulling. (This prevents the cylinder and valves from rusting).
3. Clean exterior of the generator and apply a rust inhibitor.
4. Store the generator in a dry, well-ventilated place, with the cover placed over it.
5. The generator must remain in a vertical position when stored, carried or operated.
KohlerPower.com33 590 03 38
Page 44
7DK-091
1
7DK-035
2
7DK-038
700-006
AE00512
TROUBLESHOOTING
Engine won’t start
1. Fuel systems
No fuel supplied to combustion chamber.
2 No fuel in tank .... Supply fuel.
2 Fuel in tank .... Fuel tank cap air vent knob and
fuel cock knob to ON.
1 ON 2 ON
2 Clogged fuel line .... Clean fuel line.
2 Clogged carburetor .... Clean carburetor.
2. Engine oil system
Insufficient
2 Oil level is low .... Add engine oil.
KohlerPower.com39 33 590 03
Page 45
1
2
7PB-052
7DK-041
791-001d
3. Electrical systems
3
7DK-039
2 Engine switch to “7” (ON) and pull the recoil
starter.
37” (ON)
Poor spark
2 Spark plug dirty with carbon or wet .... Remove
carbon or wipe spark plug dry.
2 Faulty ignition system .... Consult a Kohler porta-
ble dealer.
AE00515
Generator won’t produce power
2 Safety device (DC protector) to OFF ···· Press the
DC protector to ON.
1 “I” (ON) 2 3” (OFF)
2 Safety device (AC) to OFF .... Stop the engine,
then restart.
KohlerPower.com33 590 03 40
Page 46
AE00515
WARNING
A ENGINE DOES NOT START
B
Turn the engine switch to “7” (ON), then pull the recoil starter and check if the oil warning light flickers.
C Does not flicker D Flickers
H
Pull the recoil starter and check the spark plug for spark strength. (See “WARNING”)
E Check engine oil level.
F OK G Level low
Consult a Kohler portable
Add engine oil.
dealer.
9 To prevent FIRE HAZARDS be
sure fuel is not present in the spark plug area.
9 To prevent FIRE HAZARDS be
sure to place the spark plug as far away as possible from the spark plug hole and carburetor area.
9 To prevent ELECTRIC SHOCK do
not hold spark plug lead with hand while testing.
I OK J Does not spark
Check the following.
N
9 Fuel line clogging
O Clogged
9 Ai r f ilter e l e ment
clogging.
P OK
K Check the spark plug.
9 Type: 33 132 02-S 9 Gap: 0.6–0.7 mm (0.024–0.028 in)
L Incorrect M OK
Replace or adjust gap.
Q
Clean
R OK
Clean the spark plug.
or
replace.
S Engine does not start.
T Consult a Kohler portable dealer.
KohlerPower.com41 33 590 03
Page 47
AE00701
SPECIFICATIONS
AE00702
Dimensions
Unit PRO 2.0 iS Overall length mm (in) 490 (19.3) Overall width mm (in) 280 (11.0) Overall height mm (in) 445 (17.5) Dry weight kg (lb) 20 (44)
AE00704
Engine
Unit PRO 2.0 iS Type Cylinder arrangement Displacement Bore × Stroke Operation hours
3
cm
mm (in) 48.6 × 43.0 (1.91 × 1.69)
Hr 4.2–10.5 (rated load–1/4 load) Fuel Fuel tank capacity Engine oil quantity
L (US gal, Imp gal) 4.2 (1.11, 0.92)
L (US qt, Imp qt) 0.4 (0.42, 0.35) Ignition system Spark plug: Type Gap Noise level*
mm (in) 0.6–0.7 (0.024–0.028)
WA 89
dB / L
dB (A) / 7 m 51.5–61
* : Noise level is measured when the economy control switch is turned to ON. L
WA shows the sound power level under the ISO3744 satisfied test conditions.
The noise level in “dB (A) / 7 m” is the arithmetic mean value in four directions measured 7
meters away from each side of the generator.
The noise level may vary in different environments.
Air cooled 4-stroke gasoline OHV
Inclined, 1 cylinder
79
Unleaded gasoline
CDI
33 132 02-S (Kohler)
AE00707
Generator
AC Output
Rated voltage V 120 Rated frequency Hz 60 Rated current A 13.3 Rated output kVA 1.6
Safety device: Type Electronic DC Output
Rated voltage V 12 Rated current A 8
Safety device: Type DC protector
Unit PRO 2.0 iS
KohlerPower.com33 590 03 42
Page 48
Serial No. Spec. No. PA-PRO 2.0 iS-3001
7PB-XXXXXX
7PB-073
1
CONSUMER INFORMATION
SERIAL NUMBER:
MODEL
SERIAL No.
AE00012
Identification number records
Record your serial number in the spaces provided, to assist you in ordering spare parts from a Kohler portable dealer. Also record and keep the serial number in a separate place in case your machine is stolen.
AE00011
Machine identification
The machine serial number is stamped in the location as shown.
1 Machine serial number
TIP
Keep a record of serial number for refer­ence when ordering parts from a Kohler portable dealer.
KohlerPower.com43 33 590 03
Page 49
AE00789
EXHAUST EMISSION CONTROL SYSTEM AND COMPONENTS
Item Acronym
9 CARB. ASSY., LH. & JT., .......................CARB (Carburetor)
CARBURETOR2
9 T.C.I. MAGNETO ASSY. & ..................... EI (Electronic Ignition)
PLUG, SPARK
9 CRANKCASE1 & HEAD, .......................PCV (Positive Crankcase
CYLINDER1 Ventilation)
9 AIR FILTER ASSY. . ................................ACL (Air Cleaner)
9 MUFF., 2, CAP, NET, WIRE2 & ARRESTER, SPARK
The above items and the corresponding acronyms are provided in accordance with U.S. EPA REGULATIONS FOR NEW NONROAD SPARK-IGNITION NONHANDHELD ENGINES and the CALIFORNIA REGULATIONS FOR 1995 AND LATER SMALL OFF­ROAD ENGINES. The acronyms conform to the latest version of the SAE’s recommended practice docu­ment J1930, “Diagnostic Acronyms, Terms, and Definitions For Electrical/Electronic System”.
It is recommended that these items be serviced by a Kohler portable dealer.
KohlerPower.com33 590 03 44
Page 50
W
Br
R
R
Br
R
Br
R
Br
R
Br
R
Br
Br
B
B
B
B
B
B B
B
B
B
Y
Y
O
O
O
Y
Br
G
R
G
Br
R
Y
Y
Y
R
R R
R
R
L
L
L
L
L
L
L
L
L
G
G
Y
Y
O
O
O
O
O
OLO
O
B/W
B/W
R/W
Br
BrBr
R/W R/W R/W
G/Y
G/Y
O
G/Y
2
1
3
u
o
i
p
4
5
6
7
8
9
q
0
e
w
r
y
t
7DK-10
AE00751
WIRING DIAGRAM
1 Sub coil 2 DC coil 3 Main coil 4 DC rectifier 5 DC protector (breaker) 6 Twin Tech (parallel
7 DC receptacle
running terminal)
8 AC pilot light 9 AC receptacle 0 Economy control switch q Overload indicator light w Engine switch e Oil warning light r Ground (earth) terminal t Control unit y CDI unit/Ignition coil u Stepping motor i Spark plug o CDI magneto
p Oil level gauge
Color code
B Black Br Brown G Green L Blue O Orange R Red W White Y Yellow B/W Black/White G/Y Green/Yellow R/W Red/White
KohlerPower.com45 33 590 03
Page 51
Page 52
OWNER’S MANUAL
PRINTED IN CHINA
2014.01 !
(E)
Loading...