Features
•
Fixture-mount design.
Material
•
Durable brass construction.
•
Chloramine resistance on all rubber components exposed to
waterway.
Technology
•
Non-hold open piston technology for accurate activation.
Installation
•
Intended for urinal installations with 3/4" top spud coupling
connection.
•
Includes vacuum breaker and control stop.
•
Self-cleaning brass piston prevents clogging and reduces
maintenance.
Recommended Products/Accessories
K-23723 Faucet cleaner
Manual 0.5 GPF Urinal Flushometer
K-76318
Codes/Standards
ASSE 1037/ASME A112.1037/CSA B125.37
EPA WaterSense
ADA
ICC/ANSI A117.1
CSA B651
OBC
®
KOHLER® One-Year Limited Warranty
See website for detailed warranty information.
Available Colors/Finishes
Color tiles intended for reference only.
DescriptionCodeColor
Polished ChromeCP
1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
7-11-2020 23:31 - US/CA/MX

1-9/16"
(40 mm)
4-3/8" (111 mm) Min
5" (127 mm) Max
Ø 2-3/4"
(70 mm)
*12"
(307 mm)
Ø 3" (76 mm)
1"
(25 mm)
2-1/4" (57 mm) Min
5" (127 mm) Max
3/4"-14 NPT Supply
13-3/16"
(335 mm)
Max
*10-3/4" (273 mm) minimum with a
6" (152 mm) critical level above the fixture
6"
(152 mm)
Min
5/8"
(16 mm)
Ø 3/4"
(19 mm)
Manual 0.5 GPF Urinal Flushometer
K-76318
Technical Information
All product dimensions are nominal.
80 psi (551.6 kPa)Fixture pressure max
(static):
Pressure and Supply Requirements
(static):
25 psi (172.4 kPa)Fixture pressure min
Fixture Supply Requirements
25 psi (172.4 kPa)Min static pressure:
80 psi (551.6 kPa)Max static pressure:
25 psi (172.4 kPa)Min flowing pressure:
9 gpm (34.1 lpm)Min flow rate:
1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
7-11-2020 23:31 - US/CA/MX
Notes
Install this product according to the installation
guide.
ADA, OBC, CSA B651 compliant when installed
to the specific requirements of these regulations.