Kohler KOH8335 Installation and & Assembly

Roughing-In
K-1139-H, K-1139-LH, K-1139-RH
PROFLEX
®
6036
WHIRLPOOL BATH WITH HEATER
Product Information
Applicable products: Whirlpool bath with heater - drop-in (shown) K-1139-H Whirlpool bath with heater - left drain hole,
tile flange Whirlpool bath with heater - right drain hole,
tile flange
Drop-in cutout 58-1/2(1486 mm) x 34-1/2(876 mm)
Pump: V Hz A 1-speed 120 60 7.5
K-1139-LH
K-1139-RH
Heater: kW V Hz A
1.5 120 60 12.5
Required Electrical Service
Two dedicated circuits required, each protected with Class A Ground-Fault Circuit-Interrupter (GFCI):
Pump/control 120 V, 15 A, 60 Hz Heater 120 V, 15 A, 60 Hz Locate the outlets behind the whirlpool and within 24
(610 mm) of the pump.
Installation Notes
Install this product according to the installation guide.
Floor support under whirlpool must provide for a minimum of 37 lbs/square foot (183 kg/square meter) loading.
The apron must be installed before the finished floor and wall materials are installed.
Fixture conforms to CSA B45.5/IAPMO Z124. All dimensions are nominal.
18" (457 mm)
1" (25 mm)
2-1/2" (64 mm)
3" (76 mm)
8" (203 mm)
60" (1524 mm)
2-7/8" (73 mm)
3/8" (10 mm)
Lumbar Angle 29˚
18-1/8"
(460 mm)
No change in measurements if connected with drain illustrated. (K-11677)
1-1/4" (32 mm)
Pump/Control Access (If Apron Is Not Used) 20" (508 mm) W x 15" (381 mm) H
Tile Flange
Detail
36" (914 mm)
1-1/2" (38 mm)
16-5/8"
(422 mm)
Drop-in Rim
1-1/2" Bath Drain
Detail
PROFLEX®6036 WHIRLPOOL BATH WITH HEATER 1013750-1-
E
Loading...