DEVONSHIRE
®
Features
Acrylic
120 BubbleMassage
Drop-in
Textured bottom surface
UL listed
control 60(1524 mm) x 32(813 mm) x 20(508 mm)
TM airjets
Codes/Standards Applicable
Specified model meets or exceeds the following:
UL 1795
ASTM E162
ASTM E662
CSA B45.5/IAPMO Z124
ASME A112.19.7
Specified Model
5’ BUBBLEMASSAGETM BATH
K-1357-G
Colors/Finishes
0: White
Other: Refer to Price Book for additional colors/finishes
Accessories
CP: Polished Chrome
PB: Vibrant®Polished Brass
NA: None applicable
Other: Refer to Price Book for additional colors/finishes
Model Description Colors/Finishes
K-1357-G 5’ Bubblemassage bath 0 Other_____
Recommended Accessories
K-7161-AF Adjustable pop-up drain CP PB Other_____
Optional Accessories
K-1446 Remote blower installation kit NA
Product Specification
The acrylic drop-in Bubblemassage bath shall be 60(1524 mm) in length, 32(813 mm) in width, and 20(508 mm) in height. Bath shall have a blower motor with 300 W heater and an electronic user control. Bath shall feature a textured bottom surface and 120 Bubblemassage airjets. Bath shall be UL listed. Bubblemassage bath shall be Kohler Model K-1357-G-____.
Page 1 of 2 1034591-4-
F
USA/Canada: 1-800-4KOHLER
(1-800-456-4537)
www.kohler.com
Page 2
DEVONSHIRE
®
Technical Information
Required Electrical Service
Fixture*: Basin area: Bathing well 42(1067 mm) x 20(508 mm) Top area 51(1295 mm) x 24(610 mm) Weight 84 lbs (38.1 kg) To overflow: Water depth 14(356 mm) Capacity 60 gal (227.1 L) * Approximate measurements for comparison only.
Drop-in cut-out 58(1473 mm) x 30(762 mm)
Blower motor:
Heater V Hz A 300 W 120 60 5
Dedicated circuit required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):
Blower motor: 120 V, 15 A, 60 Hz Blower motor is supplied with a 24(610 mm)
grounding-type plug-in cord.
Installation Notes
NOTICE: If the blower motor and check valve are relocated, the following two procedures are required: 1.
Provide two access panels. Locate one access panel at the blower motor/control location and the other access panel at the control box. 2. Relocate the blower motor and the check valve together. Do not relocate one without the other.
Install this product according to the installation guide.
Floor support under the bath must provide for a minimum of 47 lbs/square foot (230 kg/square meter) loading.
A blower motor access panel is required.
No change in measurements with drain shown. (K-7161-AF or K-7161M-AF)
16" (406 mm)
2-1/4" (57 mm)
3" (76 mm)
1-1/2" OD
9" (229 mm)
60" (1524 mm)
2-1/2" (64 mm)
1" (25 mm)
Product Diagram
Blower Motor Access 18" (457 mm) W x 15" (381 mm) H
20" (508 mm)
18-1/2" (470 mm)
32" (813 mm)
DEVONSHIRE®5’ BUBBLEMASSAGETM BATH Page2of2
1034591-4-
F