Kohler KOH19161 Specifications

Page 1
WINDWARD
®
Features
Acrylic
Rectangular shape
Drop-in, 3-side integral flange
Pump with air switch and grounding-type plug-in cord
6 individually adjustable ProFlex
Molded lumbar supports and armrests
72(1829 mm) x 42(1067 mm) x 21(533 mm)
®
Codes/Standards Applicable
Specified model meets or exceeds the following:
CSA B45.5/IAPMO Z124
ASME A112.19.7
ASTM E162
ASTM E662
UL 1795
Specified Model
BATH WHIRLPOOL WITH INTEGRAL
FLANGE
K-1114-L
ALSO K-1114-R
Colors/Finishes
0: White
Other: Refer to Price Book for additional colors/finishes
Accessories
CP: Polished Chrome
Other: Refer to Price Book for additional colors/finishes
Model Description Colors/Finishes
K-1114-L Bath whirlpool with integral flange – left drain 0 Other_____ K-1114-R Bath whirlpool with integral flange – right drain 0 Other_____
Recommended Accessories
K-7166 Adjustable pop-up drain – above or through-the-floor installation OR CP Other_____ K-11677 Adjustable trip lever drain – through-the-floor installation CP Other_____
Optional Accessories
K-9696 Jet trim kit (metal finishes) CP Other_____
Product Specification
The rectangular acrylic bath whirlpool shall be 72(1829 mm) in length, 42(1067 mm) in width, and 21(533 mm) in height. Product shall be drop-in, 3-side integral flange. Product shall have 6 individually adjustable Proflex hydro-massage jets and a pump with air switch and grounding-type plug-in cord. Product shall have molded lumbar supports and armrests. Bath whirlpool shall be Kohler Model K-1114-____-____.
Page 1 of 2 1047222-4-
D
USA/Canada: 1-800-4KOHLER
(1-800-456-4537)
www.kohler.com
Page 2
WINDWARD
®
Technical Information
Required Electrical Service
Fixture*: Bathing well: Basin area, bottom 55(1397 mm) x 23-1/4(591 mm) Basin area, top 64(1626 mm) x 32(813 mm) Weight 132 lbs (60 kg) To overflow: Water depth 15(381 mm) Capacity 78.5 gal (297 L) * Approximate measurements for comparison only.
Drop-in cut-out dimensions:
Pump: V Hz A 1-speed 120 60 7.5
Minimum access panel pump/control: 20(508 mm) W x 15(381 mm) H required
70-1/2(1791 mm) x 40-1/2(1029 mm)
21" (533 mm)
Dedicated circuit required, protected with a Class A Ground-Fault Circuit-Interrupter (GFCI):
Pump/control 120 V, 15 A, 60 Hz Locate the outlet behind the whirlpool and within 24
(610 mm) of the pump.
Installation Notes
Install this product according to the installation guide.
Floor support under the whirlpool must provide for a minimum of 39 lbs/square foot (189 kg/square meter) loading.
If installing a rim-mount faucet, make sure there is no interference with the drain overflow and circulating system before drilling any holes. Consult local and national codes for minimum air gap requirements if installing a spout on the faucet deck.
No change in measurements if connected with drain illustrated. (K-11677)
Recommended faucet area
1-1/2" (38 mm)
1-1/4" (32 mm)
3-3/4" (95 mm)
11-1/16" (281 mm)
1-1/4"
72" (1829 mm)
(32 mm)
3-1/2" (89 mm)
3" (76 mm)
2-7/8" (73 mm)
3/8" (10 mm)
Product Diagram
WINDWARD®BATH WHIRLPOOL WITH INTEGRAL FLANGE Page2of2
1047222-4-
D
Pump/Control Access
1-1/4" (32 mm)
19-1/2" (495 mm)
21" (533 mm)
Drop-In
Rim Detail
42" (1067 mm)
1-1/2" OD
Tile Flange
Detail
Loading...