Installation Guide
Kitchen Sink Faucets
K-7341 K-7342
M product numbers are for Mexico (i.e. K-12345M)
Los números de productos seguidos de
M corresponden a México (Ej.
K-12345M)
Français, page “Français-1”
Español, página “Español-1”
1069123-2-B
Tools and Materials
Two 3/8" Male
Supply Connections
Adjustable
Wrench
Before You Begin
Observe all local plumbing and building codes.
Shut off the water supplies.
Carefully inspect waste and supply tubing for any sign of
damage and replace if necessary.
Do not use petroleum based products on this faucet.
Kohler Co. reserves the right to make revisions in the design of
faucets without notice, as specified in the Price Book.
1069123-2-B 2 Kohler Co.
Threaded
Hole
Stud
Sleeve
Escutcheon
Faucet Body
Supply Hose
O-Ring
Bracket
Nut
1. Install the Faucet
IMPORTANT! If you are mounting the faucet to an uneven surface
(such as tile grout lines), apply a suitable sealant in addition to the
O-rings provided. Do not use petroleum based sealant.
Thread the stud into the threaded hole of the faucet body until
the stud bottoms out.
Insert the O-ring into groove of the escutcheon.
Slide the sleeve and escutcheon around the threaded stud and
supply hoses until it is seated against the base of the faucet body.
Insert the supply hoses and stud through the mounting hole.
NOTE: The handles will rotate toward the user when properly
installed.
Slide the bracket and nut onto the stud from underneath the
mounting surface.
Securely tighten the nut.
Ensure the handles are in the OFF position, as shown.
Kohler Co. 3 1069123-2-B
Cold
3" (7.6 cm)
or Larger
Cold
Hot
2. Install the Supplies
CAUTION: Risk of restricted waterflow and product
damage. Use extreme care to avoid kinking and twisting the
supply hoses. The supply hoses must not be taut after
installation.
NOTE: If the sink installation requires that you coil the supply hoses
to obtain a good connection, maintain an inside coil diameter of at
least 3″ (7.6 cm).
Carefully position the hot and cold water supplies so they will
not interfere with other hoses or items below the mounting
surface.
Connect the supply hoses to the supply stops. Left is hot, right is
cold.
Tighten all connections.
1069123-2-B 4 Kohler Co.
Spout
Aerator
Housing
3. Installation Checkout
Verify all connections are tight.
Remove the aerator from inside the spout by turning the housing
counterclockwise.
Verify the handles are in the OFF position, then turn on the main
water supply.
Check all connections for leaks; repair as needed.
Turn the handles to the ON position to run water through the
faucet.
Check all connections for leaks. Make any adjustments as needed.
Allow water to run through the spout to remove any debris.
Turn the handles to the OFF position.
Reinstall the aerator into the spout, then turn the housing
clockwise to secure the aerator to the spout.
Kohler Co. 5 1069123-2-B