Kohler K6331VS Installation Manual

Installation Guide
Pull-Out Kitchen Sink Faucets
M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page “Français-1” Español, página “Español-1”
1071380-2-A
Thank You For Choosing Kohler Company
We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation. If you encounter any installation or performance problems, please don’t hesitate to contact us. Our phone numbers and website are listed on the back cover. Thanks again for choosing Kohler Company.
Tools and Materials
Phillips Screwdriver
1/8" Hex Wrench
CableTie
Adjustable Wrench
Two 3/8" Male Supply Connections
Before You Begin
CAUTION: Risk of fresh water contamination. This faucet contains important back-siphonage protection. Do not remove
any components. Observe all local plumbing and building codes. Shut off the water supplies. Before installation, unpack the new faucet and inspect it for
damage. Return the faucet to the carton until you are ready to install it.
Carefully inspect waste and supply tubing for any sign of damage and replace if necessary.
For new installations, assemble the faucet to the sink before installing the sink.
Do not use petroleum based products on this faucet. Kohler Co. reserves the right to make revisions in the design of
faucets without notice, as specified in the Price Book.
1071380-2-A 2 Kohler Co.
O-Ring
Fiber Washer
Metal Washer
Ring
Screws
Shank
1. Install the Faucet
Insert the O-ring into the groove of the faucet base.
IMPORTANT! If you are mounting the faucet to an uneven surface (such as tile grout lines), apply a suitable sealant in addition to the O-ring provided. Do not use petroleum based sealant.
Partially thread the screws into the ring until they barely protrude from the backside of the ring.
Position the faucet through the mounting surface. Slide the fiber washer and metal washer on the shank. Thread the ring to the threaded shank until it is about 1/4 turn
from touching the sink bottom. Turn the ring so the screws are to the front and back of the
faucet. Tighten the screws using a Phillips screwdriver.
Kohler Co. 3 1071380-2-A
Cold
3" (7.6 cm) or Larger
Cold
Hot
2. Install the Supplies
CAUTION: Risk of restricted waterflow and product
damage. Use extreme care to avoid kinking and twisting the
supply hoses. The supply hoses must not be taut after
installation.
NOTE: If the sink is not installed, install it at this time. Be sure to follow all instructions packed with the sink.
NOTE: If the sink installation requires that you coil the supply hoses to obtain a good connection, maintain an inside coil diameter of at least 3(7.6 cm).
Carefully position the hot and cold water supplies so they will not interfere with other hoses or items below the mounting surface.
Connect and tighten the supply hoses to the supply stops. Left is hot, right is cold.
3. Flush the Supply Lines
Place the valve outlet hose into a bucket or suitable container. Slowly turn on the hot and cold supplies. Slowly turn the faucet handle to the full cold position. Let the
water run briefly to remove any debris. Slowly turn the faucet handle to the full hot position. Let the
water run briefly to remove any debris. Turn the faucet handle to the OFF position.
1071380-2-A 4 Kohler Co.
Connect the Spray Hose
Weight
Reposition the Weight
(If Applicable)
O-Ring
Spray Hose
Valve Outlet Hose
2" (5.1 cm) – 3" (7.6 cm)
Cabinet Floor
Do not overtighten cable tie.
4. Connect the Spray Hose
Slide the weight onto the spray hose. Verify that the hose ends are clean and that the O-ring is in place. Fully engage the hose ends. Extend and retract the spray hose to check for smooth operation. Reposition the supply hoses if necessary. Check all connections for leaks. Verify the spray head is completely seated into the spout. If the
spray head is not seated properly, follow the Reposition the Weightprocedure below.
Reposition the Weight
Position the weight between 2(5.1 cm) and 3(7.6 cm) from the cabinet floor.
Secure a cable tie (not provided) around the spray hose and below the weight, as shown. Do not overtighten the cable tie
around the spray hose.
Cut the free end of the cable tie. Be careful not to damage the spray hose.
Extend the spray hose to ensure the spray hose does not snag or catch on items in the cabinet.
Retract the spray hose and verify that the spray head is properly seated into the spout.
Kohler Co. 5 1071380-2-A
O-Ring
Valve Stem
Indexer
Handle
Valve Stem Cover
Setscrew Plug Button
5. Optional Temperature Limiting Adjustment
NOTE: The water temperature does not need to be adjusted if the water temperature is below 105°F (41°C).
NOTE: Before adjusting the water temperature, ensure the handle is turned all the way to the maximum hot position.
Remove the plug button, setscrew, and handle from the valve stem.
Reposition the indexer to stop the valve stem at the desired maximum temperature.
Place the handle onto the valve stem. Do not secure. Turn the handle to the full hot position and check the water
temperature. Repeat the above procedures until the desired temperature is
reached. Reinstall the handle. Reinsert the setscrew into the valve stem, then tighten. Reinstall the plug button.
1071380-2-A 6 Kohler Co.
Guide d’installation
Robinets d’évier de cuisine escamotables
Outils et matériels
Tournevis cruciforme
Clé hexagonale de 1/8"
Serre-câble
Clé à molette
Deux connexions d'alimentation mâles de 3/8"
Merci d’avoir choisi la compagnie Kohler
Nous apprécions votre engagement envers la qualité Kohler. Veuillez prendre s’il vous plaît quelques minutes pour lire ce manuel avant de commencer l’installation. Ne pas hésiter à nous contacter en cas de problème d’installation ou de performance. Nos numéros de téléphone et notre adresse du site internet sont au verso. Merci encore d’avoir choisi la compagnie Kohler.
Avant de commencer
ATTENTION : Risque de contamination d’eau fraîche. Ce
robinet contient une protection importante de siphon
anti-retour. Ne retirer aucun composant. Respecter tous les codes de plomberie et de bâtiment locaux. Couper les alimentations d’eau. Avant l’installation, déballer le nouveau robinet et l’examiner
pour en déceler tout dommage. Remettre le robinet dans son emballage de protection jusqu’à être prêt à l’installation.
Vérifier avec soin si l’évacuation ou les tubes d’alimentation pour déceler tout signe d’endommagement et remplacer si nécessaire.
Kohler Co. Français-1 1071380-2-A
Avant de commencer (cont.)
Pour de nouvelles installations, installer le robinet sur l’évier avant d’installer ce dernier.
Ne pas utiliser de produits à base de pétrole sur ce robinet. Kohler Co. se réserve le droit d’apporter toutes modifications au
design des robinets et ceci sans préavis, comme spécifié dans le catalogue des prix.
1071380-2-A Français-2 Kohler Co.
Loading...