Kohler K14234SPG9 Installation Manual

COUNTERTOP LAVATORIES
R
Carefully read these instructions before you attempt to remove your old lavatory.Before installingyour new lavatory,make sureyou have the proper materials necessary to complete the job. This will help you avoid costly mistakes.
Do not install this lavatory on a glass countertop. The weight of the lavatory may damage the glass.
Your new Kohler fixture has been designed for installation using common tools.
K-2184 Chenille K-2199 Cantata K-2217 Linia K-2220 Vintage K-2264 Centerpiece K-2292 Intaglio K-2298 Compass K-2332 WaterCove K-14156 Garland K-14170-RB Provincial K-14173 Fables and Flowers K-14234-BT Botanical Study K-14234-SP Serpentine Bronze K-14246-AC Ocellus Citron K-14246-AS Ocellus Skylight K-14270-PS Peonies and Ivy K-14271-WF Prairie Flowers
K-14272-BR Briar Rose Floral.......................
K-14272-P Pheasant K-14272-TF Ankaras
t.................................
t.................................
t....................................
t.................................
t.............................
r..................................
t...............................
t..............................
t................................
t...........................
t......................
t......................
t....................
t.......................
t......................
t......................
t.......................
t.............................
t.............................
WITHOUTFAUCETDECK
Materials required:
D PLUMBERS PUT TY D NEW FAUCET(OPTIONAL) D SHUT-OFF VALVES(OPTIONAL) D SAFETY GLASSES
Before you remove your old fixture, unpack the new lavatory and carefully inspect it for any damage that may have occured. Vitreous china and enameled cast iron may chip, and you discover damage after the unit has been installed. Until you are ready to begin installation, set the lavatory back in the original packing carton to prevent damage.
Make sure you have a cut-out template to aid you in locating your faucet centerline on the countertop, and incutting outyour countertop.
do not want to
Tools required:
D PUTTY KNIFE D ADJUSTABLE WRENCH D SABER OR KEYHOLE SAW D PIPE WRENCH D TUBING CUTTER D SCREWDRIVER D HACKSAW D RULER D PENCIL D DRILL D 1/2” DRILL BIT D 1-3/16” HOLE SAW D 1-3/8” HOLE SAW (FOR WIDESPREAD FAUCETS) D CUT-OUT TEMPLATE (FURNISHED WITH FIXTURE)
1007251-2-
B
Français, Page 6
Español, Página 11
E2003 Kohler Co.
LOCATING THE FAUCET CENTERLINE
DRAW PRELIMINARY FAUCET CENTERLINE
This lavatory is a unique installation with the faucet fittings mounted on the countertop rather than on the lavatory itself.
The best location of the faucet centerline is determined by three items: the size of the fitting or faucet spout escutcheons, length of faucet spout, and clearance between the faucet spout and lavatory rim.
FAUCET LOCATION
1.Refer to Fig. #1 . Determine if the faucet spout escutcheon or
faucet handle escutcheon will be closer to the lavatory rim when installed. Items to consider are the sizes of the different faucet components and the lavatory shape. The escutcheon found to be closest to the lavatory rim will be used in step 2.
X
XX
Faucet Handle Escutcheon
Faucet Spout Escutcheon
Lavatory Rim
NOTE: The following instructions refer to the installation of Model K---2332, in an above counter installation.
NOTE: Wall-mount faucet installations: Be sure to provide sufficient spout overhang into the lavatory basin. Make surethat the water stream is directed to the center of the lavatory and there is sufficient hand washing clearance.
NOTE: Countertop faucet installations: Pay special attention tothe spout and handlefit clearancewhen locatingthe faucet,as noted below.
Countertop faucet installations: Use the template to locate the faucet spouthole centerline to provideadequate clearance between the edge of the lavatory and the spout.
Refer to Fig. #2 . Check for adequate clearancebetween the back­splash, faucet spoutand handles and lavatory.Kohler recommends clearance of at least 1” (2.5cm) between:
D the installed lavatory and the faucet spout; D the installed lavatory and the end of the faucet handles D the faucet spout and handles, and the backsplash.
Refer to the faucet installation instructions for the required clearance, and mark the preferred faucet hole locations.
Spout Centerline
Backsplash
;
Fig. #1
2.Measure the escutcheon, front-to-back, that was found to be
closest to the rim in step 1. This escutcheon measurement may also be found on the faucet roughing-in page.
3.Divide the front-to-back dimension in half, and add 1/4”.
Standard sizes are shown in the chart on the next page. The distance found will be used to draw the preliminary faucet centerline.
NOTE: For all front to back dimensions, round up to the nearest 1/16” (2mm) if required.
FRONT TO BACK DIMENSION
2” (5cm) 1-1/4” (3.2cm) 2-1/8” (5.4cm) 1-5/16” (3.3cm) 2-1/4” (5.7cm) 1-3/8” (3.5cm) 2-3/8” (6cm) 1-7/16” (3.7cm) 2-1/2” (6.4cm) 1-1/2” (3.8cm)
DISTANCE TO DRAW CENTERLINE BEHIND REFERENCE LINE
Cut-out Line
Fig. #2
1”(2.5cm) Minimum Clearance
Outside Edge of Lavatory
1-1/4”(3.2cm) Minimum Clearance
1007251-2-
B
2
Kohler Co.
DRAW PRELIMINARY FAUCET CENTERLINE
1. Draw the distance determined in FAUCET LOCATION as the
preliminary centerline on the cut-out template. It should be parallel and behind the cut-out template reference line (located on the cut-out template).
NOTE: On the full-size rim section found on the cut-out template, mark the preliminary faucet centerline dimension. This will be used to DETERMINE FINAL FAUCET CENTER-
LINE.
DETERMINE FINAL FAUCET CENTERLINE
NOTE: If you are installing a tiled-in lavatory,proceed toStep 1B. The preliminary faucet line from DRAW PRELIMINARY FAUCET LINE is the final faucet line in this case.
1. When this preliminary faucet centerline has been drawn the
spout must be checked for three items:
A. Refer to Fig. #2. For low profile faucet spouts, the
distance between the faucet spout and the lavatory rim must be a minimum of 1/4” (6mm). Use the faucet spout, the preliminary faucet centerline,and the full size rim sectionon the cut-outtemplate to check this. If there is not 1/4” (6mm) clearance, move the preliminary faucet centerline back. Recheck the clearance until you have 1/4”(6mm). Measure the distanceof the new faucet centerline. Redraw the new faucet centerline behind the reference line on the cut-out template. Remark this dimension on the full size rim section. This is the final faucet centerline.
2” (5cm)
Min.
Fig. #4
Air Gap
FAUCET CLEARANCE WITH BACKSPLASH
NOTE: 2-1/2” (6,4cm) of space is requiredfor the KohlerBravura
widespread and Cirrus Sheetflow faucet spouts.
1.Refer to Fig. #4. Draw a line 2” (5cm) behind the final faucet
centerline on the cut-out template. This is the minimum backsplash locator line. It is drawn to ensure adequate clearance behind the faucet for proper installation. It will also help position the lavatory on the countertop. Cut along this backsplash locator line. Save the section of the cut-out template with the lavatory rim and cut-out lines.
Countertop Backsplash Backsplash Locator Line
2”
(5cm)
C
L of Fitting
1/4” (6mm)Min.
2” (5cm) Min.
Fig. #3
B. Refer to Fig. #3. Check to be sure the water stream will
project 2” (5cm) minimum into the lavatory basin to allow adequate area for hand washing.Use the approximate faucet spout angle,the final faucet centerline and the full-size rim section from the cut-out template to ensure this clearance. If this cannot be accomplished, the faucet is not optimally matched for this lavatory and may not operate on this lavatory to the owner’s satisfaction. You may wish to consider an alternate faucet.
C. Refer to Fig. #3. Check for compliance with all state and
local plumbing codes, including air gap standards.
Cut-Out T emplate On Countertop
Countertop
Fig. #5
INSTALLATION
1. To remov e old lav atory, turn off water supp lies. Turn the
lavatory faucet on to drain water from the lines. Disconnect and remove water supply tubes. Disconnect drain and remove trap.
CAUTION: To remove steel frame lavatories, remove
clips or fasteners under lavatory that hold lavatory to counter. Do not remove clips that hold frame to fixture.
1007251-2-
B
3
Kohler Co.
2. Lift lavatory out of countertop with fitting and drain attached, if
applicable.
3. Refer to Fig. #6 . Cut out inside of cut-out template with
scissors on the inside line.
Fig. #6
5. Refer to Fig. #8 . Drill a pilot hole into the countertop using a
1/2” drill. Use a saber or keyhole saw to cut out opening by carefully following the pencil line traced from cut-out template. T emporarily position lavatory into counter, and trace a light pencil line around the outside edge. This will serve asa guideline for applying sealant. Remove fixture from countert op.
NOTE: The rim must be traced so the sealant will cover and conceal the pencil line.
4. Refer to Fig. #7 . Set the cut-out template on the countertop
so the backsplash locator line is touching the countertop backsplash. The cut-out template can be moved forward from this position to get the best placement of the lavatory on the countertop. Tracethe cut-out opening on the countertop using asoft lead pencil. Centerlines are provided to help align opening. Mark the final centerline on the countertop using the cut-out template. Drill the faucet holes using the following chart to determine their size.
NOTE: If there is not enough room at the front of the counter for the lavatory rim, a larger countertop is needed.
Dimensions Are For Kohler Faucets Only. When Using Other Faucets, Contact Supplier For Installation Instructions And Dimensions.
FAUCET CENTERS VALVE HOLES SPOUT HOLE
4” (10.2cm) 1-3/16” (3cm) 1-3/16” (3cm)
6” (15.2cm)
8” (20.3cm) 12” (30.5cm) 16” (40.6cm)
Faucet Escutcheon Handle Escutcheon
Backsplash
1-3/8” (3.5cm) 1-3/16” (3cm)
Centerline
1/4” (6mm) Min.
Fig. #8
6. Install faucet to countertop and drain to lavatory following
manufacturer’s instructions.
7. Refer to Fig. #9 . Apply two ribbonsof plumbersputty orother
sealant on the counter from the edge of the opening to edge of rim as measured in Step 5 according to the putty manufacturer’ s instructions. Quickly spread putty or sealant with a putty knife.
Plumbers Putty
Lavatory
Countertop
Fig. #9
8. Set lavatory into position. Immediately wipe away any excess
putty or sealantwith a damp cloth.Fill in any voids between rim and countertop.
9. Allow putty or sealant to set for 30 minutes. Connect supply
lines at supply valves and fitting. Assembleadjustable drain pop-up linkage. Connect drain, trap, and outlet. Turn tailpiece into drain body. Align trap inlet with tailpiece. Insert trap nut and gasket onto tailpiece, and insert into trap. Tailpiece must extend 1” to 2” into trap. Tailpiece may have to be cut to fit. Turnon water and check for leaks.
Countertop
1007251-2-
10. CARE AND CLEANING. DO NOT USE ABRASIVE
CLEANSERS as they m ay scra tch the surf ace of this fixtu re.
Fig. #7
B
Clean up with a non-abrasive cleaner.Stubborn stains, paint, ortar may be removed with turpentine or paint thinner.
4
Kohler Co.
CALL US FOR HELP
Here’s what you need to do if you require service: First review the installation instructions to ensure correct installation. For additional assistance in the USA, call our
Customer Service Department for direct help. You may also contact us at our web site listed below.
Call 1-800-4-KOHLER within the U.S.
Call 1-800-964-5590 within Canada
Call 001-877-680-1310 within Mexico
kohler.com
E2003 Kohler Co.
1007251-2-
B
5
Kohler Co.
Loading...
+ 11 hidden pages