Kohler K1357GRA0 User Manual

DEVONSHIRE
®
Features
Acrylic
Blower motor is supplied with a grounding-type
plug-in cord Integral apron with removable access panel
Integral tile flange
Left or right drain
Molded lumbar supports and armrests
Blower motor with 300 W heater and electronic user
control 60(152.4 cm) x 32(81.3 cm) x 20(50.8 cm)
TM airjets
Codes/Standards Applicable
Specified model meets or exceeds the following:
ANSI Z124.1.2
IAPMO IGC 171
UL 1795
ASTM E162
ASTM E662
Specified Model
5’ BUBBLEMASSAGETM BATH
K-1357-GLA
ALSO K-1357-GRA
Colors/Finishes
0: White
Other: Refer to Price Book for additional colors/finishes
Accessories
CP: Polished Chrome
PB: Vibrant®Polished Brass
NA: None applicable
Other: Refer to Price Book for additional colors/finishes
Model Description Colors/Finishes
K-1357-GLA 5’ Bubblemassage bath – left drain 0 Other_____ K-1357-GRA 5’ Bubblemassage bath – right drain 0 Other_____
Recommended Accessories
K-1446 Remote blower installation kit NA K-7161-AF Adjustable pop-up drain CP PB Other_____
Product Specification
The acrylic Bubblemassage bath shall be 60(152.4 cm) in length, 32(81.3 cm) in width, and 20(50.8 cm) in height. Product shall have an integral apron with removable access panel and integral tile flange. Product shall feature molded lumbar supports and armrests. Product shall be available with left or right drain. Product shall feature a blower motor with 300 W heater, and an electronic user control. Blower motor shall be supplied with a grounding-type plug-in cord. Product shall have 120 Bubblemassage airjets. Bubblemassage bath shall be Kohler Model K-1357-____-____.
Page 1 of 2 1040137-4-
C
USA/Canada: 1-800-4KOHLER
(1-800-456-4537)
www.kohler.com
DEVONSHIRE
®
Technical Information
Required Electrical Service
Fixture*: Bathing well: Basin area, bottom 42(106.7 cm) x 20(50.8 cm) Basin area, top 51(129.5 cm) x 24(61 cm) Weight 98 lbs (44.5 kg) To overflow: Water depth 14-1/2(36.8 cm) Capacity 60 gal (227.1 L) * Approximate measurements for comparison only.
Blower motor: Heater V Hz A
300 W 120 60 5
Dedicated circuit required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):
Blower motor 120 V, 15 A, 60 Hz Blower motor is supplied with a 24(61 cm)
grounding-type plug-in cord.
Installation Notes
NOTICE: If the blower motor and check valve are relocated, the following two procedures are required: 1.
Provide two access panels. Locate one access panel at the blower motor/control location and the other access panel at the control box. 2. Relocate the blower motor and the check valve together. Do not relocate one without the other.
Install this product according to the installation guide.
Floor support under the bath must provide for a minimum of 47 lbs/square foot (229 kg/square meter) loading.
No change in measurements with drain shown. (K-7161-AF or K-7161M-AF)
16" (40.6 cm)
2-1/4" (5.7 cm)
3" (7.6 cm)
1-1/2" OD
9" (22.9 cm)
60" (152.4 cm)
2-1/2"
1" (2.5 cm)
(6.4 cm)
21-1/4" (54 cm)
Product Diagram
1-1/4" (3.2 cm)
1/2" (1.3 cm) R.
Integral Flange Detail
32" (81.3 cm)
20" (50.8 cm)
DEVONSHIRE®5’ BUBBLEMASSAGETM BATH Page2of2
1040137-4-
C