Kohler K1239GRF0 Specifications

Features
Integral flange.
Right drain.
Integral lumbar support and armrests for comfort.
Textured bottom surface.
60" (1524 mm) x 35-7/8" (911 mm) x 20" (508 mm)
Material
Hydrotherapy
120 BubbleMassage™ airjets.
Automatic purge cycles remove residual water from air channels after use.
Built-in 300 W heater.
Variable-speed blower for adjusting hydromassage intensity.
Electronic keypad control.
Mariposa
®
5' BubbleMassage™ Bath
K-1239-GRF
Installation
Alcove
Recommended Accessories
K-1234 Removable Apron K-1446 Remote Installation Kit K-1491 Bath/Whirlpool Pillow K-1601 Bath/Whirlpool Footstop K-7166-AF Bath Drain K-24916 Wireless Music Kit K-37380 30" Rough-in Cable Bath Drain K-37383 30" Rough-in Cable Bath Drain K-37386 30" Rough-in Cable Bath Drain
Codes/Standards
ASME A112.19.7/CSA B45.10 CSA B45.5/IAPMO Z124 ASTM E162 ASTM E662 UL 1795 Greenguard UL 2818 - Gold CARB P2
KOHLER® One-Year Limited Warranty
See website for detailed warranty information.
Available Color/Finishes
Color tiles intended for reference only.
DescriptionCodeColor
White0
Biscuit96
Almond47
DuneNY
SandbarG9
USA/Canada: 1-800-4KOHLER (1-800-456-4537) Kohler Co. reserves the right to make revisions without notice to product specifications. For the most current Specification Sheet, go to www.kohler.com. 3-15-2018 02:43
Integral Flange Detail
Mariposa
®
5' BubbleMassage™ Bath
K-1239-GRF
Required Electrical Service
One dedicated circuit required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD).
120 V, 15 A, 60 HzBlower:
Technical Information
All product dimensions are nominal.
3-Wall AlcoveInstallation: RightDrain location: 46" x 24" (1168 mm x 610 mm)Basin area, bottom: 54" x 27" (1372 mm x 686 mm)Basin area, top: 100 lbs (45.4 kg)Weight:
rating:
43.5 lbs/ft² (212.4 kg/m²)Minimum floor load: 14" (356 mm)Water depth: 63 gal (238.5 L)Water capacity: Drop-in, 58" x 34" (1473 mm x 864 mm)Cutout: Blower: 120 V, 10 A, 60 HzElectrical component
VariableBlower speed: 2" (50 mm)Minimum flat for door:
Notes
Measure your actual product for rough-in details.
Install this product according to the installation instructions.
The hot water supply should be 70% of the capacity of the bath or greater. Installations will vary.
Provide one grounded electrical outlet within 24" (610 mm) of each component.
Remote blower installation kit K-1446 is available for relocating the blower. Provide access for servicing the blower.
Do not relocate or alter the PVC tee or coiled flexible tubing connected to the blower. Follow the blower relocation instructions exactly.
If installing a rim-mount faucet, make sure there is no interference above or below the deck before drilling any holes.
USA/Canada: 1-800-4KOHLER (1-800-456-4537) Kohler Co. reserves the right to make revisions without notice to product specifications. For the most current Specification Sheet, go to www.kohler.com. 3-15-2018 02:43