Kohler 1043183-5-D User Manual [en, es, fr]

Homeowners Guide
Six-Port Thermostatic Valve
K-682
M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page “Français-1” Español, página “Español-1”
IMPORTANT INSTRUCTIONS
WARNING: When using electrical products, basic precautions should always be followed, including the following:
DANGER: Risk of electric shock. Grounding is required. Connect only to circuits protected by a
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD).
WARNING: Risk of electric shock. A qualified service representative and a licensed electrician must install this product and route all electrical wiring for the product. Improper installation will create an electrical hazard and may not comply with local building and electrical codes.
WARNING: Risk of electric shock. Disconnect power before performing any maintenance. When disconnected, the product will no longer be electrically live, which will eliminate the risk of electric shock.
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before beginning installation.
NOTICE: Follow all plumbing, electrical and building codes.
NOTICE: Provide generous, unrestricted service access to the valve and interface. This access must be
located immediately next to the valve. Refer to the roughing-in information.
Specifications
Pressures
Maximum Static Pressure 125 psi, 862 kPa, 8.6 bar Supply Pressure Differential* Max 5 psi, 34.5 kPa, 0.34 bar (Equal pressures recommended.) Minimum Flow Rate 1.6 gal/min (Less than 72 psi dynamic pressure.)
Temperatures
Programmable Temperature Max 120°F (49°C) Min 79°F (26°C) Full cold may also be selected. Default Temperature at Start-up 102°F (39°C) Minimum Mixed Temperature
Differential from Hot Supply Optimum Thermostatic Control Range 86°F (30°C) to 120°F (49°C) Temperature Stability at Recommended
Supply Conditions Ambient Temperature Greater than 34°F (1°C), Max 104°F (40°C) Maximum Relative Humidity 95% non-condensing
Electrical
Electrical Service 100-240 VAC, 50-60 Hz, 1.5 A User Interface Cable Length (supplied) 30’ (9.14 m)
* In commercial applications where there is a large difference in hot and cold supply pressures or frequent fluctuation in either supply line is anticipated, it is strongly recommended that pressure regulators be installed.
6 l/min (Less than 500 kPa maintaining pressure.)
2.1 gal/min (Greater than 72 psi dynamic pressure.) 8 l/min (Greater than 500 kPa maintaining pressure.)
3.6°F (2°C)
+/- 1.6°F (1°C)
Warranty
KOHLER®Electronic Faucets, Valves and Controls FIVE-YEAR LIMITED WARRANTY
Kohler Co. warrants that its electronic faucets, valves and controls will be free of defects in material and workmanship during normal residential use for five years from the date the product is installed. This
1043183-5-E 2 Kohler Co.
Warranty (cont.)
warranty applies only to electronic faucets, valves and controls installed in the United States of America, Canada and Mexico (North America).
If a defect is found in normal residential use, Kohler Co. will, at its election, repair, provide a replacement part or product, or make appropriate adjustment where Kohler Co.’s inspection discloses any such defect. Damage caused by accident, misuse, or abuse is not covered by this warranty. Improper care and cleaning will void the warranty*. Proof of purchase (original sales receipt) must be provided to Kohler Co. with all warranty claims. Kohler Co. is not responsible for labor charges, installation, or other incidental or consequential costs other than those noted above. In no event shall the liability of Kohler Co. exceed the purchase price of the faucet, valve or control.
If the electronic faucets, valves or controls are used commercially or are installed outside of North America, Kohler Co. warrants that the faucet, valve or control will be free from defects in material and workmanship for one (1) year from the date the product is installed, with all other terms of this warranty applying except duration.
If you believe that you have a warranty claim, contact your Home Center, Dealer, Plumbing Contractor or E-tailer. Please be sure to provide all pertinent information regarding your claim, including a complete description of the problem, the product, model number, the date the product was purchased, from whom the product was purchased and the installation date. Also include your original invoice. For other information, or to obtain the name and address of the service and repair facility nearest you, write Kohler Co., Attn: Customer Care Center, Kohler, Wisconsin 53044 USA, or by calling 1-800-4-KOHLER (1-800-456-4537) from within the USA and Canada, and 001-800-456-4537 from within Mexico, or visit www.kohler.com within the USA, www.ca.kohler.com from within Canada, or www.mx.kohler.com in Mexico.
THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
KOHLER CO. AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of such damages, so these limitations and exclusions may not apply to you. This warranty gives the consumer specific legal rights. You may also have other rights that vary from state/province to state/province. This warranty is to the original consumer purchaser only, and excludes product damage due to installation error, product abuse, or product misuse, whether performed by a contractor, service company, or the consumer.
This is Kohler Co.’s exclusive written warranty. *Never use cleaners containing abrasive cleansers, ammonia, bleach, acids, waxes, alcohol, solvents or
other products not recommended for chrome. This will void the warranty.
Kohler Co. 3 1043183-5-E
Inlet Clamp
O-Ring
Screw
Clean the Inlet Screens
Disconnect the power and turn off the water supply.
Disconnect and remove the removable pipe segment. Using a screwdriver, remove the inlet clamp screws. Remove the inlet clamp. Remove the adapters from the valve inlets. Gently pull the check valves from the valve inlets. Remove the screens from the check valves. Clean the screens to remove any dirt or debris. Rinse or replace the check valves and screens. Reassemble the inlet connections.
Check Valve
Screen
Adapter
Union Connection
Removable Pipe Segment
Troubleshooting
WARNING: Risk of electric shock. Disconnect power before performing any maintenance. When disconnected, the product will no longer be electrically live, which will eliminate the risk of electric shock.
CAUTION: Risk of personal injury. The valve may contain hot water; be careful when draining any residual water.
NOTICE: Any valve maintenance should be performed by a Kohler Co. Authorized Service Representative.
1043183-5-E 4 Kohler Co.
Troubleshooting (cont.)
NOTICE: Turn off the water supply to the valve before performing any maintenance.
NOTICE: This section is for general aid only. A Kohler Co. Authorized Service Representative or qualified electrician should correct any electrical problems. For warranty service, call 1-800-4KOHLER from within the USA and Canada, or 001-800-456-4537 from within Mexico.
For service parts information, visit your product page at www.kohler.com/serviceparts.
Troubleshooting Table Symptoms Probable Cause Recommended Action
1. Control panel is not lit. A. Power supply is not plugged
2. The interface power
indicator pulses but does not turn on.
3. The interface functions
normally but no water flows from the components.
4. Only cold water from the
outlets.
into the outlet.
B. Power supply connection to the
valve may be loose or disconnected.
C. Interface cable connections may
be loose or disconnected.
D. Circuit breaker has been
tripped.
E. The valve memory may require
resetting.
F. If none of the above actions
correct the symptom, the valve or interface requires servicing.
A. Interface cable connections may
be loose or disconnected.
B. If the above recommended
action does not correct the symptom, the interface or valve requires servicing.
A. Inlet/outlet fittings may be
blocked.
B. Hot and cold water supplies are
not turned on.
C. The valve memory may require
resetting.
D. System error. D. Check the user interface for an
E. If none of the above actions
correct the symptom, the valve requires servicing.
A. Hot water supply is either not
turned on or not connected to the valve inlet.
Hot water inlet is blocked. B. Check if the hot water inlet screen
B.
C. If none of the above actions
correct the symptom, the valve requires servicing.
A. Plug the power supply into the
outlet.
B. Check power supply connections to
the valve and reconnect if needed.
C. Check all interface cable
connections, connect if needed.
D. Reset the circuit breaker.
E. Disconnect and reconnect the
power supply from the valve.
F. Contact your Kohler Co.
Authorized Service Representative.
A. Check all interface cable
connections, connect if needed.
B. Contact your Kohler Co.
Authorized Service Representative.
A. Check the inlets and outlets for
blockage or debris. Clean the inlet screens. Refer to the Clean the Inlet Screenssection in the Homeowners Guide.
B. Turn on the water supply to the
valve.
C. Disconnect and reconnect the
power supply from the valve.
error code. Refer to the User Interface Homeowners Guide.
E. Contact your Kohler Co.
Authorized Service Representative.
A. Check if the hot water supply is
turned on and connected to the valve inlet.
for blockage. Clean or replace the inlet screen.
C. Contact your Kohler Co.
Authorized Service Representative.
Kohler Co. 5 1043183-5-E
Troubleshooting (cont.)
Troubleshooting Table Symptoms Probable Cause Recommended Action
5. Fluctuating or reduced
flow rate. Valve is functioning properly.
6. Blend temperature drift or
temperature cycling.
7. Maximum blend
temperature too hot or too cold.
8. Continuous flow. A. System will not switch off. A. Turn off the water and power
9. Water leaking from the
valve.
WARNING: Risk of electric shock and personal injury. Turn off
the main power and water supply.
10. Massage mode shuts
down but water continues to run from showerhead(s).
11. Hot water only, the valve
shuts down.
A. Inlet/outlet fittings may be
blocked.
B. Water outlet pressure is low. B. Check that the flow rate is at or
C. Fluctuating flow. C. Verify that the dynamic inlet
D. If none of the above actions
correct the symptom, the valve requires servicing.
A. Fluctuating water temperature. A. Check the inlet temperature
B. Hot water supply temperature
fluctuation.
C. Pressure difference greater than
5 psi (34.5 kPa) between the hot and cold supply lines.
D. If none of the above actions
correct the symptom, the valve requires servicing.
A. Incorrect maximum temperature
setting.
B. If none of the above actions
correct the symptom, the valve requires servicing.
A. Connections not secure.
B. Seals are worn or damaged. B. Order a seal service pack and
C. Internal leak. C. Unit requires overhaul. Contact
A. Unequal flow rates between
valve outlets.
B. Fluctuation of the inlet water
pressure.
C. Pressure difference greater than
5 psi (34.5 kPa) between the hot and cold supplies.
A. Hot and cold lines are reversed. A. Switch hot and cold water supply
A. Check the inlets and outlets for
blockage or debris. Clean the inlet screens. Refer to the Clean the Inlet Screenssection in the Homeowners Guide.
above the minimum rate required. Refer to the Specificationssection.
pressures are within specifications. Refer to the Specificationssection.
D. Contact your Kohler Co.
Authorized Service Representative.
differentials and verify they are sufficient. Refer to Specifications.
B. Check and make adjustments as
needed.
C. Install pressure regulators to bring
supply lines within 5 psi (34.5 kPa) of each other.
D. Contact your Kohler Co.
Authorized Service Representative.
A. Refer to the User Interface
Homeowners Guide.
B. Contact your Kohler Co.
Authorized Service Representative.
supply and contact your Kohler Co. Authorized Service Representative.
A. Check all connections. Make
adjustments as needed.
replace all seals.
your Kohler Co. Authorized Service Representative.
A. Revise installation to have one
bodyspray per valve outlet. Use bodysprays with the same flow rate.
B. Install pressure regulators in the
supply lines.
C. Install pressure regulators to bring
supply lines within 5 psi (34.5 kPa) of each other.
connections. Verify the hot water supply is connected to the Hinlet and the cold supply is connected to the Cinlet.
1043183-5-E 6 Kohler Co.