Handle with care and inspect regularly to ensure product is in good working order.
If this product, power supply cord or plug shows any signs of damage: stop use,
Before Initiation
1. To avoid damage, place the unit in an upright position for at least 24 hours before
initiation.
2. Make sure that the air outlet and air inlet are never blocked.
3. Only operate the unit on a horizontal surface to ensure no water leaks out.
Warnings
•Any person who is involved with working on or breaking into a refrigerant circuit
should hold a current valid certificate from an industry-accredited assessment
authority which authorises their competence to handle refrigerants safely in
accordance with an industry recognised assessment specification.
•When disposing of either the appliance or its packaging, do so only in an
environmentally conscious manner. Refer to local guidelines for more information.
•The appliance shall be stored in a well-ventilated area where the size corresponds
to the room area as specified for operation. For this appliance, only use in rooms
larger than 14m
2
.
•The appliance shall be stored in a manner preventing mechanical damage from
occurring.
•Ensure the following regarding the refrigerant pipes:
o The installation of pipework shall be kept to a minimum.
o The pipework shall be protected from physical damage and, in the case of
flammable refrigerants, shall not be installed in an unventilated space.
o Compliance with national gas regulations shall be observed.
o The mechanical connections shall be accessible for maintenance
purposes.
oFor appliances containing flammable refrigerants, the minimum floor area
of the room shall be mentioned in the form of a table or a single figure
without reference to a formula.
• Keep any required ventilation openings clear of obstruction.
• Servicing shall be performed only as recommended by the manufacturer.
• Ensure ducts connected to the appliance does not contain a potential ignition
source.
•When the portable air conditioner or dehumidifier is turned on, the fan can work
continuously under normal conditions to provide the minimum air volume of
100m3/h even when the compressor is closed due to the temperature controller.
• Do not pierce or burn the appliance.
• Use only implements recommended by the manufacturer for defrosting or cleaning.
• Never store the appliance in a room in which there are permanent sources of
ignition (e.g. open flames, a switched-on gas appliance or a switched-on electric
heater).
•Do not perforate any of the components in the refrigerant circuit. Refrigerant gas
may be odourless.
•Maintenance and repairs requiring the assistance of other qualified personnel must
be carried out under the supervision of specialists in the use of inflammable
refrigerants.
•All repairs must be carried out in accordance with the manufacturer’s
recommendations.
•Maintenance and repairs requiring the assistance of other qualified personnel must
be carried out under the supervision of specialists in the use of inflammable
refrigerants.
•Do not perforate any of the components in the refrigerant circuit. Refrigerant gas
may be odourless.
Appliance with R290 Refrigerant Gas
Caution: Risk of fire
•DANGER: It is hazardous for anyone other than an authorised service person to
service this appliance. In Queensland, the authorised service person MUST hold a
Gas Work Authorisation for hydrocarbon refrigerants to carry out servicing or repairs
which involve the removal of covers.
• This appliance contains approximately 235g of R290 refrigerant gas.
• The appliance shall be installed, operated, and stored in a room with a floor area
larger than 14m
2
.
Notes on Refrigerant R290
•The air conditioning system must be kept and transported upright. Otherwise,
irreparable compressor damage may occur. Leave the unit for at least 24 hours
before putting it into operation.
• Switch off the device and disconnect it from the power supply before cleaning.
• Make sure that the product creates a steady stream of air. Ensure the air inlets and
outlets are not blocked.
• To prevent leaks, operate this unit on a horizontal surface.
• Any person performing work on a refrigerant circuit should have a current certificate
from an industry-accredited assessment body. This ensures competence for the
safe handling of refrigerants according to an industry-recognised assessment
specification.
•If the device stops working, dispose of it properly and with regard for the
environment.
• Store the device in a well-ventilated place when not in use.
• Store the device so that it is not damaged.
• Repairs may only be carried out by the manufacturer or an authorised specialist
company.
•Do not damage any components of the refrigerant circuit. Escaping refrigerant
may not be noticed because it is odourless.
•Maintenance and repairs must be carried out under the supervision of specialists in
the use of flammable refrigerants.
General safety instructions
•Check the voltage specification on the rating plate before use. Connect the
appliance only to sockets that correspond to the voltage of the appliance.
•The appliance is intended for household use only. Use the appliance only indoors
and in a dry environment.
•Do not use the product if it needs to be repaired or if it has not been installed
properly.
•Do not place heavy objects on the power cord, as damage to the cord may cause
an electric shock.
•Do not operate the appliance with wet hands or touch the plug and cable with wet
hands.
• Do not use the product in the following areas:
• Near heat sources;
• In areas where oil can splash;
• In areas exposed to direct sunlight;
• In areas where splash water can occur;
• Near bathtubs, in washrooms, near showers or swimming pools.
• Never insert your fingers or other objects into the ventilation openings. Ensure
children are explicitly warned to not do this.
•Ensure that the appliance is positioned upright (vertically) during both transport
and storage so that the compressor is correctly positioned.
• Always turn off the appliance before cleaning and unplug it from the wall outlet.
• Switch off the appliance before moving it and unplug it from the wall outlet. Move
the appliance slowly and carefully.
• To avoid the risk of fire, do not cover the appliance.
• Do not overload the power outlet by operating the appliance simultaneously with
too many powerful electrical appliances.
•All fan connections must comply with local electrical safety regulations. If
necessary, refer to these regulations.
•If the power cord or plug is damaged, it must be replaced by the manufacturer, an
authorised specialist company or a similarly qualified person.
•Children over the age of 8 and persons with reduced physical, sensory or mental
capabilities or those with a lack of experience and knowledge may only use the
appliance if they are instructed on how to do so by a person responsible for their
safety or if they are supervised and understand the hazards associated with the use
of the appliance. Children may not clean or carry out user maintenance without
supervision. Supervise children so that they do not play with the unit.
• Never drink condensation water that leaks from the appliance.
• The appliance must be installed in accordance with national wiring regulations.
• Do not pull the power cord, deform or modify it or immerse it in water. Incorrect
handling of the power cord may result in damage to the equipment and/or electric
shock.
•National gas regulations must be observed. If gas leakage should happen, open
the window for ventilation before running the appliance.
• Do not block the ventilation openings.
• Do not operate the appliance solely by inserting or removing the power plug, as this
may result in electric shock or fire due to heat.
•Immediately unplug the appliance from the wall outlet if it emits strange noises,
odours or smoke.
Instructions for handling damage
WARNING:Risk of injury! Repairs to the coolant circuit may only be carried
WARNING:Risk of fire! This device contains the flammable refrigerant
source, there is a risk of fire.
•In case of damage to the device, cease use immediately, turn off the power, unplug
the power cord, and contact help.kogan.com for support.
•Do not use again until it has been approved by a representative of the
manufacturer.
• The power cord must be securely earthed.
• If the power cord is damaged, turn off the power to avoid danger and unplug the
power cord from the wall outlet. The power cord must be replaced by the
manufacturer, customer service or a similarly qualified person. Do not repair
yourself.
out by trained specialist personnel. Never attempt to repair the unit yourself!
Information for rooms with refrigerant pipes
• Limit the piping to a minimum.
• Be careful not to damage the piping.
• Appliances with flammable refrigerants may only be installed in a well-ventilated
room.
• Comply with national gas regulations.
• All mechanical connections must be freely accessible for maintenance purposes.
R290. If the refrigerant escapes and is exposed to an external ignition
1
2
Air Inlet (Down)
3
Control Panel
4
5
Handle
Air Outlet Louver
Caster wheels
6
7
8
Hot Air Outlet
9
Drainage Nozzle
10
Air Inlet Grille
Remote control
Air Inlet (Up)
11
Exhaust Duct Assembly
12
Window Sealing Plate Assembly
Control Panel Functions
1. POWER button
Press this button to switch the air conditioning on and off.
2. MODE button
Press this button to select one of the three modes: COOL (cooling mode), FAN
and DRY (dehumidification mode).
3. TEMP/TIME - Temperature and time adjusting buttons
Press the button in cooling mode to increase or decrease the temperature.
Press the button in timer mode to set the ON/OFF time of the timer.
Press the + and - (Up and Down) buttons simultaneously to toggle between
degrees Celsius (°C) and degrees Fahrenheit (°F)
4. FAN - Speed button
Press this button to set the high, medium or low speed level. Hold the Fan button.
down for 3 seconds to enter WiFi pairing mode for Kogan SmarterHome
connection.
5. TIMER button
Press this button in standby mode to set the start time.
Press this button in the timer start mode to set the timer end time.
6. Temperature/time display window
This window displays the set temperature and time.
Remote Control Functions
1. Temperature/time display window
This window displays the set
temperature and time.
2. POWER button
Press this button to switch the air
conditioning on and off.
3. MODE button
Press this button to select one of the
three modes: COOL (cooling mode),
FAN and DRY (dehumidification mode).
4. UP button
Press the button in cooling mode to
increase the temperature. Press the
button in timer mode to raise the
ON/OFF time of the timer.
5. DOWN button
Press the button in cooling mode to
decrease the temperature. Press the
button in timer mode to lower the
ON/OFF time of the timer.
6. FAN - Speed button
Press this button to set the high,
medium or low speed level.
7. Temperature unit switch button
Press this button on the remote control
to toggle between degrees Celsius (°C)
and degrees Fahrenheit (°F).
8. SWING button
Press this button on the remote control
to set the swing function.
9. TIMER button
Press this button in standby mode to
set the start time.
Press this button in the timer start
mode to set the timer end time.
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.