When part of the document needs to be revised, the document has advanced revision number.
The document No. is indicated at the lower right side on the cover and at the left or right side of the
footer region of each page.
For copy and transcription of this Operation Manual (hereinafter referred to as this manual),
permission from Koden is needed. Koden prohibits the un-authorized copy and transcription of this
manual.
If this manual is lost or damaged, consult a dealer of Koden or Koden.
The specification of the products and the contents in this manual are subject to change without
notice.
The contents displayed on the menu of product may be different from the expression of this
manual. The fonts and shapes of the keys and menus in the illustration may differ from the actual
ones, and some parts may be omitted.
Koden is not liable for damages and troubles arisen from misunderstanding of the contents in this
manual.
Koden is not liable for any damages caused by earthquake, lightning, wind and flood damage and
fire for which Koden is not responsible, and actions by third parties, other accidents, customer’s
unintended error/abuse and the use under other abnormal conditions.
Koden is not liable for damages of accompaniment (change/loss of memorized content, loss of
business profit, stop of business) arisen from use or failure of our products.
If the stored data are changed or lost, irrespective of causes of troubles and damages, Koden is
not liable for them.
Koden is not liable for any damages arisen from malfunction caused by combination of software
and connected equipment in which Koden is not engaged.
ii 0093169010-10
MDC-7000/7900 Series For Your Safe Operation
Symbol
Meaning
Warning Symbol
This symbol denotes that there is a risk of death or serious injury when not
dealt with it correctly.
High Voltage Danger Symbol
This symbol denotes that there is a risk of death or serious injury caused
by electric shock when not dealt with it correctly.
Caution Symbol
This symbol denotes that there is a risk of slight injury or damage of device
when not dealt with it correctly.
Prohibition Symbol
This symbol denotes restriction of the specified conduct. Description of the
restriction is displayed near the mark.
IMPORTANT
Important Symbol
This mark indicates important area where attention is needed. This may
include possible data lose or other issues that may interfere with radar
operation.
Reference Symbol
This mark shows the part to be referred to concerning this description.
For Your Safe Operation
Symbols used in this Operation Manual
This manual uses the following symbols. Understand the meaning of each symbol and implement the
maintenance and inspection.
0093169010-10 iii
For Your Safe Operation MDC-7000/7900 Series
Caution, high voltage inside.
High voltage that may cause severe injury or death is present. High
voltage remains in circuit even after power is turned off. High voltage
circuit has a protective cover with a warning label. Make sure to turn off
power and discharge capacitors before working on the system. Only
authorized personnel should access this circuit for repair and
maintenance.
Confirm main power is turned off before servicing the
equipment.
If power switch is turned on while working on the system, possible
severe injury or death may occur due to high voltage. Make sure main
power is off and a label “Work In Progress” is attached to the breaker
powering the system.
Caution related to dust
Inhaling dust may cause A respiratory disease. When cleaning the inside
of equipment, be careful not to inhale dust. Wearing a safety mask is
recommended.
When choosing equipment location
Do not install the equipment where it is excessively damp, humid and
under direct dripping water.
Caution related to static electricity
Static electricity may be generated from floor carpet or synthetic clothes.
Static may destroy some electronics parts of the circuit and therefore
anti-static measures should be done.
Prohibited matter
Any Display and Scanner unit combination other than specified in the
manual is prohibited and will void manufacturer’s warranty.
Caution related to Equipment
iv 0093169010-10
MDC-7000/7900 Series For Your Safe Operation
Caution related to rotating aerial
The radar antenna may start rotating to rotate without notice. Please stand
clear from the antenna for your safety.
Caution related to electromagnetic disturbance
The operating Antenna & Scanner unit radiates high-energy
electromagnetic wave. It may cause harmful effect for human body due to
its continuous radiation. As International regulation says, electromagnetic
waves less than 100 watt/m2 does not have a harmful effect on human
bodies, but some kind of medical devices such as heart pacemakers are
sensitive even under the low energy electromagnetic wave. Any personnel
with such a device should keep away from the electromagnetic wave
generating position at all times.
Specified power density and distance from the radar (in accordance with the
provision as specified in IEC 60945)
Model name
Transmission power /
Antenna length
100W/m2
50W/m2
10W/m2
MDC-7060
MDC-7960
6kW / 4 feet Antenna
1.5 m
2.1 m
4.5 m
6kW / 6 feet Antenna
1.7 m
2.4 m
5.4 m
MDC-7010
MDC-7910
12kW / 4 feet Antenna
2.1 m
2.9 m
6.4 m
12kW / 6 feet Antenna
2.4 m
3.4 m
7.6 m
12kW / 9 feet Antenna
2.9 m
4.1 m
9.0 m
MDC-7020
MDC-7920
25kW / 4 feet Antenna
2.9 m
4.1 m
9.2 m
25kW / 6 feet Antenna
3.5 m
4.9 m
10.9 m
25kW / 9 feet Antenna
4.1 m
5.8 m
13.0 m
Caution rellated to Handling
0093169010-10 v
For Your Safe Operation MDC-7000/7900 Series
Do not disassemble or modify. It may lead to trouble, fire, smoking or
electric shock. In case of trouble, contact our dealer or our company.
In case of smoke or fire, switch off the power in the boat and the power of
equipment. It may cause fire, electric shock or damage.
Caution related to remaining high voltage.
A high voltage may remain in the capacitor for several minutes after
system is powered off. Before inspecting inside, wait at least 5 minutes
after powering off or discharging the remaining electricity in an appropriate
manner. Then, start the work.
The information displayed in this unit is not provided directly for your
navigation. For your navigation, be sure to see the specified material.
Use properly rated fuse. If incorrect fuse is used, it may cause fire, smoke
or damage.
vi 0093169010-10
MDC-7000/7900 Series Break in procedure of stored radar
Following procedure is recommended for “Break In” of the stored radar.
Otherwise the radar sometimes exhibits unstable transmitting operation
such as arcing at its initial operation after long period of storage and make
the operation more difficult.
1. Extend preheat time as long as possible (preferably 20 to 30
minutes).
2. Set the pulse width to the shortest one and start the operation.
When the operation in the shortest pulse is stable then go to
operation in longer pulse and repeat the similar step until the
operation reaches to the final pulse condition.
Break in procedure of stored radar
0093169010-10 vii
Used battery and radar disposal MDC-7000/7900 Series
A high-energy density lithium ion battery is installed in this radar.
Improper disposal of a lithium ion battery is discouraged as the battery
has a possibility of short-circuiting. If it gets wet, the generation of heat,
explosion or ignition may occur resulting in an injury or fire.
Used battery and radar disposal
Treatment of the used lithium ion battery
To dispose of built-in lithium ion battery (CR2032) in this radar, insulate each terminal with tape, and
wrap in plastic bag.
The disposal and collection rules may be different depending on each municipal district. Obey the
directions of each district.
Disposal of this radar
This radar shall be disposed according to the municipal regulations or rules.
viii 0093169010-10
MDC-7000/7900 Series In case no Heading and Speed signals
In case no Heading and Speed signals are input from navigation
equipment
When no Heading and Speed signals are input from navigation equipment (in case not connected), this
radar gives alarms and warning messages at lower right of the display, if the radar is started up factory
default settings.
These alarms are disengaged by pressing OFF key temporarily, however, the alarms are activated
again next time the radar is start up.
Disengage the alarm detection function on start up by the following. Once set, the alarm is not detected
next time the radar is started up.
Press MENU key to display “Menu”.
Select [ALARM] => [ALARM ON/OFF] => [I/O] => [HDG INPUT] => [OFF], and press ENT key.
Select [ALARM] => [ALARM ON/OFF] => [I/O] => [SPD INPUT] => [OFF], and press ENT key.
Select [ALARM] => [ALARM ON/OFF] => [I/O] => [LAT/LON INPUT] => [OFF], and press ENT key.
Select [MAINTENANCE] => [I/O] => [TIME] => [TIME] => [CLOCK], and press ENT key.
0093169010-10 ix
Contents MDC-7000/7900 Series
Contents
Document Revision History ........................................................................................................ i
Important Notice ........................................................................................................................ ii
For Your Safe Operation .......................................................................................................... iii
Break in procedure of stored radar ......................................................................................... vii
Used battery and radar disposal ............................................................................................ viii
In case no Heading and Speed signals are input from navigation equipment ......................... ix
Contents ................................................................................................................................... x
Introduction ........................................................................................................................... xviii
Configuration items ................................................................................................................ xix
System configuration ................................................................................................. xix
Option list .................................................................................................................... xx
Chapter 1 Display and Operation ............................................................................. 1-1
11.5.1 NAV and EPFS serial data input/output specification ................................ 11-29
11.5.2 SDME serial data input/output specification .............................................. 11-30
11.5.3 VDR (external monitor) and Alarm output signal specification .................. 11-31
xvi 0093169010-10
MDC-7000/7900 Series Contents
11.5.4 Serial data input/output specification (AIS) ............................................... 11-32
11.5.5 Radar input/output signal specification ..................................................... 11-33
11.5.6 Talker device code of the data output devices .......................................... 11-34
11.5.7 Priority of talker device code ..................................................................... 11-34
Chapter 12 Index ................................ ................................ ................................ ....12-1
0093169010-10 xvii
Introduction MDC-7000/7900 Series
xviii
Introduction
The MDC-7060/7010/7020/7960/7910/7920 type Radar system is a compact and high performance
shipboard radar system consisting of the Antenna & Scanner unit with a transmit power of
6kW/12kW/25kW, a Display unit with a 19 inch color LCD (Liquid Crystal Display) and Operation unit.
For this radar, its multi functions and high performance are accomplished with microcomputer
technology as well as an image processing in the newly developed radar-dedicated LSI (Large Scale
Integration).
A slim Display unit using liquid crystal technology.
Stable indication and reliable acquisition of small targets.
Clear distinction between a moving target and land by true trail display.
Provision of multi targets TT (ARPA) information and AIS information.
Various models for selection of optimum radar for your needs.
Capable of adjusting gain, anti- sea clutter, anti- rain clutter, bearing cursor, and range marker, etc.
using rotating knobs.
The waterproof operating panel (IP23) has a great flexibility in installation.
Capable of remote control using USB Mouse/Trackball.
Simple and easy operation by user-friendly rotating knobs.
With 6-pin water resistant connectors at both
ends (cable for data)
8
CW-374-5M
With a 6-pin connector and a 6-pin water
resistant connector (cable for data)
9
CW-376-5M
With a 6-pin water resistant connector and one
end plain (cable for data)
10
CW-387-5M
With a 8-pin water resistant connector and one
end plain (cable for AIS)
11
CW-561-*
*: 10M, 30M
With 12-pin water resistant connectors at both
ends (cable for remote display)
12
CW-576-0.5M
With a 10-pin water resistant connector and
D-Sub connector (analog RGB)
+Alarm out
13
Operation unit
connecting cable
CW-401-*
*: 5M, 10M
With connectors on both sides
14
Antenna unit –
Display unit
connecting cable
242J159098C-20M
With connectors on both sides
15
242J159098D-30M
With connectors on both sides
16
242J159098x-xxM
xx: 100 m max
With a connector on the both sides
Option list
0093169010-10
MDC-7000/7900 Series Chapter 1 Display and Operation
1-1
Range scale
Range Rings
MODE
STAB
Off center
Day/Night
Pulse width
TX/Standby
Frequency band
Picture freeze
detection
REF position number 1-4
REF position CCRP/ANT
When there is not alarm information, this
area can display the graph of navigation
data.
EBL1
Upper left corner
Upper right corner
Lower left corner
Lower right corner
Own ship
data
Target
status
Target and
MAP
Information
area
Assistant
display
(Navigation
Information)
Alarm
display
(Nav graph)
area
Heading
line
ERBL
EBL2
(OFFSET)
Range Rings
VRM1
VRM2
PI
PI
PI
PI
Alarm
status
Chapter 1 Display and Operation
1.1 Radar Display
Upper left corner
0093169010-10
Chapter 1 Display and Operation MDC-7000/7900 Series
1-2
ERBL data
Cursor position data
VRM1 distance
VRM2 distance
Distance of selected No.4 PI
Inter-switch mode
TUNE setting
GAIN setting
SEA setting
RAIN setting
PICTURE setting
PROCESS setting
EXPANSION setting
VIDEO mode setting
Sector MUTE ON
MAP function display
TRAIL TRUE/REL
TRAIL TIME
Own Ship Past Track ON
EBL1
EBL2
EBL1 active mark
EBL bearing
Offset EBL move mode TM/RM
Selected PI
Active PI
Bearing of
selected PI
Upper right corner
Lower left corner
Lower right corner
0093169010-10
MDC-7000/7900 Series Chapter 1 Display and Operation
1-3
UTC/LOCAL TIME
Date
Day/Month/Year
Time
Heading
CTW or COG
STW or SOG
Set and Drift
Own ship position
Vector Time
Vector REL/TRUE
Limit CPA
Limit TCPA
AIS and TT Lost Alarm
Association setting
AIS ON
TT ON
AIS and TT Past position
Indication Mode REL/TRUE
Indication Time
Activity AIS Filter Icon
Indication AtoN AIS
AIS Auto Acquisition
by CPA/TCPA
AIS Auto Acquisition
by Range (0.0NM to 64.0NM)
Own ship data
Target status
0093169010-10
Chapter 1 Display and Operation MDC-7000/7900 Series
1-4
Change TT shape
Cursor and press ENT key.
Edit LAT/LON data
Change Color
Deletion of indication data
Line indication between own ship
position and marker point.
Comment input
Target and MAP information area
Selected AIS, TT or MAP (COAST LINE, NAV LINE, ROUTE, EVENT MKR and AREA) information is
displayed, this data can be changed by selecting with cursor and pressing ENT key.
0093169010-10
MDC-7000/7900 Series Chapter 1 Display and Operation
1-5
NAV INFO
TGT OUTLINE
TGT LIST CPA/TCPA
TGT LIST BRG/RNG
TGT LIST LAT/LON
TGT LIST COG/SOG
TGT LIST LABEL
SELECTED AIS INFO
BIRDVIEW
WIDEVIEW
ZOOMVIEW
Assistant display (Navigation information)
Selection values are NAV INFO, TGT OUTLINE, TGT LIST (CPA/TCPA), TGT LIST (BRG/RNG), TGT
LIST (LAT/LON), TGT LIST (COG/SOG), TGT LIST (LABEL), SELECTED AIS INFO, BIRDVIEW,
WIDEVIEW and ZOOMVIEW.
TGT LIST can be sorted by CPA, TCPA, RNG, TGT and SEL
CPA: It is displayed with the nearest first from the top of display.
TCPA: It is displayed with the shortest first from the top of display.
RNG: It is displayed with the nearest first the top of display
TGT: It is displayed with the nearest to the selected target first from the top of display.
SEL: It is displayed with the selected target first from the top of display.
0093169010-10
Chapter 1 Display and Operation MDC-7000/7900 Series
1-6
Active
Unacknowledged alarm
Active
Silenced alarm
Active
Acknowledged alarm
Active
Responsibility transferred alarm
Rectified
Unacknowledged alarm
Category (A, B or C)
Alarm ID (0 to 9999: Specified by the IMO,
10000 to 9999999: Peculiar to a maker)
Time of alarm occurrence
ID of cause device, Source of alarm
Alert management
icons
Message
ALARM A 9999999
UTC 15 / 10 / 14 16:23
RADAR RADAR 1
MESSAGE
Priority
Alarm display area
When a malfunction or operation error has been detected in the radar, alarm message will appear at
the alarm display area.
Abnormalities are categorized as [ALARM], [WARNING] and [CAUTION]. When these messages
actually appear and there is something wrong with radar, record the alarm details by type, location and
status and press OFF key. The alarm sound (when ALARM and WARNING) and display will disappear.
Multiple errors may be displayed one by one. Record all alarms and press OFF key for every alarm.
Alarm list: Refer to 9.8 About alarms “Alarm list”.
ALARM (Displayed with red)
In case of unacknowledged alarm, icon and ALARM of priority will be flashing, and 3 short audible
signals will be repeating every 7 sec.
In case of silenced alarm, audible signals will be stopping. If silenced alarm condition keeps more than
30sec. silence alarm condition will cancel.
Type of ALARM icons
0093169010-10
MDC-7000/7900 Series Chapter 1 Display and Operation
1-7
Active
Unacknowledged warning
Active
Silenced warning
Active
Acknowledged warning
Active
Responsibility transferred warning
Rectified
Unacknowledged warning
Caution
WARNING A 9999999
UTC 15 / 10 / 14 16:23
RADAR 1
MESSAGE
CAUTION A 9999999
UTC 15 / 10 / 14 16:23
RADAR RADAR 1
MESSAGE
WARNING (Displayed with yellowish orange)
In case of unacknowledged alarm, icon and WARNING of priority will be flashing, and 2 short audible
signals will be repeating every 60 sec.
Type of WARNING icons
CAUTION (Displayed with yellow)
In case of CAUTION status, icon and CAUTION of priority is not flashing and audible signal is silent.
Type of CAUTION icon
0093169010-10
Chapter 1 Display and Operation MDC-7000/7900 Series
1-8
Alarm icon
Icon name
Setting method (Refer to Chapter 3 Alarm)
Echo alarm
Refer to 3.1 Echo alarm
Map area alarm
Refer to 3.2 Map area alarm
Nav line cross alarm
Refer to 3.4 Nav line cross
Temperature and depth
Wind 1
Wind 2
Set/drift 1
Set/drift 2
Course/ speed 1
Course/ speed 2
Echo level monitor
Own ship position
VRM 1 marker
Selected range marker
Alarm display area (Navigation graph)
Following navigation data graphs can display at alarm display area.
Water temperature and water depth
Wind
Set/drift
Course and speed
Radar echo level monitor
1 Move cursor on the alarm display area with trackball, and press ENT key.
2 Navigation data graph will be displayed as follows.
It is necessary to input MTW sentence to display water temperature.
It is necessary to input DPT or DBT sentence to display water depth.
It is necessary to input MWD sentence to display wind direction and speed.
It is necessary to input VDR sentence to display set and drift.
Echo level monitor shows the signal level of EBL1 direction.
Alarm status
The icon of alarm status will be displayed at the lower left corner of the display.
Alarm icons are displayed only when alarm function is active and they are not displayed when alarm
function is inactive. Alarm icons are displayed in red color while alarm is detected.