Koden CVS-128, CVS-128B Operation Manual

Page 1
Page 2
Declaration of Conformity
(As referred to in Annex IV 2. of Directive 2004/108/EC)
Declares under his sole responsibility that the produced Echo Sounder manufactured by
Koden Electronics Co., Ltd.
5278 Uenohara
Yamanashi-Ken
409-0112, Japan
,
Telephone +81 554 20 5860 Telefax +81 554 20 5875
Identified by the type number relevant essential requirements of Directive 2004/108/EC and is in conformity with the EMC
requirements of EU harmonised standard
CVS-128
to which this declaration refers conforms to the
EN 60945: 2002 (Clauses 9, 10 & 12)
Authorised representative in Europe
Heinz Hoghoff Koden Elektronik GmbH. Am Gewerbepark 15 D-64823, Gross–Umstadt Germany. Phone +49 6078 2056 Telefax+49 6078 73824
Signed Heinz Hoghoff,
Dated 15 April 2009
N.B. As this product is for Maritime use compliance with Directive 72/23/EEC is not required.
Page 3
Declaration of Conformity
(As referred to in Annex IV 2. of Directive 2004/108/EC)
Declares under his sole responsibility that the produced Echo Sounder manufactured by
Koden Electronics Co., Ltd.
5278 Uenohara
Uenohara-Shi
Yamanashi-Ken
,
409-0112, Japan
Telephone +81 554 20 5860 Telefax +81 554 20 5875
Identified by the type number CVS-128B to which this declaration refers conforms to the
relevant essential requirements of Directive 2004/108/EC and is in conformity with the EMC requirements of EU harmonised standard
EN 60945: 2002 ( Clauses 9,10 & 12 )
Authorised representative in Europe
Heinz Hoghoff Koden Elektronik GmbH. Am Gewerbepark 15 D-64823, Gross–Umstadt Germany. Phone +49 6078 2056 Telefax+49 6078 73824
Signed : Heinz Hoghoff,
Dated : 01 Jun. 2012 Document No. 72-2731U-X003
N.B. As this product is for Maritime use compliance with Directive 72/23/EEC is not required.
Page 4
CVS-128/128B Revision History
CVS-128/128B Operation Manual
Doc No. 0093112802
Document Revision History
No. Doc. No-Rev. No. Reviced Date
(Y/M/D) 0 0093112802-00 2009/05/27 First edition 1 0093112802-01 2009/07/09 Chapter 1 2 0093112802-02 2010/01/12 Revision (From software KM-E79* Ver01.03 to Ver01.**)
Revision (From software KM-E79 Ver01.06 to Ver01.**)
3 0093112802-03 2011/04/27
4 0093112802-04 2011/12/26 Important Notice, Chapter 2, Chapter 6 5 0093112802-05 2012/06/15
6 0093112802-06 2013/06/24
7
System Configuration, Configuration of Equipment, Chapter 5, Wording
Added CVS-128B Revision (From software KM-E79 Ver01.08 to Ver01.**) Revision (From software KM-F22* Ver01.02 to Ver01.**) System Configuration, Configuration of Equipment, Chapter 5
Revised Content
8 9
10
*KM-E79: CVS-128, KM-F22: CVS-128B **Subject to version change
Document No. Revised Version Norm
When part of the document needs to be revised, the document has advanced revision number. The document No. is indicated at the lower right side on the cover and at the left or right side of the footer region of each page.
© 2009-2013 Koden Electronics Co., Ltd. All rights reserved. No part of this publication may be reproduced, transmitted, translated in any from by any means without the written permission of Koden Electronics Co., Ltd. The technical descriptions contained in this publication are subject to change without notice. Koden assumes no responsibility for any errors, incidentals or consequential damages caused by misinterpretation of the descriptions contained in this publication.
0093112802-06 i
Page 5
Important Notice CVS-128/128B
Important Notice
For copy and transcription of this Operation Manual (hereinafter referred to as this manual),
permission from Koden is needed. Koden prohibits the un-authorized copy and transcription of this manual.
If this manual is lost or damaged, consult a dealer of Koden or Koden.  The specification of the products and the contents in this manual are subject to change without
notice.
The contents displayed on the menu of product may be different from the expression of this
manual. The fonts and shapes of the keys and menus in the illustration may differ from the actual ones, and some parts may be omitted.
Koden is not liable for damages and troubles arisen from misunderstanding of the contents in this
manual.
Koden is not liable for any damages caused by earthquake, lightning, wind and flood damage and
fire for which Koden is not responsible, and actions by third parties, other accidents, customer’s unintended error/abuse and the use under other abnormal conditions.
Koden is not liable for damages of accompaniment (change/loss of memorized content, loss of
business profit, stop of business) arisen from use or failure of our products.
If the stored data are changed or lost, irrespective of causes of troubles and damages, Koden is
not liable for them.
Koden is not liable for any damages arisen from malfunction caused by combination of software
and connected equipment in which Koden is not engaged
.
ii 0093112802-06
Page 6
CVS-128/128B For Your Safe Operation
For Your Safe Operation
Pictorial used in this Operation Manual
This Operation Manual uses the following pictorials. Understand the meaning of each pictorial and implement the maintenance and inspection.
Symbol Meaning
Mark for warning
This symbol denotes that there is a risk of death or serious injury when not dealing with it correctly.
Mark for danger high voltage
This symbol denotes that there is a risk of death or serious injury caused by electric shock when not dealing with it correctly.
Mark for caution
This symbol denotes that there is a risk of slight injury or damage of device when not dealing with it correctly.
Mark for prohibition
This symbol denotes prohibition of the specified conduct. Description of the prohibition is displayed near the mark.
Caution Item on Equipment
Be careful of a high voltage inside.
A high voltage, which may risk your life, is used. This high voltage remains in the circuit after you have powered off switch. To prevent touching the high voltage circuit inadvertently, the hard cover is provided to the high voltage circuit and the high voltage caution label is affixed. Ensure to power off switch for your safety and discharge the electricity remaining in the capacity before starting to check. An engineer authorized by our company should inspect and maintain
Be sure to power off in the boat.
If the power switch is inadvertently powered on during work, you will be electrified. To prevent such accident from occurring, ensure to power off in the boat and the power of equipment. Furthermore, it is safer to hang the caution tag described as [Under Work] near the power switch of equipment.
Be careful of dust
Inhaling dust may cause A respiratory disease. When cleaning the inside of equipment, be careful not to inhale dust. Wearing a safety mask is recommended.
0093112802-06 iii
Page 7
For Your Safe Operation CVS-128/128B
Caution on location of equipment
Do not install the equipment where it is excessively damp and suffers from excessive water drops.
Escaping from static electricity
The static electricity may be generated from the carpet on the floor in the cabin or clothes made of synthetic fiber . The static electricity may destroy the electronic parts on the circuit board. Handle the circuit board, taking the measure of static electricity free.
Install the transducer at the location where it is not affected by bubble and noise The bubble and noise seriously degrade the performance of this unit.
Caution Item on Handling
Do not disassemble or modify. It may leads to trouble, fire, smoking or electric shock. In case of trouble, contact our dealer or our company.
In case of smoke or fire, boat power off and the power of this unit. It may cause fire, electric shock or damage.
Be cautious of remaining high voltage. A high voltage may remain in the capacitor for several minutes after you have powered off. Before inspecting inside, wait at least 5 minutes after powering off or discharge the remaining electri city in an appropriate manne r . Then, start the work.
The information displayed in this unit is not provided directly for your navigation. For your navigation, be sure to see the specified material.
Use the specified fuse. If un-specified fuse is used, it may cause a fire, smoke or damage.
Whenever transmitting, be sure to submerge the transducer in water first. If transmitted without submerging the transducer, it may be dama ged.
iv 0093112802-06
Page 8
CVS-128/128B Contents
Contents
Document Revision History ....................... i
Important Notice ....................................... ii
For Your Safe Operation ......................... iii
Contents ................................................... v
Introduction ................................................ ix
System Configuration ................................. x
Configuration of Equipment ....................... xi
Change the frequency ............................. xiv
Chapter 1 Basic Operation ...................... 1-1
1.1 How to use the key .................... 1-1
How to remove the hard cover ... 1-2 When removing the
CVS-128/128B Display unit ....... 1-2
The clean of CVS-128/128B
Display unit ................................ 1-2
1.2 Power On/Off ............................. 1-3
Power on .................................... 1-3
Power off .................................... 1-3
Alarm of Power Voltage ............. 1-3
1.3 LCD Brilliance Adjustment ......... 1-4
Adjustment of LCD Brilliance ..... 1-4
Brightness Adjustment of Panel
Brilliance .................................... 1-4
1.4 Switch-over of Display mode ..... 1-4
Normal Image (Low frequency,
High frequency) .......................... 1-4
Dual frequency ........................... 1-5
Zoom (Low frequency, High
frequency) .................................. 1-5
Navigation Menu (NAV1, NAV2) 1-7
1.5 Selection of NAV Display ........... 1-8
Type of NAV Display .................. 1-8
Selection of NAV Menu .............. 1-8
1.6 Switch-over of Range ................ 1-9
Setting the range switching to auto
range .......................................... 1-9
Setting the range switching to
Manual range ............................. 1-9
1.7 Setting of Shift ............................ 1-9
Setting of Manual Shift ............... 1-9
Release of manual Shift ........... 1-10
Setting of Auto Shif t ................. 1-10
1.8 Gain Adjustment ....................... 1-10
Basic Operation of Gain ........... 1-11
Selecting the auto gain ............ 1-11
Adjusting the gain by auto ....... 1-11
Selecting the manual gain ....... 1-11
Manual adjustment of the gain . 1-11
1.9 Use of [EVENT] key ................. 1-12
Selecting the event key function1-12
Presetting the waypoint ........... 1-12
Store the image ........................ 1-13
Fishing hot spot ........................ 1-13
1.10 Use of [F1] / [F2] key ................ 1-14
Selecting the
[F1] / [F2] key ......................... 1-14
Preset of [F1] / [F2] key ........... 1-14
1.11 Operation of VRM .................... 1-15
1.12 Display of fish information ........ 1-15
Display the fish symbol /Stop the
display of fish symbol ............... 1-16
Selecting the symbol info ......... 1-16
Fish symbol detection
adjustment ............................... 1-16
Size adjustment ....................... 1-16
Big fish / Big fish color ............. 1-17
Points to note in use of fish
symbol ...................................... 1-17
Chapter 2 How to use the Menu ............. 2-1
2.1 How to operate the menu .......... 2-1
0093112802-06 v
Page 9
Contents CVS-128/128B
Display the menu / Stop the
display of menu .......................... 2-1
Menu Operation ......................... 2-1
2.2 Changing of Image Speed.......... 2-2
2.3 Rejection of Interference ............ 2-2
Interference Rejection ................ 2-2
2.4 Color Rejection of Weak Echo ... 2-3
Color Rejection ........................... 2-3
2.5 Rejection of Noise ...................... 2-3
Noise Rejection .......................... 2-3
2.6 Setting of Shift step .................... 2-3
2.7 Selection of Zoom ...................... 2-3
2.8 Setting of Zoom Range .............. 2-4
2.9 Setting of Zoom Start ................. 2-4
2.10 Preset of Range ......................... 2-4
Easy registration method of
the range .................................... 2-5
TM
Switch-over of Sona-Tone Connection of External
Speaker .................................... 2-12
2.17 Explanation of Menu Item ........ 2-12
Inner-hull .................................. 2-12
TVG .......................................... 2-13
Change the TX power .............. 2-13
Change the Pulse width ........... 2-13
Change the Bandwidth ............. 2-14
D. Range .................................. 2-14
Display Width ........................... 2-14
Display the A scope / Stop the
display of A scope .................... 2-14
Change the display color of echo
sounder image ......................... 2-14
Change the depth value ........... 2-15
Display the depth unit / Stop the
..... 2-12
2.11 Setting of Background Color ...... 2-5
2.12 Setting of White Line .................. 2-5
2.13 Setting of Alarm .......................... 2-6
Stopping the alarm sound .......... 2-6
Setting the alarm ........................ 2-7
Release the alarm ...................... 2-7
Confirm the alarm state .............. 2-7
2.14 Preset/ WPT edit/ WPT delete of
Waypoint .................................... 2-8
NAV Start .................................... 2-8
Cancel the NAV .......................... 2-8
Edit the destination ..................... 2-8
Delete the waypoint .................... 2-9
Recall the stored image and
preset it as a destination ............ 2-9
2.15 Store/Recall/ Deletion of Image 2-10
Store the image ........................ 2-10
display of depth unit ................. 2-15
Display the water temp graph / Stop the display of water temp
graph ........................................ 2-15
Setting of the background color of
NAV display .............................. 2-15
Setting of the echo sounder
display at NAV display .............. 2-15
Image Swap ............................. 2-15
Display the Operation guide / Stop the display of Operation
guide ......................................... 2-15
Display the detection area / Stop the display of detection
area .......................................... 2-16
Setting of Scale display ............ 2-16
Change the scale value ............ 2-16
Recall the stored image ........... 2-10
Delete the stored image ........... 2-11
Add the comment to the stored
image ........................................ 2-1 1
2.16 Explanation of Sonar ................ 2-12
vi 0093112802-06
Change the image direction ..... 2-16
Setting of Depth measurement 2-16
Change the display color.......... 2-16
Setting of Key lock ................... 2-17
Change the scale type ............. 2-17
Page 10
CVS-128/128B Contents
Change the bottom color ......... 2-17
Change the image partition ...... 2-17
Display the frequency / Stop the
display of frequency ................. 2-17
Selecting a display area of fish
symbol indication ..................... 2-17
Chapter 3 How to use the menu2 ............ 3-1
3.1 Display of Menu ......................... 3-1
Display the menu ....................... 3-1
Return to the normal menu ........ 3-1
3.2 Setting of External Input/Output . 3-1
Buzzer Setting ............................ 3-1
Temp Source .............................. 3-1
Speed Source ............................ 3-1
Baud Rate .................................. 3-1
NMEA Monitor ............................ 3-2
NMEA Output Data .................... 3-2
All WPTs deletes ........................ 3-4
All stored image deletes ............ 3-4
Bottom start ................................ 3-4
Past image ................................. 3-4
Inner-hull .................................... 3-4
TD select .................................... 3-4
3.6 Setting of Adjust2 Item ............... 3-4
STC strength adjust Low / High . 3-4
STC depth adjust Low / High ..... 3-4
Color adjust ................................ 3-5
Image speed adjust.................... 3-5
Bottom limit ................................ 3-5
Sounding .................................... 3-5
3.7 Frequency select ........................ 3-5
Frequency select (Low / High) ... 3-5
Power frequency adjustment ..... 3-5
Chapter 4 Maintenance and Inspection .. 4-1
3.3 Setting of Correction Item .......... 3-2
Draft Set ..................................... 3-2
Sonic Speed ............................... 3-2
Water Temp ................................ 3-2
Boat Speed ................................ 3-2
Directivity angle (Low/High) ....... 3-2
Bubble ........................................ 3-3
Bubble time set .......................... 3-3
3.4 Setting of Basic Set Item ........... 3-3
Language ................................... 3-3
Range & Speed Unit .................. 3-3
Depth Unit .................................. 3-3
Temperature Unit ....................... 3-3
Local time Offset ........................ 3-3
GPS select ................................. 3-3
GPS initialize .............................. 3-3
3.5 Maintenance Menu .................... 3-3
Simulation .................................. 3-3
Slide show .................................. 3-4
Initialize ...................................... 3-4
System Check ............................ 3-4
4.1 Inspection ................................... 4-1
4.2 Cleaning ..................................... 4-1
CVS-128/128B Display unit ....... 4-1
Transducer ................................. 4-1
4.3 Fuse Replacement ..................... 4-2
4.4 If you suspect a trouble .............. 4-2
4.5 Diagnostic Test ........................... 4-3
Diagnose .................................... 4-3
Confirm the version .................... 4-3
Return to the menu .................... 4-3
Chapter 5 Installation .............................. 5-1
5.1 Items of Caution on Installation . 5-1
Unpacking the components ....... 5-1
Inspection of components and
accessories ................................ 5-1
Decision of Installing Location ... 5-1 Laying and Connection of Cable 5-2
Confirmation after Installation .... 5-2
5.2 Installation of CVS-128/128B
Display unit ................................ 5-3
Desk-top Installation .................. 5-3
0093112802-06 vii
Page 11
Contents CVS-128/128B
Flush-mount Installation ............. 5-5
5.3 Installation of Transducer ........... 5-6
In case of Inner-hull .................... 5-6
In case of Through hull ............... 5-7
5.4 Wiring ......................................... 5-8
Connection of Cable to
CVS-128/128B Display unit........ 5-8
Pin Assignment of Rear
Connector ................................... 5-8
Connection of Power Cable ....... 5-9
Connection of Transducer ........ 5-10
Connection with external
equipment................................. 5-1 1
Connection with GPS-20A ....... 5-11
Connection with Speed Senso r or Water Temperature Sensor
(Option) .................................... 5-12
Connection of External Speaker
TM
for Sona-Tone
(Prepared by a customer) ........ 5-13
Connection of External Monitor (J7) (Prepared by a customer) . 5-13
5.5 Serial Data ................................ 5-14
Input Data ................................. 5-14
Output Data .............................. 5-14
Chapter 6 Table Attached ........................ 6-1
6.1 Menu List .................................... 6-1
6.2 Specification ............................... 6-5
6.3 Appearance ................................ 6-7
viii 0093112802-06
Page 12
CVS-128/128B Introduction
Introduction
The CVS-128/128B is a Dual frequency Color LCD display echo sounder. This unit equipped with digital process displays the circum stance in the water under all conditions,
matching with the high luminance 8.4 inch LCD. The main features of this unit are as follows: With the digital reception process, the compatibility of the high resolution in a shallow depth and the
noise rejection capability in a deep depth are established. The auto mode function provides the best image.
The high-performance LCD maint ains high visibility under any conditions. The unit can be installed in an open b rid ge and is highly waterproof. Sona-Tone (Sonar sound) functio n is equipped with for catching situations schools of fish and
others by sound.
Up to 10 images can be stored. If you connect the optional GPS, the fishing hot spot function, that
directs your boat to navigate easily to the location desired, is available by marking the event mark when recalling the stored image.
With the adoption of a specific filter (AR coat), an image can be seen clearly, refusing sunshine.
The countermeasures against the reflection on the LCD screen and dew are provided.
The various alarm functions are available. (Bottom, scho ol of fish, water tempe rature*, boat speed*,
arrival*, XTE*, power) (Note: The mark * denotes that the connection of option is mandatory)
When flush-mounting, the unit can be easily installed from front side. The RGB output for an external monitor is provided a s standa rd eq uipment. The use of the external
monitor enables you to observe easily the echo sounder scree n at a location which is remote f rom a main unit. (External monitor: Prepared by a customer)
CVS-128B is the high sensitivity model with broadband transducer. This model can be used at your
optimum frequencies within the specification of the broadband transducer. You can set 2 frequencies depending on a target fish or intended purpose du ring operation.
0093112802-06 ix
Page 13
System Configuration CVS-128/128B
y)
r
r
r
r
r
/
r
System Configuration
Connection Diagram
To Transducer connector
(J6 connector)
CVS-128/128B Display unit
With mounting bracket and hard cove
To POWER connector
To External monitor connector
CW-264A-2M
CW-840-0.3M
(J7 connector)
CW-576-0.5M
External power output (For GPS etc)
External speaker (For speaker with amplifier)
NMEA circuit input output External navigation equipment, external water temperature mete
Red
+
Black
-
Legend
Standard configuration Option
Owner supply
(Owner supply)
10.8 to 31.2VDC
External monitor
(Owner supply)
Connection to the Transduce
Connection to the speed sensor Connection to the wate
Temperature
Note: To use the water temperature sensor / speed sensor,
The wiring of transducer connector has to be changed.
Water temperature senso
speed senso
ST-80/90/100
CVS-128
Transducer P66 (Dual frequency combination type 50 / 200 kHz) Plastic made. Equipped with Transom. (Owner suppl
CVS-128 Transducer TD-501C (Dual frequency combination type 50 / 200 kHz)
Rubber mold made. Equipped with Inner-hull/Ship’s bottom/Ship’s side. Transducer TD-500T-3B / 501T-3B (Dual frequency combination type 50 / 200 kHz)
Bronze made. Equipped with Through-hull. Transducer TD-500T-2B (Dual frequency combination type 50 / 200 kHz)
Plastic made. Equipped with Inner-hull.
CVS-128B
Transducer TDM-071 (38 to 75 kHz)
Transducer TDM-091D (42 to 65 kHz) (130 to 210 kHz)
Urethane mold made. Equipped with Ship’s bottom/Ship’s side
x 0093112802-06
Page 14
CVS-128/128B Configuration of Equipment
Configuration of Equipment
Standard Equipment Configuration List
No. Name of item Type Remark
1 Display unit
CVS-128/128B With mounting bracket
and knob
Weight/
Length
3.2 kg 1
Quantity
2 Hard cover
3 DC power cable
(Combined cable)
4 Fuse
5 Cap
E57MB11060 250 g 1
CW-264A-2M With 12 connector at
one end/ un-treated at the other end
F-7161-3A Cylinder (ø 6.4x30)
LTWCAP-DABCFXC1 For transducer cable
Normal fusion type for main power
connector
2 m 1
2
1
6 Operation Manual CVS-128.OM.E English 1 7 Quick Reference CVS-128.QR.E English 1 8 Cautionary Note CVS-SER.RM.E English 1
Essential Option
No. Name of item Type Remark
1 Transducer Type of transducer transducer cable (with
connector at one end)
Weight/
Length
1
Quantity
0093112802-06 xi
Page 15
Configuration of Equipment CVS-128/128B
Type of transducer
No. Specification Frequency Material /
Length of the
cable
1
TD-500T-2B
CVS-128 50/200 kHz
600 W
Plastic 9m
TD-500T-3B
2
CVS-128 50/200 kHz
Bronze 9m
600 W
3
TD-501C
CVS-128 50/200 kHz
1 kW
Rubber mold
10m
Mounting method Beam width
(Right and left x
back and forth)
Inner-hull
50kHz
50°x50° ( -6dB)
200kHz
17°x17° ( -6dB)
Through-hull 50kHz
50°x50° ( -6dB)
200kHz
17°x17° ( -6dB)
Inner-hull/ Ship’s bottom/ Ship’s side (The CW-840-0.3M is needed)
50kHz
58°x20° ( -6dB)
200kHz
17°x 6° ( -6dB)
TD-501T-3B
4
CVS-128 50/200 kHz
1 kW
Bronze 9m
Through-hull 50kHz
5
TDM-071
CVS-128B 38 to 75 kHz
Urethane mold
15m
Through-hull Ship’s bottom/ Ship’s side
With water temperature sensor.
TDM-091D
CVS-128B 42 to 65 kHz
6
130 to210kHz
Caution: For Inner-hull installation, an Inner-hull kit is necessary.
Urethane mold
15m
Through-hull Ship’s bottom/ Ship’s side
With water temperature sensor.
20°x22° ( -6dB)
200kHz
5°x 5° ( -6dB)
38kHz
30°x20° ( -6dB) 75kHz 16°x 10° ( -6dB)
42kHz
35° ( -6dB) 65kHz
22° ( -6dB) 130kHz
14° ( -6dB) 210kHz
8° ( -6dB)
AIRMAR’s Transducer model P66 is also applicable. (Owner supply)
P66
1
xii 0093112802-06
CVS-128 50/200 kHz
600 W
Plastic 10m
Transom With water
temperature sensor and speed sensor. (The CW-840-0.3M is needed)
50kHz 69°x69° ( -6dB)
200kHz 16°x16° ( -6dB)
Page 16
CVS-128/128B Configuration of Equipment
Option List
No. Name of Item Specification Remark Weight/Length
1 Water temperature
sensor/speed sensor
ST-80 For transom mounting
Plastic made (with cable)
0.3 kg / 9 m
ST-90 For through-hull mounting
Plastic made (with cable)
ST-100 For through-hull mounting
Bronze made (with cable)
2 GPS sensor GPS-20A-10M-B
[KODEN]
3 Inner-hull kit MFB-04 Plastic made for installing the
MFB-04W Plastic made for installing the
4 Cable for transducer CW-840-0.3M Needed when using the
5 Connector for GPS
sensor
6 Cable for external
monitor
LTWBD-06PMMP-LC Needed when using the
CW-576-0.5M Junction cable for connection of
For GPS measuring (With power & signal cable)
transducer TD-500T -2B
transducer TD-501C
optional water temperature sensor / speed sensor.
GPS-20A (Type B) sensor.
external monitor
0.6 kg / 9 m
1.2 kg / 9 m
0.25 kg / 10 m
1.3 kg
1.3 kg
30 cm
0.5 m
0093112802-06 xiii
Page 17
Change the frequency CVS-128/128B
Change the frequency
CVS-128B is used with the other transducer please make sure to set the below items manually in line with the transducer installed.
Caution: The transducer may be damaged if the settings are wrong.
Caution: There are occasions too much noise is generated in a particular frequency to
be connected.
Caution: Fish symbol operation cannot be generated at the other frequencies than the
high frequency of 200 kHz and the low frequency of 50 kHz.
Setting of Output Frequency (CVS-128B)
1 Press the [MENU] key. 2 Select [Freq] [Freq select (L)]. (See [2.1 How to operate the menu]) 3 Press the [ ] key. 4 Set the output frequency at the low frequency side. (Press the [ ] key or [ ] key) 5 Set the high frequency also in the same way as for the low frequency side, in referen ce to the step
2 to 4.
6 Press the [MENU] key. Then, the edit is finished.
Caution: When single transducer is connected, set the same frequencies for low and
high.
Setting of Power Frequency (CVS-128B)
1 Press the [MENU] key. 2 Select [Freq] [Power freq adj]. (See [2.1 How to operate the menu]) 3 Press the [ ] key. 4 Set the power supply frequency. (Press the [ ] key or [ ] key)
The recommended power supply frequency for Dual frequency (50 kHz/200 kHz): 107.0 kHz
Transmit
frequency
28 kHz 115.0 kHz 70 kHz 106.5 kHz 38 kHz 105.0 kHz 75 kHz 103.5 kHz 40 kHz 123.0 kHz 120 kHz 109.0 kHz
Recommended
power supply
frequency
Transmit
frequency
Recommended
power supply
frequency
55 kHz 107.0 kHz - -
Caution: There may be much noise on the screen even for the recommended power
supply frequency depending on the transducer. In this case, set the power supply frequency to reduce the noise on the screen.
Caution: Set the power supply frequency to reduce the noise on the screen, when the
other transmission frequency than above is used.
xiv 0093112802-06
Page 18
CVS-128/128B Change the frequency
5 Press the [MENU] key. Then, the edit is finished.
Adjustment of bottom detection
When the bottom can't be detected or when the bottom is of mud pool or seawe ed, [Gain (T D)] shall be turned up. When transfer to fish schools, etc. frequently occurs, [Gain (TD)] shall be turned down.
1 Press the [MENU] key. 2 Select [Adjust] [Gain(TD)]. (See [2.1 How to operate the menu])
3 Press the [ ] key. The image displays bot tom only. It may show very strong fish targets. 4 Set a value to display the sea bottom continuously without interruption. For high frequency, turn
[GAIN (HF) knob] and for low frequency, turn [GAIN (LF) knob]
After the alteration of setting, please confirm the condition for some time. Those adjustments are recommended to be performed at the site of use.
L: 6.0 H: 6.0 R:M 12.0V
Gain (TD) L
Gain (TD) H
Gain (TD)
Bottom
5 Press the [MENU] key. Then, the edit is finished.
0093112802-06 xv
Page 19
CVS-128/128B Chapter 1 Basic Operation
Chapter 1 Basic Operation
1.1 How to use the key
CVS-128/128B Display unit
1 2
3 4
5 6
7
8
9
10
Various setting can be done directly. The menu list closes automatically after the key operation of the other keys than [menu].
No. Key Name Explanation
1 [F1] Recalls directly the item preset.
2 [EVENT]
[Cursor]
3
▲ ▼
4 [MENU] Opens or closes the menu.
5 [F2] Recalls directly the item preset.
6 [RANGE] Changes the range setting.
[GAIN(HF)
7
Knob]
[GAIN(LF)
8
Knob]
Switches to the High frequency or Low frequency of echo sounder
[DISP]
9
[BRILL
10
Power
]/
Notifies the external equipment of the present position. Presets the menu. It begins a fishing hot spot.
Selects the menu item. Changes the set value. Moves the VRM marker. Moves the marker for notifying the event.Changes the shift.
Rotate: Changes the gain value. Press: Recalls the gain select.
Rotate: Changes the gain value. Press: Recalls the gain select.
image, zoom and navigation menu.
Press: Power on. Adjusts the brilliance and brightness of panel. Long-press: Power off.
0093112802-06 1-1
Page 20
Chapter 1 Basic Operation CVS-128/128B
How to remove the hard cover
While widening the claws at right and left sides of hard cover, draw the hard cover towards you.
Claw
When removing CVS-128/128B Display unit
To prevent dust from entering, cap the connector at the rear of CVS-128/128B Display unit and the power cable with caps.
Install the supplied cap to the transducer cable as shown in the figure and cap it.
Caution: Do not pull the cable strongly. If you do so, it will be broken.
The clean of CVS-128/128B Display unit
The cleaning of the display unit goes after removing the front-frame. After removing the front-frame, use a synthetic detergent and OA cleaner and wipe the display unit lightly. Then dry sufficiently, and return the front- frame to original position.
Caution: The display unit has a special coating. Do not use a solvent such as paint thinner,
acetone, alcohol, and benzene, etc.
Caution: Strong rubbing may cause bruising and scratching.
1-2 0093112802-06
Page 21
CVS-128/128B Chapter 1 Basic Operation
k
A
1.2 Power On/Off
Power on
1 Press the [BRILL ] key to power on.
The startup menu is displayed. When started up, the internal memories (ROM, RAM) are automatically checked. When checking is normally finished, the menu below is displayed.
Caution: If an error occurs in the memory
check, the LED on the operation panel blinks. The unit may be not function normally. If you suspect trouble, contact the dealer of your purchase or our company.
2 Language Selection at Initial Startup.
When powering on first, the [Language] menu is displayed.
Language
English
日本語
Select the language with [ (The language can be selected by rotating the [GAIN (HF) Knob] or [GAIN (LF) Knob].)
3 When the installation of a transducer is
[Inner-hull], select the [Yes].
Inner-hull
No
Yes
Press [ the [Yes
]
.
]
and [
keys in sequence, and select
]
key or [] key.
]
4 Press the [MENU] key to decide the
language and the inner-hull.
5 After a few seconds, the menu sets the
screen as selected in [DISP].
Caution: In addition to English, Japanese,
there are several compatible languages.
Explanation of the display:
Rainbow pattern
Time mar
Gain
Power supply voltage
larm icon
Range
Function icon
Event icon
L H
Oscillation line
Schools of fish
Fish
Depth
Type of Gain H: High frequency gain L: Low frequency gain
Type of Range R: M: Manual Range R: A: Auto Range R: AS: Auto Shift
Power off
1 When powering off, keep pressing the
[BRILL The remaining time for the power to shut off is displayed on the menu.
] key for 3 seconds.
Alarm of Power Voltage
If detecting the malfunction of the voltage, the
icon blinks and the alarm beeps.
Caution: In case of the low voltage or the
high voltage, it shuts down. The precision of Power Voltage is ± 0.5 V.
0093112802-06 1-3
Page 22
Chapter 1 Basic Operation CVS-128/128B
1.3 LCD Brilliance Adjustment
Adjustment of LCD Brilliance
The brilliance of the display can be adjusted to facilitate visualization.
The [Lcd brill] and [Panel brill] can be switched every time when pressing the [BRILL
1 Press the [BRILL ] key for a short period of
time to display the menu ([Lcd brill]).
2 Rotate the [GAIN (HF) Knob] or [GAIN (LF)
Knob]. When “1” is selected, it is darkest. When “10” is selected, it is brightest.
Lcd brill
10
3 Press the [MENU] key to close the menu.
Brightness Adjustment of Panel Brilliance
The brightness of panel can be adjusted.
The [Lcd brill] and [Panel brill] can be switched every time when pressing the [BRILL
1 Press the [BRILL ] key for a short period of
time to display the menu ([Panel brill]).
] key.
] key.
Disp
NAV1
Normal (H)
Zoom (H) Dual Freq Zoom (L) Normal (L) NAV2
(H): High frequency
(L): Low frequency
NAV1: Navigation display1
NAV2: Navigation display2
3 Press the [MENU] key to close the menu.
Normal Image (Low frequency, High frequency)
Low frequency
Since the beam width is wide, the search range becomes wide so that the beam can search the deep depth.
High frequency
Since the beam width is narrow, it is hard to be interfered by noise and bubble in the sea so that the schools of fish can be searched in a high resolution.
2 Rotate the [GAIN (HF) Knob] or [GAIN (LF)
Knob]. When “1” is selected, it is darkest. When “10” is selected, it is brightest.
Panel brill
10
3 Press the [MENU] key to close the menu.
1.4 Switch-over of Display mode
7 kinds of displays are provided in all. Select the display suitable for your purpose.
1 Press the [DISP] key. 2 Select the display you desire to display.
(Press the [ (The set item can be selected by rotating the [GAIN (HF) Knob] or [GAIN (LF) Knob].)
] key or [ ] key.)
Low frequency
(50 kHz)
High frequency
(200 kHz)
1-4 0093112802-06
Page 23
CVS-128/128B Chapter 1 Basic Operation
Dual frequency
The High frequency image can be displayed in the right half side and the Low frequency image can be displayed in the left half side. Since the beam width differs depending on frequency, the schools of fish and sea bottom look different.
Caution: The low frequency screen can be
displayed in the right half of the sceen by replacing the screen and the high frequency screen is displayed in the left harf. (See [2.17 Explanation of Menu Item, Image Swap])
Low frequency image
High frequency image
Zoom (Low frequency, High frequency)
The normal image is displayed in the right half of the screen and the zoom image is displayed in the left half. A part of normal image can be zoomed. (1) [BTM.] (Bottom), (2) [B.D.] (Bottom Discrimination), (3) [Zoom], (4) [B.Z.] (Bottom Zoom) and (5) [B.F.Z.] (Bottom Follow Zoom) are provided for zoom.
The unit is set to (1) [BTM.] at ex-factory. To change to other zoom display, set it in the menu. (See [2.7 Selection of Zoom])
Caution: A ri ght and lef t display can be s witched. (See [2.17 Explanation of Menu Item, Image
Swap])
Zoom type Purpose
Bottom It is convenient to see the
schools of fish near the bottom.
Bottom Discrimination
Zoom
Bottom Zoom It is convenient to see the
It is convenient to see the schools of fish and a bottom quality near the bottom.
It is convenient to see the specified range in the zoom.
schools of fish near the bottom and the form of the bottom.
Zoom start position Zoomed range
It displays the position of the bottom in the fixation in the display bottom part.
It displays the position of the bottom in the fixation in the position of 1/4 under the display.
It displays a zoom start position in the fixation at the top of the display.
It displays the position of the bottom in the position which is the same as the ordinary display.
It displays the bottom and upper in the zoom.
It displays the bottom and upper in the zoom, it displays under the bottom in the ordinary. (Under the bottom, it doesn't display in the zoom).
It displays in the zoom from the zoom start position to the range you set.
It displays upper side of the bottom in the zoom except the bottom.
Bottom Follow Zoom
0093112802-06 1-5
It is convenient to see the schools of fish near the bottom and the form of the bottom.
It always displays the position of the bottom in the lower part of the display.
It displays the bottom and upper and lower sides in the zoom.
Page 24
Chapter 1 Basic Operation CVS-128/128B
(1) Bottom
The display width of zoom is displayed in orange.
Normal image
Zoomed range
(2) Bottom Discrimination
Zoomed range
30.0
Zoom image
The display width of zoom is displayed in orange.
Normal image
(3) Zoom
Zoom start position
30.0
Zoom image
The display width of zoom is displayed in orange.
Normal image
Zoomed range
30.0
Zoom image
1-6 0093112802-06
Page 25
CVS-128/128B Chapter 1 Basic Operation
Depth
Wat
C
XTE
(4) Bottom Zoom
The display width of zoom is displayed in orange.
Normal image
Zoomed range
(5) Bottom Follow Zoom
Zoomed range
30.0
Zoom image
The image below the bottom
is not zoomed.
The display width of zoom is displayed in orange.
Normal image
30.0
Zoom image
Navigation Menu (NAV1, NAV2)
The navigation menu can be displayed on the left side of the display. To display the information other than depth, sensors need to be connected. (See [1.5 Selection of NAV Display])
Caution: Requires position data from GPS sensor.
er temp
ourse
0093112802-06 1-7
Page 26
Chapter 1 Basic Operation CVS-128/128B
1.5 Selection of NAV Display
Selection of NAV Display
The information can be displayed on the NAV display (NAV 1, NAV2).
Caution:Requires position data from GPS
sensor.
Type of NAV Display
The following images can be displayed on the NAV Display (NAV1, NAV2).
Simple plotter Compass
Speed meter
Depth
Selection of NAV Menu
1 Press the [DISP] key. 2 Select the [NAV1] or the [NAV2]. (Press the
[
] key or [ ] key)
3 [NAV1] is displayed at the right side.
Disp
NAV1 Normal (H)
Zoom (H) Dual freq Zoom (L) Normal (L)
NAV2
NAV1
Display1 Display2 Display3
Display4
4 Press the [ ] key. 5 Select either one of [Display1] to [Display4]
by operating [] or [] key. At the locations where Display of NAV is shown, a numerical figure 1 , 2 , 3 or 4 is indicated. (The figure below is the case where [Display 1] is selected).
Speed meter
HDG
XTE
The time required
Wind dir.
Wind speed
Lat/Lon
Boat speed
Course
RNG BRG
Water temperature
Heading, XTE, Time required, Wind dir., Wind speed, Depth, Lat/Lon, Boat speed, Course, RNG BRG, Water temp
Depth
NAV1
Display1
Display2 Display3 Display4
Caution: When simple plotter, speed meter
or compass is displayed on the screen, [Display2] and [Display4] cannot be selected.
6 Press the [ ] key.
7 Select the [Display1]. (Press the [ ] key or
[
] key.)
Display1
Simple plotter Compass Speed meter Depth
Lat/Lon Boat speed
Course
8 Press the [MENU] key to close the menu.
1-8 0093112802-06
Page 27
CVS-128/128B Chapter 1 Basic Operation
A
A
A
A
1.6 Switch-over of Range
The range of measured depth displayed on the display can be changed.
To meet your purpose, select the range of measured depth.
Setting the range switching to auto range
By following automatically the bottom, the image of echo sounder in the suitable range of measured depth can be displayed.
This mode is convenient to display always the range from sea level to bottom.
The range value changes
Setting the range switching to Manual range
The range can be manually selected:
1 Press [] or [] key of [RANGE]. 2 Select the range you desire to set. (Press
[] or [] key of [RANGE])
Range
uto range
5.0
10.0
20.0
50.0 100 160 300 500
uto shift
3 Press the [MENU] key to close the menu.
When the [Manual] is set, the [R: M] is displayed at the upper side of menu.
1 Press [] or [] key of [RANGE]. 2 Select the [Auto Range]. (Press [] or []
key of [▲RANGE▼])
Range
uto range
5.0
10.0
20.0
50.0 100 160 300 500
uto shift
3 Press [MENU] to close the menu.
When [Auto Range] is set, the [R:A] is displayed at the upper side of menu.
Caution: At auto range, this sounder can
sound the area up to the maximum sounding registered. The maximum range is 800 m. At the initial setup, the range is up to 200 m for CVS-128 and up to 500 m for CVS-128B. (See [3.6 Setting of Adujust2 Item, Sounding])
1.7 Setting of Shift
The [Shift] (Manual Shift) and [Auto Shift] are provided.
Manual Shift (Shift):
The image range is shifted up and down. (Setting: m, fm, I.fm: 0 ~ 300, ft: 0 ~ 1000)
Caution: Only when the [shift] is
registered in [F1] key or [F2] key, it is effective. It is invalid when not registered. (See [1.10 Use of [F1] / [F2] key)
Caution: When the equipment is shipped
from the factory, the [shift] is registered in the [F2] key.
Auto Shift:
The image is automatically shifted so that the bottom is always displayed.
Setting of Manual Shift
The scope of range starting with the shift value is displayed.
0093112802-06 1-9
Page 28
Chapter 1 Basic Operation CVS-128/128B
A
A
A
A
1 Press [] of [] key of [RANGE]. 2 Select the [Auto shift] (Press [] of [] key
of [▲RANGE▼])
Range
uto range
5.0
10.0
20.0
50.0 100 160
300
500
uto shift
Range
uto range
5.0
10.0
20.0
50.0 100 160
300
500
uto shift
key or [
Range
40.0
Range
40.0
] key)
1 Press [F2] key twice. The shift function is
turned on.
Shift
OFF
ON
2 Press the [MENU] key to close the menu. 3 Press the [ ] key or [ ] key. 4 Change the set value of [Shift]. (Press the
[
key or [
]
Shift
0~300 m
] key)
10
5 Press the [MENU] key to close the menu.
Caution: This operation cannot be done
while an auto range or auto shift is working.
Release of manual Shift
3 Press the [ ] key.
4 Select a range at [Auto shift]. (Press the [ ]
5 Press the [MENU] key to close the menu.
When the [Auto shift] is set, the [R : AS] is
The shift function is released, and it returns it to
displayed at the upper side of menu.
former screen.
1 Press twice the [F2] key. The shift function is
turned off.
Shift OFF
ON
2 Press the [MENU] key to close the menu.
Setting of Auto Shift
The image is automatically shifted so that the bottom is always displayed.
1.8 Gain Adjustment
The gain can be adjusted in the auto mode [Cruising, Fishing] or manual mode.
[Cruising]
Eliminating the weak echo, it displays clearly the sea bottom of strong echo. It is suitable for cruising to the fishery ground.
[Fishing]
It displays clearly the weak echo reflected from the school of fish. It is suitable for searching the schools of fish.
1-10 0093112802-06
Page 29
CVS-128/128B Chapter 1 Basic Operation
A
Basic Operation of Gain
When [GAIN (HF) Knob] or [GAIN (LF) Knob] is
pressed twice, the screen of [Gain select] is displayed.
By rotating the [GAIN (HF) Knob] or [GAIN (LF) Knob], the gain adjustment or auto gain can be selected.
Caution: The high frequency can be set by
[GAIN (HF) Knob] and the low frequency can be set by [GAIN (LF) Knob].
Caution: When only high frequency is
displayed, no gain adjustment at low frequency is available. When only low frequency is displayed, no gain adjustment at high frequency is available.
Selecting the auto gain
When the [Cruising] or [Fishing] is set, the gain can be fine-adjusted.
1 Press [GAIN (HF) Knob] twice, and [Gain
select] is displayed. (The high frequency is explained below.)
Caution: The low frequency can be set by
[GAIN (LF) Knob].
2 Select the [Cruising] or [Fishing] by rotating
the [Knob].
Gain select
Manual
Cruising
Fishing
3 Press the [MENU] key to close the menu.
When the [Cruising] is set, the [L: AC] [H: AC] is displayed at the upper side of menu. When the [Fishing] is set, the [L: AF] [H: AF] is displayed at the upper side of menu.
Caution: The low frequency can be set by
[GAIN (LF) Knob].
2 Fine-adjust the gain by rotating the [GAIN
(HF) Knob]. The [Cursor] key menu position can be moved.
uto adjust high
0
3 Every time when [GAIN (HF) Knob] is
pressed, the [Gain select] and [Auto adjust high] are alternately displayed.
4 Press the [MENU] key to close the menu.
Selecting the manual gain
Adjustment of gain can be done manually.
1 Press [GAIN (HF) Knob] twice, and [Gain
select] is displayed. (The high frequency is explaied below.)
Caution: The low frequency can be set by
[GAIN (LF) Knob].
2 Select the [Manual] by rotating the [Knob]. 3 Press the [MENU] key to close the menu.
Manual adjustment of the gain
When only the image of High frequency is displayed, the High frequency gain can be adjusted. (Setting: 0 to 10)
When only the image of Low frequency is displayed, the Low frequency gain can be adjusted.
Caution: If you increase the gain too much,
noise will appear on the entire image, resulting in an unclear image. Adjust properly the gain so that the optimum image can be always displayed.
Adjusting the gain by auto
The auto gain adjustment can be set to [Auto adjust high] or [Auto adjust low]. (Setting:-30 ~
10)
1 Turn [GAIN (HF) Knob], and [Auto adjust
high] is displayed. (The high frequency is explained below.)
0093112802-06 1-11
1 Turn [GAIN (HF) Knob] to display [Auto
Over-gain Under-gainOptimum
adjust high]. (The high frequency is explained below.)
Page 30
Chapter 1 Basic Operation CVS-128/128B
Caution: The low frequency can be done
by [GAIN (LF) Knob].
2 Adjust the gain by rotating the [Knob]. The
[Cursor] key menu position can be moved.
Stop increasing of the gain just before noise appears on the image.
Gain(H)
6.0
3 Every time when [GAIN (HF) Knob] is
pressed, the [Gain select] and [Gain (H)] are alternately displayed.
4 Press the [MENU] to close the menu.
The latest set value of frequency (High frequency or Low frequency) adjusted is displayed at the upper left side of menu.
Example: The High frequency gain is 8.0 H: 8.0.
R: M 12.6 VH: 8.0
How to operate the menu])
3 Press the [ ] key. 4 Change the setting of [EVENT key set].
(Press the [
EVENT key set
Store pos
Store image
Fishing hot spot
] key or [ ] key)
5 Press the [MENU] to close the menu.
Presetting the waypoint
When you find the school of fish or tide, its location can be preset as a waypoint. (10 locations at maximum)
When presetting the waypoint, switch [System] [EVENT Key set] [Store pos]. (See [1.9 Use of [EVENT] key Selecting the event key function])
1 In the state that no other key is pressed,
press the [
] key or [ ] key.
1.9 Use of [EVENT] key
By pressing the [EVENT] key, three functions of [Store Position]. [Store Image] and [Fishing hot spot] are available.
The fishing hot spot is the function to instruct your boat to navigate easily to a point where you desire to go back.
[Store pos]: The latitude and longitude of a point can be stored in the destination list.
[Store image]: An image of the echo sounder can be stored in the internal memory.
[Fishing hot spot]: The WPT navigation starts, using the latitude and longitude of a point which is set as a destination by pressing the [EVENT] key. Simultaneously, the latitude and longitude of the point can be stored in the destination list.
Caution: Requires position data from GPS
sensor.
Selecting the event key function
Select the functions when pressing the [EVENT] key.
1 Press the [MENU] key. 2 Select [System] [EVENT Key set]. (Press
the [
] key or [ ] key or [ ] key) (See [2.1
2 Move the cursor (red line) with the [ ] key or
[
] key to the location to be preset as a
waypoint.
L
H
Cursor (Red line)
3 Press the [EVENT] key.
When decided, the red line is drawn at the designated location on the echo sounder menu and the latitude and longitude of designated location are registered in the waypoint list. At this moment, the list number of preset waypoint is displayed.
1-12 0093112802-06
Page 31
CVS-128/128B Chapter 1 Basic Operation
A
Store the image
When you find the schools of fish, its location can
L
H
be stored as a waypoint. (10 locations at maximum)
When storing the image, switch [NAV] [EVENT Key set] [Store pos]. (See [1.9 Use of [EVENT] key Selecting the event key function].)
1 Press the [EVENT] key.
Processing is displayed.
2 After a certain time passes, the image of
Cursor (Red line)
L
H
echo sounder presently displayed is stored and the list number of stored image is displayed.
Image data list # 1 is registered
3 After a certain time passes, the message
disappears and storing the image is finished.
Waypoint list # 1 is registered
Caution: If the
waypoint list is fully filled,
the preset destination list is not deleted, showing the message that the image is fully filled. After a certain time passes, the message disappears.
4 After a certain time passes, the message
disappears and presetting the waypoint is finished.
Caution: When pressing the [EVENT] key,
if [In out] [NMEA output data] [TLL] is set to ON, the latitude and longitude of location above-designated is output to the navigation system connected.
Caution: If the waypoint list is full, the
preset destination list is not deleted, showing the message that the list is fully filled. After a certain time passes, the message disappears.
A waypoint list is full. Registration is not completed
Caution: If the waypoint list is full, delete
an unnecessary waypoint from the waypoint list.
list of Pic is full.
Registration is not completed.
As for deletion and recall of images, see [2.15 Store/Recall/Deletion of image].
Fishing hot spot
Leads you back to your favorite fishing hot spots or other previously stored positions in memory with input from optional GPS sensor. (See [2.14 Preset/ WPT edit/ WPT delete of Waypoint])
To perform the fishing hot spot, it is necessary to select [System] [EVENT key set] [Fishing hot spot]. (See [1.9 Use of [EVENT] key Selecting the event key function].)
1 In the state that no other key is pressed,
press the [
] key or the [ ] key.
2 Move the cursor (red line) to a point you
desire to go back with the [
] key or [ ] key.
0093112802-06 1-13
Page 32
Chapter 1 Basic Operation CVS-128/128B
1.10 Use of [F1] / [F2] key
L H
Cursor (Red line)
3 Press the [EVENT] key.
When you decide, the red line is drawn on the image of the echo sounder at the point you designate and the latitude and longitude of the point you designate is stored in the destination list. At this moment, the number of the stored destination list is displayed.
4 The navigation display (NAV1) is displayed
and the WPT navigation starts.
Lat/Lon
Note: The display of NAV1 is displayed.
5 To stop the fishing hot spot, cancel
destination navigation. (See: [2.14 Preset/ WPT edit/ WPT delete of Waypoint], [Cancel the NAV].)
At ex-factory, the [Image Speed] is assigned to the [F1] key, and the [Shift] is assigned to the [F2] key. The function settable to the [F1]/[F2] key can be selected among [Image Speed], [IR], [Color Rejection], [Noise Rejection], [Shift], [Zoom Range], [Zoom Start], [A scope], [White line], [Background color], [Disp width], [Nav start], [NAV1], [NAV2], [Image swap], [Image recall] and [Sona-tone]. Set the function frequently used for your convenience.
Selecting the [F1]/[F2] key
1 Press the [F1] key or [F2] key. 2 Select the setting with [
Example [Image speed]
Image speed
Speed1
Speed2
Speed3 Speed4 Stop Speed5 (1/1) Speed6 Speed7 Speed8 Speed9
Caution: When the fish symbol function is
made effective, the image speed becomes two kinds ([Speed5 (1/1)] or [Stop]).
key or [] key.
]
3 Press the [MENU] key to close the menu.
Preset of [F1] / [F2] key
1 Press the [MENU] key. 2 Select [System] [F1 key set] or [F2 key
set]. (Press the [ key.) (See [2.1 How to operate the menu])
] key or [
key or []
]
3 Press the [ ] key. 4 Select the function. (Press the [
key)
key or []
]
1-14 0093112802-06
Page 33
CVS-128/128B Chapter 1 Basic Operation
A
r
r
A
r
F1 key set Image Speed
IR Color Rejection Noise Rejection
Shift Zoom Range Zoom Start
L
H
Marker Depth
20.0
Movable marke
scope
White line
Background Colo
5 Press the [MENU] key to close the menu.
The icons of functions preset are displayed at the upper right side on the menu.
Image speed
IR
Color rejection
Noise rejection
Shift
Zoom Range
Zoom Start
← ←
White Line
Background colo
scope
Image recall
Image swap
NAV1
NAV2
Disp width
Sona-tone
Other than the above operation method. When keep pressing the [F1] key or [F2] key for few second, the key set menu is displayed.
1.11 Operation of VRM
The VRM (movable marker) shown by the green line can be moved up and down.
It is convenient to measure the depth by aligning with the target such as school of fish.
When displaying dual images, if the [ or [
] key is pressed, the movable marker
] key
moves to the neighboring image.
Caution: When several seconds pass
after finishing the VRM operation, the numerical of marker depth becomes normal display.
Caution: If VRM is moved to the top of
the display, the VRM can be disappeared.
Caution: VRM can be operated by turning
[GAIN (LF) Knob] at the high frequency screen.
Caution: VRM can be operated by turning
[GAIN (HF) Knob] at the low frequency screen.
1.12 Display of fish information
When transducer TD-501C is connected, specific response can be displayed as [Fish symbol].
1 Press the [ ] key or [ ] key. The movable
marker (straight line) is displayed.
For detection of fish information, 2 frequencies, 200 kHz and 50 kHz are used.
2 Press the [ ] key or [ ] key. The movable
marker moves up and down. The movable marker and the numerical of marker depth are simultaneously highlighted.
Only in case echo comes up in both frequencies, the detection can be made.
By [Symbol info], the magnitude and the value of depth of the response can be displayed.
Caution: Fish information is to display the
specific responses in an easy way to watch. Displays of [Fish symbol] do not always mean that there is fish there.
0093112802-06 1-15
Page 34
Chapter 1 Basic Operation CVS-128/128B
Caution: The area where [Fish symbol]
can be displayed is from 3 m to 100 m. (ft: 10 to 330, fm: 2 to 54, I.fm:2 to 60)
Caution: [Fish symbol] is not displayed in
the range that is deeper than 120m. (ft: 350, fm:60, I.fm:70)
Caution: When the fish symbol function is
made effective, the image speed becomes 2 kinds ([Speed5 (1/1)] or [Stop]).
Caution: Adjustment is necessary when
equipped with Inner-hull. (See [2.17 Explanation of Menu Item, Inner-hull].)
Display the fish symbol/Stop the display of fish symbol
1 Press the [MENU] key. 2 Select [Display1] [Fish symbol]. (Press
the [
] key or [ ] key or [ ] key.) (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Select the symbol to be displayed on the
screen. (Press the [
Fish symbol
Symbol 1
] key or [ ] key)
5 Press the [MENU] key to close the menu.
When this function is effective, the icon is displayed at the top of the screen.
Caution: When [Fish symbol] on the
screen does not always mean that the response shows fish.
Selecting the symbol info
[Symbol info] is effective only when [Fish symbol]
is displayed.
1 Press the [MENU] key. 2 Select [Display1] [Symbol info]. (Press
the [
] key or [ ] key or [ ] key.) (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Select the information associated with [Fish
symbol] (Press the [
] key or [ ] key.)
Caution: The display of [Size] is
expressed in cm.
Symbol info
OFF Depth
Size
B ot t om <=>F is h
5 Press the [MENU] key to close the menu.
Caution: The magnitude by [Symbol info]
would not be always the response from fish. And it may be incorrect due to various environmental conditions. Please take these as reference.
Caution: The value of depth by [Symbol
info] would not be always the response from fish. That shows the point that there was specific response.
Fish symbol detection adjustment
Detection of fish marks can be adjusted.
Select [Correct] [Detect adjust f].
Caution: If the larger the set values
become, the more fish marks can be displayed with more false detections.
Caution: For Through-hull installation,
adjust between 1 and 4. For Inner-hull installations, adjust between 3 and 6.
Size adjustment
The indicated size of fish marks can be adjusted.
Please correct the size when the indicated value is different from the fish that actually caught.
Select [Correct] [Size adjust].
The indicated size will change by approximately 10 to 20 percent of the value, per one setting value.
1-16 0093112802-06
Page 35
CVS-128/128B Chapter 1 Basic Operation
Caution: When the value of [Detect
adjust f] is set at 5 or 6, the size of fish can not be specified and there may be cases where no numerical figures are displayed or only "----" is displayed. When there is no display of numerical figures, it is judged that fish are too small. When "---" is displayed, it is judged that fish is too big.
Big fish / Big fish color
The fish bigger than the set value [cm] is specified as big fish.
Select keys of [Display2] [Big fish].
Colors for values of big fish can be assigned.
Select keys of [Display2] [Big fish color].
 [Color table 2]
The values displayed by this function may be incorrect depending on various environmental conditions. In use of these values, please understand the following factors of error, and use them as reference:
[Factors of error]
1 When there are overlapping responses,
2 The strength of reflection may depend on
3 The strength of reflection may depend on
4 Fish banks, fishing net, fishing equipment,
5 When the transducer unit is mounted in
Points to note in use of fish symbol
all of them may be displayed to show the magnitude of a point.
the output of transducer unit and may result in a factor of error.
the kind of fish and may result in a factor of error. As for the fish such as the squid which don't have an air bladder, the error is big.
air bubbles and floating objects, etc. may be detected and displayed.
inner-hull, there may be cases where response cannot be detected depending on attenuation, and large error may be generated.
6 The strength of reflection may depend on
the difference of ship handling such as stoppage and cruising, and may result in a factor of error.
7 Each transducer unit may have difference
in transmission/receiving performance to cause error.
8 When there is dirt in the sea and the
plankton layers have been generated, it becomes the factor of the error margin.
0093112802-06 1-17
Page 36
CVS-128/128B Chapter 2 How to use the menu
A
A
A
A
A
A
A
A
A
A
Chapter 2 How to use the menu
2.1 How to operate the menu
Display the menu/Stop the display of menu
1 Press the [MENU] key.
The menu and explanation of operation are displayed.
Name of menu selected
Menu column
djust
D.range Display1
Display2
NAV Image System
Freq*
* For CVS-128B
larm1 larm2
Next
Setting item column
Image speed IR
Color rejection
Noise rejection
TX power
Gain (TD) Pulse width*
Band width*
D.Range* Return
Guide
It is displayed when the [Operation Guide] is set to ON.
(See [2.17 Explanation of Menu Item Display the operation guide / Stop the display of operation guide].)
2 Press the [MENU] key.
The menu and explanation of operation close.
Menu Operation
Cursor
Speed 5 Strong 0%
0 Medium TVG
uto
Middle Middle
24dB
Setting value
djust D.range Display1 Display2
larm1
larm2 NAV Image System Freq*
Next
* For CVS-128B
Shift step Zoom type Zoom range Zoom start
Disp width Range preset Return
1m
Bottom
10.0m 0m Center
2 Press the [ ] key.
The cursor appears in the set item column. (The cursor appears by pressing the [GAIN (HF) Knob] or [GAIN (LF) Knob].)
3 Select the set item you desire to change
with the [ (The set item can be selected by rotating the [GAIN (HF) Knob] or [GAIN (LF) Knob])
djust D.range Display1 Display2
larm1
larm2 NAV Image System
Freq* Next
* For CVS-128B
4 Press the [
The set menu corresponding to the selected item is displayed. (It can be displayed by rotating the [GAIN (HF) Knob] or [GAIN (LF) Knob].)
key or [] key.
]
Shift step Zoom type Zoom range Zoom start Disp width Range preset Return
key.
]
1m Bottom
10.0m 0m Center
1 When the menu is displayed, press the [
key or [ Depending on the selected menu name, the content in the set item column at the right side changes. (The menu name can
key to select the menu name.
]
]
Zoom range
10.0
m
be selected by rotating the [GAIN (HF) Knob] or [GAIN (LF) Knob].)
5 Change the set content with the [
key.
[
]
key or
]
(It can be changed by rotating the [Knob])
6 Press the [
key.
]
The cursor returns to the set item column.
0093112802-06 2-1
Page 37
Chapter 2 How to use the menu CVS-128/128B
(It can be displayed by rotating the [GAIN (HF) Knob] or [GAIN (LF) Knob])
7 To select the other menu item, press the
[
] key.
The cursor returns to the menu column.
8 Press the [MENU] key to close the menu.
2.2 Changing of Image Speed
The image speed of echo sounder can be changed. Even if the schools of fish and bottom are same, the image changes depending on the image speed.
The image speed becomes slow in the order of [Speed1] [Speed2]····· [Speed9]. When [stop] is selected, the image stops.
Caution: When the fish symbol function
is made effective, the image speed becomes 2 kinds ([Speed5 (1/1)] or [Stop]).
1 Press the [MENU] key.
2.3 Rejection of Interference
Interference Rejection
The interference noise from the echo sounder of other boats can be reduced.
If a neighboring boat uses the echo sounder having the same frequency and pulse transmission rate as those your boat has, the interference noise may be displayed. If you set the interference rejection, the interference noise can be reduced. In the order of weak strong, the noise rejection capability becomes high.
The difference of images based on the different settings of [Intererence reduction]
Image of school of fish
2 Select the [Adjust] [Image Speed]. (See
[2.1 How to operate the menu].)
3 Press the [ ] key. 4 Change the setting of [Image Speed].
(Press the [
Image speed
Speed 1 Speed 2
Speed 3 Speed 4 Stop
Speed 5 (1/1)
Speed 6 Speed 7 Speed 8
Speed 9
] key or [ ] key.)
5 Press the [MENU] key to close the menu.
Interference image
OFF
Weak
Strong
1 Press the [MENU] key. 2 Select the [Adjust] [Interference Rejection].
(See [2.1 How to operate the menu].)
3 Press the [ ] key. 4 Change the setting of [Inference Rejection].
(Press the [
IR
OFF
Weak
Strong
] key or [ ] key.)
2-2 0093112802-06
5 Press the [MENU] key to close the menu.
Page 38
CVS-128/128B Chapter 2 How to use the menu
2.4 Color Rejection of Weak Echo
Color Rejection
The color of weak echo can be rejected.
Rejecting noise on the entire image and weak echo around the school of fish makes it easier to see the school of fish. It is the convenient function when displaying the echo stronger than the specific signal. (Setting: 0 to 50 %)
1 Press the [MENU] key. 2 Select the [Adjust] [Color Rejection].
(See [2.1 How to operate the menu])
3 Press the [ ] key. 4 Change the setting of [Color Rejection].
(Press the [
Color Rejection
5 Press the [MENU] key to close the menu.
] key or [ ] key.)
0
%
5 Press the [MENU] key to close the menu.
2.6 Setting of Shift step
The shifting range is set by pressing the [ key or [ 10m, 1/8, 1/4)
] key one time. (Setting range: 1m,
1 Press the [MENU] key. 2 Select the [D.range] [Shift step]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Change the setting of [Shift step]. (Press
the [
] key or [ ] key.)
Shift step
1m
10m 1/8 1/4
5 Press the [MENU] key to close the menu.
]
2.5 Rejection of Noise
Noise Rejection
The influence of noise can be reduced.
Due to echo reflected from plankton and trash, the speck-like noise may appear on the entire image. Setting the [Noise rejection] reduces the speck-like noise and makes it easier to see the image of school of fish. (Setting: 0 to 10)
The greater the set value becomes, the stronger the effect of noise rejection becomes.
1 Press the [MENU] key. 2 Select [Adjust] [Noise rejection]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Change the setting of [Noise rejection].
(Press the [
Noise Rejection
] key or [ ] key)
5
Caution: When the shift is set to 1/4
with 100m range, it shifts by 25m.
2.7 Selection of Zoom
Set the zoom display with the display mode ([zoom (H)] or [zoom (L)].
The [Bottom], [Bottom Discrimination], [Zoom], [[Bottom Zoom] and [Bottom Follow Zoom] are provided. (See [1.4 Switch-over of Menu])
1 Press the [MENU] key. 2 Select [D.range] [Zoom type]. (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Select the zoom type. (Press the [ ] key or
[
] key)
0093112802-06 2-3
Page 39
Chapter 2 How to use the menu CVS-128/128B
Zoom type BTM.
B.D. Zoom B.Z. B.F.Z.
5 Press the [MENU] key to close the menu.
For each zoom display, refer to [1.4 Switch-over of Display mode].
2.8 Setting of Zoom Range
Set the zoom range in each mode of [BTM], [Bottom Discrimination], [Zoom], [Bottom Zoom] and [Bottom Follow Zoom]
The zoom range of each mode is identical.
(See [1.4 Switch-over of Display mode]) (Setting: m: 2.5 to 200, fm, I.fm: 2.5 to 150, ft:10.0 to 650)
2.9 Setting of Zoom Start
Select the zoom start in the [Zoom]. (See [1.4 Switch - over of Display mode])
(Setting: m: 0 to 800, fm, I.fm: 0 to 500, ft: 0 to
2600)
Zoom Start
1 Press the [MENU] key 2 Select [D. range] [Zoom start] (See [2.1
How to operate the menu])
3 Press the [ ] key.
Zoom Range
1 Press the [MENU] key. 2 Select [D. range] [Zoom range]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Change the set value of [Zoom range].
(Press the [
Zoom Range
] key or [ ] key)
10.0
m
5 Press the [MENU] key to close the menu.
4 Change the set value of [Zoom start].
(Press the [
Zoom start
0~800 m
0-800
] key or [ ] key)
10
5 Press the [MENU] to close the menu.
2.10 Preset of Range
The range switched with the [ can be set.
Preset the set value suitable for your purpose. (Setting range: m: 2.5 to 1200, fm, I.fm: 2.5 to 700, ft: 10 to 3600)
1 Press the [MENU] key. 2 Select [D.range] [Range preset]
[Range 1 to 8]. (See [2.1 How to operate the menu])
RANGE ] key
3 Press the [ ] key.
2-4 0093112802-06
Page 40
CVS-128/128B Chapter 2 How to use the menu
A
A
A
A
A
5
4 Select [Range 1 to 8]. (Press the [ ] key or
[
] key)
djust
D.range
Disp1 Disp2
larm1 larm2
NAV
Image
System Freq* Next
* For CVS-128B
Prev Range 1
Range 2
Range 3
Range 4
Range 5 Range 6
Range 7
Range 8
Return
5.0 m
10.0 m
20.0 m
50.0 m
100 m 160 m 300 m 500 m
Caution: Select [Forward], and press [
key to return to the previous menu.
5 Press the [ ] key. 6 Select the set value of [Range 1 to 8].
(Press the [
Range1
key or [] key)
]
20.0
m
7 Press the [MENU] key to close the menu.
Easy registration method of the range
1 Press [] or [] key of [RANGE]. 2 Change the range you desire to set. (Press
[] or [] key of [RANGE])
Range
uto range
5.0
10.0
20.0
50.0 100 160 300 500
uto shift
Range1
.
0
m
5 When the [ ] key is pressed, it returns to
the [range]. Other detecting range can be continuously changed.
6 Press the [MENU] key to close the menu.
2.11 Setting of Background Color
Responding to the ambient brightness, the
]
background color of display can be changed.
1 Press the [MENU] key. 2 Select [Display1] [Background color].
(See [2.1 How to operate the menu])
3 Press the [ ] key. 4 Change the setting of [Background color].
(Press the [
Background color
Pale blue
Marine blue
Blue Dark blue Black Darkkhaki Mediumseagreen Light grey White
Night mode
] key or [ ] key)
5 Press the [MENU] to close the menu.
2.12 Setting of White Line
As the surface of bottom is marked with the white line of constant width, the school of fish at the bottom can be easily identified.
3 Press the [ ] key.
4 Select the set value of Range. (Press the
[
key or [] key)
]
0093112802-06 2-5
Page 41
Chapter 2 How to use the menu CVS-128/128B
W
range. It is convenient for you to judge whether the echo of school of fish is present or not. (Setting: m: 1 to 800, fm, I.fm: 1 to 700, ft: 1 to
2800)
Caution: In the [Level], select the
strength of echo reflected from the
hite line
1 Press the [MENU] key 2 Select [Display1] [White line]. (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Change the setting of [White line].
“1” is narrowest. “5” is widest. In the auto mode, responding to the strength of echo reflected from the bottom, the width of white line changes. (Press the [
] key or [ ] key)
White line
OFF
1
2 3 4 5 Auto
schools of fish in the [Fish alarm].
[Water temp alarm] issues when the water temp is within or out of the set range. It is convenient to keep the specific water temp region. (Setting:
- 5 to 45 ºC, 23 to 113 ºF)
[Speed alarm] issues when the boat speed is faster or slower than the set range. It is convenient when the speed limit is obliged. (Setting: 0 to 80 kn, 0 to 148 km/h)
[Arrival alarm] can be used in the state that the destination is set. The alarm is issued when your boat arrives within a certain range of destination. A certain range is set in the [NAV alarm range]. (See [1.9 Use of [EVENT] key.)
[XTE alarm] can be used in the state that the destination is set. The alarm is issued when your boat is off a certain distance from the course on the line drawn straightly from destination to the location when setting the destination. A certain distance is set in the [NAV alarm range].
Caution: In the [NAV alarm range], select
the alarm range of [Arrival alarm] and [XTE alarm]. (Setting: 5 to 999 m)
5 Press the [MENU] key to close the menu.
2.13 Setting of Alarm
Caution: The setting range of [Arrival
alarm] and [XTE alarm] can not be separately set.
6 alarms of bottom alarm, fish alarm, water temp alarm, speed alarm, arrival alarm and XTE alarm can be set.
They are notified by alarm sound and alarm display.
[Bottom alarm] issues the alarm when the position recognized as the bottom is shallower than the upper limit or deeper than the lower limit. It is convenient when keeping the specific depth. (Setting: m: 0 to 800, fm, I.fm: 0 to 700, ft: 0 to 2800)
[Fish alarm] issues the alarm when an echo recognized as school of fish exists in the set
2-6 0093112802-06
Stopping the alarm sound
To stop the alarm sound and the alarm display, press [MENU] key.
Page 42
CVS-128/128B Chapter 2 How to use the menu
A
A
A
A
A
A
A
A
Setting the alarm
djust
D.range
Disp1 Disp2
larm1 larm2
NAV Image System
Freq*
Next
djust
D.range Disp1
Disp2
larm1 larm2
NAV Image System
Freq*
Next
* For CVS-128B
Bottom alarm
Upper depth Lower depth
Fish alarm
Position Range Level
Return
Water temp alarm
Upper temp alarm Lower temp alarm
Speed alarm
Speed limit
rrival alarm XTE alarm NAV alarm range
Return
1 Press the [MENU] key.
OFF
5m 50m
OFF
5m 50m Medium
OFF
20.0ºC
15.0ºC
OFF
0kn
OFF OFF 10m
Confirm the alarm state
The set state of [Bottom alarm] and [Fish alarm] can be confirmed on the bar at the right corner of display. However, when the display is out of the range, they are not displayed.
When [Water temp alarm], [Speed alarm], [Arrival alarm] or [EXT alarm] is ON, the corresponding icon is displayed at the upper side of the screen.
[ XTE alarm]
[
rrival alarm
Speed alarm
[
Water temp alarm
[
]
] ]
Bottom alarm
[
Fish alarm
[
]
]
2 Select your desired alarm from [Alarm 1] or
[Alarm 2]. (See [2.1 How to operate the menu].)
3 Press the [ ] key. 4 Select the [ON] of alarm you desire. (Press
] key or [ ] key)
the [
5 If the setting of [Alarm range] is provided in
the alarm desired, select the alarm range. (See [2.1 How to operate the menu])
6 Change the set value of alarm range.
(Press the [
] key or [ ] key)
7 Press the [MENU] key to close the menu.
Release the alarm
1 Press the [MENU] key. 2 Select the alarm to be released from
[Alarm 1] or [Alarm 2]. (See [2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [OFF] of alarm to be released.
(Press the [
] key or [ ] key)
5 Press the [MENU] key to close the menu.
0093112802-06 2-7
Page 43
Chapter 2 How to use the menu CVS-128/128B
2.14 Preset/WPT edit/WPT delete of Waypoint
NAV Start
The NAV can be started by selecting the destination from the destination list.
To perform the NAV start, the destination must be preset. (See [1.9 Use of [EVENT] key]
Caution: Requires position data from
GPS sensor.
1 Press the [MENU] key. 2 Select [NAV] [NAV start]. (See [2.1 How
to operate the menu])
3 Press the [ ] key. 4 Select the [Destination list] preset. (Press
the [
] key or [ ] key)
)
Cancel the NAV
The NAV started can be cancelled halfway.
1 Press the[MENU] key 2 Select [NAV] [NAV cancel]. (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Press the [Yes]. (Press the [ ] key or [ ]
key)
NAV cancel
Yes
No
5 Press the [MENU] key. Then, the NAV is
released.
6 To return the display to the original one,
the display mode shall be switched over. (See: [1.4 Switch-over of Display mode])
Edit the destination
Caution: The list No. selected is reversed
in yellow.
5 Press the [ ] key. 6 Select the [Yes] in the confirmation menu.
(Press the [
NAV starts
Yes
No
] key or [ ] key)
7 Press the [MENU] key.
Then, the NAV starts.
By entering the latitude and longitude, the destination can be preset.
The list preset in the past can be edit.
1 Press the [MENU] key. 2 Select [NAV] [WPT edit]. (See [2.1 How
to operate the menu])
3 Press the [ ] key. 4 Select the list No. to be edited from the
[WPT edit] list. (Press the [ key)
] key or [ ]
5 Press the [
key.
]
6 Select the character with the [ ] key or [ ]
2-8 0093112802-06
Page 44
CVS-128/128B Chapter 2 How to use the menu
key. (Character: A ~ Z, blank, 0 ~ 9, +, -./ Lat/Lon: 0~9,N,S,E,W)
7 Move the position of characters to be
reversed with the [
] key or [ ] key.
Delete the waypoint
The destination list preset in the past can be deleted.
The deletion takes some time.
1 Press the [MENU] key. 2 Select [NAV] [WPT delete]. (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Select the list number of destination to be
deleted from the [WPT delete]. (Press the [
] key or [ ] key)
Caution: If the values of latitude and
longitude are not entered, they are registered as 0.
8 To end editing, press [GAIN (HF) Knob] or
[GAIN (LF) Knob].
9 After finishing the edit work, press the
[MENU] key.
10 Select the [registered] in the confirmation
menu.
Edit end Registered
Not registered
11 Press the [MENU] key. Then, the edit is
finished.
5 Press the [ ] key. 6 Select the [Yes] in the confirmation menu.
(Press the [
WPT delete
Yes
No
] key or [ ] key)
7 Press the [MENU] key. Then, the
destination is deleted and the menu closes.
Recall the stored image and preset it as a destination
Recall the stored image in the past and it can be preset as a destination. [EVENT] key]
)
(See [1.9 Use of
1 Press the [MENU] key. 2 Select [Image] [Image recall]. (See [2.1
How to operate the menu].)
3 Press the [ ] key. 4 Select the image No. from the [Image
0093112802-06 2-9
Page 45
Chapter 2 How to use the menu CVS-128/128B
recall] list. (Press the [
Image recall
No.
Comment
1
P IC 0 0 0 0 1
2
P IC 0 0 0 02 P IC 0 0 0 03
3 4
P IC 0 0 0 04 P IC 0 0 0 05
5
P IC 0 0 0 06
6
P IC 0 0 0 07
7
P IC 0 0 0 08
8
P IC 0 0 0 09
9
010
P IC 0 0
10
Caution: Chosen list NO. becomes
yellow.
] key or [ ] key)
5 Press the [ ]key. 6 Move the cursor to the location preset as a
destination with the[ select it.
key or [
]
] key and
2.15 Store / Recall / Deletion of Image
Store the image
The present image of echo sounder can be stored.
To memorize, it takes some time.
To memorize the image, the [EVENT] key must be switched to the [Store image].
1 Press the [MENU] key. 2 Select [System] [EVENT key set]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [Store image]. (Press the [ ]
key or [
EVENT key set
Store pos
Store image
Fishing hot spot
] key)
L
Caution: You can switch to other stored
image with the [
H
Cursor(red line
] or [ ] key.
7 When starting the NAV, press the [EVENT]
key. When not starting the NAV, press the [MENU] key.
5 Press the [MENU] key to close the menu. 6 When the echo sounder image to be
stored appears, press the [EVENT] key.
7 When the stored image is fully filled, it
shows that the [Store image] is fully filled. After deleting the unnecessary image, try it again.
Recall the stored image
The stored image in the past can be recalled.
During recalling, the image cannot be stored.
1 Press the [MENU] key. 2 Select [Image] [Image recall]. (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Select the number of image to be recalled
from the [Image recall] list. (Press the [ key or [
] key)
]
2-10 0093112802-06
Page 46
CVS-128/128B Chapter 2 How to use the menu
Image recall
No.
Comment
P
1
I C0 0 0 0 1
2
P I C0 0 0 02
I C0 0 0 03
P
3
P
4
I C0 0 0 04
P
I C0 0 0 05
5
P
I C0 0 0 06
6
I C0 0 0 07
P
7
P
I C0 0 0 08
8
P
I C0 0 0 09
9
010
P
I C0 0
10
Caution: Chosen list NO. becomes
yellow.
5 Press the [ ] key.
Caution: When other stored image
exists beside the recall image, switch to other image with the [ and [
key.
]
]
6 Press the [MENU] key to return to the
normal menu.
Delete the stored image
The stored image in the past can be deleted.
To delete, it takes some time.
1 Press the [MENU] key. 2 Select [Image] [Image delete]. (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Select the number of image to be deleted
from the [Image delete] list. (Press the [ key or [
Image delete
No. Comment 1 2 3 4 5 6 7 8 9 10
] key)
PI
C0 0 0 0 1
PI C0 0 0 02
C0 0 0 03
PI PI
C0 0 0 04 C0 0 0 05
PI
PI
C0 0 0 06
PI
C0 0 0 07
PI
C0 0 0 08
PI
C0 0 0 09
010
PI
C0 0
5 Press the [ ] key.
6 Select the [Yes] in the confirmation menu.
Image delete
Yes
No
7 Press the [MENU] key.
Then, the preset image is deleted.
Add the comment to the stored image
It is convenient to judge the stored image.
1 Press the [MENU] key. 2 Select [Image] [Image comment]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the number of image to which the
comment is added from the [Image comment]. (Press the [
Image comment
No. Comment
PIC00001
1
PIC00002
2
PIC00003
3
PIC00004
4
PIC00005
5
PIC00006
6
PIC00007
7
PIC00008
8
PIC00009
9
PIC00010
]
10
] key or [ ] key)
5 Press the [ ] key. 6 Select the character with the [
key. (Character: A ~ Z, blank, 0 ~ 9, +, -./)
Image comment
No. Comment 1
P IC00001
2
P IC00002
P IC00003
3
key or []
]
7 Select the comment position with the [ ]
key or [
] key.
0093112802-06 2-11
Page 47
Chapter 2 How to use the menu CVS-128/128B
Image comment
Comment
No. 1
P I C0 0 0 0 1
2
P I C0 0 0 02
I C0 0 0 03
P
3
8 To stop editing, press [GAIN (HF) Knob] or
[GAIN (LF) Knob].
9 After finishing the edit, press the [MENU]
key.
10 Select the [register] in the confirmation
menu.
Edit end Registered
Not registered
11 Press the [MENU] key. Then, the edit is
finished.
2.16 Explanation of Sonar
Switch-over of Sona-ToneTM
The Sona-ToneTM can be output to the built-in speaker by selection.
Connection of External Speaker
Connect the external speaker with amplifier (option) so that you can hear the sonar easily.
TM
Caution: The Sona-Tone
output. Adjust the speaker volume with the volume provided on the speaker.
Caution: The external speaker is an
option.
is always
2.17 Explanation of Menu Item
The various items in the menu are explained.
Inner-hull
The reduction in sensitivity due to signal attenuation in inner-hull use can be corrected. (Setting: - 50 ~ 50: through-hull: 0)
1 Press the [MENU] key. 2 Select the [Adjust] [Gain (TD)]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. The image displays
bottom only. It may show very strong fish targets.
The schools of fish and condition of bottom on the display of echo sounder can be confirmed by hearing the sonar.
1 Press the [MENU] key. 2 Select the [System] [Sona-tone]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [ON] or [OFF] of [Sona-tone].
(Press the [
Sonar tone
Sona-tone
OFF
ON
] key or [ ] key)
5 Press the [MENU] key to close the menu.
4 Set a value to display the sea bottom
continuously without interruption. For high frequency, turn [GAIN (HF) knob] and for low frequency, turn [GAIN (LF) knob].
Gain (TD) L
Gain (TD)
Gain (TD) H
Bottom
5 Press the [MENU] key to close the menu.
2-12 0093112802-06
Page 48
CVS-128/128B Chapter 2 How to use the menu
Caution: Gain (TD) setting value widely
varies upon installation conditions such as material of hull and installation method. Low frequency (50 kHz) may not be used due to large signal attenuation in some cases.
TVG
The TVG adjusts the difference of strength between echoes reflected from the shallower depth and echoes reflected from deeper depth so that the reflection can be uniformed.
The deeper the depth is, the weaker the reflected signal of echo sounder becomes due to attenuation. Thus, comparing the signal reflected from the fish of the same size, the signal reflected from the fish in the shallower depth is stronger than that in the deeper depth. The TVG adjusts the echo signal reflected from the shallower depth to be equal to that reflected from deeper depth by decreasing the receiver gain so that the effect that the strength of echo signal reflected from the shallower depth looks the same as that reflected from the deeper depth provided. The level of adjustment due to the depth increases in the order of weak medium strong. When set to "Strong", the TVG provides strongest effect that reduces various noises around oscillation line.
1 Press the [MENU] key.
2 Select the [Adjust] [TVG]. (See [2.1 How
to operate the menu])
Change the TX power
The strength of transmission output (power) can be changed.
When the noise of interference with the neighboring echo sounder occurs, if the powers of transmission outputs at both sides are weakened, the interference noise can be suppressed.
1 Press the [MENU] key. 2 Select the [Adjust] [TX power]. (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Select the [TX power]. (Press the [ ] key
or [
] key.)
TX power
20
1
30 40 50
60 70 80 90 100
Auto
5 Press the [MENU] key to close the menu.
Caution: In [Auto] setting, it controls
transmission power automatically.
3 Press the [ ] key. 4 Select the [weak], [medium], [strong].
(Press the [
TVG
Weak
Medium
Strong
] key or [ ] key)
5 Press the [MENU] key to close the menu.
Caution: When the setting of [Gain
select] is either one of [Cruising] or [Fishing], it cannot be selected.
0093112802-06 2-13
Change the Pulse width
Resolution and the detection distance change by changing the transmission pulse width. As for [Super short], the detection distance shortens though resolution goes up. As for [Long], the detection distance becomes long though resolution falls.
1 Press the [MENU] key. 2 Select the [Adjust] [Pulse width]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Change the setting of [Pulse width]. (Press
the [
] key or [ ] key.)
5 Press the [MENU] key to close the menu.
Page 49
Chapter 2 How to use the menu CVS-128/128B
Caution: When the fish symbol
function is made effective, this function becomes invalid.
For CVS-128B
Change the Bandwidth
The bandwidth is automatically set according to the transmission pulse width. Please make it to [Narrow] when you decrease the noise. Please make it to [Super narrow] when you decrease more.
1 Press the [MENU] key. 2 Select the [Adjust] [Bandwidth]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Change the setting of [Bandwidth]. (Press
the [
] key or [ ] key.)
5 Press the [MENU] key to close the menu.
Caution: When the fish symbol function
is made effective, this function becomes invalid.
For CVS-128B
D.Range
D.Range is to expand and narrow down the signal range from blue to red in images.
When the value is small, the expression range of strong and weak signal change is narrow, weaker signal will become undistinguished. When the value is larger, the expression range is wider and the weaker signals become distinct. (Setting: 12 to 30dB)
1 Press the [MENU] key. 2 Select the [Adjust] [D.Range]. (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Change the setting of [D.Range]. (Press
] key or [ ] key.)
the [
5 Press the [MENU] key to close the menu.
For CVS-128B
Display Width
When the image is zoomed or dual frequency displayed, the display width can be changed.
1 Press the [MENU] key. 2 Select the [D.range] [Disp. width]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the width of image. (Press the [ ]
key or [
] key)
5 Press the [MENU] key to close the menu.
Display the A scope/Stop the display of A scope
The echo strength of latest echo can be displayed at the right side of echo sounder display.
The strength of echo sounder image is expressed by the horizontal width. This expression is called [A scope].
The width for strong echo is wide and the width for weak echo is narrow. This makes it easier for you to see the echo.
1 Press the [MENU] key. 2 Select the [Display1] [A scope]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 To display the A scope, select the [ON].
To stop the display of A scope, select the [OFF]. (Press the [
] key or [ ] key)
5 Press the [MENU] key to close the menu.
Change the display color of echo sounder image
The [Monochrome], [8 color], [16 color] and [64 color] can be selected.
1 Press the [MENU] key. 2 Select the [Display1] [Color tone]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [Color tone]. (Press the [ ] key
or [
] key)
5 Press the [MENU] key to close the menu.
2-14 0093112802-06
Page 50
CVS-128/128B Chapter 2 How to use the menu
Change the depth value
The display size of depth value can be changed.
1 Press the [MENU] key. 2 Select the [Display1] [Depth value].
(See [2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the size of display. (Press the [ ]
key or [
] key)
5 Press the [MENU] key to close the menu.
Display the depth unit / Stop the display of depth unit
The depth unit can be displayed.
1 Press the [MENU] key. 2 Select the [Display1] [Unit display]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 To display the depth unit, select the [ON].
To stop the display of depth unit, select the [OFF]. (Press the [
] key or [ ] key)
5 Press the [MENU] key to close the menu.
Display the water temp graph/Stop the display of water temp graph
The latest water temp value and the graph of past water temp data can be displayed.
1 Press the [MENU] key. 2 Select the [Display1] [Water temp
graph]. (See [2.1 How to operate the menu])
3 Press the [ ] key. 4 To display the water temp graph, select the
[ON]. To stop the display of water temp graph, select the [OFF]. (Press the [ key)
] key or [ ]
5 Press the [MENU] key to close the menu.
Setting of the background color of NAV display
The color of background of navigation display
(NAV1, NAV2) can be changed.
1 Press the [MENU] key. 2 Select the [NAV] [Background color].
(See [2.1 How to operate the menu].)
3 Press the [ ] key. 4 Select the [Background color]. (Press the
[
] key or [ ] key)
5 Press the [MENU] key to close the menu.
Setting of the echo sounder display at NAV display
The sounder display can be selected at NAV (NAV 1, NAV 2) to be displayed.
1 Press the [MENU] key. 2 Select the [NAV] [NAV1 (2)]. (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Select the echo sounder display at [NAV 1]
or [NAV 2] to be displayed. (Press the [ key or [
key)
]
]
5 Press the [MENU] key to close the menu.
Image Swap
The images of echo sounder at the right and left sides can be swapped.
1 Press the [MENU] key. 2 Select the [Image] [Image swap]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the swap state [A|B],[B|A]. (Press
the [
] key or [ ] key)
5 Press the [MENU] key to close the menu.
Display the Operation guide/Stop the display of Operation guide
When displaying the menu, it sets whether or not the operation guide is displayed at the lower part on the display.
0093112802-06 2-15
Page 51
Chapter 2 How to use the menu CVS-128/128B
When setting to “No display of operation guide”, the echo sounder image can be easily seen at the menu operation.
1 Press the [MENU] key. 2 Select the [System] [Operation guide].
(See [2.1 How to operate the menu])
3 Press the [ ] key. 4 To display the Operation guide, select [ON].
To stop the display of Operation guide, select [OFF]. (Press the [
] key or [ ] key)
5 Press the [MENU] key to close the menu.
Display the detection area/Stop the display of detection area
The range of the search that can be detected in the angle of beam spread of the transducer used can be displayed.
1 Press the [MENU] key. 2 Select the [Display2] [Detection area].
(See [2.1 How to operate the menu])
3 Press the [ ] key. 4 To display the Detection area, select [ON].
To stop the display of Detection area, select [OFF]. (Press the [
] key or [ ] key)
5 Press the [MENU] key to close the menu.
Caution: The beam angle of transducer
is different depending on the transducer. (See [3.3 Setting of Correct Item, Directirity angle (Low/High)].)
Setting of Scale display
The set of the scale display
1 Press the [MENU] key. 2 Select the [Display2] [Scale display].
(See [2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [Scale display]. (Press the [ ]
key or [
] key)
5 Press the [MENU] key to close the menu.
Change the scale value
The display size of the scale value can be changed.
1 Press the [MENU] key. 2 Select the [Display2] [Scale]. (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Select the [Scale]. (Press the [ ] key or
[
] key)
5 Press the [MENU] key to close the menu.
Change the image direction
The direction of display image can be changed.
1 Press the [MENU] key. 2 Select the [Display2] [Image direction].
(See [2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [Image direction]. (Press the [ ]
key or [
] key)
5 Press the [MENU] key to close the menu.
Setting of Depth measurement
Select the method for depth measurement, which is shown on the display.
1 Press the [MENU] key. 2 Select the [Display2] [Bottom detection].
(See [2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [Bottom detection]. (Press the
[
] key or [ ] key)
5 Press the [MENU] key to close the menu.
Change the display color
The display color can be changed.
1 Press the [MENU] key. 2 Select the [Display2] [Color table 1] or
[Color table 2]. (See [2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [Color table]. (Press the [ ] key
2-16 0093112802-06
Page 52
CVS-128/128B Chapter 2 How to use the menu
or [ ] key)
5 Press the [ ] key.
6 Select the color. (Press the [ ] key or [ ]
key)
7 Press the [MENU] key to close the menu.
Setting of Key lock
Disable the functions of controls and keys to avoid deviation of these settings by unintentionally touching them during operation.
1 Press the [MENU] key. 2 Select the [System] [Key lock]. (See [2.1
How to operate the menu])
3 Press the [ ] key. 4 Select the [Key lock]. (Press the [ ] key or
[
] key)
5 Press the [ ] key. 6 Select the [ON] or [OFF]. (Press the [ ]
key or [
] key)
7 Press the [MENU] key to close the menu.
key or [
Black 0, , , 176, , , 255 Red
] key)
5 Press the [MENU] key to close the menu.
Change the image partition
The image partition of echo sounder can be change to "Horizontal split" or “Vertical split”.
1 Press the [MENU] key. 2 Select the [Image] [Image partition].
(See [2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [Image partition]. (Press the [ ]
key or [
] key)
5 Press the [MENU] key to close the menu.
Display the frequency / Stop the display of frequency
The frequeny of the transducer currently in use can be displayed.
Change the scale type
The interval of indications of scale can be changed.
1 Press the [MENU] key. 2 Select the [Display2] [Scale type]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [Scale type]. (Press the [ ] key
or [
] key)
5 Press the [MENU] key to close the menu.
Change the bottom color
The dark red color of sea bottom can be changed.
1 Press the [MENU] key. 2 Select the [Display2] [Color table 2]
[Bottom color]. (See [2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [Bottom color]. (Press the [ ]
1 Press the [MENU] key. 2 Select the [Display2] [Freq display].
(See [2.1 How to operate the menu])
3 Press the [ ] key. 4 To display the Freq display, select the [ON].
To stop the display of Freq display, select the [OFF]. (Press the [
] key or [ ] key)
5 Press the [MENU] key to close the menu.
For CVS-128B
Selecting a display area of fish symbol indication
The fish symbol can be displayed either on side A or on side B, or on both sides, by the following operation.
1 Press the [MENU] key. 2 Select the [Image] [Fish image]. (See
[2.1 How to operate the menu])
3 Press the [ ] key. 4 Select the [A|B], [A| ], [ |B]. (Press the [ ]
key or [
] key)
5 Press the [MENU] key to close the menu.
0093112802-06 2-17
Page 53
CVS-128/128B Chapter 3 How to use the menu2
A
A
A
A
A
A
A
Chapter 3 How to use the menu2
3.1 Display of Menu
After powering on, besides the menu displayed first with the [MENU] key, there are the other menus as follows, of which setting does not need to be frequently changed.
[In out], [Correct], [Setting], [Maintain]
Display the menu
1 Press the [MENU] key. 2 Select the [Next].
djust
D.range Display1
Display2
larm1
larm2 NAV Image System
Freq* Next
* For CVS-128B
3 Press [ ] key to display the system menu.
Prev In out Correct Setting Maintain
* For CVS-128B
Return to the normal menu
Select the [Prev].
1 2 Press the [ ] key to display the normal
menu.
In out Correct Setting Maintain
djust2
djust
D.range Display1 Display2
larm1 larm2
NAV Image Freq* System
3.2 Setting of External Input / Output
Set the setting related to the input/output.
Prev In out Correct Setting Maintain
Buzzer Setting
Set the buzzer sound to ON/OFF.
Temp Source
Switch the Sensor/NMEA. For setting of [SENSOR], use an internal water
thermometer connected to the water temperature sensor with J6 connector.
For setting of [NMEA], use the input value from outside connected with NMEA of power connector.
Speed Source
Switch the Sensor/NMEA. Use the built-in speed meter for sensor. Use the external input value for NMEA.
Baud Rate
Change the transmission speed of external input/output.
Match the transmission speed with that of external equipment connected. (Setting: 4800, 9600, 19200, 38400)
Buzzer setting Temp source Speed source Baud rate NMEA monitor NMEA output data NMEA output data Return
OFF InsideSensor InsideSensor 4800 OFF
0093112802-06 3-1
Page 54
Chapter 3 How to use the menu2 CVS-128/128B
NMEA Monitor
The external input data can be displayed. To return to the original menu, press the [MENU]
key.
Caution: When [GAIN (HF) Knob] is
pressed, the displayed data will stop.
NMEA Output Data
The output of NMEA sentence can be set to ON/OFF.
1 Select [In out] [NMEA output data]. (See
[2.1 How to operate the menu].)
2 Press the [ ] key. 3 Select the sentence name.
4 Press the [ ] key.
Prev In out Correct Setting Maintain
Prev DBT DPT GGA MTW TLL VHW
VTG ZDA Return
ON ON OFF OFF ON OFF OFF
OFF
3.3 Setting of Correction Item
Prev
In out Correct Setting
Maintain
Draft Set
The tolerance of depth can be corrected. Set the depth from the sea level to the set depth
of your transducer . Normally set draft value of your boat. (Setting: expect ft: - 10.0 to 10.0, ft:
-30.0 to 30.0)
Sonic Speed
Set the [Seawater] or [Freshwater]. Change to meet the usage.
Draft set Sonic speed Water temp Boat speed Beam width H
Beam width L Size adjust Detect adjust f
Bubble Bubble time set
Return
0.0m Seawater
0.0°C 0%
17° 50°
6
4
OFF 5 minutes
5 Select the ON/OFF.
DBT
OFF
ON
6 Press the [ ] key to turn to the display to
select the sentence name.
7 Further pressing of [ ] key turns to the
display to select the NMEA output.
8 Press the [MENU] key to close the menu.
Water Temp
The error of water temp value can be corrected. (Setting: - 10.0 to 10.0 ˚C, - 10.0 to 10.0 ˚F)
Boat Speed
The tolerance of boat speed value can be corrected.
When the [Speed source] is set to [Sensor], it is corrected by %. (Setting: - 50 to 50 %)
When the [Speed source] is set to [NMEA], it is corrected by numeral. (Setting: - 10.0 to 10.0)
Directivity angle (Low/High)
Directivity angle of transducer which you use should be input for high and low frequency respectively.
3-2 0093112802-06
Page 55
CVS-128/128B Chapter 3 How to use the menu2
A
A
Bubble
Bubble-prevention process can be activated by setting [Weak] or [Strong].
Bubble time set
While auto-range or auto-shift is in use, and if the missing image is caused by bubble, range and shift continues changes until sea bottom is detected by auto mode. Setting the bubble time duration holds the range or shift at the level when bubble started. If bubble disappears and sea bottom is detected, range or shift returns to auto mode. This makes the time shorter until the image comes back to normal. After the specified time, the mode returns to the previous auto-range or auto-shift. (Setting: OFF, 1minutes to 10minutes)
3.4 Setting of Basic Set Item
Temperature Unit
It switches the unit of temperature to ˚C, °F.
Local time Offset
The local time offset can be set by 0.5 hours (30 minutes) unit. (Setting: - 11.0 to 14.0 h) (UTC: 0.0)
GPS select
It selects whether the GPS sensor is the KODEN made one or not.
Caution: Only when connecting the
Koden GPS sensor to the equipment directly, select [KODEN GPS]. When connecting the GPS sensor even Koden one) via Plotter etc to the equipment, select [Other].
GPS initialize
Prev In out Correct Setting Maintain
Language
Range&Speed unit
Depth unit Temperature unit Localtime offset GPS select GPS initialize
Return
English
NM,kn m
°C
.
0.0 Others No
Language
Switch to the language to be displayed.
Caution: [Language] is displayed in red
characters.
Range & Speed Unit
It switches the display unit to [NM, kn] or [km, km/h].
Depth Unit
It switches the unit of depth to m, fm, l.fm and ft.
It is valid only when KODEN GPS is connected. The GPS sensor is initialized.
Caution: When connecting the GPS
sensor other than KODEN GPS, do not use this item.
3.5 Maintenance Menu
Prev In out Correct Setting Maintain
* For CVS-128B
Simulation Slideshow Initialize System check
ll WPTs:DLT
ll IMG DT:DLT Bottom start Past image* ON
Inner-hull TD select* Return
Simulation
When the [Simulation] is set ON, the pseudo image of echo sounder is displayed.
OFF OFF No
1.5 No
TDM-091D
0093112802-06 3-3
Page 56
Chapter 3 How to use the menu2 CVS-128/128B
A
Slide show
The slide show of the images stored in [Image] [Image recall] is available. The time intervals for image changeover can be selected from 15 seconds and 30 seconds.
Caution: To perform slide show,
registration in the list of image memory is required. When it is not registered, slide show cannot be selected.
Initialize
It returns all the settings in the menu to the factory settings. However, the memorize d data of display remains unchanged.
Caution: It returns to the factory settings
and the power is automatically shut down.
System Check
It is used for diagnostic test. (See [4.5 Dia
gnostic Test])
All WPTs deletes
All WPT lists can be deleted.
All stored image deletes
All stored image lists can be deleted.
Bottom start
Set up the starting depth of the seabed detection.Once set, the fish echo or the seabed shallower than set up depth will not be detected.
Inner-hull
When the installation of a transducer is [Inner-hull], select the [Yes].
Caution: When a setting is altered, the
value of Gain (TD) will be initialized.
TD select
Choose the installed transducer (TD) in the menu list.
Caution: When transducer is choosen by
model name, [Beam angle] value (directivity angle) is changed automatically depending on the transducer.
For CVS-128B
3.6 Setting of Adjust2 Item
Prev In out Correct Setting Maintain
djust2
STC strength H STC depth H STC strength L STC depth L Color adjust
Image speed adj Bottom limit Return
The visivility of the fish school echo can be adjusted by STC setting.
Adjustment can be done for high-frequency and low-frequency independently.
0.0 50
0.0 50
0
1.0
Past image
When the [Past image] is set to ON, the gain control is effective for all screens including the past image. When the [Past image] is set to OFF, the gain control is effective for current image only.
For CVS-128B
STC strength adjust Low / High
Set smaller values for higher sensitivity.
STC depth adjust Low / High
Depth limitation of STC adjustment. Unit: Meter
STC can be operated from 0 to the setting depth.
3-4 0093112802-06
Page 57
CVS-128/128B Chapter 3 How to use the menu2
A
A
A
A
Color adjust
Rainbow pattern of the echo image can be changed.
Set the value of each color in the range from 0 to 99%. Confirm color distribution by the rainbow pattern of the left side of the screen.
Prev In out Correct Setting
Maintain
djust2
EXAMPLE: When the yellow value is change from 60 to 80 in the setting, the Rainbow pattern becomes as shown below.
Prev
Red Orange
Yellow
Green Sea green Light blue
Marine blue Return
95 90 60
30 20
15
5
EXAMPLE: Displayed 20 m, setting value: 2.0, a bottom can be detected up to approximetery 40m.
Caution: If the setting value is increased,
the image speed becomes slower .
Sounding
Sounding is performed up to the maximum depth set during auto range is in operation. The maximum range is 800 m. At the initial setup, the range is up to 200 m for CVS-128 and up to 500 m for CVS-128B. (Setting: m: 10 to 800, I.fm: 10 to 600, fm: 10 to 400, ft: 10 to 2800)
3.7 Frequency Select
djust
D.range Display1
Display2
larm1
larm2 NAV Image System
Freq* Next
* For CVS-128B
Freq select (L)* Freq select (H)* Power freq adj* Return
42.0
210.0
107.0
Before the change
After the change
Image speed adjust
The image speed can be adjusted. The image speed becomes faster in a minus
direction, and slower in a plus direction.
Caution: Image speed cannot set faster
than the maximam speed value.
Bottom limit
The detection of sea bottom can be changed. Sea bottom can be detected up to the range of
display multiplied by the setting value.
Frequency select (Low / High)
The frequency of the connected transducer (low frequency and high frequency) is chosen.
Caution: Do not choose a frequency
different from the frequency of the connected transducer.
Caution: When the frequency out of the
specified range is choosen, the setting value is displayed in a faded color.
For CVS-128B
0093112802-06 3-5
Page 58
Chapter 3 How to use the menu2 CVS-128/128B
Power frequency adjustment
It is necessary to adjust power frequency when noise appears on the image. The value for adjustment depends on the frequency of the transducer.
Caution: Power frequency adjustment is
for internal noise, so there is no effect for external noise.
For CVS-128B
3-6 0093112802-06
Page 59
CVS-128/128B Chapter 4 Maintenance and Inspection
Chapter 4 Maintenance and Inspection
4.1 Inspection
The daily maintenance and inspection extends the life of equipment. To always keep the equipment in the best condition, implement periodically the inspection shown in the table below.
Item Content of Inspection
Connector at the rear of CVS-128/128B Display unit
Wiring of cables Check the wiring of cables connecting the equipm ent and the
Grounding of display unit Scrape the rust off the ground terminal and make its contact well.
4.2 Cleaning
Check the looseness.
damage of cable.
CVS-128/128B Display unit
Contamination on the screen may cause faint images. For cleaning the screen, wipe the screen with soft and clean cloth dipped with diluted neutral detergent. Pay full attention as the screen is easily getting scratched. No thinner shall be used.
The display unit has a special coating. Do not use a solvent such as
Caution
For cleaning the housing, do not use plastic solvent such as thinner or alcohol. Painting on the surface and characters at the operating portion may melt. After wiping with soft and clean cloth dipped with diluted neutral detergent, wipe away with dry soft and clean cloth.
paint thinner, acetone, alcohol, and benzene, etc. Strong rubbing may cause bruising or scratching.
T ransducer
In case of through-hull equipped transducer, check the surface of opening of transducer (portion from which the ultra-sonic is emitted). If shells and oil are stuck, scrub the surface with a wooden o r bamb oo knife with caution not to damage the surface and remove stuck materials. If you scrub strongly, the surface will be damaged, resulting in deteriorated performance of transducer.
0093112802-06 4-1
Page 60
Chapter 4 Maintenance and Inspection CVS-128/128B
4.3 Fuse Replacement
Warning
If the input voltage is too high, the over-current flows or a trouble occurs inside, the fuse will blow out. The fuse is housed in the power cable.
Use the specified fuse. If you use a fuse other than specified one, it may lead to a serious accident.
4.4 If you suspect a trouble
Symptom Possible cause of trouble Countermeasure
Even if the power is powered on, nothing is displayed.
The unit starts up. But, nothing is displayed on the display.
Too much interference and noise.
The display of water temperature / boat speed is abnormal or not displayed.
The display of present location/course is abnormal or not displayed.
Blown fuse. The power voltage is out of
specification (10.8 to 31.2 VDC).
Poor connection between
power cable and battery.
Connection between
transducer and display unit.
Defect of LCD display block.
Installed position of
transducer.
Interference from the echo
sounder on other boat.
Connection of sensor
connector.
Input source of water
temperature sensor / speed sensor.
Connection between this unit
and navigation equipment.
Exchange a fuse.(See [4.3 Fuse
Replacement])
Use a proper power as per
specification.
Confirm a connection between the
power cable and the battery.
Confirm a connection between
Transducer and Display unit.
Consult a repair shop or the
distributor in your market.
Confirm the position of transducer.
(See [5.3 Installation of Transducer])
Apply the interference rejection.
(See [2.3 Rejection of Interference])
Confirm the connection of the sensor
connector.
Confirm the input source.
Confirm a connection between
Display unit and the navigation equipment.
4-2 0093112802-06
Page 61
CVS-128/128B Chapter 4 Maintenance and Inspection
4.5 Diagnostic Test
Perform the operation diagnosis. To check the operation diagnosis of panel key,
the state of sensor inside and the version of software.
Confirm the version
3 displays the information on the version of
software. When inquiring, inform us of Ver XX.XX. KM-E79 Ver.xx.xx in case of CVS-128 KM-F22 Ver.xx.xx in case of CVS-128B
Return to the menu
Press the [MENU] key for more than 3 seconds.
LCD Test
Diagnose
1 displays the diagnostic result.
The result of ROM and RAM check displays OK when normal and NG when abnormal.
Caution: To test the NMEA, TEMP and SPEED, the special checker is necessary.
2 implements the key input test. When pressing the key, the color of a part corresponding to the pressed key changes.
When pressing the [GAIN (HF)], the LCD test is performed.
0093112802-06 4-3
Page 62
CVS-128/128B Chapter 5 Installation
Chapter 5 Installation
5.1 Items of Caution on Installation
To realize the full performance of echo sounder, the installation of CVS-128/128B must be performed by an engineer who is officially authorized by our company. The installation wo rk include s the following content.
(1) Unpacking the components (2) Inspection of configuration unit, spare, accessories and material for installation (3) Check of power voltage and capacity of current (4) Decision of installing location (5) Installation of Display unit and transducer (6) Installation of accessories (7) Plan and execution of cable laying and connection (8) Adjustment after completion of installation
Unpacking the components
Unpack the components and confirm that all of the items match with the contents on the equipment configuration list. If not matched, contact the dealer you purchased or our sales company.
Inspection of components and accessories
Inspect the appearance of each components and accessori es and check that no dents or damage exist.
If any dents or damage exist and they are believed to be caused by accident during tran sportation, contact the transportation and insurance com pany and consult our sales company or our dealer nearest to you.
Decision of Installing Location
To realize the full performance of equipment, install the equipment, considering the points mentioned below.
(1) Install the equipment at the location in the bridge so that its display can be easily seen. (2) Select a safe location where the equipment is not exposed to humidity, water splash, rain and
direct sunshine.
(3) Keep enough space for maintenance. Especially, secure enough space at the rear panel wh ere
many cables are concentrated.
(4) Keep the equipment as far away from the wireless transmitter/receiver as possible.
The equipment is not waterproof. A void excessively damp pla ce. Do not install the equipment in the place suffering from excessive waterdrops. Otherwise, the corrosion may occur inside.
0093112802-06 5-1
Page 63
Chapter 5 Installation CVS-128/128B
/
Laying and Connection of Cable
(1) Keep the transducer and power cable as far away from the cables of other electronic equipment
as possible.
(2) The cabinet of Display unit shall be securely grounded to the hull, using the ground terminal on
the rear panel.
Caution: The ground side of power input of this equipment is connected to the ground
terminal. In case of + (positive) ground, it cannot be used. The power may short-circuit.
(3) If you connect the power cable directly to the battery, the interferen ce from other electronic
equipment is not subject to occurrence. (See Fig. 5.1.)
Display unit
Good example
Battery Battery
CVS-128 CVS-128B
Noise
Bad example
Display unit
CVS-128/ CVS-128B
Noise
Fig. 5.1 Connection of Power Line
Confirmation after Installation
Be sure to confirm the following items before starting u p this equipment. The confirmation i s mandatory to operate the equipment normally.
(1) Is the power voltage in the boat within the appropriate voltage range? Is the current capacity
enough?
Voltage Range: 10.8 to 31.2 VDC when measured at the power connector input. (2) Is the electric current capacity sufficient? (Power consumption: 25 W) (3) Is the wiring of transducer cable correct? Is the wiring shorted?
5-2 0093112802-06
Page 64
CVS-128/128B Chapter 5 Installation
5.2 Installation of CVS-128/128B Display unit
CVS-128/128B Display unit can be installed either on desk-top or flush-mounted. Install in the following procedure.
Desk-top Installation
(1) Remove two knob bolts fixing the display unit to the bracket. (2) Remove the display unit from the bracket and place it on the stable flat place. (3) Place the bracket on the position where the display unit will be installed and fix the bracket with five
5 mm screws.
(4) Place the display unit on the installation bracket and fix the display unit with two knob bolts
removed in step 1.
Display unit
Installation bracket
Knob bolts
1
2
(4
5
5
9
/
6
4
)
1
2
(
Fig. 5.2 Desk-top installation
5
4
5
9
/
6
4
)
(
1
4
1
4
)
4
6
/
9
3
1
)
4
6
/
9
3
1
(
Unit: mm (inch)
0093112802-06 5-3
Page 65
Chapter 5 Installation CVS-128/128B
Caution: When installing on the desktop, the maintenance space shown in the illustration
below is required for cable lay-out, plugging-in/out of connector, fuse replacement and bolt tightening.
Fig. 5.3 Maintenance space
5-4 0093112802-06
Page 66
CVS-128/128B Chapter 5 Installation
Flush-mount Installation
(1) Make a square hole at the location to be installed. (See Fig. 5.5.) (2) Turn counter-clockwise the knob bolt fixing the display unit to the mounting bracket to loosen it,
push the unit to the left side and pull the unit upward. The mounting bracket and knob bolt are not
used. (3) Confirm that the unit matches with the square holes. If not matched, correct the square hole. (4) Remove the front frame of the display unit, pulling it toward you. (See Fig. 5.4.) (5) Connect the connectors for power and transducer to the unit respectively. (6) Install the display unit in the installing location (square hole) and fix it with four tapping screws
(4mm) (M4 or pan-head). (Prep are 4mm screws suitable for thickness of installing location.) (7) Install the front frame removed in step (4).
2
2
(
0
8
2
1
/
3
2
)
Threading hole
Fig. 5.4 Flush-mount Instsllation
Unit:mm (inch)
4-4mm (4-5/32) Hole for screw
Fig. 5.5 Work of fiush-mount instsllation hole
(8 21/32)
R25 (63/
64)
Threading
hole
(8 13/16)
220
224
Unit: mm (inch)
0093112802-06 5-5
Page 67
Chapter 5 Installation CVS-128/128B
5.3 Installation of Transducer
The standard installation of the transducer is shown in figure 5.6.
Figure 5.6 Installation of T r ansducer
In case of Inner-hull
Using the optional inner-hull kit (MFB-04), install the transducer to the inner side of ship’s bottom.
Caution on installation
(1) Select the location where no bubble is generated during navigation.
(2) Select the relatively thin location of ship’s bottom.
(3) Be sure to remove oil on the contact surface. File the contact surface with sand paper (#400) so that the adhesive strength will increase.
(4) The adhered surface will dry in about two hours.
(5) Leave the unit for a whole day and fill in the coolant. More than 80 % of the transducer should be submerged in the coolant.
Figure 5.7 Inner-Hull installation
Caution: It is strongly recommended to confirm the location of the installation of Inner-hull
with the ship manufacturer. The Inner-hull device is more simplified method. The gain falls dramatically in comparison with the Through -hull performance. Low frequency (50 kHz) may not be used due to large signal attenuation in some cases. Depth range performance using 200 kHz Transducer in case of Inner-hull can be less about 50% than that of Through-hull.
Caution: Fishing boats may have structure with FRP contained air bubbles and foamed
materials that would prevent ultrasound from penetration. Therefore, the location convenient for installation may not be locations where attenuation of ultrasound is low enough.
5-6 0093112802-06
Page 68
CVS-128/128B Chapter 5 Installation
r
r
In case of Through hull
Install the transducer directly to the ship’s bottom
Installation Procedure
(1) Select the installing location. (2) Remove the fixing nut and one piece of rubber packing. (3) If the slope of ship’s bottom is greater than 5°, make a wooden base to fit to the slope of ship’s
bottom. To reduce the water resista nce, cut the b ow direction tip of wooden base at the outer side
of ship’s bottom in the triangle shape. (4) Make holes at the installing location. If the wooden base is used, make holes in the wooden base. (5) Thread the rubber packing in the transducer and then the cable. (6) To prevent water from seeping through the gap between the transducer and the hole, fill out the
gap with FRP or silicon glue. (Glue the wooden base likewise.) (7) Thread the rubber packing and fix it with the fixing nut firmly. (8) Connect the transducer cable to the connector of Display unit.
Fixing nut
Rubber packing
In case that the slope of ship
Rubber packing
Ship,s bottom
Transduce
Less than 5
,
s bottom is less than 5
Figure 5.8 Through-hull Installation
Fixing nut
Wooden base
Rubber packing
Transduce
In case that the slope of ship,s bottom is greater than 5
Rubber packing
Wooden base
,
s bottom
Ship
0093112802-06 5-7
Page 69
Chapter 5 Installation CVS-128/128B
A
A
A
A
5.4 Wiring
Connection of Cable to CVS-128/128B Display unit
Connect the power cable and transducer to the connectors of CVS-128/128B Display unit.
Power input
10.8 to 31.2VDC
NMEA data input output
GPS, plotter etc
Sona-Tone
Line output for speaker with amplifier
Power output
For power of GPS etc
Transducer
For 50/200kHz in common
・Speed sensor data input ・Water temperature sensor data input
TM
output
Pin Assignment of Rear Connector
Pin assignment viewed from the rear of Display unit.
POWER
Caution: Do not connect each wire to ship’s earth.
Sona-ToneTM R Sona-ToneTM L Power + Outside power (-) NMEA TX-
T
NME NME NME Power ­Shield Sona-Tone Outside power (+)
X+
R
X+
RX-
TM
COM
J6
J7
External monitor
nalog RGB
Speed sensor input Speed sensor power (+) Transducer input output Transducer shield Transducer input output Water temperature sensor power Water temperature sensor input Speed sensor power (-)
R
R-GND G G-GND B B-GND H-SYNC V-SYNC Un-connected Un-connected
5-8 0093112802-06
Page 70
CVS-128/128B Chapter 5 Installation
Connection of Power Cable
Connect the power cable to the [POWER] connector and the transducer to the [J6] at the rear of Display unit connector.
Connection of DC power cable (CW-264A-2M)
To [POWER] connector
Caution: Wind the insulation tape around th e un-used lead wire for core- wires not to contact
each other.
3.5 stereo jack
DC+ (Red) DC- (Black)
Grounding
Use heavy gauge cable for grounding wire. Connect the grounding wire to the grounding material in a short distance. When connecting the external equipment of which positive polarity is conne cted to the ground line,
do not connect the ground of signal line to the cabinet ground.
0093112802-06 5-9
Page 71
Chapter 5 Installation CVS-128/128B
Connection of Transducer
At the end to the transmission/receiving cable for TD-500T -2B, TD-500T-3B, TD-501T -3B, TDM-07 1 and TDM-091D a water proof connector with 8-core is provided.
At the end to the transducer for TD-501C is plain.
1) TD-500T-2B/500T-3B/501T-3B/TDM-071/TDM-091D
Connect to the J6 connector on the back of the receiver display unit.
2) TD-501C
The user must have the cable, CW-840-0.3M for the transducer.
Solder the transducer to CW-840-0.3M while referring to the table on connecting transduce rs. After soldering is completed, please be sure to add water-resistance and insulation by applying
electrical tape (or other such t ape) onto the soldered part of the cable.
Transducer Connection Table
Transducer Cable Transducer
2 lead shield wire number 2 lead shield wire color TD-501C
3 orange black 4 shield shield 5 white white
CW-840-0.3M
2 lead shield
3 TD1 (orange)
4
Shield
5 TD2 (white)
To Transducer
Lead wires
1 SPD.PULSE (blue) 2 SPD.VCC (violet)
8 SPD.GND (black)
6 TEMP.VCC (green) 7 TEMP.SIG (red)
To Speed Sensor
To Temperature Sensor
Caution: Wind the insulation tape around th e un-used lead wire for core- wires not to contact
each other.
5-10 0093112802-06
Page 72
CVS-128/128B Chapter 5 Installation
Connection with external equipment
The DC power cable contains the connection cables for external equipment such as navigation equipment and KODEN GPS sensor.
Color Pin Remark
Red 3 Power +
Black 9 Power -
Orange 6 NMEA TX +
Blue 5 NMEA TX -
White 7 NMEA RX +
Green 8 NMEA RX -
Color Pin Remark
White 2
Red 1
Black 11
Yellow 12 Outside power (+)
Gray 4 Outside power (-)
Shield 10
Sona-Tone External speaker output (with ø3.5 stereo jack)
TM
Connection with GPS-20A
After soldering, implement the waterproof and insulation treatment on the connected part with the self-melting tape.
Color Remark Color
Orange
CVS-128/128B
DC power cable
(CW-264A-2M)
NMEA TX +
GPS-20A (No Type)
Connecting up without using a
connector
Orange
GPS-20A (Type B)
Connecting up using a
connector*
Pin
2
Blue
White Green Yellow Outside power (+) Red
Gray
NMEA TX ­NMEA RX + NMEA RX -
Outside power (-)
Blue
White
Green
Black
3 4 5 6 1
*Optional connector (LTWBD-06PMMP-LC) is necessary.
0093112802-06 5-11
Page 73
Chapter 5 Installation CVS-128/128B
Connection with Speed Sensor or Water Temperature Sensor (Option)
When installing the optional speed sensor or water temperature sensor, connect to the [J6] connector together with the transducer via the transducer cable (Type: CW-840-0.3M). For wiring, see the figure below.
After soldering, implement the waterproof and insulation treatment on the connected part with the self-melting tape.
Structure of Transducer Cable
2 core shield wire
lead wire
TD1 (Orange)
Shield
TD2 (White)
SPD.PULSE (Blue) SPD.VCC (Violet)
SPD.GND (Black)
TEMP.VCC (Green)
TEMP.SIG (Red)
To Transducer
To the speed sensor
To the water temperature sensor
Caution: Wind the insulation tape around th e un-used lead wire for core- wires not to contact
each other.
Connection Table of Transducer
Transducer Cable Transducer
No. of 2 core shield Color of 2 core shield TD-500T-2B
TD-500T-3B
TD-501T-3B
TD-501C
3 Orange Red Black 4 Shield Shield Shield 5 White White White
Connection Table of Speed Sensor and Water Temperature Sensor
Transducer Cable Water Temperature Sensor / Speed Sensor
No. of lead
wire
1 Blue — Green Green Green 2 Violet — Red Red Red 6 Green Gray White White White 7 Red Gray Brown Brown Brown 8 Black — Shield Shield Shield
Caution: No.8, SPD.GND (Black), only use for speed sensor.
Do not connect with other grounding wire.
5-12 0093112802-06
Color of lead
wire
T-81 ST-80
ST-80-1
ST-90-1
ST-90
ST-100
ST-100-1
Page 74
CVS-128/128B Chapter 5 Installation
Connection of External Speaker for Sona-ToneTM (Prepared by a customer)
The ø3.5 stereo jack is provided to the power cable. If you connect the speaker with the amplifier to the external, you can clearly hear the Sona-Tone sound. Adjust the volume of speaker with the amplifier equipped to the speaker
3.5 stereo jack
TM
Connection of External Monitor (J7) (Prepared by a customer)
When installing an external monitor (VGA monitor, analog RGB input), connect it via CW-576-0.5M. For its wiring, refer to the illustration below.
Structure of CW-576-0.5M
Nonuse
0093112802-06 5-13
Page 75
Chapter 5 Installation CVS-128/128B
5.5 Serial Data
Input Data
The sentences of GGA, GLL, HDT, MTV, MWV, RMC, VHW, VTG and ZDA can be received. The type of NMEA0183 Ver.1.5, Ver.2.0 and Ver.3.0 can be input.
Information Priority Order of Sentence Information Priority Order of Sentence Latitude,
Longitude Course VTG > RMC Wind Speed MWV Heading HDT Date ZDA > RMC Ground Spee d VTG > RMC Time ZDA > GGA Water Speed VHW Water
Output Data
The sentences of DBT, DPT, GGA, GLL, HDT, MTW, MWV, RMC, TLL, VHW, VTG and ZDA can be transmitted. The output is performed in the type of NMEA0183 Ver.2.0. However, the DBT is performed in Ver.1.5.
GGA > RMC > GLL Wind Direction MWV
MTW
Temperature
Sentence Information Sentence Information DBT Depth MWV Wind Direction, Wind Speed DPT Depth from the transducer RMC Latitude/Longitude, Course,
Ground Speed, Date GGA Latitude/Longitude, Time TLL Target Position GLL Latitude/Longitude VHW Water Speed HDT Heading VTG Course, Ground Speed MTW Water Temperature ZDA Date,Time
5-14 0093112802-06
Page 76
CVS-128/128B Chapter 6 Table Attached
y
y
t
Chapter 6 Table Attached
6.1 Menu List
The factory set value is shown by the bold and underline.
[Disp] key
▲RANGEkey
[GAIN(HF) ], [GAIN(LF) ]
Disp
RANGE
Gain selec
Auto adjust
Gain
NAV1, Normal (H), Zoom (H), Dual freq, Zoom (L), Normal (L), NAV2
Auto range, 5.0, 10.0, 20.0, 50.0, 100, 160, 300, 500, Auto shift
Manual, Cruising, Fishing
- 30 to 10 (H): 0, (L): 0
0.0 to 10.0 (H): 6.0, (L): 6.0
[BRILL] key
[EVENT] ke
[F1] ke
[F2] key
LCD brill
Panel brill
1 to 10: 10
1 to 10: 10
Store pos, Store image, Fishing hot spot
Image speed, IR, Color rejection, Noise rejection, Shift, Zoom range,
Zoom start, A scope, White line, Background color, Disp width,
NAV start, NAV1, NAV2, Image swap, Image recall, Sona-tone
Image speed, IR, Color rejection, Noise rejection, Shift, Zoom range,
Zoom start, A scope, White line, Background color, Disp width,
NAV start, NAV1, NAV2, Image swap, Image recall, Sona-tone
0093112802-06 6-1
Page 77
Chapter 6 Table Attached CVS-128/128B
A
t
t
[MENU] key
djus
Image speed (Speed1, Speed2, Speed3, Speed4, Stop, Speed5 (1/1), Speed6, Speed7,
Speed8, Speed9)
IR (OFF, Weak, Strong : Strong (For CVS-128) , Weak (For CVS-128B))
Color rejection (0 to 50 %: 0%)
Noise rejection (0 to 10: 0)
TVG (Weak, Medium, Strong)
TX power (20, 30, 40, 50, 60, 70, 80, 90, 100, Auto)
A
D.range
Display1
Display2
Gain (TD) (-50 to 50)
Inner-hull : No
H: 0, L: 0
Inner-hull : Yes
H: 15, L: 30
Pulse width (Super short, Short, Middle, Long) (For CVS-128B) Band width (Super narrow, Narrow, Middle) (For CVS-128B)
D.Range (12dB to 30dB: 24dB) (For CVS-128B)
Shift step (1m, 10m, 1/8, 1/4)
Zoom type (Bottom, Bottom Discrimination, Zoom, Bottom Zoom, Bottom Follow Zoom)
Zoom range (2.5 to 200 m: 10.0 m)
Zoom start (0 to 800 m: 0m)
Disp width (Left2, Left1, Center, Right1, Right2)
Range prese
Inner-hull : No
Range 1 (2.5 to 1200 m: 5.0)
Range 2 (2.5 to 1200 m: 10.0)
Range 3 (2.5 to 1200 m: 20.0)
Range 4 (2.5 to 1200 m: 50.0)
Range 5 (2.5 to 1200 m: 100)
Range 6 (2.5 to 1200 m: 160)
Range 7 (2.5 to 1200 m: 300)
Range 8 (2.5 to 1200 m: 500)
Inner-hull : Yes
Range 1 (2.5 to 1200 m: 5.0)
Range 2 (2.5 to 1200 m: 10.0)
Range 3 (2.5 to 1200 m: 20.0)
Range 4 (2.5 to 1200 m: 50.0)
Range 5 (2.5 to 1200 m: 80)
Range 6 (2.5 to 1200 m: 100)
Range 7 (2.5 to 1200 m: 160)
Range 8 (2.5 to 1200 m: 200)
A scope (OFF, ON)
White line (OFF, 1, 2, 3, 4, 5, Auto)
Background color (Pale blue, Marine blue, Blue, Dark blue, Black, Darkkhaki,
Mediumseagreen, Light grey, White, Night mode)
Color tone (Monochrome, 8 color, 16 color, 64 color)
Depth value (OFF, Small, Middle, Large) Unit display (OFF, ON) Water temp graph (OFF, ON)
Fish symbol (OFF, Symbol 1 to Symbol 10)
Symbol info (OFF, Depth, Size, Bottom<=>Fish)
Detection area (OFF, ON)
Scale display (OFF, One, All)
Scale (Small, Middle, Large) Image direction (|← , →|→ , ←|→)
Bottom detection (Auto, High frequency, Low frequency)
Color table1 (Header information, Header BG color, VRM, Depth, Scale,
Scale line,Detection area H, Detection area L)
Color table2 (Symbol info, Menu BG color, Big fish color, Bottom color)
Scale type (0, 1)
Big fish (20 to 90: 50)
Freq display (OFF, ON) (For CVS-128B)
6-2 0093112802-06
Page 78
CVS-128/128B Chapter 6 Table Attached
V
k
A
Alarm 1
Alarm 2
NA
Image
System
Freq
B
Bottom alarm (OFF, ON)
Upper depth (0 to 800 m: 5 m)
Lower depth (1 to 800 m: 50 m)
Fish alarm (OFF, ON)
Position (0 to 800 m: 5 m) Range (1 to 800 m: 50 m)
Level (Weak, Medium, Strong)
Water temp alarm (OFF, ON (Inside), ON (Outside))
Upper temp alarm (- 5 to 45.0 °C: 20.0 °C)
Lower temp alarm (- 5 to 45.0 °C: 15.0 °C)
Speed alarm (OFF, ON (Upper), ON (Lower))
Speed limit (0 to 80 kn: 0 kn)
Arrival alarm (OFF, ON)
XTE alarm (OFF, ON)
NAV alarm range (5 to 999 m: 10 m)
NAV start (No.1 to No.10)
NAV cancel (Yes, No) WPT edit (No.1 to No.10)
WPT delete (No.1 to No.10)
Background color (OFF, White, Black)
NAV 1 (Normal (H), Zoom (H), Dual freq, Zoom (L), Normal (L))
NAV 2 (Normal (H), Zoom (H), Dual freq, Zoom (L), Normal (L))
Image swap (A|B, B|A)
Image recall (No.1 to No.10)
Image comment (No.1 to No.10)
Image delete (No.1 to No.10)
Image partition ( , )
Fish image (A|B, A| , |B)
EVENT key set (Store pos, Store image, Fishing hot spot)
F1 key set (Image speed, IR, Color rejection, Noise rejection, Shift, Zoom range,
Zoom start, A scope, White line, Background color, Disp width,
NAV start, NAV 1, NAV 2, Image swap, Image recall, Sona-ton)
F2 key set (Image speed, IR, Color rejection, Noise rejection, Shift, Zoom range,
Zoom start, A scope, White line, Background color, Disp width,
NAV start, NAV 1, NAV 2, Image swap, Image recall, Sona-tone)
Operation guide (OFF, ON)
Sona-tone (OFF, ON)
Key loc
Freq select (L) (24.0 to 210.0 kHz : 42.0) (For CVS-128B) Freq select (H) (24.0 to 210.0 kHz : 210.0) (For CVS-128B)
Power freq adj (100.0 to 130.0 : 107.0) (For CVS-128B)
0093112802-06 6-3
Page 79
Chapter 6 Table Attached CVS-128/128B
k
t
B
In ou
Correct
Setting
Maintain
Adjust2
Buzzer setting (OFF, ON)
Temp source: (InsideSensor, NMEA)
Speed source (InsideSensor, NMEA)
Baud rate (4800, 9600, 19200, 38400)
NMEA monitor (OFF, ON)
NMEA output data (ON : DBT, DPT, TLL OFF : GGA, MTW, VHW, VTG, ZDA)
NMEA output data (ON : None OFF : GLL, HDT, MWV, RMC)
Draft set (- 10.0 to 10.0 m: 0.0 m)
Sonic speed (Seawater, Freshwater)
Water temp (- 10.0 to 10.0 °C: 0.0 °C)
Boat speed (- 50.0 to 50.0 %: 0%) Beam angle H (1 to 120: 17°) Beam angle L (1 to 120: 50°)
Size adjust (1 to 10: 6)
Detect adjust f (1 to 6: 4)
Bubble (OFF, Weak, Strong) Bubble time set (OFF, 1 to 10minutes: 5minutes)
Language (English, Japanese, etc)
Range&Speed unit (NM, kn, km, km/h)
Depth unit (m, fm, I.fm, ft)
Temperature unit (°C, °F)
Localtime offset (- 11.0 to 14.0: 0.0)
GPS select (Others, KODEN GPS)
GPS initialize (No, Yes)
Simulation (OFF, ON)
Slideshow (OFF, 15, 30)
Initialize (No, Yes)
System chec
All WPTs: DLT (No, Yes)
All IMG DT: DLT (No, Yes)
Bottom start (0.0 to 20.0: 1.5) Past image (OFF, ON) (For CVS-128B)
Inner-hull (No, Yes) TD select (TDM-071, TDM-091D, Others TD) (For CVS-128B)
STC strength H (-10.0 to 10.0: 0.0)
STC depth H (2 to 1000: 40)
STC strength L (-10.0 to 10.0: 0.0)
STC depth L (2 to 1000: 40)
Color adjust (Red:90,Orange:78,Yellow:66,Green:53,Sea green:39,Light blue:25,
Marine blue:12)
Image speed adj (-10 to 10: 0)
Bottom limit (1.0 to 3.0: 1.0)
Sounding (10 to 800m: 200m(For CVS-128), 500m(For CVS-128B))
6-4 0093112802-06
Page 80
CVS-128/128B Chapter 6 Table Attached
6.2 Specification
0093112802-06 6-5
Page 81
Chapter 6 Table Attached CVS-128/128B
6-6 0093112802-06
Page 82
CVS-128/128B Chapter 6 Table Attached
6.3 Appearance
Plane view
0093112802-06 6-7
Page 83
Chapter 6 Table Attached CVS-128/128B
Dimension drawing of table installation
Hole for installing 4-4mm screw
R2
5
240
(9 29/64)
220
(8 21/32)
(
6
3
/
6
4
)
Threading hole
224
(8 5/32)
(8 13/16)
(8 13/16)
Unit: mm (inch)
Dimension drawing of flush-mount installation
6-8 0093112802-06
Page 84
Loading...