Kobold ZOE-ZB**FB series, ZOE-ZE**F3 series, ZOE series Operating Manual

Operating Manual
for
Flow-Totalizer
Model: ZOE
Page 2 ZOE K04/0718
1. Table of Contents
1.Table of Contents ......................................................................................... 2
2.Note .............................................................................................................. 3
2.1 Notice according to the Battery Law .................................................... 3
3.Instrument Inspection ................................................................................... 4
4.Regulation Use ............................................................................................. 4
5.Environment ................................................................................................. 4
6.Instrument / Functions overview ................................................................... 5
7.Electrical connections ................................................................................... 6
7.1 Cable entry for housing option -K ........................................................ 6
7.2 Overview of Terminals ZOE-ZX with Supply option B and 3 ............... 7
7.3 Power Supply ...................................................................................... 8
7.4 Sensor Inputs ...................................................................................... 9
7.5 Control Input ...................................................................................... 15
7.6 Pulse Output ..................................................................................... 17
8.Operating and Menu Structure ................................................................... 18
8.1 Overall ............................................................................................... 18
8.2 Measuring Mode ................................................................................ 18
8.3 Menu Mode ....................................................................................... 19
9.Instrument Parameters ............................................................................... 21
9.1 End of instrument parameterization ................................................... 21
9.2 Overview of menu functions/ instrument parameters ........................ 22
9.3 Signal ................................................................................................ 24
9.4 Scaling .............................................................................................. 25
9.5 Rate ................................................................................................... 27
9.6 Counter ............................................................................................. 28
9.7 Pulse output (only with ZOE-ZE Supply option 3) ............................. 29
9.8 User service ...................................................................................... 30
9.9 Factory service .................................................................................. 30
9.10Information ........................................................................................ 30
10.Technical Details ........................................................................................ 31
11.Order Details .............................................................................................. 32
12.Dimensions ................................................................................................. 33
13.EU Declaration of Conformance ................................................................. 34
Manufactured and sold by:
Kobold Messring GmbH
Nordring 22-24
D-65719 Hofheim
Tel.: +49(0)6192-2990
Fax: +49(0)6192-23398
E-Mail: info.de@kobold.com
Internet: www.kobold.com
ZOE
ZOE K04/0718 Page 3
2. Note
Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents.
When used in machines, the measuring unit should be used only when the machines fulfil the EC-machine guidelines.
2.1 Notice according to the Battery Law
Old batteries do not belong in household waste. You can send the batteries back to us or an authorized address, free of charge. As consumer, you are legally obliged to return the used batteries. Contaminated batteries are provided with a mark consisting of a crossed-out trash and the chemical symbol (Cd, Hg, Li or Pb) of heavy metal for classification as respective contaminant:
Cd1 Hg2 Pb3 Li4
1. "Cd" stands for cadmium.
2. "Hg" stands for mercury.
3. "Pb" stands for lead.
4. "Li" stands for lithium.
Page 4 ZOE K04/0718
3. Instrument Inspection
Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / delivery agent immediately, since they are responsible for damages during transit.
Scope of delivery:
The standard delivery includes:
Flow counter/- unit/-- in plastic- universal housing with wall or pipe mounting set
Model: ZOE-ZX with universal housing ‘K’ OR Oval gear flow meter DON- with electronics option –ZE/ZB in compact version Model: ZOE-ZX with universal housing ‘M’
Operating Manual Battery 3.6 V Lithium size AA for battery mode
4. Regulation Use
The electronic units ZOE-ZX are specifically designed for the calculation, display and transfer of calculations and flow rates of flow meters with pulse or frequency outputs. The instruments display flow rate, day counter (resettable) and total counter in the operator-selected units. A menu guides you through the programming of the device that largely eliminates the requirement of constant usage of operating manual. All user-specific program settings are retained even when changing the battery. A trouble-free operation of the device is only guaranteed if all instructions in this manual are complied. We do not accept any liability for damage caused by failure to follow these instructions.
5. Environment
The electronic options ZOE-ZX are weather resistant and adequately reflect IP66/67 (NEMA 4X). The electronics are housed in a UV-resistant, glass-filled nylon housing with stainless steel screws and FPM seals. The instruments are suitable for harsh indoor or outdoor environments and comply with EU Directive 2014/30/EU (Electromagnetic Compatibility).
ZOE
ZOE K04/0718 Page 5
6. Instrument / Functions overview
Function ZOE-ZExxF3 ZOE-ZBxxFB
Dual counting function
x x
Supply voltage
DC-supply
x -
Battery operation
x x
Sensor supply (only with external supply)
8 V -
Electrical outputs (only with external supply)
Pulse output
x -
LCD Display
Selectable units
x
X
Decimal point
x
X
Accumulated totalizer
x
X
Resettable totalizer
x
X
Linearization
x
X
Rate display
x
X
Backlight
x -
Page 6 ZOE K04/0718
7. Electrical connections
7.1 Cable entry for housing option -K
Up to 3 cable entries (M20x1.5 or ½ "NPT) are available for electric connection in case of electronics with plastic housing. To use these cable inlets, the existing factory protection caps must be broken with a tool (e.g. screwdriver) and a suitable cable gland should be screwed in. The cable glands are not included in the delivery.
Eruption of cable inlets
ZOE
ZOE K04/0718 Page 7
Battery 3,6V 2200mAh
Size AA
+ -
ext BattService
7.2 Overview of Terminals ZOE-ZX with Supply option B and 3
Supply option B (only battery- either 1 x 3,6V or 2 x 1,5V)
Supply option 3 (with battery- either 1 x 3,6V or 2 x 1,5V and external supply)
Page 8 ZOE K04/0718
7.3 Power Supply
Depending on functionality and features, the electronics offer different possibilities for power supply:
Options ZOE-ZExxx3xx: Battery and ext. DC-Supply Options ZOE-ZBxxxBxx Battery operation
7.3.1 Storing the counter readings
The storage of meter readings is carried out after each measurement cycle in the internal FRAM. If the power is interrupted and re-applied, than the meter reading revert to the last saved values.
7.3.2 External DC-Supply
When electronic units are supplied with external DC voltage, all functions are available i.e. Pulse output, display backlight and sensor supply can be used as needed.
If the device is taken out of operation and not used for longer periods, the battery must be removed. Otherwise, the device is always supplied by the battery and remains active. As a result, the battery can get discharged.
7.3.3 Battery operation (ZOE-ZB with supply option B)
The option ZOE-ZX can also be powered by a battery. In battery mode, the device function scope is relatively limited:
Pulse output is not available. The backlight of the display is switched off and cannot be turned on. Only passive sensors may be used like reed switches, as they require no
additional power supply. Usage of induction coils reduces the battery life. Other sensors, which require a sensor power for operation, are also not suitable for battery operation.
The supplied battery type 3.6 V AA Lithium (2200 mAh) should be inserted in the battery holder on the back side of the electronic (correct polarity is important!).
The following type of battery is required as a replacement for the supplied battery:
3.6 V lithium, size AA, capacity at least 2200 mAh, IEC type CR14505 For example: EVE type ER14505M, SAFT LS14500, Emmerich ER 14505, VARTA CR 14505
Battery life duration: The achievable battery life is dependent on various factors:
On the total number of detected input pulses and the input frequency(higher
frequencies reduce the battery life) On the environmental conditions - low temperatures reduce the usable battery capacity.
ZOE
ZOE K04/0718 Page 9
7.4 Sensor Inputs
7.4.1 Active pulse signal
Power Supply: External DC-Supply Signal input setting: „ACTIVE SIGNAL“
Wiring for ZOE-ZE with Supply option 3:
Wiring for ZOE-Z with Supply option B:
+ -
Battery 1,5V Size AA
+
-
Battery 1,5V Size AA
Page 10 ZOE K04/0718
7.4.2 Hall Sensor, NPN- and PNP-Sensors
Power supply: only external DC-supply Signal input setting: „HALL“ Signal input setting: „NPN“ Signal input setting: „PNP“
Wiring for ZOE-ZE:
ZOE
ZOE K04/0718 Page 11
7.4.3 Reed switch
Signal input setting: „REED “
Wiring for ZOE-ZE with Supply option 3:
Wiring for ZOE-Z with Supply option B: