Kobold VKP Operating Manual

Operating Instructions
for
Plastic
Flow Meter and Monitor
(viscosity compensated)
Model: VKP
VKP
1. Contents
1.Contents ........................................................................................................ 2
2.Note .............................................................................................................. 3
3.Suggested Application .................................................................................. 3
4.Operating Principle ........................................................................................ 4
5.Instrument Inspection .................................................................................... 4
6.Mechanical Connection ................................................................................. 5
7.Electrical Connection .................................................................................... 5
8.Commissioning .............................................................................................. 6
9.Technical Information .................................................................................... 7
10.Order Codes ................................................................................................. 8
11.Maintenance ................................................................................................. 8
12.Dimensions ................................................................................................... 9
13.Recommended Spare-parts .......................................................................... 9
14.EU Declaration of Conformance .................................................................. 10
Manufactured and sold by:
Kobold Messring GmbH
Nordring 22-24
D-65719 Hofheim
Tel.: +49(0)6192-2990
Fax: +49(0)6192-23398
E-Mail: info.de@kobold.com
Internet: www.kobold.com
VKP
2. Note
Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations apply­ing to Health & Safety and prevention of accidents.
When used in machines, the measuring unit should be used only when the machines fulfil the EC-machine guidelines.
as per PED 2014/68/EU
In acc. with Article 4 Paragraph (3), "Sound Engineering Practice", of the PED 2014/68/EU no CE mark. Diagram 8, Pipe, Group 1 dangerous fluids
3. Suggested Application
These units of type VKP are employed for flow measurement and monitoring of H20 and viscous liquids in an economical way. Only such liquids can be measured which are doped with impurities to a small extent, and can withstand against the material used for fabrication of housing. Significant errors in measurement may result if these devices are used for the measurement of high-viscous media. Large-size impurity-particles may lead to blockage of float element and thus are subjected to measurement-errors and error-indications. The same problem may arise if ferrite particles deposit on float element (with magnets).
These units are configured as follows:
Flow Measurement
The flow reading of the current value of flow is displayed on the scale sticked on the housing. The upper edge of the float indicates the flow value.
Limit-value contacts (Option)
For the monitoring of the flow value the flowmeter can be equipped with an adjustable limit switch.
N.O. function (increasing flow) or N.C. function (increasing flow) This contact is adjustable over the complete measuring range.