Kobold VKM Specifications

Viscosity-Compensated Flow
Meters and Switches
for Viscous Liquids
measuring
monitoring
analyzing
VKM
± 4% Full Scale Accuracy
Viscosity Compensation up
to ∆v=540 cSt
Density Compensation up to
∆p=30 lb/ft3
Universal Mounting
Max. Pressure 3600 PSI Brass
5000 PSI Stainless Steel
Housing Materials in Brass
or Stainless Steel
4...20 mA Output and/or
Digital Display Options
KOBOLD companies worldwide:
ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECH REPUBLIC, EGYPT, FRANCE, GERMANY, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, REPUBLIC OF KOREA, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, UNITED KINGDOM, USA, VIETNAM
01/03-11-2019
KOBOLD Instruments, Inc. 1801 Parkway View Drive Pittsburgh, PA 15205
Main Ofce:
1.800.998.1020
1.412.788.4890 info@koboldusa.com www.koboldusa.com
Viscosity Compensated Flowmeter and Switch Model VKM
Description
KOBOLD VKM flowmeters and switches are unique offerings for high viscosity media. Using KOBOLD’s patented viscosity compensation system, the VKM is insensitive to viscosity and density changes during operation. This patented and exceptional technology offers an extremely versatile instrument ready for almost any application imaginable.
Specifications
Accuracy: ± 4% full scale (viscosity of 105 cSt) Viscosity Range: 1...540 cSt Viscosity-Compensated: Up to Δv=540 cSt with same scale, ± 5% additional variation Density-Compensated: Up to Δp=30 lb/ft3 with same scale, ± 5% additional variation Flow Media: e.g. clean mineral oil, water and other compatible liquids Mounting: Universal, without recalibration Measuring Principle: Float with orifice, spring-loaded Max. Temperature: 212 °F (176 °F for VKM-0xxx & VKM- 6xxx w/C34P) Max. Pressure: 3600 PSIG for Brass units 5000 PSIG for SS units Housing: Nickel-plated Brass or SS 304 Fittings: Nickel-plated Brass or SS 304 Float: Brass or SS 304 Orifice: SS 301 Spring: SS 301 Seals: NBR (Brass units), FKM (SS units) Electr. Switch Housing: Plastic
Magnetic Pointer Indicator: Nickel-plated Brass, Polycarbonate Ingress Protection: IP54 for Side Indicator IP65 for Electrical Contact Contacts: Max. 230 VDC/0.26A/60W, 60 VDC/1A/60W, Max. 240 VAC/0.42A/100W, 100 VAC/1A/100W
Compact Electronic Option C34P** Power Requirement: 24 VDC ±20% Display: 3 digit LED Output: 4-20 mA, 3-wire, RLoop < 500 ohms Switch: PNP, 300 mA Max. Electrical Connection: M-12 Micro-DC plug, 4-Pin Hysteresis: Approx. 3.5 mm Float Movement Protection: IP65
**Note: Max flow range indicated is reduced by 10% for all ranges when using model VKM-0xxx series or the optional ..C34P electronic.
Order Details (Example: VKM-7112 U with order note; flow direction horizontal, left to right)
Range
Oil**
(GPM)
0.03...0.12 1/4" 11.6 VKM-0102 VKM-0202 VKM-5102 VKM-5202 VKM-6102 VKM-6202 VKM-7102 VKM-7202 -
0.05...0.3 1/4" 16.0 VKM-0103 VKM-0203 VKM-5103 VKM-5203 VKM-6103 VKM-6203 VKM-7103 VKM-7203 1/2"
0.15...0.5 1/4" 17.4 VKM-0104 VKM-0204 VKM-5104 VKM-5204 VKM-6104 VKM-6204 VKM-7104 VKM-7204 1/2"
0.2...0.9 1/4" 13.1 VKM-0105 VKM-0205 VKM-5105 VKM-5205 VKM-6105 VKM-6205 VKM-7105 VKM-7205 1/2"
0.5...2.5 1/4" 11.6 VKM-0106 VKM-0206 VKM-5106 VKM-5206 VKM-6106 VKM-6206 VKM-7106 VKM-7206 1/2"
1.0...3.5 1/2" 16.0 VKM-0107 VKM-0207 VKM-5107 VKM-5207 VKM-6107 VKM-6207 VKM-7107 VKM-7207 3/4"
1.5...5.0 1/2" 16.0 VKM-0108 VKM-0208 VKM-5108 VKM-5208 VKM-6108 VKM-6208 VKM-7108 VKM-7208 3/4"
1.0...11 3/4" 5.8 VKM-0109 VKM-0209 VKM-5109 VKM-5209 VKM-6109 VKM-6209 VKM-7109 VKM-7209 1"
1.0...14 3/4" 16.0 VKM-0110 VKM-0210 VKM-5110 VKM-5210 VKM-6110 VKM-6210 VKM-7110 VKM-7210 1"
2.0...18 3/4" 16.0 VKM-0111 VKM-0211 VKM-5111 VKM-5211 VKM-6111 VKM-6211 VKM-7111 VKM-7211 1"
2.0...20 1" 16.0 VKM-0112 VKM-0212 VKM-5112 VKM-5212 VKM-6112 VKM-6212 VKM-7112 VKM-7212 -
Accessory: P/N 807.007 = mating 5-Pin Micro-DC Plug w/ 6 Ft. Cable for Option C34P
Stand.
Conn.
(NPT)
Press.
Drop Max.
(PSI)
4-20 mA Transmitter
Oil Scale**
Brass SS Brass SS Brass SS Brass SS
Flow Switch
1 N/O Contact, Oil
Scale
Flowmeter
Oil Scale
*Max flow range indicated is reduced by 10% for all ranges when using model VKM-0xxx series or the optional ..C34P electronic **Option "R" is not available with option "V".
Note: Remember to always state your flow direction on your order
2
www.koboldusa.com
Flowmeter and Scale
1 N/O Contact, Oil
Scale
subject to change without prior notice.
Options
Opt.Conn.
(NPT)
Suffix "B"
No responsibility taken for errors;
Special
Contact
..C34P* = Compact
Electronic Display,for VKM-6xxx Series Only
..R** = Additional
Contact
..U = SPDT
Contact
..V = Special
Inlet Fitting for BVB Manifold Mount