Kobold SEN-96 Specifications

Pressure Sensor with
Ceramic Sensing Element
measuring
monitoring
analyzing
SEN-9601
Measuring Range:
-14.5... 0 PSIG to 0 ... 6000 PSIG
Max. Media Temperature: 185 °F
Accuracy: ± 0.5% / ± 0.75%
Output: Voltage or Current
Connection: 1/4" NPT, 1/2" NPT,
G 1/4, or G 1/2
OEM Targeted Product
KOBOLD companies worldwide:
ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECH REPUBLIC, EGYPT, FRANCE, GERMANY, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, REPUBLIC OF KOREA, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, UNITED KINGDOM, USA, VIETNAM
1/04- 2017
Main Ofce:
1.412.788.2830
1.412.788.4890 info@koboldusa.com www.koboldusa.com
FF
Pressure Sensor Model SEN-9601
Description
The KOBOLD SEN-9601 model is an electronic pressure transmitter with a ceramic sensor commonly used for air, industrial & technical gases, water, and oil. It is designed to be installed in gas distribution plants, on bottles, on refrigerators, on compressors, on vacuum pumps, in hydraulics, and in high pressure water plants. It is ideally suited to be used for general industrial applications, gas stocking, machine production, light or heavy pneumatics industry, the refrigeration industry, or in welding & vacuum applications.
Technical Data
Ranges Standard: -30...0" HG to 0...6000 PSIG Compound: -30" Hg/15 PSIG to -30" HG/150 PSIG Accuracy: ≤ ± 0.5% of Full Scale1) for all Ranges, Except Range "P025" (at ≤ ± 0.75% of Full Scale1)) Linearity (BFSL): ≤ ± 0.25 % of Full Scale for all Ranges, Except Range "P025" (at ≤ ± 0.5% of Full Scale) Repeatability: ≤ 0.1 % of the Full Scale, According to
EN 61298-2 Output Signal
Deviation of Zero: ≤ ± 0.5 % of Span, Typical; ≤ ± 0.75 % of Span, Max.
Thermal Drift: Between 32 °F and 176 °F; 1 % of Span,
2.5 % of Span, Max.
3)
Long Term Drift: ≤ 0.1% of Span, According to EN 61298-2
Temperature Process Media: -13...212 °F
Ambient: -13...185 °F Storage: -22...185 °F Output Signals: 4... 20 mA, 0...5 VDC, 0...10 VDC,
1... 5 VDC, 0.5... 4.5 Ratiometric
V
DC
Response Time: <4 ms Emission/Immunity: According to EN 61326, (Group 1-
Class B; Industrial Applications)
Process Connection: 316L, Hole ø 2.5 mm Sensor: Ceramic in Al2O3 Case: 316L, Vented up to 200 PSIG Gasket (Sensor): FKM Electric Connection: DIN 43 650A w/Cable Gland (Standard)
DIN 43 650A w/1/2" Conduit (Optional) Protection Degree: IP 65 According to IEC 529 /
EN 60529
2)
Weight: 0.27 lb
1)
Including linearity, hysteresis, repeatability, and output signal deviation of zero at the reference conditions described in standard EN 61298-1
2)
With properly assembled electric connection
3)
± 0.5% of Span for Range "P025"
Ranges Overpressure
-30...150 inHg/PSIG 290 PSIG
-30...100 inHg/PSIG 174 PSIG
-30...60 inHg/PSIG 116 PSIG
-30...30 inHg/PSIG 72.5 PSIG
-30...15 inHg/PSIG 72.5 PSIG
-30...0 inHg 72.5 PSIG
0...15 PSIG 72.5 PSIG
0...30 PSIG 72.5 PSIG
0 ... 60 PSIG 116 PSIG 0 ... 100 PSIG 174 PSIG 0 ... 150 PSIG 290 PSIG 0 ... 200 PSIG 464 PSIG 0 ...300 PSIG 580 PSIG 0 ... 500 PSIG 1160 PSIG 0 ... 600 PSIG 1160 PSIG 0 ... 1000 PSIG 1740 PSIG 0 ... 1500 PSIG 2900 PSIG 0 ... 2000 PSIG 4640 PSIG 0 ... 3000 PSIG 7250 PSIG 0 ... 4000 PSIG 7250 PSIG 0 ... 5000 PSIG 8700 PSIG
0 ... 6000 PSIG 8700 PSIG
Other ranges available upon request.
Dimensions
1.65"
40
1.57"
L
DIN 3852-E EN 837
..A.. = G ½, male EN 837 0.79" ..B.. = G ¼, male EN 837 0.51" ..E.. = G ¼, male DIN 3852-E 0.51" ..F.. = ½ - 14 NPT 0.79" ..G.. = ¼ - 18 NPT 0.51"
1)
Torque 20...30 Nm
34
1.34"
42
27
1)
F
39
1.54"
L
27
L
2
www.koboldusa.com
No responsibility taken for errors;
subject to change without prior notice.
Loading...
+ 1 hidden pages