Digital Pressure Transmitter
measuring
•
monitoring
•
analyzing
PDA
PDA-15
PDA-25
PDA-35
•• Measuring Range: -30...0" Hg to 0...5800 PSI
or -1...0 bar to 0...400 bar
•• Max. Temperature: 176 °F
•• Accuracy: ± 0.5% of Full Scale (±1.0% of Full
Scale for Ranges ≤ 30 PSI)
•• Housing / Fitting Material: Stainless Steel
•• Connection: ¼" NPT, ½" NPT, G ¼, or G ½
KOBOLD companies worldwide:
ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA,
CZECH REPUBLIC, EGYPT, FRANCE, GERMANY, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA,
MEXICO, NETHERLANDS, PERU, POLAND, REPUBLIC OF KOREA, ROMANIA, SINGAPORE, SPAIN,
SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, UNITED KINGDOM, USA, VIETNAM
03/01- 2017
KOBOLD Instruments, Inc.
1801 Parkway View Drive
Pittsburgh, PA 15205
Main Ofce:
1.800.998.1020
1.412.788.4890
info@koboldusa.com
www.koboldusa.com
Digital Pressure Transmitter Model PDA
Description
The KOBOLD pressure sensor, model PDA, is a cost
effective electronic pressure transmitter with digital indication
of actual pressure. An analog output of 0(4)-20 mA is available
for remote transmission of the measured value. A switch
output is also available. A piezoresistive sensor is used and
the PDA offers high switching accuracy. Long term stability,
repeatability, and a compact, rugged design makes the PDA
an ideal sensor for use in many OEM applications. Common
applications include: compressor monitoring, installations in
the machinery industry, and pumps.
Dimensions (mm)
Ø 44,5
39,7
/2)
1
/2 NPT)
1
107.6 (for ½ NPT)
114,6 (bei G
114.6 (for G½)
107,6 (bei
M4*
1
G
/2
1
/2 NPT
*No Nipple on NPT Thread
(¼" male connection available as option)
* Nippel entfällt bei NPT-Gewinde
(Abmessungen G
6*
SW 24
Ø 32
1
/4 auf Anfrage)
approx. 48
)
/2
1
(G
26
5*
ca.48
NPT)
/2
1
(
19
23,7
)
/2
NPT)
1
/2
(G
1
(
33,6
26,6
Order Details (Example: PDA-15 3 N2 P065)
Technical Details
Housing: 303 Stainless Steel
Process Connection: ¼" or ½" NPT
316 L Stainless Steel
Option G ¼ or G ½ Male
(Others on Request)
Gasket: FKM (Option: EPDM)
Sensor Element: Piezoresistive Ceramic Cell
Indication: 3-digit LED, Height 7 mm
Resolution: Max. 0.2 PSI (Depending on
Measuring Range and Measured
Value)
Max. Media Temp.: -4 ... 176 °F
Max. Ambient Temp.: -4 ... 176 °F
Max. Over Pressure: Up to 870 PSI: 3x
From 1450 PSI: 2x the Range
5800 PSI: 1.5x the Range
Supply Voltage: 24 VDC ± 20 %
Power Consumption: Approx. 100 mA
(without Switching Output)
Electrical Connection: M12x1 Plug
Standard Settings: Programmable via 3 Buttons
(Switching Point, Hysteresis, 0-20
mA or 4-20 mA, Start Point / End
Point (Current), Filter, Zero (Tare),
Security Code)
Over/Under Range: On LED Display
Load: Max. 500 Ω
Switching Option: 1x PNP or NPN Semiconductor,
Max. 300 mA,
Short-circuit Proof
Contact: N/O or N/C, Programmable
Output Indicator: 1 LED
ON/OFF-switch. Delay: 0.5 ... 99.5 s (Separately Adjustable)
Response Time: 0.5 s
Accuracy: ± 0.5 % of f. s. (± 1.0 % of f. s.
for Measuring Range: ≤ 30 PSI)
Protection: IP 65
Model Output
..15.. = Standard 0(4)-20 mA
PDA-
..25.. = 0(4)-20 mA, PNP Switch Output
..3.. = Plug M12x1
..35.. = 0(4)-20 mA, NPN Switch Output
Accessory: Mating Electrical Cable
Description Item #
M12 Micro-DC, 4-pin 6 foot Cable 807.037
M12 Micro-DC, 4-pin 16 foot Cable 807.037/5M
2
Electrical
Connection
www.koboldusa.com
Process
Connection
..N2.. = ¼" NPT
..N4.. = ½" NPT
..R2.. = G ¼
..R4.. = G ½
Measuring Range
(barG)
..C315 = -1...0
..B025 = 0...1
..B035 = 0...1.6
..B045 = 0...2.5
..B055 = 0...4
..B065 = 0...6
..B075 = 0...10
..B085 = 0...16
..A095 = 0...25
..A105 = 0...40
..A115 = 0...60
..A125 = 0...100
..A135 = 0...160
..A145 = 0...250
..A155 = 0...400
*Please specify custom range as a note on your order
subject to change without prior notice.
Measuring Range
(PSIG)
..H315 = -30...0 in. Hg
..P025 = 0...15
..P045 = 0...30
..P055 = 0...50
..P065 = 0...100
..P075 = 0...150
..P085 = 0...200
..P095 = 0...350
..P105 = 0...600
..P115 = 0...1000
..P125 = 0...1450
..P135 = 0...2300
..P145 = 0...3600
..P155 = 0...5800
..E = Custom*
No responsibility taken for errors;