Kobold NEK Operating Manual

Page 1
Operating Instructions
for
Conductive Level Switches
Model: NEK-...
Page 2
NEK
1.Contents ........................................................................................................ 2
2.Note .............................................................................................................. 3
3.Instrument Inspection .................................................................................... 3
4.Regulation Use .............................................................................................. 3
5.Operating Principle ........................................................................................ 4
6.Mechanical Connection ................................................................................. 4
6.1.Check service conditions: .................................................................... 4
6.2.Installation ............................................................................................ 4
7.Electrical Connection .................................................................................... 4
7.1.General ................................................................................................ 4
7.2.NPN switching output (NEK-1) ............................................................. 5
7.3.PNP switching output (NEK-2) ............................................................. 5
7.4.Relay switching output (NEK-3) ........................................................... 5
8.Commissioning .............................................................................................. 5
9.Maintenance ................................................................................................. 6
10.Technical Information .................................................................................... 6
11.Order Codes ................................................................................................. 7
12.Dimensions ................................................................................................... 7
13.EU Declaration of Conformance .................................................................... 8
Manufactured and sold by:
Kobold Messring GmbH
Nordring 22-24
D-65719 Hofheim
Tel.: +49(0)6192-2990
Fax: +49(0)6192-23398
E-Mail: info.de@kobold.com
Internet: www.kobold.com
Seite 2 NEK K05/0516
Page 3
NEK
2. Note
Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents.
When used in machines, the measuring unit should be used only when the machines fulfil the EC-machine guidelines.
3. Instrument Inspection
Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / forwarding agent immediately, since they are responsible for damages during transit.
Scope of delivery:
The standard delivery includes:
Conductive Level Switch Model: NEK-... Operating Instructions
4. Regulation Use
Any use of the Conductive Level Switch, model: NEK, which exceeds the manufacturer’s specification, may invalidate its warranty. Therefore any resulting damage is not the responsibility of the manufacturer. The user assumes all risk for such usage.
NEK K05/0516 Seite 3
Page 4
NEK
5. Operating Principle
The Kobold Level Switch of model NEK is a complete functional unit which is specially designed for monitoring conductive liquids under extreme conditions. Due to the design without any moving or protruding parts, the switches are very suitable for monitoring critical media with, for example, solid content, negligible density or high viscosity. The double-thread allows a variety of installations. The length of the shaft can be extended by attaching an additional protective tube. The instruments operate on the conductive principle of measurement. The conductive medium touches both electrodes causing a negligible alternating current to flow; the output state changes.
6. Mechanical Connection
6.1. Check service conditions:
Chemical resistance of materials Maximum operating pressures Maximum service temperature
6.2. Installation
Tank installation may be the side or from the top (universal) Avoid pressure and tensile/torsional stress Check connections for leakage
7. Electrical Connection
7.1. General
Important! Make sure that the voltages in your plant correspond with the Level Switch voltages
Make sure that the supply wires are de-energized. Wire the connection cable to your supply according to the terminal connection
diagrams below.
Seite 4 NEK K05/0516
Page 5
NEK
/
C
Attention! Incorrect wiring will lead to damage of the unit’s electronics.
If the unit is installed in a metallic, conductive container, this container must be connected with the NEK supply potential GND, otherwise it may cause functional problems by potential differences.
7.2. NPN switching output (NEK-1)
braun
brown : 18-29 V D
schwarz/black : NPN O.C. max.300 mA
NPN
blau/blue :GND
7.3. PNP switching output (NEK-2)
PNP
7.4. Relay switching output (NEK-3)
NO
Relay
NC
8. Commissioning
braun/brown : 18-29 V DC
schwarz/black : PNP O.C. max.300 mA blau/blue : GND
braun/brown : 18-29 V DC grau/grey : Relay out n.o. weiß/white : Relay out n.c.
schwarz/black : Relay out common
blau/blue :GND
The measuring instruments are pre-set and are ready for operation after electrical connection. The LED signals the switch state of the level switch.
LED off: no power supply LED off with short "ON pulses":
Power supply on / switch state de-activated (dry)
LED on: Power supply on / switch state activated (wet)
NEK K05/0516 Seite 5
Page 6
NEK
9. Maintenance
The Conductive Level Switch is maintenance-free. Should the electrodes be contaminated with a non-conductive coating (oil, grease, etc.), they can be cleaned with a suitable tool (e.g. cloth). Do not use a cleaner that would damage the plastic housing.
10. T echnical Information
Case: PPS (Rhyton) or polypropylene Electrodes: stainless steel 1.4571 Connections: R 3/4 or 3/4 NPT male thread Operating temperature: -25 to +85 °C (PPS)
-25 to +60 °C (polypropylene) Max. pressure: 20 bar (PPS) 6 bar (polypropylene) Installation position: horizontal or vertical Contact components: open collector (NPN or PNP) wet signal Option: relay (floating changeover contact) Electrical connection: 2 m encapsulated cable 3-core screened (open collector) 5-core unshielded (relay) Supply: 18-29 VDC < 20 mA Switch-in delay: dry/wet: 0.5 sec. wet/dry: 0.5 sec. Sensitivity: approximately 50 k Min. Conductance: approximately 100 µS/cm Switch capacity: open collector: max. 32 V / max. 100 mA / short-circuit-proof Relay: max. 1 A / 30 V / short-circuit-proof Protection type: IP 68
Seite 6 NEK K05/0516
Page 7
NEK
11. Order Codes
Example: NBK-1136 R20 C
12. Dimensions
NEK K05/0516 Seite 7
Page 8
NEK
13. EU Declaration of Conformance
We, KOBOLD-Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product:
Conductive level switch model: NEK -...
to which this declaration relates is in conformity with the standards noted below:
EN 61000-6-4:2011-09
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
EN 61000-6-2:2006-03
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments
EN 61010-1:2011-07
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements
EN 60529:2014-09
Degrees of protection provided by enclosures (IP Code)
Also the following EC guidelines are fulfilled:
2014/35/EU Low Voltage Directive 2011/65/EU RoHS (category 9)
Hofheim, 12. May 2016 H. Peters M. Wenzel General Manager Proxy Holder
Seite 8 NEK K05/0516