NEK
Pressure: max. 20 bar
Temperature: max. 85 °C
Connection:
R ¾ or ¾" NPT
Material:
PPS/stainless steel Polypropylene/stainless steel
2/02- 2014
KOBOLD companies worldwide:
ARGENTINA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLUMBIA, CZECHIA, DOMINICAN REPUBLIC, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDO­NESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE, SOUTH KOREA, SPAIN, SWITZER-LAND, TAIWAN, THAILAND, TUNISIA, USA, VIETNAM
KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts.
Head Of ce:
+49(0)6192 299-0
+49(0)6192 23398 info.de@kobold.com www.kobold.com
1
Conductive Level Switches Model NEK
Description
The KOBOLD level switch of model NEK is a complete functional unit which is specially designed for monitoring conductive liquids under extreme conditions. Due to the design without any moving or protruding parts, the switches are very suitable for monitoring critical media with, for example, solid content, negligible density or high viscosity. The double-thread allows a variety of installations. The lengthof the shaft can be extended by attaching an additional protective tube. The instruments operate on the conductive principle of measurement. The conductive medium touches both electrodes causing a negligible alternating current to fl ow; the output state changes.
Dimensions
Technical Details
Housing: PPS or Polypropylene
Electrodes: stainless steel 1.4571
Connections: R ¾ or ¾" NPT male thread
Operating temperature: -25 ... +85 °C (PPS)
-25 ... +60 °C (Polypropylene)
Max. pressure: 20 bar (PPS) 6 bar (Polypropylene)
Installation position: horizontal or vertical
Contact components: open collector (NPN or PNP) wet signal
Option: relay (fl oating changeover contact)
Electrical connection: 2 m encapsulated cable 3-core screened (open collector) 5-core unshielded (relay)
Supply: 18-29 V
, < 20 mA
DC
Switch-in delay: dry/wet: 0.5 s wet/dry: 0.5 s
Sensitivity: approx. 50 kΩ
Min. conductance: approx. 100 μS/cm
Switch capacity: Open Collector: max. 32 V / max. 100 mA short-circuit-proof
Relay: max. 1 A / 30 V short-circuit-proof
Protection: IP 68
Applications
 Chemical tanks
 Fresh-water tanks
 Mixing vessels
 Run-dry protection for pumps
Order Details (Example: NEK-1136 R20 C)
Immersion
length
36 mm
Relay (changeover contact) NEK-3136... NEK-3236...
73 mm
Relay (changeover contact) NEK-3173... NEK-3273...
2
Contact Model
Open collector (NPN) NEK-1136... NEK-1236...
Open collector (PNP) NEK-2136... NEK-2236...
Open collector (NPN) NEK-1173... NEK-1273... ...N20... = ¾ NPT
Open collector (PNP) NEK-2173... NEK-2273...
PPS Polypropylene
www.kobold.com
Mechanical connection
...R20... = R ¾
Electrical
connection
...C = 2 m PVC cable