Kobold NCW Series, NCW-N, NCW-T, NCW-H, NCW-S Operating Instructions Manual

Operating instructions
for
Capacitive Level Monitor
NCW
NCW
1. Content
1.Content ......................................................................................................... 2
2.Note .............................................................................................................. 3
3.Instruments Inspection .................................................................................. 3
4.Description .................................................................................................... 3
5.Regulation Use .............................................................................................. 3
6.Operating principle ........................................................................................ 4
7.Mechanical connection .................................................................................. 4
8.Electrical connection ..................................................................................... 5
9.Adjustment .................................................................................................... 6
10.Models .......................................................................................................... 9
11.Technical Data ............................................................................................ 10
12.EU Declaration of conformance .................................................................. 11
13.Notes ........................................................................................................... 12
Manufactured by:
9.1 Module replacement ............................................................................ 8
Kobold Mesura S.L.U
Avda Conflent Nº68 Nave 15
08915 Badalona Tel.: +34 93 460 38 83 Fax: +34 93 460 38 76
E-Mail: info.es@kobold.com
Internet: www.kobold.com
Edition: May 2017
NCW
2. Note
Please read these operating instructions before unpacking and putting the unit in operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents.
3. Instruments Inspection
Instruments are inspected before shipping and sent out in perfect condition. Scope of delivery The standard delivery includes:
Capacitive Level Monitor NCW Cable gland M20 Operating Instructions
4. Description
All NCW level switch instruments can be used in any application where one level of liquid in a tank or a silo must be detected
5. Regulation Use
The capacitive Level Monitor is indicated to punctual level detection in tanks containing liquids.
The are 4 basic models:
NCW-N: Rigid probe in PTFE, for general applications in metallic tanks. NCW-T: Rigid probe in PTFE with stainless steel tube (ground tube). For products
with a low dielectrical constant and non metallic tanks.
NCW-H: Rigid probe in PTFE with special thread made of stainless steel for high Temperatures (125ºC)
NCW-S: Double rigid probe in PVDF for NON METALLIC tanks containing aggressive liquids that attack stainless steel.
DT0453 Page 3
NCW
6. Operating principle
The NCW sensor together with the wall of the tank is a capacitor. The dielectric constant of this capacitor is the air when the product (media) doesn’t reach the sensor. When the product covers the sensor, the dielectric constant is the product one. The electronic circuit of the NCW detects this change and activates an output relay.
7. Mechanical connection
Before installation:
Remove all packing materials and transport retainers and ensure that no
such materials remain in the device.
Make sure that the permitted max. operational pressure and temperature
limits are not exceeded (see Technical Information)
Protect the measuring sensor from external damage. The units may not be installed at a location within an inductive field. If possible, check directly after mechanical installation whether the
connection thread to the pipe is fully sealed.
Installation: The NCW is installed using a 1”BSP, (2”BSP Thread in NCW-S version) Check if probe’s length is correct to detect the level. At the end of the probe there is a stopper to guaranty the electrode waterlight. This part (10mm aprox.) is not sensible to the liquid.