Kobold Model Specifications

Heavy Duty
Pressure Transmitter
measuring
monitoring
analyzing
PAS
Span: -14.5 … 21.7 PSIG up to 0…8700 PSIG
t
: 248 °F
max
Process Connection: ½" NPT, or
Various Diaphragm Seals on Request
Material: 316L Stainless Steel
Output: 4 ... 20 mA
Sensor Input: Gauge or Absolute Pressure
Self-Diagnostic Function: Sensor, Memory A/D
Converter, Power etc.
Digital Communication with HART
KOBOLD companies worldwide:
ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECH REPUBLIC, EGYPT, FRANCE, GERMANY, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, REPUBLIC OF KOREA, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, UNITED KINGDOM, USA, VIETNAM
01/12- 2016
®
Protocol
KOBOLD Instruments, Inc. 1801 Parkway View Drive Pittsburgh, PA 15205
Main Ofce:
1.412.788.2830
1.412.788.4890 info@koboldusa.com www.koboldusa.com
Heavy Duty Pressure Transmitter Model PAS
Description
The KOBOLD Pressure Transmitter model PAS is a microprocessor based high performance transmitter, which has a scalable pressure calibration and output signal. It automatically compensates for ambient temperature and process variables. Communication with the instrument and configuration of various parameters is possible via HART® protocol. All of the sensor's data is input, modified and stored via EEPROM.
Features
Superior Performance
●O High Reference Accuracy:
±0.075 % of Calibrated Span
●O Long-term Stability
●O High Rangeability (100 : 1)
Flexibility
●O Data configuration with HART
●O Measurement of gauge or absolute pressure
®
configurator
Reliability
●O Continuous self-diagnostic function
●O Automatic ambient temperature compensation
●O EEPROM write-protection
●O Fail-mode process function
Transmitter Description
Electronics Module
The Electronics module consists of a circuit board sealed in an enclosure. There is an MCU module, an analog module, an LCD module, and a terminal module within the transmitter. The MCU module acquires the digital value from the analog module and applies correction coefficients selected from EEPROM. The output section of the MCU module converts the digital signal to a 4…20 mA output. The MCU module communicates with the HART®-based configurator or control system, such as DCS (Distributed Control System). The power section of the MCU module has a DC-to-DC power conversion circuit and an input/output isolation circuit. The LCD module plugs into the MCU module and displays the digital output in a user configured unit.
Sensor Inputs
The pressure transmitter model PAS is available as a piezo­resistive pressure transmitter which measures gauge pressure as well as absolute pressure. The sensor module converts the resistance into a digital value. The MCU module calculates the process pressure based on this digital value.
Functional Block Diagram
Sensor Part
A/D-Conversion
EEPROM
Piezoelectric sensor
• Gauge pressure
• Absolute pressure
2
www.koboldusa.com
MCU Part
Microprocessor
· Input Sensor Value
· Engineering Units
· Re–range (Zero / Span)
· Zero Point Adjustment
· DA Trimming
· Damping / Filtering
·
LCD Engineering Mode
· Diagnostics
· Self Compensation
· Communications
· LCD Display
· Configuration Data
4~20mA
DAC
®
HART
HART® Protocol with Host
No responsibility taken for errors;
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
The sensor modules include the following features:
• The software of the transmitter compensates for thermal effects, improving performance.
• Precise Input Compensation during operation is achieved with temperature and pressure correction coefficients that are characterized over the range of the transmitter and stored in the sensor module's EEPROM memory.
• EEPROM stores sensor information and correction coefficients separately from the MCU module, allowing for easy repair, reconfiguration and replacement.
Basic Setups
The following settings can be easily configured from any host that can support HART® protocol:
• Operational parameters
• 4 … 20 mA (zero points/span)
• Engineering units
• Damping time: 0.25…60 sec.
• Tag: 8 alphanumeric characters
• Descriptor: 16 characters
• Message: 32 characters
• Date: day/month/year
Calibration and Adjustment
• Lower/Upper range (zero/span)
• Sensor zero adjustment
• Zero point adjustment
• DAC output adjustment
• Transfer function
• Self-compensation
Self-Diagnostics and Others
• CPU & Analog Module Fault Detection
• Communication error
• Fail-mode handling
• LCD indication
• Temperature measurement of sensor module
Process Connection via Diaphragm Seals
For connecting the model PAS to different process connections, diverse diaphragm seal versions are necessary. They can be connected to the pressure transmitter directly or via a capillary tube. Depending on the application; different combinations of diaphragm seals, capillary tubes and fill fluids are possible. To clarify those possibilities, the special connections via diaphragm seals should be requested separately from the pressure transmitter.
No responsibility taken for errors; subject to change without prior notice.
www.koboldusa.com
3
Heavy Duty Pressure Transmitter Model PAS
Technical Details
Measuring Principle: Piezoresistive Sensor Measuring Span: -14.5…21.7 PSIG up to 0…8700
(Depending on instrument version), zero and span values can be set anywhere within the range limits. Span must be greater than or equal to the minimum span.
Accuracy: 0.075 % of calibrated span Process Temperature: -40...248 °F
(Approval codes may effect limits. Max. ambient temperature at LCD = 176 °F.)
Ambient Temperature: -22…176 °F Storage Temperature: -40…185 °F
(Non-condensing)
Humidity Limit: 5 %...98 % RH
Pressure Limits (with Silicone Oil)
(Valid for stand-alone unit only, without assembled diaphragm seals.)
Model G -14.5...43.5 PSIG (for Range 3)
-14.5...435 PSIG (for Range 4)
0...1552.5 PSIG (for Range 5)
0...5800 PSIG (for Range 6)
0...10875 PSIG (for Range 7)
Model A 0...72.5 PSIG (for Range 4)
0...435 PSIG (for Range 5)
0...754 PSIG (for Range 6)
Maximum Load: 250 Ω at 17.5 V
550 Ω at 24 V
Max. loop resistance =
DC
DC
(U - 12 VDC)
0.022 A
Electrical Connection: ½" NPT conduit with M4
screw terminals, G ½ conduit with M4 screw terminals
Output: Two wire 4…20 mA, user-configurable for linear output, digital process value superimposed on 4…20 mA signal, available to any host that conforms to the HART® protocol
Update Time: 0.12 seconds Turn-On Time: 3 seconds Protection: IP 67 for standard (code S) Weight: 3.8 lbs (excluding options)
6.3 lbs (st. steel housing option) Failure Mode: Fail high: current ≥ 21.1 mA
Fail low: current ≤ 3.78 mA
EMC Conformity Standards: EMI (emission) - EN 50081-2:1993
EMS (immunity) - EN 50082-2:1995
ATEX Approval (Option): II 2G Exd IIC T6...T4
Wetted Materials Isolating Diaphragms: 316L Stainless Steel
Connection Thread: 316 Stainless Steel
Non-wetted Materials Fill Fluid: Silicone oil
Electronics Housing: Aluminum, flameproof (Ex d) and waterproof (lP 67), 316 L SS (option)
Cover O-ring: NBR Paint: Epoxy-polyester or polyurethane Mounting Bracket: 2-inch pipe, 304 SS, painted
carbon steel with 304 SS U-bolt
Nameplate: 304 Stainless steel
Process Connections: ½" NPT female Mounting Position: Upright Display: 5 Digit LCD Power Supply: 12 … 45 VDC -operation
17.5 … 45 VDC -HART®
communications
Technical Data for Version with 50 mm Extended Diaphragm
(Model PAS-P, Engineered for the Paper/Pulp Industry)
Application: Level and gauge pressure measurement
Accuracy: ± 0.2% of calibrated span @ 68 °F
Long Term Stability: Application dependent, typically
± 0.125% of URL / 1 year
Process Temperature: 68...95 °F
Ambient Temperature: 68...95 °F
Materials:
O-ring: FKM
Extended Sleeve: 304 Stainless Steel
Process Connection: 316-Ti / 316 Stainless Steel
Other Specifications: Same as standard models
No responsibility taken for errors;
4
www.koboldusa.com
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
Order Details (Example: PAS- G EE 3 S 4 N S0 0):
Model Version
..G.. = Gauge Pressure
PAS-
..A.. = Absolute Pressure
..EE.. = 316L st. st. / 316 st. steel
Order Details Continued:
Material
Diaphragm/Other
Measuring Range Measuring Span
for PAS-G
..3.. = -14.5...21.7 PSIG
..4.. = -14.5...217 PSIG
..5.. = 0...725 PSIG
..6.. = 0...3625 PSIG
..7.. = 0...8700 PSIG
6 W.C....36.3 PSIG
60 W.C....232 PSIG
200 W.C....725 PSIG
36.3 PSIG...3625 PSIG
87 PSIG...8700 PSIG
for PAS-A
..4.. = 0...36 PSIA
..5.. = 0...217 PSIA
..6.. = 0...362 PSIA
10 W.C....36.3 PSIA
60 W.C....217 PSIA
100 W.C....362 PSIA
Fill Liquid
Process
Connection
Electrical
Connection
Approvals Options
..0 = without
..N.. = ½" NPT epoxy-
polyester painted aluminium
..S.. = silicone ..4.. = ½" NPT female
..G.. = G ½ epoxy-
polyester painted aluminium
1)
Diaphragm seal model and application data to be clearly specified. The application Index on page 17-18 must be completed.
For summary of diaphragm seal models and possible ranges, see page 9 onwards. For dimensional details see DRM data sheet.
..S0.. = standard
(waterproof IP 67)
..F0.. = ATEX, flameproof,
Ex d
..E = oil free finish
..M = housing in stainless steel
..N1) = mounting of PAS onto
diaphragm seal
Order Details Mounting Brackets:
Description Order Number
Angle type bracket for PAD/PAS vertical pipe mounting for PAS vertical pipe mounting for PAD incl. U-Clamp for 2“ pipe mounting bracket and 2 x mounting nuts/ washers incl. 4 x mounting screws for PAS incl. 4 x mounting screws for PAD
Flat type bracket for PAD/PAS horizontal pipe mounting for PAS vertical pipe mounting for PAD incl. U-Clamp for 2“ pipe mounting bracket and mounting nuts/ washers incl. 4 x mounting bolts and washers for PAS incl. 4 x mounting bolts for PAD
ZUB-PAD/PAS-K
ZUB-PAD/PAS-L
Order Details Manifold Valve:
Description Order Number
2-way Manifold Valve, Direct Mount, Machined
No responsibility taken for errors; subject to change without prior notice.
www.koboldusa.com
V-2003CDADABAA
5
Heavy Duty Pressure Transmitter Model PAS
Order Details for PAS-..P Extended Diaphragm Version for Paper/Pulp Industries (Example: PAS-P ES 3 S A N S 0 0)
Model
PAS-P..
..ES.. = 316 SS / 304 SS,
316L SS, 316-Ti SS
Material Measuring Ranges
Diaphragm/Other Code Measuring Range Measuring Span
..3.. -10,000 mm H2O...15,000 mm H2O 150 mm H2O...15,000 mm H2O
..4.. -10,000 mm H2O...150 m H2O 1,500 mm H2O...150 m H2O
Order Details Continued
Filling Liquid Process Connection Electrical Connection Approval Manifold Valve Options
..N.. = 1" Class 150 RF
..P.. = 1-1/4" Class 150 RF
..S.. = Silicone
..Q.. = 1-1/2" Class 150 RF
..R.. = 2" Class 150 RF
..S.. = 2-1/2" Class 150 RF
..T.. = 3" Class 150 RF
..U.. = 4" Class 150 RF
..V.. = 5" Class 150 RF
..W.. = 6" Class 150 RF
..N.. = 1/2" NPT epoxy-polyester
painted aluminum
..G.. = 1/2" epoxy-polyester painted aluminum
..S.. = without, standard, (waterproof IP 67)
..0.. = without ..0 = without
No responsibility taken for errors;
6
www.koboldusa.com
subject to change without prior notice.
Dimensions
86
LOCK
LOCK
FIELD
TERMINALS
s
73 39
112
160.5
-
N
E
I
V
I
L
S
O
P
A
M
T
O
E
X
R
E
H
E
S
P
AF 30
32.5
M6X1 DP9
4PLS
LOCK
LOCK
FIELD
TERMINALS
s
73 39
112
160.5
IN
Drain
IN
Drain
148
Ø
30
VENT.
IS
O
L
A
T
E
Standard Model
Heavy Duty Pressure Transmitter Model PAS
3.39"
I
T
O
U
N
A
-
C
-
I
D
E
Z
I
G
R
E
N
E
E
L
I
H
W
N
E
P
O
N
E
X
P
L
O
S
I
V
E
A
T
M
O
S
P
H
E
R
E
T
D
O
O
N
32.5
1.28"
4.41"
112
2.87" 1.54"
73 39
s
TERMINALS
LOCK
LOCK
FIELD
160.5
6.32"
AF 30
2-way Manifold Valve: (Direct Mount, Machined) V-2003CDADABAA (PTFE Packing)
(Inlet: ½" NPT Female / Outlet: ½" NPT Male)
Technical Details Material: AISI 316L Pressure Rating: 6 000 psi Temperature Range: -99...410 °F (PTFE Packing), Standard
-65... 950 °F (GRAPHOIL Packing), On Request Weight: 1.94 lbs
VENT.
Drain
IN
5.83"
148
Included Accessories: Plug
No responsibility taken for errors; subject to change without prior notice.
IS
O
A
L
E
T
30
1.18"
Ø
4.73"
120
OUT IN
Drain 1/4" NPT-F
with plug
www.koboldusa.com
7
Heavy Duty Pressure Transmitter Model PAS
Dimensions
Model: PAS-P with Extended Diaphragm 50 mm
10.43"
4.70"
H
Connection ASME B16.5 RF Class 150
Code inches D1 D2 D3 H
N 1 4.25" 3.12" 2.00" 0.56"
P 1-¼ 4.62" 3.50" 2.50" 0.62"
Q 1-½ 5.00" 3.88" 2.88" 0.69"
R 2 6.00" 4.75" 3.62" 0.75"
S 2-½ 7.00" 5.50" 4.12" 0.88"
T 3 7.50" 6.00" 5.00" 0.94"
U 4 9.00" 7.50" 6.19" 0.94"
V 5 10.00" 8.50" 7.31" 0.94"
W 6 11.00" 9.50" 8.50" 1.00"
1.97"
D3
D2
D1
No responsibility taken for errors;
8
www.koboldusa.com
subject to change without prior notice.
X
X
Heavy Duty Pressure Transmitter Model PAS
Example of PAS Directly Assembled with Diaphragm Seal
(for Dimensional Details, see DRM Datasheet)
X
3.39"
Fig. 1
Example of PAS Remotely Assembed with Diaphragm Seal and Capillary
(for Dimensional Details, see DRM Datasheet)
3.39"
X
4.41"
± Δh
Fig. 2
Dimensions: Examples for DN50 / DN 80 /DN100 / 2" ANSI / 3" ANSI/4"ANSI
(Table valid for Fig. 1 and Fig. 2)
Flange Type D k d
2
b f d
DN50 PN16 6.50" 4.92" 0.71" 0.71" 0.08" DN50 PN40 6.50" 4.92" 0.71" 0.79" 0.08" 0.16" 2" ANSI Cl. 150 6.00" 4.75" 0.75" 0.75" 0.08" 2" ANSI Cl. 300 6.50" 5.00" 0.75" 0.88" 0.08" 0.31" DN80 PN16 7.87" 6.30" 0.71" 0.79" 0.08" DN80 PN40 7.87" 6.30" 0.71" 0.94" 0.08" 0.31" 3" ANSI Cl. 150 7.50" 6.00" 0.75" 0.94" 0.06" 3" ANSI Cl. 300 8.25" 6.63" 0.87" 1.12" 0.06" 0.31"
4
4.02"
3.62"
5.43"
5.00"
X
0.16"
0.16"
0.31"
0.16"
DN100 PN16 8.66" 7.09" 0.71" 0.79" 0.08" 5.87" 0.31" DN100 PN40 9.25" 7.48" 0.87" 0.94" 0.08" 5.87" 0.31" 4" ANSI Cl. 150 9.00" 7.50" 0.75" 0.94" 0.06" 6.19" 0.31" 4" ANSI Cl. 300 10.00" 7.87" 0.87" 1.26" 0.06" 6.19" 0.31"
No responsibility taken for errors; subject to change without prior notice.
www.koboldusa.com
9
Heavy Duty Pressure Transmitter Model PAS
X
± Δh
Example of PAS Remotely Assembed with Extended Diaphragm Seal and Capillary
(for Dimensional Details, see DRM Datasheet)
3.39"
Fig. 3
Dimensions: Examples for DN50 / DN 80 /DN100 / 2" ANSI / 3" ANSI/4"ANSI
Flange Type D k d
2
b f d
DN50 PN16 6.50" 4.92" 0.71" 0.71" 0.08" DN50 PN40 6.50" 4.92" 0.71" 0.79" 0.08" 0.16" 1.89" 2" ANSI Cl. 150 6.00" 4.75" 0.75" 0.75" 0.08" 2" ANSI Cl. 300 6.50" 5.00" 0.75" 0.88" 0.08" 0.31" 1.89" DN80 PN16 7.87" 6.30" 0.71" 0.79" 0.08" DN80 PN40 7.87" 6.30" 0.71" 0.94" 0.08" 0.31" 2.99" 3" ANSI Cl. 150 7.50" 6.00" 0.75" 0.94" 0.06" 3" ANSI Cl. 300 8.25" 6.63" 0.87" 1.12" 0.06" 0.31" 2.99" DN100 PN16 8.66" 7.09" 0.71" 0.79" 0.08" 5.87" 0.31" 3.50" DN100 PN40 9.25" 7.48" 0.87" 0.94" 0.08" 5.87" 0.31" 3.50" 4" ANSI Cl. 150 9.00" 7.50" 0.75" 0.94" 0.06" 6.19" 0.31" 3.50" 4" ANSI Cl. 300 10.00" 7.87" 0.87" 1.26" 0.06" 6.19" 0.31" 3.50"
4
4.02"
3.62"
5.43"
5.00"
X d
0.16" 1.89"
0.16" 1.89"
0.31" 2.99"
0.16" 2.99"
5
R
L
50 mm (2")/ 100 mm (4")/ 150 mm (6")/ 200 mm (8")/
(customer
specified)
4.41"
No responsibility taken for errors;
10
www.koboldusa.com
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly)
(Standard device without additional options (e.g. coatings, special materials etc.). For dimensions/technical data, see DRM data sheet. Accuracy: 0.075% of calibrated span + influence of seal). Over and under ranges of the min./max. span may be possible, but must be verified by KOBOLD for each application. The indicated min./max. spans do not consider any coating of the diaphragm seals. For additional information contact KOBOLD.
Model DRM Size Code Size Note Ø Diaphragm
DRM-189
Max. Media
Temperature
Min. Span
(PSIG)
Max. Span
(PSIG)
DRM-600
DRM-601
F23 Ø 18
R15 G ½
R20 G ¾ Ø 23.8 0 ... 23.2* 14500
R25 G 1 Ø 29.5 0 ...14.5 8700
R32 G 1 ¼ Ø 38 0 ... 8.7 8700
R40 G 1 ½ Ø 40 0 ... 8.7 8700
N15 ½" NPT Ø 18
N20 ¾" NPT Ø 18
N25 1" NPT Ø 23.8 0 ... 23.2 8700
N32 1 ¼" NPT Ø 34.5 0 ... 14.5 8700
M20 M20 x 1.5 Ø 18 0 ... 58 8700
M48 M 48 x 3 Ø 40 0 ...8.7 8700
R15 G ½
R20 G ¾ Ø 23.8 0 ... 23.2* 14500
R25 G 1 Ø 29.5 0 ...14.5 8700
R32 G 1 ¼ Ø 38 0 ... 8.7 8700
R40 G 1 ½ Ø 40 0 ... 8.7 8700
N15 ½" NPT Ø 18
N20 ¾" NPT Ø 18
N25 1" NPT Ø 23.8 0 ... 23.2 8700
N32 1 ¼" NPT Ø 34.5 0 ... 14.5 8700
M20 M20 x 1,5 Ø 18 0 ... 58 8700
M48 M 48 x 3 Ø 40 0 ...8.7 8700
For homogenizing machines, direct
Fixed male thread, direct
Fixed male thread with capillary
Ø 18 248 °F 0 ... 58 14500
Ø 18
212 °F
Ø 18
392 °F
0 ... 58* 14500
0 ... 58*
0 ...58*
0 ... 58* 14500
0 ... 58*
0 ... 58*
14500
14500
14500
14500
DRM-602
DIN 11851
* Consult Factory for Minimum Span per Customer Application
No responsibility taken for errors; subject to change without prior notice.
R20 DN 20
R25 DN 25
R32 DN 32
R40 DN 40
R50 DN 50
R65 DN 65
R80 DN 80
R1H DN 100
Dairy connection, direct
Ø 18
Ø 23.8 0 ... 23.2
Ø 29.5 0 ...14.5
Ø 38 0 ... 8.7
Ø 45.5
Ø 64
Ø 64
Ø 64
www.koboldusa.com
212 °F
0 ...58
0 ... 5.8 362.5
0 ... 3.6 362.5
0 ... 3.6 362.5
0 ... 3.6 362.5
580
580
580
580
11
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly)
Model DRM Size Code Size Note Ø Diaphragm
DRM-603
DIN 11851
R20 DN 20
R25 DN 25
R32 DN 32
R40 DN 40
R50 DN 50
R65 DN 65
R80 DN 80
R1H DN 100
Dairy connection, capillary
Ø 18
Ø 23.8 0 ... 23.2
Ø 29.5 0 ... 14.5
Ø 38 0 ...8.7
Ø 45.5 0 ... 5.8
Ø 64
Ø 64
Ø 64
Max. Media
Temperature
392 °F
Min. Span
(PSIG)
0 ... 58
Max. Span
(PSIG)
580
580
580
580
362.5
0 ... 3.6 362.5
0 ... 3.6 362.5
0 ...3.6 362.5
DRM-604
IDF
DRM-605
IDF
DRM-606
DRM-607
DRM-607/1
R25 1"
R40 1 ½" Ø 42 0 ... 14.5 580
IDF socket with union nut, direct
Ø 29.5
0 ... 23.2 580
212 °F
R50 2" Ø 56 0 ... 8.7 580
R25 1"
R40 1 ½" Ø 42 0 ... 8.7 580
IDF socket with union nut, capillary
Ø 29.5
0 ... 14.5 580
392 °F
R50 2" Ø 56 0 ... 5.8 580
R20 G ¾
Capsule seal with rotable male, capillary
short capsule 662 °F
0 ... 87 8700
R28 M 28 x 1.5 0 ... 87 8700
R15 G ½
Capsule seal with fixed male, direct
long capsule
0 ... 14.5 8700
R20 G ¾ 0 ... 14.5 8700
212 °F
R15 G ¾
Capsule seal with fixed male, direct
long capsule
0 ... 14.5 8700
R20 G 1 0 ... 14.5 8700
12
DRM-608/1
DRM-610
SMS
R20 G ¾
Capsule seal with union nut, capillary
long capsule
0 ... 14.5 8700
662 °F
R25 G 1
R40 1 ½"
Capsule seal with union nut, capillary
SMS socket with union nut, direct
long capsule 0 ... 14.5 8700
Ø 34.5
0 ... 14.5 580
212 °F
R50 2" Ø 45.5 0 ... 5.8 580
www.koboldusa.com
subject to change without prior notice.
No responsibility taken for errors;
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly)
Model DRM Size Code Size Note Ø Diaphragm
DRM-611
SMS
R40 1 ½"
SMS socket with union nut, capillary
R50 2" Ø 45.5 0 ... 5.8 580
Ø 34.5
Max. Media
Temperature
392 °F
Min. Span
Max. Span
(PSIG)
0 ... 1.4 580
(PSIG)
DRM-612
Clamp
DRM-613
Clamp
DRM-614
APV-RJT
R25 1"
Ø 18
0 ...58 232
F40 1 ½" Ø 35.5 0 ...14.5 232
F50 2" Ø 45.5 0 ...5.8 232
Tri-Clamp, direct
212 °F
R65 2 ½" Ø 52 0 ...5.8 232
R80 3" Ø 64 0 ...3.6 145
R25 1"
Ø 18
0 ...58 232
F40 1 ½" Ø 35.5 0 ...14.5 232
F50 2" Ø 45.5 0 ...5.8 232
Tri-Clamp, capillary
392 °F
R65 2 ½" Ø 52 0 ...5.8 232
R80 3" Ø 64 0 ...3.6 145
R20 1"
R40 1 ½" Ø 42.5 0 ... 8.7 1450
Union-nut, direct
Ø 29.5
0 ... 23.2 1450
212 °F
R50 2" Ø 56 0 ... 5.8 1450
DRM-615
APV-RJT
R20 1"
R40 1 ½" Ø 42.5 0 ...8.7 1450
R50 2" Ø 56 0 ... 5.8 1450
DRM-616
R45 M 45 x 2 Union-nut, direct Ø 23.8 212 °F 0 ... 23.2 23200
DRM-617
R45 M 45 x 2 Union-nut, capillary Ø 23.8 248 °F 0 ... 23.2 23200
No responsibility taken for errors; subject to change without prior notice.
Union-nut, capillary
Ø 29.5
www.koboldusa.com
0 ... 23.2 1450
392 °F
13
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly)
Model DRM Size Code Size Note Ø Diaphragm
DRM-620
R20 G ¾ Union-nut, capillary Ø 23.8 662 °F 0 ... 23.2 8700
DRM-620/1
R20 G ¾ Union-nut, capillary Ø 23.8 662 °F 0 ... 23.2 8700
DRM-621
F38 Ø 38 mm Flange, direct Ø 38 482 °F 0 ... 5.8 580
Max. Media
Temperature
Min. Span
(PSIG)
Max. Span
(PSIG)
DRM-622
DRM-622/1
DRM-624
DRM-624/1
DRM-625
F48 Ø 48 mm
F48 1 Ø 48 mm Ø 48 0 ... 5.8 580
Flange, direct
Ø 48
0 ... 5.8 580
212 °F
F48 2 Ø 48 mm Ø 48 0 ... 5.8 580
F48 Ø 48 mm
F48 1 Ø 48 mm Ø 48 0 ... 5.8 580
Flange, capillary
Ø 48
0 ... 5.8 580
392 °F
F48 2 Ø 48 mm Ø 48 0 ... 5.8 580
F1H Ø 100 mm Flange, direct
0 ... 3.6 580
212 °F
F1H T Ø 100 mm Flange, direct 0 ... 3.6 580
Ø 63.5
F1H Ø 100 mm Flange, capillary 482 °F 0 ... 3.6 580
R15 G ½
0 ... 3.6 580
14
DRM-625/1
N15 ½ NPT 0 ... 3.6 580
Fixed male, direct Ø 63.5 212 °F
I15 G ½ IG 0 ... 3.6 580
R15 G ½
N15 ½ NPT 0 ... 3.6 580
Fixed male, capillary Ø 63.5 482 °F
0 ... 3.6 580
I15 G ½ IG 0 ... 3.6 580
No responsibility taken for errors;
www.koboldusa.com
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly)
Model DRM Size Code Size Note Ø Diaphragm
DRM-626
PN 25
DRM-626
PN 100
DRM-626
PN 250
R08 A025 G ¼ male Fixed male, direct Ø 56 R08 I025 G ¼ female Fixed female, direct Ø 56 0 ... 5.8 362.5 R15 A025 G ½ male Fixed male, direct Ø 56 0 ... 5.8 362.5 R15 I025 G ½ female Fixed female, direct Ø 56 0 ... 5.8 362.5 N15 A025 ½ NPT male Fixed male, direct Ø 56 0 ... 5.8 362.5 R08 A100 G ¼ male Fixed male, direct Ø 56 R08 I100 G ¼ female Fixed female, direct Ø 56 0 ... 5.8 1450 R15 A100 G ½ male Fixed male, direct Ø 56 0 ... 5.8 1450 R15 I100 G ½ female Fixed female, direct Ø 56 0 ... 5.8 1450 N15 A100 ½ NPT male Fixed male, direct Ø 56 0 ... 5.8 1450 R08 A250 G ¼ male Fixed male, direct Ø 56 R08 I250 G ¼ female Fixed female, direct Ø 56 0 ... 5.8 3625 R15 A250 G ½ male Fixed male, direct Ø 56 0 ... 5.8 3625 R15 I250 G ½ female Fixed female, direct Ø 56 0 ... 5.8 3625 N15 A250 ½ NPT male Fixed male, direct Ø 56 0 ... 5.8 3625
Max. Media
Temperature
176 °F
176 °F
176 °F
Min. Span
(PSIG)
Max. Span
(PSIG)
0 ... 5.8 362.5
0 ... 5.8 1450
0 ... 5.8 3625
DRM-627
PN 25
R08 A025 G ¼ male Fixed male, capillary Ø 56 R08 I025 G ¼ female Fixed female, capillary Ø 56 0 ... 5.8 362.5 R15 A025 G ½ male Fixed male, capillary Ø 56 0 ... 5.8 362.5 R15 I025 G ½ female Fixed female, capillary Ø 56 0 ... 5.8 362.5 N15 A025 ½ NPT male Fixed male, capillary Ø 56 0 ...5.8 362.5
DRM-627
PN 100
R08 A100 G ¼ male Fixed male, capillary Ø 56 R08 I100 G ¼ female Fixed female, capillary Ø 56 0 ... 5.8 1450 R15 A100 G ½ male Fixed male, capillary Ø 56 0 ... 5.8 1450 R15 I100 G ½ female Fixed female, capillary Ø 56 0 ... 5.8 1450 N15 A100 ½ NPT male Fixed male, capillary Ø 56 0 ... 5.8 1450
DRM-627
PN 250
R08 A250 G ¼ male Fixed male, capillary Ø 56 R08 I250 G ¼ female Fixed female, capillary Ø 56 0 ... 5.8 3625 R15 A250 G ½ male Fixed male, capillary Ø 56 0 ... 5.8 3625 R15 I250 G ½ female Fixed female, capillary Ø 56 0 ... 5.8 3625 N15 A250 ½ NPT male Fixed male, capillary Ø 56 0 ... 5.8 3625
DRM-628
PN 06
F25P06 DN 25 F32P06 DN 32 Ø 30 0 ... 23.2 87 F40P06 DN 40 Ø 38 0 ... 8.7 87 F50P06 DN 50 Ø 48 0 ... 5.8 87 F65P06 DN 65 Ø 64 0 ... 3.6 87 F80P06 DN 80 Ø 64 0 ... 3.6 87 N1HP06 DN 100 Ø 64 0 ... 3.6 87
DRM-628
PN 16
F25P16 DN 25 F32P16 DN 32 Ø 30 0 ... 23.2 232 F40P16 DN 40 Ø 38 0 ... 8.7 232 F50P16 DN 50 Ø 48 0 ... 5.8 232 F65P16 DN 65 Ø 64 0 ... 3.6 232 F80P16 DN 80 Ø 64 0 ... 3.6 232 N1HP16 DN 100 Ø 64 0 ... 3.6 232
DRM-628
PN 40
F25P40 DN 25 F32P40 DN 32 Ø 30 0 ... 23.2 580 F40P40 DN 40 Ø 38 0 ... 8.7 580 F50P40 DN 50 Ø 48 0 ... 5.8 580 F65P40 DN 65 Ø 64 0 ... 3.6 580 F80P40 DN 80 Ø 64 0 ... 3.6 580 N1HP40 DN 100 Ø 64 0 ... 3.6 580
No responsibility taken for errors; subject to change without prior notice.
Flange to EN1092-1, direct
Flange to EN1092-1, direct
Flange to EN1092-1, direct
www.koboldusa.com
Ø 24
Ø 24
Ø 24
0 ... 5.8 362.5
482 °F
0 ... 5.8 1450
482 °F
0 ... 5.8 3625
482 °F
0 ... 23.2 87
176 °F
0 ... 23.2 232
176 °F
0 ... 23.2 580
176 °F
15
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly)
Model DRM Size Code Size Note Ø Diaphragm
DRM-629
PN 06
DRM-629
PN 16
DRM-629
PN 40
F25P06 DN 25
Ø 24
F32P06 DN 32 Ø 30 0 ... 23.2 87
F40P06 DN 40 Ø 38 0 ... 8.7 87
F50P06 DN 50 Ø 48 0 ... 5.8 87
Flange to EN1092-1, capillary
F65P06 DN 65 Ø 64 0 ... 3.6 87
F80P06 DN 80 Ø 64 0 ... 3.6 87
F1HP06 DN 100 Ø 64 0 ... 3.6 87
F25P16 DN 25
Ø 24
F32P16 DN 32 Ø 30 0 ... 23.2 232
F40P16 DN 40 Ø 38 0 ... 8.7 232
F50P16 DN 50 Ø 48 0 ... 5.8 232
Flange to EN1092-1, capillary
F65P16 DN 65 Ø 64 0 ... 3.6 232
F80P16 DN 80 Ø 64 0 ... 3.6 232
F1HP16 DN 100 Ø 64 0 ...3.6 232
F25P40 DN 25
Ø 24
F32P40 DN 32 Ø 30 0 ... 23.2 580
F40P40 DN 40 Ø 38 0 ... 8.7 580
F50P40 DN 50 Ø 48 0 ... 5.8 580
Flange to EN1092-1, capillary
F65P40 DN 65 Ø 64 0 ... 3.6 580
F80P40 DN 80 Ø 64 0 ... 3.6 580
F1HP40 DN 100 Ø 64 0 ... 3.6 580
Max. Media
Temperature
482 °F
482 °F
482 °F
Min. Span
Max. Span
(PSIG)
0 ... 23.2 87
0 ... 23.2 232
0 ... 23.2 580
(PSIG)
DRM 630
PVC
DRM-630/1
PVC
DRM-631
PP
DRM-631/1
PP
DRM-632
PVDF
DRM-632/1
PVDF
R08 G ¼ female
R15 G ½ female Ø 64 0 ...3.6 145
Fixed female, direct
Ø 64
0 ... 3.6 145
N15 ½ NPT female Ø 64 0 ... 3.6 145
104 °F
R08 G ¼ female
R15 G ½ female Ø 64 0 ... 3.6 145
Fixed female, capillary
Ø 64 0 ... 3.6 145
N15 ½ NPT female Ø 64 0 ... 3.6 145
R08 G ¼ female
R15 G ½ female Ø 64 0 ... 3.6 145
Fixed female, direct
Ø 64
0 ... 3.6 145
N15 ½ NPT female Ø 64 0 ... 3.6 145
104 °F
R08 G ¼ female
R15 G ½ female Ø 64 0 ... 3.6 145
Fixed female, capillary
Ø 64 0 ... 3.6 145
N15 ½ NPT female Ø 64 0 ... 3.6 145
R08 G ¼ female
R15 G ½ female Ø 64 0 ... 3.6 232
Fixed female, direct
Ø 64
0 ... 3.6 232
N15 ½ NPT female Ø 64 0 ... 3.6 232
122 °F
R08 G ¼ female
R15 G ½ female Ø 64 0 ... 3.6 232
Fixed female, capillary
Ø 64 0 ... 3.6 232
N15 ½ NPT female Ø 64 0 ... 3.6 232
No responsibility taken for errors;
16
www.koboldusa.com
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly)
Model DRM Size Code Size Note Ø Diaphragm
DRM-633
DRM-633/1
F50 DN 50
F1H DN 100 Ø 64 0 ... 3.6 580
F50 DN 50
F1H DN 100 Ø 64 0 ... 3.6 580
Flange to DIN2527 Form C, direct
Flange to DIN2527 Form C, capillary
Ø 64
Ø 64
Max. Media
Temperature
212 °F
482 °F
Min. Span
Max. Span
(PSIG)
0 ... 3.6 580
0 ... 3.6 580
(PSIG)
DRM-634
150 lbs
DRM-634
300 lbs
DRM-634
600 lbs
DRM-634
1500 lbs
A25P150 1"
Ø 30
0 ... 23.2 145
A32P150 1¼" Ø 38 0 ... 8.7 145
A40P150 1 ½" Ø 38 0 ... 8.7 145
A50P150 2" Ø 48 0 ... 5.8 145
A65P150 2 ½" Ø 48 0 ... 5.8 145
Flange to ASME B16.5, direct
176 °F
A80P150 3" Ø 64 0 ... 3.6 145
A90P150 3 ½" Ø 64 0 ... 3.6 145
A1HP150 4" Ø 64 0 ... 3.6 145
A25P300 1"
Ø 30
0 ... 23.2 290
A32P300 1¼" Ø 38 0 ... 8.7 290
A40P300 1 ½" Ø 38 0 ... 8.7 290
A50P300 2" Ø 48 0 ... 5.8 290
A65P300 2 ½" Ø 48 0 ... 5.8 290
Flange to ASME B16.5, direct
176 °F
A80P300 3" Ø 64 0 ... 3.6 290
A90P300 3 ½" Ø 64 0 ... 3.6 290
A1HP300 4" Ø 64 0 ... 3.6 290
A25P600 1"
Ø 30
0 ... 23.2 580
A32P600 1¼" Ø 38 0 ... 8.7 580
A40P600 1 ½" Ø 38 0 ... 8.7 580
A50P600 2" Ø 48 0 ... 5.8 580
A65P600 2 ½" Ø 48 0 ... 5.8 580
Flange to ASME B16.5, direct
176 °F
A80P600 3" Ø 64 0 ... 3.6 580
A90P600 3 ½" Ø 64 0 ... 3.6 580
A1HP600 4" Ø 64 0 ... 3.6 580
A25P1K5 1"
Ø 30
0 ... 23.2 1450
A32P1K5 1¼" Ø 38 0 ... 8.7 1450
A40P1K5 1 ½" Ø 38 0 ... 8.7 1450
A50P1K5 2" Ø 48 0 ... 5.8 1450
A65P1K5 2 ½" Ø 48 0 ... 5.8 1450
Flange to ASME B16.5, direct
176 °F
A80P1K5 3" Ø 64 0 ... 3.6 1450
A90P1K5 3 ½" Ø 64 0 ... 3.6 1450
A1HP1K5 4" Ø 64 0 ... 3.6 1450
DRM-635
150 lbs
A25P150 1"
A32P150 1¼" Ø 38 0 ... 8.7 145
A40P150 1 ½" Ø 38 0 ... 8.7 145
A50P150 2" Ø 48 0 ... 5.8 145
A65P150 2 ½" Ø 48 0 ... 5.8 145
A80P150 3" Ø 64 0 ... 3.6 145
A90P150 3 ½" Ø 64 0 ... 3.6 145
A1HP150 4" Ø 64 0 ... 3.6 145
No responsibility taken for errors; subject to change without prior notice.
Flange to ASME B16.5, capillary
Ø 30
www.koboldusa.com
0 ... 23.2 145
482 °F
17
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly)
Model DRM Size Code Size Note Ø Diaphragm
DRM-635
300 lbs
DRM-635
600 lbs
DRM-635
1500 lbs
A25P300 1"
Ø 30
A32P300 1¼" Ø 38 0 ... 8.7 290 A40P300 1 ½" Ø 38 0 ... 8.7 290 A50P300 2" Ø 48 0 ... 5.8 290 A65P300 2 ½" Ø 48 0 ... 5.8 290
Flange to ASME B16.5, capillary
A80P300 3" Ø 64 0 ... 3.6 290 A90P300 3 ½" Ø 64 0 ... 3.6 290 A1HP300 4" Ø 64 0 ... 3.6 290 A25P600 1"
Ø 30
A32P600 1¼" Ø 38 0 ... 8.7 580 A40P600 1 ½" Ø 38 0 ... 8.7 580 A50P600 2" Ø 48 0 ... 5.8 580 A65P600 2 ½" Ø 48 0 ... 5.8 580
Flange to ASME B16.5, capillary
A80P600 3" Ø 64 0 ... 3.6 580 A90P600 3 ½" Ø 64 0 ... 3.6 580 A1HP600 4" Ø 64 0 ... 3.6 580 A25P1K5 1"
Ø 30
A32P1K5 1¼" Ø 38 0 ... 8.7 1450 A40P1K5 1 ½" Ø 38 0 ... 8.7 1450 A50P1K5 2" Ø 48 0 ... 5.8 1450 A65P1K5 2 ½" Ø 48 0 ... 5.8 1450
Flange to ASME B16.5, capillary
A80P1K5 3" Ø 64 0 ... 3.6 1450 A90P1K5 3 ½" Ø 64 0 ... 3.6 1450 A1HP1K5 4" Ø 64 0 ... 3.6 1450
Max. Media
Temperature
482 °F
482 °F
482 °F
Min. Span
Max. Span
(PSIG)
0 ... 23.2 290
0 ... 23.2 580
0 ... 23.2 1450
(PSIG)
DRM-637
PN 06
DRM-637
PN 16
DRM-637
PN 40
F25P06 DN 25
Ø 24
0 ... 23.2 87
F32P06 DN 32 Ø 30 0 ... 23.2 87
F40P06 DN 40 Ø 38 0 ... 14.5 87
F50P06 DN 50 Ø 48 0 ... 8.7 87
Flange to EN1092-1, direct
176 °F
F65P06 DN 65 Ø 64 0 ... 3.6 87
F80P06 DN 80 Ø 64 0 ... 3.6 87
N1HP06 DN 100 Ø 64 0 ... 3.6 87
F25P16 DN 25
Ø 24
0 ... 23.2 232
F32P16 DN 32 Ø 30 0 ... 23.2 232
F40P16 DN 40 Ø 38 0 ... 14.5 232
F50P16 DN 50 Ø 48 0 ... 8.7 232
Flange to EN1092-1, direct
176 °F
F65P16 DN 65 Ø 64 0 ...3.6 232
F80P16 DN 80 Ø 64 0 ... 3.6 232
N1HP16 DN 100 Ø 64 0 ... 3.6 232
F25P40 DN 25
Ø 24
0 ... 23.2 580
F32P40 DN 32 Ø 30 0 ... 23.2 580
F40P40 DN 40 Ø 38 0 ... 14.5 580
F50P40 DN 50 Ø 48 0 ... 8.7 580
Flange to EN1092-1, direct
176 °F
F65P40 DN 65 Ø 64 0 ... 3.6 580
F80P40 DN 80 Ø 64 0 ... 3.6 580
N1HP40 DN 100 Ø 64 0 ... 3.6 580
No responsibility taken for errors;
18
www.koboldusa.com
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly) (Continued)
Model DRM Code Size Note Ø Diaphragm
DRM-638
PN 06
F25P06 DN 25
Ø 24
F32P06 DN 32 Ø 30 0 ... 23.2 87
F40P06 DN 40 Ø 38 0 ... 14.5 87
F50P06 DN 50 Ø 48 0 ... 8.7 87
Flange to EN1092-1, capillary
F65P06 DN 65 Ø 64 0 ... 3.6 87
F80P06 DN 80 Ø 64 0 ... 3.6 87
F1HP06 DN 100 Ø 64 0 ... 3.6 87
DRM-638
PN 16
F25P16 DN 25
Ø 24
F32P16 DN 32 Ø 30 0 ... 23.2 232
F40P16 DN 40 Ø 38 0 ... 14.5 232
F50P16 DN 50 Ø 48 0 ... 8.7 232
Flange to EN1092-1, capillary
F65P16 DN 65 Ø 64 0 ... 3.6 232
F80P16 DN 80 Ø 64 0 ... 3.6 232
F1HP16 DN 100 Ø 64 0 ... 3.6 232
DRM-638
PN 40
F25P40 DN 25
Ø 24
F32P40 DN 32 Ø 30 0 ... 23.2 580
F40P40 DN 40 Ø 38 0 ... 14.5 580
F50P40 DN 50 Ø 48 0 ... 8.7 580
Flange to EN1092-1, capillary
F65P40 DN 65 Ø 64 0 ... 3.6 580
F80P40 DN 80 Ø 64 0 ... 3.6 580
F1HP40 DN 100 Ø 64 0 ... 3.6 580
DRM-639
150 lbs
A25P150 1"
Ø 30
A32P150 1¼" Ø 38 0 ... 15 145
A40P150 1 ½" Ø 38 0 ... 15 145
A50P150 2" Ø 48 0 ... 10 145
A63P150 2 ½" Ø 48 0 ... 10 145
Flange to ASME B16.5, direct
A75P150 3" Ø 64 0 ... 4 145
A85P150 3 ½" Ø 64 0 ... 4 145
A1HP150 4" Ø 64 0 ... 4 145
DRM-639
300 lbs
A25P300 1"
Ø 30
A32P300 1¼" Ø 38 0 ... 15 290
A40P300 1 ½" Ø 38 0 ... 15 290
A50P300 2" Ø 48 0 ... 10 290
A63P300 2 ½" Ø 48 0 ... 10 290
Flange to ASME B16.5, direct
A75P300 3" Ø 64 0 ... 4 290
A85P300 3 ½" Ø 64 0 ... 4 290
A1HP300 4" Ø 64 0 ... 4 290
DRM-639
600 lbs
A25P600 1"
Ø 30
A32P600 1¼" Ø 38 0 ... 15 580
A40P600 1 ½" Ø 38 0 ... 15 580
A50P600 2" Ø 48 0 ... 10 580
A63P600 2 ½" Ø 48 0 ... 10 580
Flange to ASME B16.5, direct
A75P600 3" Ø 64 0 ... 4 580
A85P600 3 ½" Ø 64 0 ... 4 580
A1HP600 4" Ø 64 0 ... 4 580
Max. Media
Temperature
482 °F
482 °F
482 °F
176 °F
176 °F
176 °F
Min. Span
Max. Span
(PSIG)
0 ... 23.2 87
0 ... 23.2 232
0 ... 23.2 580
0 ... 15 145
0 ... 15 290
0 ... 15 580
(PSIG)
No responsibility taken for errors; subject to change without prior notice.
www.koboldusa.com
19
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly) (Continued)
Model DRM Size Code Size Note Ø Diaphragm
DRM-639
1500 lbs
A25P1K5 1"
Ø 30
A32P1K5 1¼" Ø 38 0 ... 15 1450 A40P1K5 1 ½" Ø 38 0 ... 15 1450 A50P1K5 2" Ø 48 0 ... 10 1450
Flange to ASME B16.5, direct
A63P1K5 2 ½" Ø 48 0 ... 10 1450 A75P1K5 3" Ø 64 0 ... 4 1450 A1HP1K5 4" Ø 64 0 ... 4 1450
Max. Media
Temperature
176 °F
Min. Span
(PSIG)
Max. Span
(PSIG)
0 ... 15 1450
DRM-640
150 lbs
DRM-640
300 lbs
DRM-640
600 lbs
DRM-640
1500 lbs
A25P150 1"
Ø 30
0 ... 15 145
A32P150 1¼" Ø 38 0 ... 15 145 A40P150 1 ½" Ø 38 0 ... 15 145 A50P150 2" Ø 48 0 ... 10 145 A63P150 2 ½" Ø 48 0 ... 10 145
Flange to ASME B16.5, capillary
482 °F
A75P150 3" Ø 64 0 ... 4 145 A85P150 3 ½" Ø 64 0 ... 4 145 A1HP150 4" Ø 64 0 ... 4 145 A25P300 1"
Ø 30
0 ... 15 290
A32P300 1¼" Ø 38 0 ... 15 290 A40P300 1 ½" Ø 38 0 ... 15 290 A50P300 2" Ø 48 0 ... 10 290 A63P300 2 ½" Ø 48 0 ... 10 290
Flange to ASME B16.5, capillary
482 °F
A75P300 3" Ø 64 0 ... 4 290 A85P300 3 ½" Ø 64 0 ... 4 290 A1HP300 4" Ø 64 0 ... 4 290 A25P600 1"
Ø 30
0 ... 15 580
A32P600 1¼" Ø 38 0 ... 15 580 A40P600 1 ½" Ø 38 0 ... 15 580 A50P600 2" Ø 48 0 ... 10 580 A63P600 2 ½" Ø 48 0 ... 10 580
Flange to ASME B16.5, capillary
482 °F
A75P600 3" Ø 64 0 ... 4 580 A85P600 3 ½" Ø 64 0 ... 4 580 A1HP600 4" Ø 64 0 ... 4 580 A25P1K5 1"
Ø 30
0 ... 15 1450
A32P1K5 1¼" Ø 38 0 ... 15 1450 A40P1K5 1 ½" Ø 38 0 ... 15 1450 A50P1K5 2" Ø 48 0 ... 10 1450 A63P1K5 2 ½" Ø 48 0 ... 10 1450
Flange to ASME B16.5, capillary
482 °F
A75P1K5 3" Ø 64 0 ... 4 1450 A1HP1K5 4" Ø 64 0 ... 4 1450
No responsibility taken for errors;
20
www.koboldusa.com
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly) (Continued)
Model DRM Size Code Size Note Ø Diaphragm
DRM 500
ISO Sterile
D15
D20
D25 DN 25 Inline 0 ... 8.7 580
D32 DN 32 Inline 0 ... 8.7 580
D40 DN 40 Inline 0 ... 5.8 580
D50
DN 15
DN 20
DN 50
Inline
Inline 0 ... 23.2 580
Inline, direct
Inline 0 ... 5.8 580
Max. Media
Temperature
176 °F
Min. Span
Max. Span
(PSIG)
0 ... 23.2 580
(PSIG)
DRM 501
ISO Sterile
DRM 502
Clamp ISO 2852
DRM 503
Clamp ISO 2852
D15
D20
D25 DN 25 Inline 0 ... 8.7 580
D32 DN 32 Inline 0 ... 8.7 580
DN 15
DN 20
Inline, capillary
Inline
0 ... 23.2 580
Inline 0 ... 23.2 580
176 °F
D40 DN 40 Inline 0 ... 5.8 580
D50 DN 50 Inline 0 ... 5.8 580
D15 DN 15
Inline
0 ... 23.2 580
D20 DN 20 Inline 0 ... 23.2 580
D25
D32
DN 25
DN 32
Inline, direct
Inline 0 ... 8.7 580
Inline 0 ... 8.7 580
176 °F
D40 DN 40 Inline 0 ... 5.8 580
D50 DN 50 Inline 0 ... 5.8 580
D15 DN 15
Inline
0 ...23.2 580
D20 DN 20 Inline 0 ... 23.2 580
D25 DN 25 Inline 0 ... 8.7 580
D32 DN 32 Inline 0 ... 8.7 580
D40
DN 40
Inline, capillary
176 °F
Inline 0 ... 5.8 580
D50 DN 50 Inline 0 ... 5.8 580
No responsibility taken for errors; subject to change without prior notice.
www.koboldusa.com
21
Heavy Duty Pressure Transmitter Model PAS
Application Index
Please fill out the following Application Data Sheet when inquiring/ordering model PAS assembly with diaphragm seal model DRM
Order/ Inquiry Ref./ Item No.
Pressure Transmitter (Model, Calibration range) Diaphragm Seal (Model, Size Code) Diaphragm material of DRM (wetted part)
Media:
Operating density g/cm² or S.G. Operating viscosity cSt
Temperature: nominal minimal maximal
Medium temperature ° C / °F Ambient temperature ° C / °F Rinsing temperature diaphragm seal ° C / °F Rinsing temperature capillary ° C / °F
Pressure Specification: Value
1.1) Operating pressure static or 1.2 bar / psi
1.2) Operating pressure dynamic min + max or 1.3 bar / psi
1.3) Operating pressure as frequency in Hz Hz
2.) Max. negative pressure
3.) Max. over pressure
4.1) Display damping: without / light / middle / strong or 4.2
4.2) Pressure decrease with time + range
Arrangement with Direct Mounting:
1.) Standard (DRM six o'clock position) or 2.0
2.) Left (DRM nine o'clock position) or 3.0
3.) Right (DRM three o'clock position, see Fig. 1) or 4.0
4.) Special, with description or 5.0
5.) Position (vertically/horizontally) with pipe diaphragm seal
Arrangement with Capillary:
1.) Standard (DRM six o'clock position) or 2.0
2.) On the side (DRM three or 9 o'clock position) or 3.0
3.) Top (DRM twelve o'clock position) or 4.0
4.) Special, with description or 5.0
5.) Position (vertically/horizontally) with pipe diaphragm seal
Capillary (Stainless steel 1.4571/316Ti):
Length in 'inches' in Protection hose required (Yes/No)
Continued......
No responsibility taken for errors;
22
www.koboldusa.com
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
Application Index
Please fill out the following Application Data Sheet when inquiring/ordering model PAS assembly with diaphragm seal model DRM
Order/ Inquiry Ref./ Item No.
Height Adjustment:
No
1.) PAS same level as DRM (diaphragm - pressure transmitter) or 2.) Yes
2.) PAS higher than DRM (specify ∆h as in Fig. 2 or Fig. 3) or 3.) m
3.) PAS lower than DRM (specify ∆h as in Fig. 2 or Fig. 3) m
Options:
Extended diaphragm seal (Mark the desired box)
No
Yes
If Yes, length 'RL' of extended diaphragm seal (in mm)
If Yes, length 'RL' of extended diaphragm seal (in inches)
Fill Liquid (Mark the desired box)
Glycerine oil (silicone free, food grade) for Operation temp. (14 … 176 °F)
Paraffine oil (silicone free, food grade) for Operation temp. (14 … 248 °F)
Silicone oil for Operation temp. (-40 … 392 °F)
Silicone oil for Operation temp. (-4 … 662 °F) Silicone oil for Operation temp. (-4 … 752 °F)
No responsibility taken for errors; subject to change without prior notice.
www.koboldusa.com