The KOBOLD Pressure Transmitter model PAS is a
microprocessor based high performance transmitter, which
has a scalable pressure calibration and output signal. It
automatically compensates for ambient temperature and
process variables. Communication with the instrument and
configuration of various parameters is possible via HART®
protocol. All of the sensor's data is input, modified and stored
via EEPROM.
Features
Superior Performance
●O High Reference Accuracy:
±0.075 % of Calibrated Span
●O Long-term Stability
●O High Rangeability (100 : 1)
Flexibility
●O Data configuration with HART
●O Measurement of gauge or absolute pressure
®
configurator
Reliability
●O Continuous self-diagnostic function
●O Automatic ambient temperature compensation
●O EEPROM write-protection
●O Fail-mode process function
Transmitter Description
Electronics Module
The Electronics module consists of a circuit board sealed in
an enclosure. There is an MCU module, an analog module,
an LCD module, and a terminal module within the transmitter.
The MCU module acquires the digital value from the analog
module and applies correction coefficients selected from
EEPROM. The output section of the MCU module converts
the digital signal to a 4…20 mA output. The MCU module
communicates with the HART®-based configurator or control
system, such as DCS (Distributed Control System). The
power section of the MCU module has a DC-to-DC power
conversion circuit and an input/output isolation circuit. The
LCD module plugs into the MCU module and displays the
digital output in a user configured unit.
Sensor Inputs
The pressure transmitter model PAS is available as a piezoresistive pressure transmitter which measures gauge pressure
as well as absolute pressure. The sensor module converts
the resistance into a digital value. The MCU module calculates
the process pressure based on this digital value.
Functional Block Diagram
Sensor Part
A/D-Conversion
EEPROM
Piezoelectric sensor
• Gauge pressure
• Absolute pressure
2
www.koboldusa.com
MCU Part
Microprocessor
· Input Sensor Value
· Engineering Units
· Re–range (Zero / Span)
· Zero Point Adjustment
· DA Trimming
· Damping / Filtering
·
LCD Engineering Mode
· Diagnostics
· Self Compensation
· Communications
· LCD Display
· Configuration Data
4~20mA
DAC
®
HART
HART® Protocol
with Host
No responsibility taken for errors;
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
The sensor modules include the following features:
• The software of the transmitter compensates for thermal
effects, improving performance.
• Precise Input Compensation during operation is achieved
with temperature and pressure correction coefficients that
are characterized over the range of the transmitter and
stored in the sensor module's EEPROM memory.
• EEPROM stores sensor information and correction
coefficients separately from the MCU module, allowing for
easy repair, reconfiguration and replacement.
Basic Setups
The following settings can be easily configured from any host
that can support HART® protocol:
• Operational parameters
• 4 … 20 mA (zero points/span)
• Engineering units
• Damping time: 0.25…60 sec.
• Tag: 8 alphanumeric characters
• Descriptor: 16 characters
• Message: 32 characters
• Date: day/month/year
Calibration and Adjustment
• Lower/Upper range (zero/span)
• Sensor zero adjustment
• Zero point adjustment
• DAC output adjustment
• Transfer function
• Self-compensation
Self-Diagnostics and Others
• CPU & Analog Module Fault Detection
• Communication error
• Fail-mode handling
• LCD indication
• Temperature measurement of sensor module
Process Connection via Diaphragm Seals
For connecting the model PAS to different process
connections, diverse diaphragm seal versions are necessary.
They can be connected to the pressure transmitter directly or
via a capillary tube. Depending on the application; different
combinations of diaphragm seals, capillary tubes and fill
fluids are possible. To clarify those possibilities, the special
connections via diaphragm seals should be requested
separately from the pressure transmitter.
No responsibility taken for errors;
subject to change without prior notice.
www.koboldusa.com
3
Heavy Duty Pressure Transmitter Model PAS
Technical Details
Measuring Principle: Piezoresistive Sensor
Measuring Span: -14.5…21.7 PSIG up to 0…8700
(Depending on instrument version),
zero and span values can be set
anywhere within the range limits.
Span must be greater than or
equal to the minimum span.
Accuracy: 0.075 % of calibrated span
Process Temperature: -40...248 °F
(Approval codes may effect limits.
Max. ambient temperature at
LCD = 176 °F.)
(Valid for stand-alone unit only, without assembled
diaphragm seals.)
Model G -14.5...43.5 PSIG (for Range 3)
-14.5...435 PSIG (for Range 4)
0...1552.5 PSIG (for Range 5)
0...5800 PSIG (for Range 6)
0...10875 PSIG (for Range 7)
Model A 0...72.5 PSIG (for Range 4)
0...435 PSIG (for Range 5)
0...754 PSIG (for Range 6)
Maximum Load: 250 Ω at 17.5 V
550 Ω at 24 V
Max. loop resistance =
DC
DC
(U - 12 VDC)
0.022 A
Electrical Connection: ½" NPT conduit with M4
screw terminals,
G ½ conduit with M4 screw
terminals
Output:Two wire 4…20 mA, user-configurable for linear output,
digital process value superimposed
on 4…20 mA signal, available
to any host that conforms to the
HART® protocol
Update Time: 0.12 seconds
Turn-On Time: 3 seconds
Protection: IP 67 for standard (code S)
Weight: 3.8 lbs (excluding options)
6.3 lbs (st. steel housing option)
Failure Mode: Fail high: current ≥ 21.1 mA
Fail low: current ≤ 3.78 mA
EMC Conformity
Standards: EMI (emission) - EN 50081-2:1993
Process Connections: ½" NPT female
Mounting Position: Upright
Display: 5 Digit LCD
Power Supply: 12 … 45 VDC -operation
17.5 … 45 VDC -HART®
communications
Technical Data for Version with 50 mm Extended
Diaphragm
(Model PAS-P, Engineered for the Paper/Pulp Industry)
Application:Level and gauge pressure
measurement
Accuracy: ± 0.2% of calibrated span @ 68 °F
Long Term Stability: Application dependent, typically
± 0.125% of URL / 1 year
Process Temperature: 68...95 °F
Ambient Temperature: 68...95 °F
Materials:
O-ring: FKM
Extended Sleeve:304 Stainless Steel
Process Connection: 316-Ti / 316 Stainless Steel
Other Specifications: Same as standard models
No responsibility taken for errors;
4
www.koboldusa.com
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
Order Details (Example: PAS- G EE 3 S 4 N S0 0):
ModelVersion
..G.. = Gauge Pressure
PAS-
..A.. = Absolute Pressure
..EE.. = 316L st. st. / 316 st. steel
Order Details Continued:
Material
Diaphragm/Other
Measuring RangeMeasuring Span
for PAS-G
..3.. = -14.5...21.7 PSIG
..4.. = -14.5...217 PSIG
..5.. = 0...725 PSIG
..6.. = 0...3625 PSIG
..7.. = 0...8700 PSIG
6 W.C....36.3 PSIG
60 W.C....232 PSIG
200 W.C....725 PSIG
36.3 PSIG...3625 PSIG
87 PSIG...8700 PSIG
for PAS-A
..4.. = 0...36 PSIA
..5.. = 0...217 PSIA
..6.. = 0...362 PSIA
10 W.C....36.3 PSIA
60 W.C....217 PSIA
100 W.C....362 PSIA
Fill Liquid
Process
Connection
Electrical
Connection
ApprovalsOptions
..0 =without
..N.. =½" NPT epoxy-
polyester painted
aluminium
..S.. = silicone ..4.. = ½" NPT female
..G.. =G ½ epoxy-
polyester painted
aluminium
1)
Diaphragm seal model and application data to be clearly specified. The application Index on page 17-18 must be completed.
For summary of diaphragm seal models and possible ranges, see page 9 onwards. For dimensional details see DRM data sheet.
..S0.. = standard
(waterproof IP 67)
..F0.. = ATEX, flameproof,
Ex d
..E =oil free finish
..M = housing in stainless steel
..N1) = mounting of PAS onto
diaphragm seal
Order Details Mounting Brackets:
DescriptionOrder Number
Angle type bracket for PAD/PAS
vertical pipe mounting for PAS
vertical pipe mounting for PAD
incl. U-Clamp for 2“ pipe mounting bracket and 2 x mounting nuts/ washers
incl. 4 x mounting screws for PAS
incl. 4 x mounting screws for PAD
Flat type bracket for PAD/PAS
horizontal pipe mounting for PAS
vertical pipe mounting for PAD
incl. U-Clamp for 2“ pipe mounting bracket and mounting nuts/ washers
incl. 4 x mounting bolts and washers for PAS
incl. 4 x mounting bolts for PAD
ZUB-PAD/PAS-K
ZUB-PAD/PAS-L
Order Details Manifold Valve:
DescriptionOrder Number
2-way Manifold Valve, Direct Mount, Machined
No responsibility taken for errors;
subject to change without prior notice.
www.koboldusa.com
V-2003CDADABAA
5
Heavy Duty Pressure Transmitter Model PAS
Order Details for PAS-..P Extended Diaphragm Version for Paper/Pulp Industries (Example: PAS-P ES 3 S A N S 0 0)
Model
PAS-P..
..ES.. = 316 SS / 304 SS,
316L SS, 316-Ti SS
MaterialMeasuring Ranges
Diaphragm/OtherCodeMeasuring RangeMeasuring Span
..3..-10,000 mm H2O...15,000 mm H2O150 mm H2O...15,000 mm H2O
..4..-10,000 mm H2O...150 m H2O1,500 mm H2O...150 m H2O