ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA,
CZECH REPUBLIC, EGYPT, FRANCE, GERMANY, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA,
MEXICO, NETHERLANDS, PERU, POLAND, REPUBLIC OF KOREA, ROMANIA, SINGAPORE, SPAIN,
SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, UNITED KINGDOM, USA, VIETNAM
01/12- 2016
®
Protocol
KOBOLD Instruments, Inc.
1801 Parkway View Drive
Pittsburgh, PA 15205
The KOBOLD Pressure Transmitter model PAS is a
microprocessor based high performance transmitter, which
has a scalable pressure calibration and output signal. It
automatically compensates for ambient temperature and
process variables. Communication with the instrument and
configuration of various parameters is possible via HART®
protocol. All of the sensor's data is input, modified and stored
via EEPROM.
Features
Superior Performance
●O High Reference Accuracy:
±0.075 % of Calibrated Span
●O Long-term Stability
●O High Rangeability (100 : 1)
Flexibility
●O Data configuration with HART
●O Measurement of gauge or absolute pressure
®
configurator
Reliability
●O Continuous self-diagnostic function
●O Automatic ambient temperature compensation
●O EEPROM write-protection
●O Fail-mode process function
Transmitter Description
Electronics Module
The Electronics module consists of a circuit board sealed in
an enclosure. There is an MCU module, an analog module,
an LCD module, and a terminal module within the transmitter.
The MCU module acquires the digital value from the analog
module and applies correction coefficients selected from
EEPROM. The output section of the MCU module converts
the digital signal to a 4…20 mA output. The MCU module
communicates with the HART®-based configurator or control
system, such as DCS (Distributed Control System). The
power section of the MCU module has a DC-to-DC power
conversion circuit and an input/output isolation circuit. The
LCD module plugs into the MCU module and displays the
digital output in a user configured unit.
Sensor Inputs
The pressure transmitter model PAS is available as a piezoresistive pressure transmitter which measures gauge pressure
as well as absolute pressure. The sensor module converts
the resistance into a digital value. The MCU module calculates
the process pressure based on this digital value.
Functional Block Diagram
Sensor Part
A/D-Conversion
EEPROM
Piezoelectric sensor
• Gauge pressure
• Absolute pressure
2
www.koboldusa.com
MCU Part
Microprocessor
· Input Sensor Value
· Engineering Units
· Re–range (Zero / Span)
· Zero Point Adjustment
· DA Trimming
· Damping / Filtering
·
LCD Engineering Mode
· Diagnostics
· Self Compensation
· Communications
· LCD Display
· Configuration Data
4~20mA
DAC
®
HART
HART® Protocol
with Host
No responsibility taken for errors;
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
The sensor modules include the following features:
• The software of the transmitter compensates for thermal
effects, improving performance.
• Precise Input Compensation during operation is achieved
with temperature and pressure correction coefficients that
are characterized over the range of the transmitter and
stored in the sensor module's EEPROM memory.
• EEPROM stores sensor information and correction
coefficients separately from the MCU module, allowing for
easy repair, reconfiguration and replacement.
Basic Setups
The following settings can be easily configured from any host
that can support HART® protocol:
• Operational parameters
• 4 … 20 mA (zero points/span)
• Engineering units
• Damping time: 0.25…60 sec.
• Tag: 8 alphanumeric characters
• Descriptor: 16 characters
• Message: 32 characters
• Date: day/month/year
Calibration and Adjustment
• Lower/Upper range (zero/span)
• Sensor zero adjustment
• Zero point adjustment
• DAC output adjustment
• Transfer function
• Self-compensation
Self-Diagnostics and Others
• CPU & Analog Module Fault Detection
• Communication error
• Fail-mode handling
• LCD indication
• Temperature measurement of sensor module
Process Connection via Diaphragm Seals
For connecting the model PAS to different process
connections, diverse diaphragm seal versions are necessary.
They can be connected to the pressure transmitter directly or
via a capillary tube. Depending on the application; different
combinations of diaphragm seals, capillary tubes and fill
fluids are possible. To clarify those possibilities, the special
connections via diaphragm seals should be requested
separately from the pressure transmitter.
No responsibility taken for errors;
subject to change without prior notice.
www.koboldusa.com
3
Heavy Duty Pressure Transmitter Model PAS
Technical Details
Measuring Principle: Piezoresistive Sensor
Measuring Span: -14.5…21.7 PSIG up to 0…8700
(Depending on instrument version),
zero and span values can be set
anywhere within the range limits.
Span must be greater than or
equal to the minimum span.
Accuracy: 0.075 % of calibrated span
Process Temperature: -40...248 °F
(Approval codes may effect limits.
Max. ambient temperature at
LCD = 176 °F.)
(Valid for stand-alone unit only, without assembled
diaphragm seals.)
Model G -14.5...43.5 PSIG (for Range 3)
-14.5...435 PSIG (for Range 4)
0...1552.5 PSIG (for Range 5)
0...5800 PSIG (for Range 6)
0...10875 PSIG (for Range 7)
Model A 0...72.5 PSIG (for Range 4)
0...435 PSIG (for Range 5)
0...754 PSIG (for Range 6)
Maximum Load: 250 Ω at 17.5 V
550 Ω at 24 V
Max. loop resistance =
DC
DC
(U - 12 VDC)
0.022 A
Electrical Connection: ½" NPT conduit with M4
screw terminals,
G ½ conduit with M4 screw
terminals
Output:Two wire 4…20 mA, user-configurable for linear output,
digital process value superimposed
on 4…20 mA signal, available
to any host that conforms to the
HART® protocol
Update Time: 0.12 seconds
Turn-On Time: 3 seconds
Protection: IP 67 for standard (code S)
Weight: 3.8 lbs (excluding options)
6.3 lbs (st. steel housing option)
Failure Mode: Fail high: current ≥ 21.1 mA
Fail low: current ≤ 3.78 mA
EMC Conformity
Standards: EMI (emission) - EN 50081-2:1993
Process Connections: ½" NPT female
Mounting Position: Upright
Display: 5 Digit LCD
Power Supply: 12 … 45 VDC -operation
17.5 … 45 VDC -HART®
communications
Technical Data for Version with 50 mm Extended
Diaphragm
(Model PAS-P, Engineered for the Paper/Pulp Industry)
Application:Level and gauge pressure
measurement
Accuracy: ± 0.2% of calibrated span @ 68 °F
Long Term Stability: Application dependent, typically
± 0.125% of URL / 1 year
Process Temperature: 68...95 °F
Ambient Temperature: 68...95 °F
Materials:
O-ring: FKM
Extended Sleeve:304 Stainless Steel
Process Connection: 316-Ti / 316 Stainless Steel
Other Specifications: Same as standard models
No responsibility taken for errors;
4
www.koboldusa.com
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
Order Details (Example: PAS- G EE 3 S 4 N S0 0):
ModelVersion
..G.. = Gauge Pressure
PAS-
..A.. = Absolute Pressure
..EE.. = 316L st. st. / 316 st. steel
Order Details Continued:
Material
Diaphragm/Other
Measuring RangeMeasuring Span
for PAS-G
..3.. = -14.5...21.7 PSIG
..4.. = -14.5...217 PSIG
..5.. = 0...725 PSIG
..6.. = 0...3625 PSIG
..7.. = 0...8700 PSIG
6 W.C....36.3 PSIG
60 W.C....232 PSIG
200 W.C....725 PSIG
36.3 PSIG...3625 PSIG
87 PSIG...8700 PSIG
for PAS-A
..4.. = 0...36 PSIA
..5.. = 0...217 PSIA
..6.. = 0...362 PSIA
10 W.C....36.3 PSIA
60 W.C....217 PSIA
100 W.C....362 PSIA
Fill Liquid
Process
Connection
Electrical
Connection
ApprovalsOptions
..0 =without
..N.. =½" NPT epoxy-
polyester painted
aluminium
..S.. = silicone ..4.. = ½" NPT female
..G.. =G ½ epoxy-
polyester painted
aluminium
1)
Diaphragm seal model and application data to be clearly specified. The application Index on page 17-18 must be completed.
For summary of diaphragm seal models and possible ranges, see page 9 onwards. For dimensional details see DRM data sheet.
..S0.. = standard
(waterproof IP 67)
..F0.. = ATEX, flameproof,
Ex d
..E =oil free finish
..M = housing in stainless steel
..N1) = mounting of PAS onto
diaphragm seal
Order Details Mounting Brackets:
DescriptionOrder Number
Angle type bracket for PAD/PAS
vertical pipe mounting for PAS
vertical pipe mounting for PAD
incl. U-Clamp for 2“ pipe mounting bracket and 2 x mounting nuts/ washers
incl. 4 x mounting screws for PAS
incl. 4 x mounting screws for PAD
Flat type bracket for PAD/PAS
horizontal pipe mounting for PAS
vertical pipe mounting for PAD
incl. U-Clamp for 2“ pipe mounting bracket and mounting nuts/ washers
incl. 4 x mounting bolts and washers for PAS
incl. 4 x mounting bolts for PAD
ZUB-PAD/PAS-K
ZUB-PAD/PAS-L
Order Details Manifold Valve:
DescriptionOrder Number
2-way Manifold Valve, Direct Mount, Machined
No responsibility taken for errors;
subject to change without prior notice.
www.koboldusa.com
V-2003CDADABAA
5
Heavy Duty Pressure Transmitter Model PAS
Order Details for PAS-..P Extended Diaphragm Version for Paper/Pulp Industries (Example: PAS-P ES 3 S A N S 0 0)
Model
PAS-P..
..ES.. = 316 SS / 304 SS,
316L SS, 316-Ti SS
MaterialMeasuring Ranges
Diaphragm/OtherCodeMeasuring RangeMeasuring Span
..3..-10,000 mm H2O...15,000 mm H2O150 mm H2O...15,000 mm H2O
..4..-10,000 mm H2O...150 m H2O1,500 mm H2O...150 m H2O
50 mm (2")/
100 mm (4")/
150 mm (6")/
200 mm (8")/
(customer
specified)
4.41"
No responsibility taken for errors;
10
www.koboldusa.com
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly)
(Standard device without additional options (e.g. coatings, special materials etc.).
For dimensions/technical data, see DRM data sheet. Accuracy: 0.075% of calibrated span + influence of seal).
Over and under ranges of the min./max. span may be possible, but must be verified by KOBOLD for each application.
The indicated min./max. spans do not consider any coating of the diaphragm seals. For additional information contact
KOBOLD.
Model DRMSize CodeSizeNoteØ Diaphragm
DRM-189
Max. Media
Temperature
Min. Span
(PSIG)
Max. Span
(PSIG)
DRM-600
DRM-601
F23Ø 18
R15G ½
R20G ¾Ø 23.80 ... 23.2*14500
R25G 1Ø 29.50 ...14.58700
R32G 1 ¼Ø 380 ... 8.78700
R40G 1 ½Ø 400 ... 8.78700
N15½" NPTØ 18
N20¾" NPTØ 18
N251" NPTØ 23.80 ... 23.28700
N321 ¼" NPTØ 34.50 ... 14.58700
M20M20 x 1.5Ø 180 ... 588700
M48M 48 x 3Ø 400 ...8.78700
R15G ½
R20G ¾Ø 23.80 ... 23.2*14500
R25G 1Ø 29.50 ...14.58700
R32G 1 ¼Ø 380 ... 8.78700
R40G 1 ½Ø 400 ... 8.78700
N15½" NPTØ 18
N20¾" NPTØ 18
N251" NPTØ 23.80 ... 23.28700
N321 ¼" NPTØ 34.50 ... 14.58700
M20M20 x 1,5Ø 180 ... 588700
M48M 48 x 3Ø 400 ...8.78700
For homogenizing machines,
direct
Fixed male thread, direct
Fixed male thread with
capillary
Ø 18248 °F0 ... 5814500
Ø 18
212 °F
Ø 18
392 °F
0 ... 58*14500
0 ... 58*
0 ...58*
0 ... 58*14500
0 ... 58*
0 ... 58*
14500
14500
14500
14500
DRM-602
DIN 11851
* Consult Factory for Minimum Span per Customer Application
No responsibility taken for errors;
subject to change without prior notice.
R20DN 20
R25DN 25
R32DN 32
R40DN 40
R50DN 50
R65DN 65
R80DN 80
R1HDN 100
Dairy connection, direct
Ø 18
Ø 23.80 ... 23.2
Ø 29.50 ...14.5
Ø 380 ... 8.7
Ø 45.5
Ø 64
Ø 64
Ø 64
www.koboldusa.com
212 °F
0 ...58
0 ... 5.8362.5
0 ... 3.6362.5
0 ... 3.6362.5
0 ... 3.6362.5
580
580
580
580
11
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly)
Model DRMSize CodeSizeNoteØ Diaphragm
DRM-603
DIN 11851
R20DN 20
R25DN 25
R32DN 32
R40DN 40
R50DN 50
R65DN 65
R80DN 80
R1HDN 100
Dairy connection, capillary
Ø 18
Ø 23.80 ... 23.2
Ø 29.50 ... 14.5
Ø 380 ...8.7
Ø 45.50 ... 5.8
Ø 64
Ø 64
Ø 64
Max. Media
Temperature
392 °F
Min. Span
(PSIG)
0 ... 58
Max. Span
(PSIG)
580
580
580
580
362.5
0 ... 3.6362.5
0 ... 3.6362.5
0 ...3.6362.5
DRM-604
IDF
DRM-605
IDF
DRM-606
DRM-607
DRM-607/1
R251"
R401 ½"Ø 420 ... 14.5580
IDF socket with union nut,
direct
Ø 29.5
0 ... 23.2580
212 °F
R502"Ø 560 ... 8.7580
R251"
R401 ½"Ø 420 ... 8.7580
IDF socket with union nut,
capillary
Ø 29.5
0 ... 14.5580
392 °F
R502"Ø 560 ... 5.8580
R20G ¾
Capsule seal with rotable
male, capillary
short capsule662 °F
0 ... 878700
R28M 28 x 1.50 ... 878700
R15G ½
Capsule seal with fixed male,
direct
long capsule
0 ... 14.58700
R20G ¾0 ... 14.58700
212 °F
R15G ¾
Capsule seal with fixed male,
direct
long capsule
0 ... 14.58700
R20G 10 ... 14.58700
12
DRM-608/1
DRM-610
SMS
R20G ¾
Capsule seal with union nut,
capillary
long capsule
0 ... 14.58700
662 °F
R25G 1
R401 ½"
Capsule seal with union nut,
capillary
SMS socket with union nut,
direct
long capsule0 ... 14.58700
Ø 34.5
0 ... 14.5580
212 °F
R502"Ø 45.50 ... 5.8580
www.koboldusa.com
subject to change without prior notice.
No responsibility taken for errors;
Heavy Duty Pressure Transmitter Model PAS
Diaphragm Seal Models (Direct or Remote Assembly)
Model DRMSize CodeSizeNoteØ Diaphragm
DRM-611
SMS
R401 ½"
SMS socket with union nut,
capillary
R502"Ø 45.50 ... 5.8580
Ø 34.5
Max. Media
Temperature
392 °F
Min. Span
Max. Span
(PSIG)
0 ... 1.4580
(PSIG)
DRM-612
Clamp
DRM-613
Clamp
DRM-614
APV-RJT
R251"
Ø 18
0 ...58232
F401 ½"Ø 35.50 ...14.5232
F502"Ø 45.50 ...5.8232
Tri-Clamp, direct
212 °F
R652 ½"Ø 520 ...5.8232
R803"Ø 640 ...3.6145
R251"
Ø 18
0 ...58232
F401 ½"Ø 35.50 ...14.5232
F502"Ø 45.50 ...5.8232
Tri-Clamp, capillary
392 °F
R652 ½"Ø 520 ...5.8232
R803"Ø 640 ...3.6145
R201"
R401 ½"Ø 42.50 ... 8.71450
Union-nut, direct
Ø 29.5
0 ... 23.21450
212 °F
R502"Ø 560 ... 5.81450
DRM-615
APV-RJT
R201"
R401 ½"Ø 42.50 ...8.71450
R502"Ø 560 ... 5.81450
DRM-616
R45M 45 x 2Union-nut, directØ 23.8212 °F0 ... 23.223200
DRM-617
R45M 45 x 2Union-nut, capillaryØ 23.8248 °F0 ... 23.223200
No responsibility taken for errors;
subject to change without prior notice.