Kobold Model Specifications

Heavy Duty
Pressure Transmitter
measuring
monitoring
analyzing
PAS
Span: -14.5 … 21.7 PSIG up to 0…8700 PSIG
t
: 248 °F
max
Process Connection: ½" NPT, or
Various Diaphragm Seals on Request
Material: 316L Stainless Steel
Output: 4 ... 20 mA
Sensor Input: Gauge or Absolute Pressure
Self-Diagnostic Function: Sensor, Memory A/D
Converter, Power etc.
Digital Communication with HART
KOBOLD companies worldwide:
ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECH REPUBLIC, EGYPT, FRANCE, GERMANY, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, REPUBLIC OF KOREA, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, UNITED KINGDOM, USA, VIETNAM
01/12- 2016
®
Protocol
KOBOLD Instruments, Inc. 1801 Parkway View Drive Pittsburgh, PA 15205
Main Ofce:
1.412.788.2830
1.412.788.4890 info@koboldusa.com www.koboldusa.com
Heavy Duty Pressure Transmitter Model PAS
Description
The KOBOLD Pressure Transmitter model PAS is a microprocessor based high performance transmitter, which has a scalable pressure calibration and output signal. It automatically compensates for ambient temperature and process variables. Communication with the instrument and configuration of various parameters is possible via HART® protocol. All of the sensor's data is input, modified and stored via EEPROM.
Features
Superior Performance
●O High Reference Accuracy:
±0.075 % of Calibrated Span
●O Long-term Stability
●O High Rangeability (100 : 1)
Flexibility
●O Data configuration with HART
●O Measurement of gauge or absolute pressure
®
configurator
Reliability
●O Continuous self-diagnostic function
●O Automatic ambient temperature compensation
●O EEPROM write-protection
●O Fail-mode process function
Transmitter Description
Electronics Module
The Electronics module consists of a circuit board sealed in an enclosure. There is an MCU module, an analog module, an LCD module, and a terminal module within the transmitter. The MCU module acquires the digital value from the analog module and applies correction coefficients selected from EEPROM. The output section of the MCU module converts the digital signal to a 4…20 mA output. The MCU module communicates with the HART®-based configurator or control system, such as DCS (Distributed Control System). The power section of the MCU module has a DC-to-DC power conversion circuit and an input/output isolation circuit. The LCD module plugs into the MCU module and displays the digital output in a user configured unit.
Sensor Inputs
The pressure transmitter model PAS is available as a piezo­resistive pressure transmitter which measures gauge pressure as well as absolute pressure. The sensor module converts the resistance into a digital value. The MCU module calculates the process pressure based on this digital value.
Functional Block Diagram
Sensor Part
A/D-Conversion
EEPROM
Piezoelectric sensor
• Gauge pressure
• Absolute pressure
2
www.koboldusa.com
MCU Part
Microprocessor
· Input Sensor Value
· Engineering Units
· Re–range (Zero / Span)
· Zero Point Adjustment
· DA Trimming
· Damping / Filtering
·
LCD Engineering Mode
· Diagnostics
· Self Compensation
· Communications
· LCD Display
· Configuration Data
4~20mA
DAC
®
HART
HART® Protocol with Host
No responsibility taken for errors;
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
The sensor modules include the following features:
• The software of the transmitter compensates for thermal effects, improving performance.
• Precise Input Compensation during operation is achieved with temperature and pressure correction coefficients that are characterized over the range of the transmitter and stored in the sensor module's EEPROM memory.
• EEPROM stores sensor information and correction coefficients separately from the MCU module, allowing for easy repair, reconfiguration and replacement.
Basic Setups
The following settings can be easily configured from any host that can support HART® protocol:
• Operational parameters
• 4 … 20 mA (zero points/span)
• Engineering units
• Damping time: 0.25…60 sec.
• Tag: 8 alphanumeric characters
• Descriptor: 16 characters
• Message: 32 characters
• Date: day/month/year
Calibration and Adjustment
• Lower/Upper range (zero/span)
• Sensor zero adjustment
• Zero point adjustment
• DAC output adjustment
• Transfer function
• Self-compensation
Self-Diagnostics and Others
• CPU & Analog Module Fault Detection
• Communication error
• Fail-mode handling
• LCD indication
• Temperature measurement of sensor module
Process Connection via Diaphragm Seals
For connecting the model PAS to different process connections, diverse diaphragm seal versions are necessary. They can be connected to the pressure transmitter directly or via a capillary tube. Depending on the application; different combinations of diaphragm seals, capillary tubes and fill fluids are possible. To clarify those possibilities, the special connections via diaphragm seals should be requested separately from the pressure transmitter.
No responsibility taken for errors; subject to change without prior notice.
www.koboldusa.com
3
Heavy Duty Pressure Transmitter Model PAS
Technical Details
Measuring Principle: Piezoresistive Sensor Measuring Span: -14.5…21.7 PSIG up to 0…8700
(Depending on instrument version), zero and span values can be set anywhere within the range limits. Span must be greater than or equal to the minimum span.
Accuracy: 0.075 % of calibrated span Process Temperature: -40...248 °F
(Approval codes may effect limits. Max. ambient temperature at LCD = 176 °F.)
Ambient Temperature: -22…176 °F Storage Temperature: -40…185 °F
(Non-condensing)
Humidity Limit: 5 %...98 % RH
Pressure Limits (with Silicone Oil)
(Valid for stand-alone unit only, without assembled diaphragm seals.)
Model G -14.5...43.5 PSIG (for Range 3)
-14.5...435 PSIG (for Range 4)
0...1552.5 PSIG (for Range 5)
0...5800 PSIG (for Range 6)
0...10875 PSIG (for Range 7)
Model A 0...72.5 PSIG (for Range 4)
0...435 PSIG (for Range 5)
0...754 PSIG (for Range 6)
Maximum Load: 250 Ω at 17.5 V
550 Ω at 24 V
Max. loop resistance =
DC
DC
(U - 12 VDC)
0.022 A
Electrical Connection: ½" NPT conduit with M4
screw terminals, G ½ conduit with M4 screw terminals
Output: Two wire 4…20 mA, user-configurable for linear output, digital process value superimposed on 4…20 mA signal, available to any host that conforms to the HART® protocol
Update Time: 0.12 seconds Turn-On Time: 3 seconds Protection: IP 67 for standard (code S) Weight: 3.8 lbs (excluding options)
6.3 lbs (st. steel housing option) Failure Mode: Fail high: current ≥ 21.1 mA
Fail low: current ≤ 3.78 mA
EMC Conformity Standards: EMI (emission) - EN 50081-2:1993
EMS (immunity) - EN 50082-2:1995
ATEX Approval (Option): II 2G Exd IIC T6...T4
Wetted Materials Isolating Diaphragms: 316L Stainless Steel
Connection Thread: 316 Stainless Steel
Non-wetted Materials Fill Fluid: Silicone oil
Electronics Housing: Aluminum, flameproof (Ex d) and waterproof (lP 67), 316 L SS (option)
Cover O-ring: NBR Paint: Epoxy-polyester or polyurethane Mounting Bracket: 2-inch pipe, 304 SS, painted
carbon steel with 304 SS U-bolt
Nameplate: 304 Stainless steel
Process Connections: ½" NPT female Mounting Position: Upright Display: 5 Digit LCD Power Supply: 12 … 45 VDC -operation
17.5 … 45 VDC -HART®
communications
Technical Data for Version with 50 mm Extended Diaphragm
(Model PAS-P, Engineered for the Paper/Pulp Industry)
Application: Level and gauge pressure measurement
Accuracy: ± 0.2% of calibrated span @ 68 °F
Long Term Stability: Application dependent, typically
± 0.125% of URL / 1 year
Process Temperature: 68...95 °F
Ambient Temperature: 68...95 °F
Materials:
O-ring: FKM
Extended Sleeve: 304 Stainless Steel
Process Connection: 316-Ti / 316 Stainless Steel
Other Specifications: Same as standard models
No responsibility taken for errors;
4
www.koboldusa.com
subject to change without prior notice.
Heavy Duty Pressure Transmitter Model PAS
Order Details (Example: PAS- G EE 3 S 4 N S0 0):
Model Version
..G.. = Gauge Pressure
PAS-
..A.. = Absolute Pressure
..EE.. = 316L st. st. / 316 st. steel
Order Details Continued:
Material
Diaphragm/Other
Measuring Range Measuring Span
for PAS-G
..3.. = -14.5...21.7 PSIG
..4.. = -14.5...217 PSIG
..5.. = 0...725 PSIG
..6.. = 0...3625 PSIG
..7.. = 0...8700 PSIG
6 W.C....36.3 PSIG
60 W.C....232 PSIG
200 W.C....725 PSIG
36.3 PSIG...3625 PSIG
87 PSIG...8700 PSIG
for PAS-A
..4.. = 0...36 PSIA
..5.. = 0...217 PSIA
..6.. = 0...362 PSIA
10 W.C....36.3 PSIA
60 W.C....217 PSIA
100 W.C....362 PSIA
Fill Liquid
Process
Connection
Electrical
Connection
Approvals Options
..0 = without
..N.. = ½" NPT epoxy-
polyester painted aluminium
..S.. = silicone ..4.. = ½" NPT female
..G.. = G ½ epoxy-
polyester painted aluminium
1)
Diaphragm seal model and application data to be clearly specified. The application Index on page 17-18 must be completed.
For summary of diaphragm seal models and possible ranges, see page 9 onwards. For dimensional details see DRM data sheet.
..S0.. = standard
(waterproof IP 67)
..F0.. = ATEX, flameproof,
Ex d
..E = oil free finish
..M = housing in stainless steel
..N1) = mounting of PAS onto
diaphragm seal
Order Details Mounting Brackets:
Description Order Number
Angle type bracket for PAD/PAS vertical pipe mounting for PAS vertical pipe mounting for PAD incl. U-Clamp for 2“ pipe mounting bracket and 2 x mounting nuts/ washers incl. 4 x mounting screws for PAS incl. 4 x mounting screws for PAD
Flat type bracket for PAD/PAS horizontal pipe mounting for PAS vertical pipe mounting for PAD incl. U-Clamp for 2“ pipe mounting bracket and mounting nuts/ washers incl. 4 x mounting bolts and washers for PAS incl. 4 x mounting bolts for PAD
ZUB-PAD/PAS-K
ZUB-PAD/PAS-L
Order Details Manifold Valve:
Description Order Number
2-way Manifold Valve, Direct Mount, Machined
No responsibility taken for errors; subject to change without prior notice.
www.koboldusa.com
V-2003CDADABAA
5
Heavy Duty Pressure Transmitter Model PAS
Order Details for PAS-..P Extended Diaphragm Version for Paper/Pulp Industries (Example: PAS-P ES 3 S A N S 0 0)
Model
PAS-P..
..ES.. = 316 SS / 304 SS,
316L SS, 316-Ti SS
Material Measuring Ranges
Diaphragm/Other Code Measuring Range Measuring Span
..3.. -10,000 mm H2O...15,000 mm H2O 150 mm H2O...15,000 mm H2O
..4.. -10,000 mm H2O...150 m H2O 1,500 mm H2O...150 m H2O
Order Details Continued
Filling Liquid Process Connection Electrical Connection Approval Manifold Valve Options
..N.. = 1" Class 150 RF
..P.. = 1-1/4" Class 150 RF
..S.. = Silicone
..Q.. = 1-1/2" Class 150 RF
..R.. = 2" Class 150 RF
..S.. = 2-1/2" Class 150 RF
..T.. = 3" Class 150 RF
..U.. = 4" Class 150 RF
..V.. = 5" Class 150 RF
..W.. = 6" Class 150 RF
..N.. = 1/2" NPT epoxy-polyester
painted aluminum
..G.. = 1/2" epoxy-polyester painted aluminum
..S.. = without, standard, (waterproof IP 67)
..0.. = without ..0 = without
No responsibility taken for errors;
6
www.koboldusa.com
subject to change without prior notice.
Dimensions
86
LOCK
LOCK
FIELD
TERMINALS
s
73 39
112
160.5
-
N
E
I
V
I
L
S
O
P
A
M
T
O
E
X
R
E
H
E
S
P
AF 30
32.5
M6X1 DP9
4PLS
LOCK
LOCK
FIELD
TERMINALS
s
73 39
112
160.5
IN
Drain
IN
Drain
148
Ø
30
VENT.
IS
O
L
A
T
E
Standard Model
Heavy Duty Pressure Transmitter Model PAS
3.39"
I
T
O
U
N
A
-
C
-
I
D
E
Z
I
G
R
E
N
E
E
L
I
H
W
N
E
P
O
N
E
X
P
L
O
S
I
V
E
A
T
M
O
S
P
H
E
R
E
T
D
O
O
N
32.5
1.28"
4.41"
112
2.87" 1.54"
73 39
s
TERMINALS
LOCK
LOCK
FIELD
160.5
6.32"
AF 30
2-way Manifold Valve: (Direct Mount, Machined) V-2003CDADABAA (PTFE Packing)
(Inlet: ½" NPT Female / Outlet: ½" NPT Male)
Technical Details Material: AISI 316L Pressure Rating: 6 000 psi Temperature Range: -99...410 °F (PTFE Packing), Standard
-65... 950 °F (GRAPHOIL Packing), On Request Weight: 1.94 lbs
VENT.
Drain
IN
5.83"
148
Included Accessories: Plug
No responsibility taken for errors; subject to change without prior notice.
IS
O
A
L
E
T
30
1.18"
Ø
4.73"
120
OUT IN
Drain 1/4" NPT-F
with plug
www.koboldusa.com
7
Loading...
+ 16 hidden pages