Electromagnetic Flowmeter
Compact, All-Metal Design
measuring
•
monitoring
•
analyzing
MIM
•• For Measurement and
Monitoring of Conductive Liquids
•• Flow and Temperature
Measurement
•• Switching, Transmitting, and
Batching Functions
•• Bi-directional Flow Measurement
•• Rugged Stainless Steel
Construction
•• p
: 230 PSI; t
max
: 284 °F
max
•• Accuracy: < ± (0.8% of Reading
+ 0.5% of Full Scale)
-ve +ve
9
0
°
r
o
t
a
t
i
o
n
p
r
o
g
r
a
m
m
a
b
l
e
t
a
t
o
r
°
0
9
e
l
b
a
m
m
a
r
g
o
r
p
n
o
i
KOBOLD companies worldwide:
ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA,
CZECH REPUBLIC, EGYPT, FRANCE, GERMANY, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA,
MEXICO, NETHERLANDS, PERU, POLAND, REPUBLIC OF KOREA, ROMANIA, SINGAPORE, SPAIN,
SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, UNITED KINGDOM, USA, VIETNAM
05/07-17-2019
KOBOLD Instruments, Inc.
1801 Parkway View Drive
Pittsburgh, PA 15205
Main Ofce:
1.800.998.1020
1.412.788.4890
info@koboldusa.com
www.koboldusa.com
All-Metal Electromagnetic Flowmeter Model MIM
Description
The new MIM electromagnetic flowmeter measures and monitors
small to medium sized flow of conductive liquids in pipes. According
to Faraday’s Law of magnetic induction, a voltage is induced in a
conductor moving through a magnetic field. The electrically conductive
measured media acts as the conductor. The voltage induced in the
measured media is proportional to the flow velocity and is therefore
a value for the volumetric flow. The induced voltage is detected by
two sensing electrodes which are in contact with the measuring media
and sent to an integrated amplifier. The flow rate will be calculated
based on the cross sectional area of the pipe. The measurement does
not depend on the process liquid and its properties such as density,
viscosity and temperature. The two outputs can be independently set to
switch, or provide an analog or frequency output. A batching function
can also be selected, where output 1 is set to switch as NPN / PNP / PP
and output 2 is set as the control input.
Features
•• Rugged Stainless Steel Construction
•• Flow and Temperature Measurement
•• Switching, Transmitting, and Batching Functions
•• Batching Function with External Control Input
•• Bi-directional Flow Measurement
•• Colored, Multi-parameter, Configurable TFT Display, Rotatable
in 90° Increments
•• Intuitive Setup Menu via 4 Optical Touch Keys
•• 2 Configurable Outputs (Pulse/Frequency/Alarm/Analog Output)
•• Grand and Resettable Totalizer
Technical Details
Measurement Principle: Electromagnetic
Ranges: 0.48...48 GPH to 0.8...200 GPM
Media: Conductive Liquids
Min. Conductivity: ≥ 20 µS/cm
Max. Media Viscosity: 70 cSt
Native Fittings: G 1/2...G 2, or 2" NPT
Optional Fitting Kits: 1/4"...3/4" NPT (Male or Female),
1" or 2" Tri-Clamp
®
(All Kits Include 2x KlingerSIL Gaskets)
Max. Pressure: 230 PSI
Accuracy1): < ± (0.8% of Reading + 0.5% of Full
Scale)
Repeatability: ± 0.2% of Full Scale
Temperature Sensor: PT10002)
Response Time Flow t90
(Alarm Output /
Pulse Output): < 250 ms
Response Time
Temp. t90 (Signal Output): < 20 s
Mounting Position: Universal
Programming: Via 4 Optical Touch Fields,
1)
Reference Conditions: Media: 60...85 °F, 1 cSt, 500 µS/cm, 15 PSI
Ambient: 60...85 °F
2
) PT1000 range: -22...212 °F (not actual MIM media temperature range)
2
Can be used with Gloves
www.koboldusa.com
Pressure Drop: See Pressure Loss Diagram
Straight Piping
Requirement: 3 x Upstream, 2 x Downstream
Housing: 316L Stainless Steel,
PMMA Display Screen
Wetted Parts
Fitting/Housing: 316L Stainless Steel
Insulation Parts: PEEK
Electrodes: 316L Stainless Steel
Seals: FKM or EPDM
Fitting Adapter: 316L Stainless Steel
Media Temperature: -4...158 °F (Compact)
-4...185 °F (Remote, PVC Cable)
-4...284 °F (Remote, ETFE Cable)
Ambient Temperature: -4...140 °F (Compact Version and
Display for Remote Version)
-4...284 °F (Sensor for Remote
Version with ETFE Cable)
-4...185 °F (Sensor for Remote
Version with PVC Cable)
Electrical Data
Supply Voltage: 19 - 30 VDC, Internal Power
Consumption max. 200 mA
Display: TFT Display, 128 x 128 Pixels,
1.4" Display, Orientation Adjustable
in 90° Increments
Display Repetition Rate: 0.5 ... 10 s, Adjustable
Electrical Connection: M12x1, 4-pin
Pulse Output: Push-Pull, Freely Scalable,
Configurable for Partial and
Accumulated Totalizer
Frequency Output: Push-Pull, Fully Scalable,
2 kHz @ Overflow
50...1000 Hz at Full Scale,
User Programmable
Alarm Output: NPN, PNP, Push-Pull,
Configurable Max. 30 VDC,
Max. 200 mA Short-Circuit Proof
Analog Output: Active, 3-wire, 4-20 mA,
Max. Load 500 Ω or 0-10 VDC,
(Ri = 500 Ω)
Control Input: Active Signal U
0<Low<10 VDC, 15VDC<High<V
Max. 30 V
high
,
DC
S
Protection: IP 67
No responsibility taken for errors;
subject to change without prior notice.
All-Metal Electromagnetic Flowmeter Model MIM
Technical Details (continued)
Batching Function: Batching Output OUT2:
Push-Pull, High Active
Control Input OUT1:
START/STOP 0.5s <t
RESET t
high
>5s
high
Shock Resistance
DIN EN 60068-2-27:2010: 20 g (11 ms)
Vibration Resistance
DIN EN 60068-2-6:2008: 5 g (10 … 2000 Hz)
Environmental Testing
DIN EN 60068-2-30:2006: Severity Level b
<4s
IO-Link Specification
Manufacturer ID: 1105 (Decimal), 0 x 0451 (Hex)
Manufacturer Name: Kobold Messring GmbH
IO-Link Specification: V1.1
Bitrate: COM3
Minimal Cycle Time: 1.1 ms
SIO-Mode: Yes (OUT1 in Configuration IO-Link)
Block Parameterisation: Yes
Operational Readiness: 10 s
Max. Cable Length: 20 m
Order Details (Example: MIM-12 05G G4 C3T0)
Model Measuring Range
..03G.. = 0.48...48 GPH
..03H.. = 30...3000 ml/min
..05G.. = 0.01...2.6 GPM
..05H.. = 0.04...10 LPM
..10G.. = 0.025...6.6 GPM
MIM-12.. = SS Housing
SS Electrodes
FKM Seals
MIM-13.. = SS Housing
SS Electrodes
EPDM Seals
..10H.. = 0.1...25 LPM
..15G.. = 0.05...13 GPM
..15H.. = 0.2...50 LPM
..15G.. = 0.05...13 GPM
..15H.. = 0.2...50 LPM
..20G.. = 0.1...26 GPM
..20H.. = 0.4....100 LPM
..35G.. = 0.4...100 GPM ..N9.. = 2" NPT Female
..35H.. = 1.5...350 LPM ..G9.. = G 2 Male
..40G.. = 0.8...200 GPM ..N9.. = 2" NPT Female
..40H.. = 3...750 LPM ..G9.. = G 2 Male
Accessories: P/N 807.037 = 4-Pin Micro-DC Connector with 6-foot Cable
P/N 807.037/5M = 4-Pin Micro-DC Connector with 16-foot Cable
P/N 807.037/10M = 4-Pin Micro-DC Connector with 32-foot Cable
1)
Temperature units of measure factory programmed; °C for LPM models and °F for GPM/GPH models
2)
Order code substitution for longer cables: 020 = 2 m (6 ft), 050 = 5 m (16 ft), 100 = 10 m (32 ft), 150 = 15 m (49 ft), 200 = 20 m (65 ft).
Wall mounting brackets (brackets incl. accessories) are included in the scope of delivery.
1)
Native Connection Electronics
..G4.. = G 1/2 Male
..C3T0.. = Compact TFT Display
..G5.. = G 3/4 Male
..P0202).. = Remote Display Version, TFT Display,
..G6.. = G 1 Male
..E0202).. = Remote Display Version, TFT Display,
2x Configurable Outputs (Current/
Voltage/Pulse/Frequency/Alarm)
M12x1 Electrical Connection
2m PVC Cable, Max. 185 °F
2m ETFE Cable, Max. 284 °F
Electrical Connection MIM-..C3T
OUT 2
1
2
4
3
OUT 1
No responsibility taken for errors;
subject to change without prior notice.
Configuration of Outputs
Output 1 (OUT1, PIN 4) Output 2 (OUT2, PIN 2)
Analog Output 0-10 V
DC
Analog Output 4-20 mA Analog Output 4-20 mA
Switching Output NPN/PNP/PP Switching Output NPN/PNP/PP
Pulse Output PP Pulse Output PP
Frequency Output PP Frequency Output PP
Communication Mode KofiCom
Communication Mode IO-Link
Control Input
Control Input Start/Stop/Reset Batching Function Batching Function Switch/PP
www.koboldusa.com
Analog Output 0-10 V
DC
3