11. Maintenance
In case, the medium to be measured is not polluted, the unit is maintenance-free.
12. Technical Information
Nominal size: 74 mm
Accuracy class 0,5 %
Display: 4-digit LCD; digit height 12,7 mm
Measuring range: -1...0, 0...1, 0...1.6, 0...2.5, 0...4, 0...6, 0...10,
0...16, 0...25, 0...40, 0...60, 0...100, 0...160,
0...250, 0...400 bar
Overload range: 3 x P
N
(up to 40 bar)
2 x P
N
(60 to 160 bar)
1,5 x PN (from 250 bar)
Power supply: 9 VDC (block battery, IEC 6 LR 01)
Service-life at conversion rate 5/s: 5000 h (block battery 600mAh),
10000 h (Lithium block battery 1200 mAh)
Conversion rate: 5 per sec. (standard)
(1 to 10 per sec. factory-adjustable)
Automatic switch-off times: 2 ...... 90 min, only factory-adjustable
(auto off) (not recommended with analogue or switching
output), 0 = inactive
Zero point correction: ≤ ± 25 %
Parts in contact with medium: st. steel 1.4571, ceramic, NBR (Buna-N)
Connection: G ¼ A
(other connection on request)
Medium temperature: -30...+85 °C
Ambient temperature: 0...+60 °C
Storage temperature: -30...+80 °C
Permissible relative humidity: <90%, not condensing
Protection cat.: IP 65
Limit-value relay (Option): N/O, bistable
adjustable setpoint and hysteresis
Max. switching power: 30 V
AC/DC
, 2 A (for relay output)
Analogue output (Option): 0 - 2 V
DC
Load: ≥ 100 kΩ
Electrical connection M 12 x 1 plug DIN (female connector as
accessorie available)
Total cable length: max. 3 metres
Peak value memory (option): MIN or MAX value,
resetting via keypad