Kobold KSK Operating Instructions Manual

Page 1
Operating Instructions
for
Plastic Flow Meter
Model: KSK
Page 2
KSK
1. Contents
1.Contents ........................................................................................................ 2
2.Note .............................................................................................................. 3
3.Instrument Inspection .................................................................................... 3
4.Regulation Use .............................................................................................. 3
5.Operating Principle ........................................................................................ 4
6.Mechanical Connection ................................................................................. 4
7.Electrical Connection .................................................................................... 5
7.1.Reed Contact, bistable (option) ........................................................... 5
7.2.Electronic Contact (option) ................................................................... 6
8.Operation ...................................................................................................... 7
9.Maintenance ................................................................................................. 7
10.Technical Information .................................................................................... 8
11.Order Codes ............................................................................................... 10
12.Dimensions ................................................................................................. 11
13.EU Declaration of Conformance .................................................................. 12
Manufactured and sold by:
Kobold Messring GmbH
Nordring 22-24
D-65719 Hofheim
Tel.: +49(0)6192-2990
Fax: +49(0)6192-23398
E-Mail: info.de@kobold.com
Internet: www.kobold.com
Page 3
KSK
KSK K03/0316 page 3
2. Note
Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents.
When used in machines, the measuring unit should be used only when the machines fulfil the EC-machine guidelines.
as per PED 2014/68/EU
In acc. with Article 4 Paragraph (3), "Sound Engineering Practice", of the PED 2014/68/EU no CE mark. Diagram 6, Pipe, Group 1 dangerous fluids
3. Instrument Inspection
Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / forwarding agent immediately, since they are responsible for damages during transit.
Scope of delivery:
The standard delivery includes:
Plastic Flow Meter model: KSK Operating Instructions
4. Regulation Use
Any use of the Plastic Flow Meter, model: KSK, which exceeds the manufacturer’s specification, may invalidate its warranty. Therefore any resulting damage is not the responsibility of the manufacturer. The user assumes all risk for such usage.
Page 4
KSK
5. Operating Principle
Kobold Plastic Flow Meters and Switches, model KSK, are based on the well known suspended float principle. They are used for measuring and monitoring flows in closed pipes. The media flows, from below, through a conical plastic measuring tube. This raises the float and the flow rate can be read off against scale. The instruments can be fitted with bistable switches. The use of high-quality material PVDF (model KSK 3...)means that this type is very suited for service with corrosive media.
Special advantages
Shock resistant and corrosion-resistant May be inserted/removed radially Special scales available Short installation length Plastic float and fitting generally made of PVDF
6. Mechanical Connection
Before Installation:
Remove all transportation safety locks and ensure that no packing material
remains within the unit.
Be sure that the maximum allowable operating pressure and temperature is
not exceeded (see Technical Data).
Install the flow meter in the piping system, ensure the instrument is under no
mechanical stress/tension (install support bracing if necessary).
Protect the measuring tube from external damage. Avoid pressure peaks in the measuring tube, e.g. from sudden surges or
stoppage of flow.
The units with bistable reed switch may not be installed within an inductive
field.
If possible, immediately after making mechanical connections, check whether
the connections are properly sealed with no evidence of leakage (see section 8 Operation).
Detailed information regarding installation of float flow meters is available in VDI/VDE guidelines 3513.
Page 5
KSK
KSK K03/0316 page 5
7. Electrical Connection
7.1. Reed Contact, bistable (option)
Make sure that the supply wires are de-energized. Loosen the plug-cap holding screw and remove the cap from the switch
housing.
Connect the supply lines inside the plug in accordance with the connection
diagram opposite.
If the set point has not yet been adjusted, it may be done at this point. (see
section 8. Operation).
Set the plug to the socket and fix it with the safety screws.
Attention! The stated electrical parameters of the contact may not be exceeded, even for a short period of time. For inductive or capacitive loads, we recommend the use of contact protection measures respectively the application of a contact protection relay.
Page 6
KSK
7.2. Electronic Contact (option)
Make sure that the supply wires are de-energized. Loosen the plug-cap holding screw and remove the cap from the switch
housing.
Connect the supply lines inside the plug in accordance with the connection
diagram opposite.
If the set point has not yet been adjusted, it may be done at this point. (see
section 8. Operation).
Set the plug to the socket and fix it with the safety screws.
Attention! The stated electrical parameters of the contact may not be exceeded. For inductive or capacitive loads, we recommend the use of contact protection measures respectively the application of a contact protection relay.
After connecting the external devices, and adjusting the switch housing to the desired switch points, all the connection work is completed. The unit is ready for operation.
Signal max. 100mA
LED
+V
S
GND
R
L
Page 7
KSK
KSK K03/0316 page 7
8. Operation
In order to initialise the bistable switching function, it is essential that the float activates the contact once in each direction.
Adjustment of limit-values
The switch-point can be adjusted to the desired levels by using both red sliders as reference points.
Reference edge for falling flow: bottom-edge, switch housing Reference edge for rising flow: approx. 5 mm above the bottom-edge of switch
housing. Slide the switch housing up or down until the reference edge coincides with the desired switch-point scale reading.
Hysteresis
Hysteresis is the difference between the level at which “switch-on” occurs during rising flow and the level at which “switch-off” occurs during decreasing flow. The hysteresis is approximately 5 mm on the float range.
Overranging
With non-pulsating flow, the maximum flow rate can be exceeded. Only an increase in pressure loss will result (max. permissible operating pressure must not be exceeded!)
9. Maintenance
If the medium to be measured is clean, the series KSK is virtually maintenance­free. If deposits form on the inner housing or parts, periodic cleaning of the unit is recommended. Remove the units from the piping with a suitable tool; clean the flow meter with a suitable cleaning agent or make use of an ultrasonic bath.
Page 8
KSK
10. T echnical Information
Materials
Measuring tube: Trogamide T (KSK 1..) or polysulfone (KSK 2..) or
PVDF (KSK 3..)
not transparent, but opaque translucent Float: PVDF O-rings: EPDM (KSK-1../KSK-2..)
FPM (KSK-3..) Max. operating pressure: PN 10 Max. operating temp.: KSK 1... max. 60 °C (0...60 °C)
KSK 2... max. 100 °C (0...100 °C)
(60 °C with PVC screwed fitting)
max. 85 °C (with contact)
KSK 3... max. 140°C Accuracy class: 4 (according to VDE / VDI 3513, sheet 2)
Connection (standard)
KSK 1.. and KSK 2..: PVC glue-in connection KSK 3...: Welding sleeve
Connection (optional) for KSK 1... and KSK 2... only KSK­..080../..150../..200..: Brass or stainless steel union nut
with G 1/2 female or male
or G 3/4 male KSK­..300../..500../..999..: PVC union nut with
G 1/2; G 3/4, G 1 internal thread
or G1 female cast iron KSK-
..015../..025../..050....100..: PVC G 1/4 female
Contacts (optional)
The flow meter can be fitted with either reed contacts or electronic contacts.
Page 9
KSK
KSK K03/0316 page 9
Reed contacts (bistable)
Switching voltage*: max. 130 VAC Breaking capacity*: max. 10 W / 10 VA Switching current*: max. 0.5 A Contact resistance: < 150 m Ohm Insulation resistance: > 105 Ohm Allowed ambient temperature: 0...+ 55 °C Protection: IP 65 Contact hysteresis: approximately 5 - 7 mm floater distance
* Short-time overshoot is not allowed. The use of a contact protection relay is therefore recommended (see Accessories Z2 brochure).
Electronic contacts (bistable)
The contact operates electronically with no mechanical parts that are subject to wear and tear.
Operating voltage: 9 - 24 VDC Switching output: NPN max. 100 mA Ambient temperature: 0...+ 55°C Protection: IP 65 Contact hysteresis: < 6 mm Dimensions: 33 x 18 x 40 mm Weight with plug: 16 g Output signal (with LED at the top) Float above contact across PIN 1 and PIN E: 0 V Float below contact across PIN 1 and PIN E: 9 - 24 V LED out
Page 10
KSK
page 10 KSK K03/0316
11. Order Codes
Measuring
range
water L/h
Order no.
Trogamide
Order no.
Polysulfone
Order No.
PVDF*
Scale measuring
range see table
Thread fitting option Contact option
1.5 - 11
KSK - 1015... KSK - 2015... -
Standard H = L/h Water
Special scale A= air; 0 bar gauge B= air; 1 bar gauge C= air; 2 bar gauge D= air; 3 bar gauge E= air; 4 bar gauge F= air; 5 bar gauge G= air; 6 bar gauge I= air; 7 bar gauge K= air; 8 bar gauge L= air; 9 bar gauge M= air;10 bar gauge Y= other
K16= PVC-glue-in connection 16 V16= PVDF-Welding sleeve 16* P08= PVC G 1/4 female
O0= without contact S0= 1 N/O contact SS= 2 N/O contacts SC= 1 N/O contact/
1 NC contact
C0= 1 NC contact CC= 2 NC contacts E0= 1 electr. cont. EE= 2 electr. cont.
2.5 - 30
KSK - 1025... KSK - 2025... KSK - 3025...*
5 - 50
KSK - 1050... KSK - 2050... KSK - 3050...*
10 - 100
KSK - 1100... KSK - 2100... KSK - 3100...*
8 - 80
KSK - 1080... KSK - 2080... KSK - 3080...*
K20= PVC-glue-in connection 20 V20= PVDF-Welding sleeve 20* IG1= brass G 1/2 female AG1= brass G 1/2 male AG3= brass G 3/4 male IG2= stainless steel G 1/2 female AG2= stainless steel G 1/2 male AG4= stainless steel G 3/4 male
O0= without contact S0= 1 N/O contact SS= 2 N/O contacts SC= 1 N/O contact/
1 NC contact
C0= 1 NC contact CC= 2 NC contacts E0= 1 electr. cont. EE= 2 electr. cont..
20 - 150
KSK - 1150... KSK - 2150... KSK - 3150...*
30 - 200
KSK - 1200... KSK - 2200... KSK - 3200...*
30 - 300
KSK - 1300... KSK - 2300... KSK - 3300...*
K32= PVC-glue-in connection 32 V32= PVDF –Welding sleeve 32* P15= PVC G 1/2 female P20= PVC G 3/4 female P25= PVC G 1 female T25= Cast iron G 1 female
O0= without contact S0= 1 N/O contact SS= 2 N/O contacts SC= 1 N/O contact/
1 NC contact
C0= 1 NC contact CC= 2 NC contacts E0= 1 electr. cont. EE= 2 electr. cont..
50 - 500
KSK - 1500... KSK - 2500... KSK - 3500...*
100 - 1000
KSK - 1999... KSK - 2999... KSK - 3999...*
*KSK-3... for PVDF-Welding sleeve and without air scale only
Page 11
KSK
KSK K03/0316 page 11
12. Dimensions
Page 12
KSK
page 12 KSK K03/0316
13. EU Declaration of Conformance
We, KOBOLD Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product:
Plastic Flow Meter Model: KSK-...
to which this declaration relates is in conformity with the standards noted below:
EN 61000-6-3:2011-09
Electromagnetic compatibility, Interference emission living quarters
EN 61010-1:2011-07
Safety regulations for electrical measurement, control, regulation and Laboratory equipment
EN 60529:2014-09
Protection through housing (IP-Code)
Also the following EC guidelines are fulfilled:
2014/30/EU EMC Directive 2014/35/EU Low Voltage Directive 2011/65/EU RoHS (category 9)
Hofheim, 05. April 2016 H. Peters M. Wenzel General Manager Proxy Holder