Load Limitations
4 mA to 20 mA Output Only
Vmin = [10V + (.020 x RL)] - O.137 Ωx
cable length
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
KPK 4 mA to 20 mA 2-Wire
+ Supply Red/1/A/1/Brown
+ Output Black/2/B/3/Blue
2 WIRE
WIRING
DIAGRAM
EXAMPLE
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x RL)
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
Example: Red/1/A/1 = Applicable color
wire/din plug number/bendix pin/M12 x 1
pin number/M12 color wire
KPK 0-5, 1-6, 0-10
1 Vdc to 11 Vdc 3-WIRE
+ Supply Red/1/A/1/Brown
Common Black/2/B/3/Blue
+ Output White/3/C/4/Black
3 WIRE
WIRING
DIAGRAM
EXAMPLE
Example: Red/1/A/1 = Applicable color
wire/din plug number/bendix pin/M12 x 1
pin number/M12 color wire
KPK
KPK
Example: Red/1/A/1/1 = Applicable color
wire/din plug number/bendix pin/junction box
pin/M12 x 1 pin number/M12 color wire
Example: Brown/1 = Applicable color
wire/M12 x 1 pin number.
Example: Red/1 = Applicable color wire/din
plug number.
KPO 4 mA to 20 mA 2-Wire
+ Supply Red/1
+ Output Black/2
KPO Voltage Output
+ Supply Red/1
Common Black/2
+ Output White/3
Power
Supply
Output
Black
Power
Supply
Output
White
Black
3 WIRE WIRING
DIAGRAM EXAMPLE
Red
Red
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x RL)
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
KPO
KPW
2 WIRE WIRING
DIAGRAM EXAMPLE
KPG 4 mA to 20 mA 2-Wire
+ Supply Red/1/A/1/1/Brown
+ Output Black/2/B/2/3/Blue
KPG Voltage Output
+ Supply Red/1/A/1/1/Brown
Common Black/2/B/2/3/Blue
+ Output White/3/C/3/4/Black
KPC Voltage Output
+ Supply Brown/1
Common Blue/3
+ Output Black/4
Red
Red
Black
Output
Power
Supply
Black
Red
Black
Output
Power
Supply
Red
White
Power
Supply
Output
Black
White
Power
Supply
Power
Supply
Output
Power
Supply
Output
Output
2 WIRE WIRING
DIAGRAM EXAMPLE
3 WIRE WIRING
DIAGRAM EXAMPLE
WIRING
DIAGRAM EXAMPLE
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x RL)
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
KPC
KPG
2 WIRE WIRING
DIAGRAM EXAMPLE
3 WIRE WIRING
DIAGRAM EXAMPLE
Black
Power
Supply
Output
Red
Red
Blue
Black
White
Power
Supply
Output
KPW 4 mA to 20 mA 2-Wire
+ Supply Red
+ Output Black
Case ground Blue
KPW Voltage Output
+ Supply Red
Common Black
+ Output White
Case ground Blue
Blue
M
Black
Blue
Brown
Black
Blue
Brown
Wiring Mini-Hirschmann
connector
Wiring Mini-Hirschmann
connector
Current output, 2 wire
Power
Supply
+ Supply
+ Output
Output
Voltage output, 3 wire
+ Supply
+ Output
Common
Output
Power
Supply
1
3
1
3
2
1
3
2
•
•
•
•
•
•
•
•
Power
Supply
+ Supply
+ Output
Output
Wiring M12 x 1 4-pin
round connector
Wiring M12 x 1 4-pin
round connector
+ Supply
+ Output
Common
Power
Supply
Output
Wiring - M12 x 1 4-pin
round connector
+
–
34
2
1
KOBOLD
TRANSMITTERS
TRANSDUCERS
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x RL)
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
KPB
KPL 4 mA to 20 mA 2-Wire
+ Supply Brown/1/1/Brown
+ Output Green/2/3/Blue
KPL
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x RL)
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x RL)
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
KPT
KTT 4 mA to 20 mA 2-Wire
+ Supply Red/1
+ Output Black/2
KTT Voltage Output
+ Supply Red/1
Common Black/2
+ Output White/3
KTT
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x RL)
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
KWD 04
Example: Brown/1/1 = Applicable color wire/din
plug number M12 x 1 Pin number/M12 color
wire
KPT 4 mA to 20 mA 2-Wire
+ Supply Red/1/1/Brown
+ Output Black/2/3/Blue
Example: Red/1/1 = Applicable color wire/din
plug number M12 x 1 Pin number/M12 color
wire
Example: Red/1 = Applicable color wire/din
plug number.
Installation:
KOBOLD pressure transmitters/transducers may
be mounted in any plane with negligible effect on
performance. Although these units are designed
and manufactured to withstand substantial shock
and vibration, it is recommended that they be
mounted in an area of minimal vibration. Always
use a wrench on the wrench flats when installing.
NEVER use a pipe wrench on the housing or in
the area of the electrical connection.
Maintenance/Calibration:
KOBOLD pressure transmitters/transducers
require no maintenance. Recalibration is
dependent on the users Quality Assurance
Program. If no program is in place, KOBOLD
recommends a 1 year cycle.
Alignment Procedure (applies only to
KPK, KPG, and KPB series):
Using a pressure source and meter with adequate
accuracy, perform the following steps:
• Open sensor
• With no pressure applied,
adjust the “Z”
potentiometer for the
correct Zero output
• Apply the correct full scale
pressure to the unit
• Adjust the “S”
potentiometer for the
correct Span output
Span
Zero
1
2
3
4
5
1
2
3
4
5
6
7
8
9
6
7
8
9
RX white
brown
yellow
RT
TXD
DT
GN
Wiring - Mini-Hirschmann
connector
Wiring - M12 x 1 4-pin
round connector
Wiring - M12 x 1 4-pin
round connector
Current output, 2 wire
Voltage output, 3 wire
Voltage output, 3 wire
Current output, 2 wire
4 mA to 20 mA, 2 wire 0 Vdc to 10 Vdc, 3 wire
Wiring - Mini-Hirschmann
connector
Current output, 2 wire
Voltage output, 3 wire
Current output, 2 wire
Voltage output, 3 wire
Power
Supply
+ Supply
+ Supply
+ Output
+ Output
Common
Output
Output
Power
Supply
Power
Supply
+ Supply
+ Supply
+ Output
+ Supply
+ Output
+ Output
Common
Output
Power
Supply
Output
+ Supply
+ Output
Common
Power
Supply
Output
+ Supply
+ Output
Power
Supply
Output
+ Supply
+ Output
Common
Power
Supply
Output
+ Supply
+ Output
Power
Supply
Output
+ Supply
+ Output
Common
Power
Supply
Output
Output
Power
Supply
Wiring - M12 x 1 4-pin
round connector
Voltage output, 3 wire
Current output, 2 wire
Power
Supply
+ Supply
+ Supply
+ Output
+ Output
Common
Output
Output
Power
Supply
RS 232 Interface
Pressure
Sensor
1
3
2
1
3
2
1
3
2
1
3
2
•
•
•
•
•
•
KPT Voltage Output
+ Supply Red/1/1/Brown
Common Black/2/3/Blue
+ Output White/3/4/Black
KPL Voltage Output
+ Supply Brown/1/1/Brown
Common Green/2/3/Blue
+ Output White/3/4/Black
Wiring Diagrams & Electrical
Connections for:
KOBOLD
INSTRUMENTS INC.
1801 Parkway View Drive
Pittsburgh, PA 15205
TEL: 800-998-1020
FAX: 412-788-4890
E-mail: kobold@koboldusa.com
Web: www.kobold.com
KOBOLD INSTRUMENTS
CANADA INC.
9A de l’Aviation
Pointe Claire, QC H9R 4Z2
TEL: 888-769-5550
FAX: 514-428-8899
E-mail: kobold@kobold.qc.ca
KPK, KPO, KPW, KPG,
KPB, KPC, KPT, KPL and KTT
1
3
2