Kobold DTK User Manual

Page 1
Operating Instructions
for
Low Volume Rotating Vane
Flow Meter
Model: DTK
Page 2
DTK
1. Contents
1. Contents ........................................................................................................ 2
2. Note 3
3. Instrument Inspection .................................................................................... 3
4. Regulation Use.............................................................................................. 3
5. Operating Principle........................................................................................ 4
6. Mechanical Connection ................................................................................. 4
7. Electrical Connection ....................................................................................5
7.1 General ................................................................................................ 5
7.2 Plug Connection ..................................................................................5
7.3 Cable Connection ................................................................................5
7.4 Compact Electronics: (..C30R, ..C30M, ..C34P, ..C34N) .................... 5
8. Technical Information .................................................................................... 6
9. Order Codes .................................................................................................8
10. Dimensions ...................................................................................................9
11. Declaration of Conformance ....................................................................... 12
Manufactured and sold by:
Kobold Messring GmbH
Nordring 22-24
D-65719 Hofheim
Tel.: +49(0)6192-2990
Fax: +49(0)6192-23398
E-Mail: info.de@kobold.com
Internet: www.kobold.com
page 2 DTK K01/0708
Page 3
DTK
2. Note
Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents.
When used in machines, the measuring unit should be used only when the machines fulfil the EWG-machine guidelines.
as per PED 97/23/EG
In acc. with Article 3 Paragraph (3), "Sound Engineering Practice", of the PED 97/23/EC no CE mark. Diagram 8, Pipe, Group 1 dangerous fluids
3. Instrument Inspection
Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / forwarding agent immediately, since they are responsible for damages during transit.
Scope of delivery:
The standard delivery includes:
Low Volume Rotating Vane Flow Meter model: DTK
Operating Instructions
4. Regulation Use
Any use of the Low volume rotating vane flowmeter, model: DTK”, which exceeds the manufacturer’s specification may invalidate its warranty. Therefore, any resulting damage is not the responsibility of the manufacturer. The user assumes all risk for such usage.
DTK K01/0708 page 3
Page 4
DTK
5. Operating Principle
The medium flows through a specially shaped flow housing and causes a vane to rotate. The vane has imbedded permanent magnets. Which are detected by a Hall Effect sensor as they pass. The Hall Effect sensor generates a voltage pulse each time a magnet passes. The frequency of the pulses is directly proportional to the flow velocity.
6. Mechanical Connection
Before installation:
Remove all transport packaging and ascertain that no packaging material is left
in the instrument
Please ascertain whether the allowable maximum operating pressure and
operating temperature of the instruments will not be exceeded (see standard material combinations).
Please ascertain after completing of mechanical installation, whether the
connection between fitting and pipe is tight.
Warning! Overflows of more than 20 % might damage the bearings and cause larger measuring errors or malfunction.
page 4 DTK K01/0708
Page 5
DTK
7. Electrical Connection
7.1 General
Make sure that the power supply wires are de-energized.
Connect the power supply and output signal wires according to the wiring
diagrams under 7.2
Caution! Incorrect connection will destroy the electronics. Make sure that the power supply values of your system are matching the power supply values of this instrument.
7.2 Plug Connection
DTK-...0400 DTK-...F3; DTK-...L3
NPN open collector PNP open collector
7.3 Cable Connection
DTK-...0P00; DTK-...0S00
white: + V brown: GND green: signal NPN open collector
S
7.4 Compact Electronics: (..C30R, ..C30M, ..C34P, ..C34N)
see Instruction Manual-Supplement for Compact Electronics
DTK K01/0708 page 5
Page 6
DTK
8. Technical Information
Measuring accuracy: ± 2 % f. s.
Linearity: ± 1 % v. ME Repeatability: ± 0.25 % Medium temperature: -15 °C to +80 °C
Ambient temperature: -15 °C to +60 °C Max. pressure: 30 bar
Materials
Housing: Stainless steel 1.3955 Orifice: Stainless steel 1.4404 Axle: Stainless steel 1.4404 Rotating vane: PVDF Gasket: FPM (FPM) Connection: G ¼ female thread
Installation position: horizontal Protection type: IP 65
Electrical Data
OEM frequency output (DTK-...0*00) without CE-sign
Power supply: 4 – 24 V Current input: typ. 5 mA Pulse output: NPN, max. 20 mA, open collector Electrical connection: 1,5 m PVC cable
AUF-4000 (option for DIN plug connector connection)
Display: 4-segment red LED Temperature range: -20 to +80 °C Power supply: 24 VDC ± 20 % Input: Pulses of DTK (NPN-Hall effect sensor) Output: 4 – 20 mA, 3-wire Load: 250
DTK-...F300
Power supply: 12 – 28 V Current input: 10 mA Pulse output: PNP, open collector, max. 20 mA Electrical connection: plug connector M12x1
± 5 % f. s. OEM-version
-15 °C to +140 °C (DTK-...0S00)
¼ NPT female thread
DC
1,5 m silicone cable plug connector DIN 43650
DC
page 6 DTK K01/0708
Page 7
DTK-...F390
Power supply: 24 VDC ± 20 % Current input: 15 mA Pulse output: PNP; open collector, max. 20 mA Frequency divider: 1...1/128, factory setting Electrical connection: plug connector M12x1
DTK-...L303; DTK-...L343
Power supply: 24 VDC ± 20 % Output: 0(4) – 20 mA, 3-wire Max. load: 500 Electrical connection: plug connector M12x1
Compactelectronics
Display: 3-segment LED Analogue Output: (0) 4…20 mA adjustable, max. 500 Switching Outputs: 1 (2) Semiconductor PNP or NPN, factory-set Contact-function: N/C, N/O programmable Adjustment: via 2 buttons Power-Supply: 24 VDC ± 20 %, 3-wire technology, approx. 100mA Electrical Connection: Plug M12x1
DTK
DTK K01/0708 page 7
Page 8
DTK
9. Order Codes
Example: DTK-1206 G2 0000
Meas. range
[L/min]
Orifice
[mm]
Frequency
at ME
Pressure
loss at ME
Model Connection Evaluating electronics
0.05 - 0.6 1.0 21 Hz 1.0 bar
0.1 - 1.3 1.5 30 Hz 1.0 bar
0.2 - 2.0 1.8 36 Hz 1.1 bar
0.3 - 3.5 2.5 41 Hz 0.9 bar
0.3 - 5.0 3.0 47 Hz 0.9 bar
0.5 - 7.0 3.5 51 Hz 1.0 bar
0.5 - 10.0 5.0 50 Hz 1.0 bar
1.0 - 12.0 6.0 44 Hz 0.9 bar
DTK-1210..
DTK-1215..
DTK-1218..
DTK-1225..
DTK-1230..
DTK-1233..
DTK-1250..
DTK-1260..
Plug-on display
for model DTK-...0400 (with DIN plug connector)
Description Order number
4-segment red LED display Input: pulses of DTK (NPN-Hall effect sensor), Power supply: 24 V
DC
Output: 4-20 mA 2-wire (max. 250 Ω) Plug connector DIN 43650
Accessory
Round connector
Typ Description
ZUB-KAB-12D500 Round connector M12 x 1 Dose with terminal, 5-pol ZUB-KAB-12K002 Round connector M12 x 1 Dose with 2 m cable, 4-pol ZUB-KAB-12Q000 Round connector M12 x 1 Dose with Quick-on, 4-pol
..G2..= G 1/4
..N2..= 1/4 NPT
OEM frequency output without CE
..0P00= NPN, 1.5 m PVC cable ..0S00= NPN, 1.5 m silicone cable ..0400= NPN, plug connector DIN 43650
Frequency output
..F300= plug connector M12x1, PNP ..F320= plug con. M12x1, PNP, divider 1:2 ..F340= plug con. M12x1, PNP, divider 1:4 ..F390= plug con. M12x1, PNP, divider 1...
Analogue output
..L303= plug con. M12x1, 0 - 20 mA, 3-wire ..L343= plug con. M12x1, 4 - 20 mA, 3-wire
Compact electronic ..C30R= Compact electronics, 2xPNP, plug M12x1 ..C30M= Compact electronics, 2xNPN, plug M12x1 ..C34P= Compact electronics, 4-20mA, 1xPNP ..C34N= Compact electronics, 4-20mA, 1xNPN
AUF-4000
1
/128
page 8 DTK K01/0708
Page 9
DTK
10. Dimensions
DTK-...0P00; DTK-...0S00
DTK K01/0708 page 9
Page 10
DTK
DTK-...0400
DTK-...0400 with AUF-4000
page 10 DTK K01/0708
Page 11
DTK-...F3..; DTK-...L3...
DTK
DTK-...with compact electronic
DTK K01/0708 page 11
Page 12
DTK
11. Declaration of Conformance
We, KOBOLD Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product:
Low Volume Rotating Vane Flow Meter Model: DTK-...
to which this declaration relates is in conformity with the standards noted below:
EN 50081-2 1994-03
EN 50082-2 1996-02
DIN EN 61010-1 1994-03
EN 60529, DIN VDE 0470-1 1992-11
Also the following EWG guidelines are fulfilled:
2004/108/EC EMC Directive 2006/95/EC Low Voltage Directive
97/23/EG PED
Category I, Table 8, pipe, D 1 dangerous fluids Module, mark CE0098 notified body: Germanischer Lloyd Cert.-number: 390362-08 HH
Hofheim, 24. Jul. 2008
page 12 DTK K01/0708
H. Peters M. Wenzel
General Manager Proxy Holder
Loading...