The DSD features a ceramic pressure sensing element which provides
superior stability and exceptionally long cycle life for pressure ranges up
to 8700 PSI. Ranges above 8700 PSI utilize a stainless steel pressure
sensing element. The DSD is available in battery powered or 24VDC
powered versions which feature a 4 digit LCD rotatable display. Zero
(tare), peak hold, relay, and analog output features are controlled by
push-button access to the programming menu which has a password
protection capability. The optional relay output switching point is
fully adjustable along with the hysteresis. The analog output signal
options, available for remote transmission of the measured values,
have adustable start and end points and are also adjustable via the
front key panel.
Specifications
Measuring Ranges: 0...30” Hg Vacuum up to 0...20,000 PSIG
Overpressure Ratings
up to 500 PSIG: 3x Full Scale
500 to 2000 PSIG: 2x Full Scale
above 2000 PSIG*: 1.5x Full Scale
*8700 PSIG model only: 1.3x Full Scale
Accuracy: ±0.5% of Full Scale
Temperature Coefficient
Zero Point: ±0.2% of full scale/10k
Range: ±0.1% of full scale/10k
Display: 4-digit LCD, 0.5” Digits
Housing: Polyester, 74 mm
Fitting: 1/4” NPT (Models up to 8700 PSIG)
1/2" NPT (Models 14,500 & 20,000 PSIG)
Wetted Materials
Sensing Element: Ceramic ranges up to 8700 PSIG
Stainless Steel for 14,500 & 20,000 PSIG
Connection: 316 SS
O-Ring: NBR; Others on Request
Temperature Range
Storage: -20...176 °F
Process: -20...185 °F
Ambient: -4...140 °F
Battery Type (DSD-5..): 9 Volt Lithium (Included)
Battery Life
Alkaline: 2000 hours continous operation
7300 hours switched off
Lithium: 5200 hours continous operation17300 hours switched off
Supply Voltage (DSD-6..): 24 VDC ±20%
Accessory Connecting Cable Pin Assignments
Relay Option Option R: N/O Bi-stable, 2 amps at 30V DC/AC
Analog Output Option A2: 0-2 VDC (load: 100k Ohm or higher)
Analog Output Option A4: 4-20 mA (load: 500 Ohm or less,
galvanically not isolated)
Electrical Connection: 5 PIN Micro-DC, Male
Automatic Shut-off: 8 minutes standard (DSD-5.. only)
0...64 min., factory set (DSD-5.. only)
Peak Memory Value: MIN or MAX values, reset by keypad
Protection: IP 65
Weight: 0.8 lb