Kobold DRG Series, DRG-F Series, DRZ-**Z Series, DRG-**L442, DRG***L3 Series Operating Instructions Manual

...
Operating Instruction
for
Rotating Vane Flow Meter
Model: DRG-...
Page 2 DRG K02/0316
1. Contents
1.
Contents ........................................................................................................ 2
2.Note .............................................................................................................. 3
3.Regulation Use .............................................................................................. 3
4.Operating Principle ........................................................................................ 3
5.Instrument Inspection .................................................................................... 4
6.Mechanical Connection ................................................................................. 4
7.Electrical Connection .................................................................................... 5
8.Commissioning – Evaluation Electronics ...................................................... 8
9.Technical Information .................................................................................... 8
10.Order Details ............................................................................................... 10
11.Maintenance ............................................................................................... 11
12.Dimensions ................................................................................................. 11
13.EU Declaration of Conformance .................................................................. 14
Manufactured and sold by:
Kobold Messring GmbH
Nordring 22-24
D-65719 Hofheim
Tel.: +49(0)6192-2990
Fax: +49(0)6192-23398
E-Mail: info.de@kobold.com
Internet: www.kobold.com
DRG
DRG K02/0316 Page 3
2. Note
Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents.
When used in machines, the measuring unit should be used only when the machines fulfil the EG-machine guidelines.
PED 2014/68/EU
In acc. with Article 4 Paragraph (3), "Sound Engineering Practice", of the PED 2014/68/EU no CE mark. Table 8, Pipe, Group 1 dangerous fluids
3. Regulation Use
The Model DRG-..., rotating vane flow meter is to be installed only in applications that are within the specified operating limits. An use which exceeds the specifications is prohibited. Any damages resulting therefrom are not the responsibility of the manufacturer. The user assumes all risk for such usage. The application specifications include the installation, start-up and service requirements specified by the manufacturer.
4. Operating Principle
KOBOLD rotating vane flow meters series DRG are used for measuring and monitoring low viscosity liquids. Series DRG flow meters are working according the well known rotating vane principle. A magnet fitted in the vane and hermetically sealed from the medium transfers the rotary motion of the vane to a Hall-effect sensor mounted in the housing. The sensor converts the rotary motion which is proportional to the flow to a frequency signal. The frequency is therefore proportional to flowrate. A series-connected electronics unit converts the signal to an analogue output, limit contacts or display.
Page 4 DRG K02/0316
5. Instrument Inspection
These devices are checked before dispatch and sent away in perfect condition. Should the damage to a device be visible, we recommend a thorough inspection of the delivery packing. In case of damage, please inform your parcel service/ forwarding agent immediately, since they are responsible for damages during transit.
Scope of delivery:
Rotating Vane Flow Meter model: DRG Operating Instructions
6. Mechanical Connection
6.1. Operational conditions check up:
Max. flowrate Max. operational pressure Max. operational temperature
Attention! In case, specified range is over-violated, bearings may get damaged and considerable measurement errors may result.
6.2. Installation
It must be ensured that the instrument housing is continuously filled with the
flow medium, especially for flows from top to bottom. No straight lengths are necessary at inlet and outlet connections.
Flow in the direction of arrow pointer (position independent), front side of the
unit must stand in a vertical plane.
Pressure and tensile loading should be avoided.
Inlet and outlet (piping) should be braced at a distance of 50 mm from the connection location.
Sealing of connections should be checked.
DRG
DRG K02/0316 Page 5
7. Electrical Connection
7.1. General
Attention! Please ensure that the voltage levels of your system are in agreement with that of the flow meter.
Make sure that the electric supply lines are de-energized.
Connect the power supply and output signal on the plug-pins as shown below.
We recommend a cross-sectional area of 0.25 mm² of power supply cable.
Attention! A wrong plug-connection can lead to destruction of unit’s electronics.
7.2. Evaluation electronics: Frequency output (..F300; ..F320, ..F340)
1
2
3
4
+Vs
Signal Out
n.c.
GND