●Electronics Packages Include Analog and Frequency Outputs, Mechanical or LCD Totalizers, and Batch Controllers
●Bi-directional Flow Capability and Optional Quadrature Output
KOBOLD companies worldwide:
ARGENTINA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECH REPUBLIC,
EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO,
NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE, SOUTH KOREA, SPAIN, SWITZERLAND, TAIWAN,
THAILAND, TUNISIA, TURKEY, USA, VIETNAM
01/03- 2014
KOBOLD Instruments, Inc.
1801 Parkway View Drive
Pittsburgh, PA 15205
The DOM series positive displacement flowmeter is the
preferred choice for measuring viscous liquids such as
lubricating/hydraulic oils, diesel fuels, chemicals, solvents,
resins, and pastes.
The Oval Gear meters are positive displacement
flowmeters where the passage of liquid causes two oval
gears to rotate within a precision measuring chamber and
with each rotation a fixed volume of liquid passes through
the meter. Magnets embedded within the gears initiate a
high resolution pulse train output. The pulse output can be
wired directly to process control and monitoring equipment
or can be used as an input to instruments supplied with or
fitted directly onto the meter.
The flowmeter is available as a blind transmitter with
pulse or 4-20mA output capable of interfacing to most
monitoring and control instrumentation or the meter can be
fitted with or supplied with instruments such as totalizers,
rate totalizers or batch controllers. These instruments also
have monitoring and control output options including 4-20
mA, scaled pulse, flowrate alarms and batch control logic
(preset metering).
This technology allows precise flow measurement and
dispensing of most clean liquids regardless of their
conductivity, with other liquid characteristics having no
or minimal effect on meter performance. This metering
technology does not require flow profile conditioning
or straightline runs as required with alternative flow
technologies making the installation relatively compact and
low cost.
Positive displacement flowmeters are an inexpensive
means to accurately meter high viscosity clean liquids as
high as 1 million centipoise. The appropriate meter must be
sized to accomodate the pressure drop across the primary
measuring elements (oval rotors) and to not exceed the
maximum pressure capability of the meter.
Specifications
Wetted MaterialDOM-A05..DOM-A15Body: Aluminum
Gear/Bearing:Sintered 316 Stainless Steel/
Carbon Ceramic or PPS/No
Bearing*
DOM-A20..DOM-A60Body: Aluminum
Gear/Bearing:Aluminum/Hardened Steel
Rollers (Lubricating Fuels and
Oils only) or PPS/No Bearing*
High Pressure Threaded - Pulse Output*AluminumStainless
DOM-H05.. - DOM-H30..x5800
DOM-H35..x4350
2
www.koboldusa.com
No responsibility taken for errors;
subject to change without prior notice.
Positive Displacement Flowmeter Model DOM
Pulse Output
Reed/Hall Effect Sensor Pulse Output (..H0)
The Hall Effect sensor is a high resolution solid state 3
wire device providing an unsourced, open collector, NPN
transistor output. The term “un-sourced” means that no
voltage is applied to the output from within the flowmeter,
it must be pulled to a “high” or “on” state by between
5 - 24 VDC supplied from an external source, typically the
receiving instrument.
The pulse output between signal and -0 V is a voltage
square wave with the high level being the DC voltage
available at the open collector and the low level being
-0 V.
The receiving instrument must incorporate a pull up
resistor (typically greater than 10 kΩ in most instruments)
which ties the open collector to the available DC voltage
level when the Hall sensor is not energized. When
energized the open collector output is pulled to ground
through the emitter (-0 V).
For the Reed Switch technical description, see the R0
details below.
Hall Effect Power Supply: max. 5-24 VDC, max. 20 mA
Dual Reed Switch Pulse Output (..R0)
The dual reed switch output are two wire normally open
SPST voltage free contacts ideal for installations without
power or for use in hazardous area locations when
Intrinsically Safe (I.S.) philosophy is adopted.
Note: When using the reed switch output the liquid
temperature must not change at a rate greater than 50
ºF per minute. In general the reed switch life will exceed 2
billion actuations when switching less than 5 VDC/10 mA.
Power Supply: max. 30 VDC, max. 200 mA
Quadrature Hall Effect Pulse Output (..D0)
Two Hall Effect sensors arranged to give separate outputs
90° out of phase with one another. The quadrature output
is typically suited to custody transfer applications where
signal integrity verification is required, it is also used for
metering bi-directional flow.
Power Supply: max. 8 - 24 VDC, max. 20 mA
Mechanical Totalizer (..M4)
The flowmeters type DOM-x20.. up to DOM-x60.. are
available with a mechanical totalizer with a 4-digit
resettable totalizer and indication of accumulated total
value. The motion of the rotors is transmitted to the
mechanical register totalizer via an interfacing reduction
gear train and dynamic seal assembly. For models
DOM-x20.. & DOM-x25.. the resettable totalizer and
accumulated totalizer read in x1 gallons. For models
DOM-x30.. to DOM-x60.. the resettable totalizer and
accumulated totalizer read in x10 gallons.
Signal Converter (..L0)
The L0 signal converter option may be set to function as either a
frequency to current converter (2-wire 4-20mA output), a pulse
divider, or a single point flow rate alarm. The signal board also has
an NPN pulse output which mirrors the input pulse frequency, this
signal may be used for remote rate and/or total indication.
Power Supply: 24 V
DC
ATEX - Approval (..Z4)
II 2G EEx ia IIB T4 (-4°F < Ta < 140°F)
Electronic with LCD Display
Type..Z1..Z3/..Z4..Z7..B1
FunctionDual
Power Source
Battery-poweredyesyesyesno
External (Drives
Output, Backlighting)
LCD Display
-Line 1/no. of Digits7.5 mm/59 mm/817 mm/69 mm/6
-Line 2/no. of Digits3.6 mm/8-7 mm/8-
Selectable Unitsyesyesyesyes
Decimal Pointyesyesyesyes
Subscripts Displayedyesyesyesyes
Accumulative Totalyesyesyesyes
Resettable Totalyesyesyesno
Linearizationnoyesnono
Rate Displaynoyesyesno
Backlightingnonoyesno
Input Type
Un-powered Sensorssee ZOD datasheet
Powered Sensorssee ZOD datasheet
Outputs
4-20 mA (750 Ω)noyesnono
High/Low Flow AlarmnoNPN/PNPnono
Batch End & ControlnononoNPN/PNP
Pulse OutputsNPN/PNP NPN/PNPNPNNPN/PNP
2 x SPDT Relaysnooptionalnooptional
Installation
NEMA 4X/IP66yesyesyesyes
Cable Entries2 x gland3 x M203 x M163 x M20
Intrinsic Safe (Option)yesyesnono
Mountingmeter mount, pipe, wall, or panel mounting
Temperature Range-4...176 °F (Option: -4...250 °F)
Totalizer
8-24 V
Rate
Totalizer
8-24 VDC8-24 VDC12-24 V
DC
Rate
Totalizer
Batch
Controller
DC
No responsibility taken for errors;
subject to change without prior notice.
www.koboldusa.com
3
Positive Displacement Flowmeter Model DOM
Maximum Flowrate Multiplier (for Higher Viscosities)
Viscosity
(cPs)
≤ 1,00011
≤ 2,0000.51
≤ 4,0000.420.84
≤ 6,0000.330.66
≤ 8,0000.250.5
≤ 30,0000.150.3
≤ 60,0000.120.25
≤ 150,0000.10.2
≤ 250,0000.050.1
≤ 1,000,0000.0250.05
Standard
Rotor
Special Cut
Rotor
Special Cut Rotors for Higher Viscosities
For viscosity > 1000 cP, special cut rotors option "S" should
be used to reduce pressure drop. This applies to DOM-x15
and larger sizes. For higher viscosities, the flowmeter max.
flowrate is de-rated according to the table above. Example:
DOM-x25 measuring oil at 6000 cP, max. flow 40 GPM x
Order Details Thread Connection (Example: DOM-A05G N8 2 H0 0)
Measuring
Range
0.13...9.5 GPH 1/8"
0.5...27 GPH 1/4"
4...145 GPH 3/8"
0.26...10.6 GPM 1/2"
2.6...40 GPM 1"
4...66 GPM 1-1/2"
8...120 GPM 2"
9...150 GPM 2"
10...200 GPM 3"
13...260 GPM 3"
20...400 GPM 4"
40...660 GPM 4"
* not for DOM-x05.., -x10.., -x15..; for DOM-x20.. to DOM-x60.., see M4 option description for details on minimum incremental volume unit per model number
** not available for DOM-x05.., -x10.., -x15.., -x20.., only available for DOM-A..
*** not available for DOM-x05.., -x10..
* see M4 option description for details on minimum incremental volume unit per model number
** only available for DOM-A...
300lb Flanges are availabe for most models upon request
Order Details High Pressure (Example: DOM-H35G N9 2 H0 0)
Note: Dimensions for DOM-S... are specifi ed in ( ) only when they are different from DOM-A,
Dimensions of DOM-H... are specified in [ ].
* Dimensions for DIN flanges, 10.7" for ANSI flanges
6
www.koboldusa.com
No responsibility taken for errors;
subject to change without prior notice.
Positive Displacement Flowmeter Model DOM
Dimensions for DOM-A25… DOM-A40 with Option “A”
Dimensions for DOM-A45… DOM-A60 with Option “A”
Thread Connection (G or NPT)
Model
ABCDABCD
DOM-A2511.713.310.65.9414.214.511.88.39
DOM-A3011.315.711.55.5514.217.014.38.39
DOM-A3511.816.913.95.5514.2*18.1*15.1*8.39*
DOM-A4011.816.913.95.5514.2*18.1*15.1*8.39*
DOM-A4512.819.917.36.3316.622.819.010.4
DOM-A5012.821.118.46.3316.623.920.110.4
DOM-A5517.323.119.68.6221.325.921.513.0
DOM-A6017.324.120.78.6221.327.022.513.0
* +0.04" for DIN flanges
No responsibility taken for errors;
subject to change without prior notice.
DOM Series Flowmeters Company Name: __________________________________________
Application Guide
Rev 09/2013 Phone: __________________________________________
FAX to:
KOBOLD Instruments Inc. Fax: __________________________________________
412-788-4890 (USA)
514-428-8899 (Canada) E-mail: __________________________________________
Design Conditions
Note:
1. Pressure: Maximum ____________ PSIG Accurate design pressure and temperature are essential to
ensure the flowmeter will be built to operate without damage.
2. Temperature: Maximum _________ °F Please fill out accurately and completely.
Process Conditions
1. Type of Liquid: ________________________________ 4. Desired Measuring Range: _______________GPM
2. Normal Operating Temperature: _______________°F 5. Maximum Liquid Viscosity: ___________________
3. Normal Operating Pressure:________________ PSIG 6. Line Size: ______________________
Body Material
Aluminum 316L SS Hi-Pressure 316L SS
O-ring Material
FKM (standard) EPDM PTFE coated FKM NBR
Rotor Material
Aluminum 316L SS PPS (not available on all models)
Fittings
NPT Thread 150LB Flange Other (Specify) _____________________________
S = High-viscosity Rotors C = Cooling Fin for LCD Displays A = Coupled with Air Eliminator-
(not available on all models) (250 °F rating) strainer: Model ZAL
Special requirement, specify below: _____________________________________________________________________