Kobold DOM Specifications

Positive Displacement
Flowmeter
measuring
monitoring
analyzing
DOM
Threaded, Flanged, and High Pressure
Series
Aluminum or Stainless Steel Bodies
Measures Liquids with Viscosities to
1,000 cPs (Higher with Special Cut Rotors)
Operating Pressures to 5,800 PSIG
Bi-directional Flow Capability and Optional Quadrature Output
KOBOLD companies worldwide:
ARGENTINA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECH REPUBLIC, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE, SOUTH KOREA, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, USA, VIETNAM
01/03- 2014
KOBOLD Instruments, Inc. 1801 Parkway View Drive Pittsburgh, PA 15205
Main Ofce:
1.800.998.1020
1.412.788.4890 info@koboldusa.com www.koboldusa.com
Positive Displacement Flowmeter Model DOM
Description
The DOM series positive displacement flowmeter is the preferred choice for measuring viscous liquids such as lubricating/hydraulic oils, diesel fuels, chemicals, solvents, resins, and pastes.
The Oval Gear meters are positive displacement flowmeters where the passage of liquid causes two oval gears to rotate within a precision measuring chamber and with each rotation a fixed volume of liquid passes through the meter. Magnets embedded within the gears initiate a high resolution pulse train output. The pulse output can be wired directly to process control and monitoring equipment or can be used as an input to instruments supplied with or fitted directly onto the meter.
The flowmeter is available as a blind transmitter with pulse or 4-20mA output capable of interfacing to most monitoring and control instrumentation or the meter can be fitted with or supplied with instruments such as totalizers, rate totalizers or batch controllers. These instruments also have monitoring and control output options including 4-20 mA, scaled pulse, flowrate alarms and batch control logic (preset metering).
This technology allows precise flow measurement and dispensing of most clean liquids regardless of their conductivity, with other liquid characteristics having no or minimal effect on meter performance. This metering technology does not require flow profile conditioning or straightline runs as required with alternative flow technologies making the installation relatively compact and low cost.
Positive displacement flowmeters are an inexpensive means to accurately meter high viscosity clean liquids as high as 1 million centipoise. The appropriate meter must be sized to accomodate the pressure drop across the primary measuring elements (oval rotors) and to not exceed the maximum pressure capability of the meter.
Specifications
Wetted Material DOM-A05..DOM-A15 Body: Aluminum Gear/Bearing: Sintered 316 Stainless Steel/ Carbon Ceramic or PPS/No Bearing* DOM-A20..DOM-A60 Body: Aluminum Gear/Bearing: Aluminum/Hardened Steel Rollers (Lubricating Fuels and Oils only) or PPS/No Bearing*
Specifications
DOM-S, DOM-H
Body: 316L Stainless Steel Gear/Bearing: Sintered 316 SS/Carbon Ceramic or PPS/No Bearing* O-Rings: FKM (Standard): 5...250 °F; EPDM (Ethylene Propylene Rubber):
-4...250 °F (for Ketones only); PTFE Encapsulated FKM: -4...250 °F; NBR: -4...210 °F Cover: Glass Reinforced Polyamide Accuracy DOM-x05...DOM-x15: ±1.0% of Reading DOM-x20...DOM-x35: ±0.5% of Reading DOM-x40...DOM-x60: ±0.2% of Reading Repeatability: ±0.03% of Reading Protection: NEMA 4X/IP66 Temperature Range Options Z, B, L0, M4: -4...176 °F Pulse Output: -4...250 °F Electrical Connection: 1/2" NPT
*PPS Rotors not available on some models
Maximum Pressure
Max. Pressure (PSI)
Standard Threaded - Pulse Output* Aluminum Stainless
DOM-x05.. - DOM-x15.. 220 495
DOM-x20.. - DOM-x25.. 990 990
DOM-x30.. 435 435
DOM-x35.. 285 550
DOM-A40.. 285 x
DOM-x45.. 175 175
DOM-A50.. 175 x
DOM-A55.. - DOM-A60.. 145 x
150lb ANSI Flanged - Pulse Output* Aluminum Stainless
DOM-x20.. - DOM-x45.. 175 175
DOM-A50.. 175 x
DOM-A55.. - DOM-A60.. 145 x
Mechanical Meter - Option ..M4 Aluminum Stainless
DOM-x20..M4 - DOM-x25..M4 580 580
DOM-x30..M4 435 435
DOM-x35..M4 - DOM-x40...M4 285 285
DOM-x45..M4 175 175
DOM-A50..M4 175 x
DOM-A55..M4 - DOM-A60..M4 145 x
High Pressure Threaded - Pulse Output* Aluminum Stainless
DOM-H05.. - DOM-H30.. x 5800
DOM-H35.. x 4350
2
www.koboldusa.com
No responsibility taken for errors;
subject to change without prior notice.
Positive Displacement Flowmeter Model DOM
Pulse Output
Reed/Hall Effect Sensor Pulse Output (..H0)
The Hall Effect sensor is a high resolution solid state 3 wire device providing an unsourced, open collector, NPN transistor output. The term “un-sourced” means that no voltage is applied to the output from within the flowmeter, it must be pulled to a “high” or “on” state by between 5 - 24 VDC supplied from an external source, typically the receiving instrument. The pulse output between signal and -0 V is a voltage square wave with the high level being the DC voltage available at the open collector and the low level being
-0 V. The receiving instrument must incorporate a pull up resistor (typically greater than 10 kΩ in most instruments) which ties the open collector to the available DC voltage level when the Hall sensor is not energized. When energized the open collector output is pulled to ground through the emitter (-0 V). For the Reed Switch technical description, see the R0 details below.
Hall Effect Power Supply: max. 5-24 VDC, max. 20 mA
Dual Reed Switch Pulse Output (..R0)
The dual reed switch output are two wire normally open SPST voltage free contacts ideal for installations without power or for use in hazardous area locations when Intrinsically Safe (I.S.) philosophy is adopted. Note: When using the reed switch output the liquid temperature must not change at a rate greater than 50 ºF per minute. In general the reed switch life will exceed 2 billion actuations when switching less than 5 VDC/10 mA.
Power Supply: max. 30 VDC, max. 200 mA
Quadrature Hall Effect Pulse Output (..D0)
Two Hall Effect sensors arranged to give separate outputs 90° out of phase with one another. The quadrature output is typically suited to custody transfer applications where signal integrity verification is required, it is also used for metering bi-directional flow.
Power Supply: max. 8 - 24 VDC, max. 20 mA
Mechanical Totalizer (..M4)
The flowmeters type DOM-x20.. up to DOM-x60.. are available with a mechanical totalizer with a 4-digit resettable totalizer and indication of accumulated total value. The motion of the rotors is transmitted to the mechanical register totalizer via an interfacing reduction gear train and dynamic seal assembly. For models DOM-x20.. & DOM-x25.. the resettable totalizer and accumulated totalizer read in x1 gallons. For models DOM-x30.. to DOM-x60.. the resettable totalizer and accumulated totalizer read in x10 gallons.
Signal Converter (..L0)
The L0 signal converter option may be set to function as either a frequency to current converter (2-wire 4-20mA output), a pulse divider, or a single point flow rate alarm. The signal board also has an NPN pulse output which mirrors the input pulse frequency, this signal may be used for remote rate and/or total indication. Power Supply: 24 V
DC
ATEX - Approval (..Z4)
II 2G EEx ia IIB T4 (-4°F < Ta < 140°F)
Electronic with LCD Display
Type ..Z1 ..Z3/..Z4 ..Z7 ..B1
Function Dual
Power Source
Battery-powered yes yes yes no
External (Drives
Output, Backlighting)
LCD Display
-Line 1/no. of Digits 7.5 mm/5 9 mm/8 17 mm/6 9 mm/6
-Line 2/no. of Digits 3.6 mm/8 - 7 mm/8 -
Selectable Units yes yes yes yes
Decimal Point yes yes yes yes
Subscripts Displayed yes yes yes yes
Accumulative Total yes yes yes yes
Resettable Total yes yes yes no
Linearization no yes no no
Rate Display no yes yes no
Backlighting no no yes no
Input Type
Un-powered Sensors see ZOD datasheet
Powered Sensors see ZOD datasheet
Outputs
4-20 mA (750 Ω) no yes no no
High/Low Flow Alarm no NPN/PNP no no
Batch End & Control no no no NPN/PNP
Pulse Outputs NPN/PNP NPN/PNP NPN NPN/PNP
2 x SPDT Relays no optional no optional
Installation
NEMA 4X/IP66 yes yes yes yes
Cable Entries 2 x gland 3 x M20 3 x M16 3 x M20
Intrinsic Safe (Option) yes yes no no
Mounting meter mount, pipe, wall, or panel mounting
Temperature Range -4...176 °F (Option: -4...250 °F)
Totalizer
8-24 V
Rate
Totalizer
8-24 VDC8-24 VDC12-24 V
DC
Rate
Totalizer
Batch
Controller
DC
No responsibility taken for errors; subject to change without prior notice.