Kobold BVO Series, RVO-11 Series, BVO-12 Series, BVO-11 Series, RVO Series Operating Instruction

Operating Instruction
for
Flowmeter and Monitor
Model: BVO, RVO
Page 2 BVO, RVO K01/0316
1. Contents
1.Contents ........................................................................................................ 2
2.Note .............................................................................................................. 3
3.Regulated usage ........................................................................................... 3
4.Operating Principle ........................................................................................ 4
5.Instrument Inspection .................................................................................... 4
6.Mechanical connection .................................................................................. 5
7.Electrical connection ..................................................................................... 6
8.Commissioning of the Instruments ................................................................ 7
9.Maintenance ................................................................................................. 8
10.Technical Specifications ................................................................................ 8
11.Dimensions and Pressure Losses ................................................................. 9
12.Recommended Spare Parts .......................................................................... 9
13.EU Declaration of Conformance .................................................................. 10
Manufactured and sold by:
Kobold Messring GmbH
Nordring 22-24
D-65719 Hofheim
Tel.: +49(0)6192-2990
Fax: +49(0)6192-23398
E-Mail: info.de@kobold.com
Internet: www.kobold.com
BVO, RVO
BVO, RVO K01/0316 Page 3
2. Note
Please read and take note of these operating instructions before unpacking and setting the unit for operation, and follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and with the prevailing regulation applying to procedural safety and the prevention of accidents.
PED 2014/68/EU
In acc. with Article 4 Paragraph (3), "Sound Engineering Practice", of the PED 2014/68/EU no CE mark. Table 8, Pipe, Group 1 dangerous fluids
3. Regulated usage
Model BVO and RVO instruments are used for monitoring of fluid flows. Only clean, low viscosity and homogenous media may be measured, which do not affect the materials used in the instrument casing. Large measuring errors will occur when using high viscosity media. Large dirt particles can lead to blocking of the float and therefore large measurement and signal errors. Ferritic particles that deposit on the float body (with internal magnet) can also lead to a similar effect therefore we recommend a magnet filter.
The instruments are provided as follows:
Flow measurement
The actual flow can be read locally at the instrument. The scale shows the flow rate directly in litres per minute of water.
Limit Value Contacts
For the monitoring of the flow rate, the instruments can be fitted with one or two adjustable limit value contacts.
Standard Design: Normally open (with rising flow) Special Design: Changeover switch (SPDT) Special Design: Ex-contact N/O, Ex-contact SPDT
The contact is adjustable over the full measuring range.