Kobe RAX9436SQBDC472 User Manual

Brillia Series
KOBE Range Hoods
RAX9430SQB-2 (30”) RAX9430SQB-DC30-2 (30”) RAX9430SQB-DC47-2 (30”)
INSTALLATION INSTRUCTIONS
ISX21 SQB-2 Series
RAX9436SQB-2 (36”) RAX9436SQB-DC30-2 (36”) RAX9436SQB-DC47-2 (36”)
AND OPERATION MANUAL
IMPORTANT
READ THIS FIRST
READ BEFORE INSTALLATION
1. Carefully check all contents of package(s).
2. Thoroughly inspect the unit for any shipping damages, cosmetic damages or defects.
3. Have a certified contractor/electrician test the unit before installation.
IF THERE IS ANY PROBLEM:
1. DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL
PACKAGING MATERIAL.
2. Have your original invoice as proof of purchase and product serial number ready.
3. Contact your merchant for product replacement due to shipping damages, cosmetic damages or defects.
4. For all other issues, email customer.service@koberangehoods.com or call 1-626-775-8880 ext. 103, toll free 1-877-289-5623.
NO RETURN, NO REFUND, NO EXCHANGE IF:
1. PRODUCT HAS BEEN INSTALLED
2. KNOCK-OUT HOLES HAVE BEEN PUNCTURED
3. MISSING ORIGINAL PACKAGING MATERIAL AND/OR PARTS
[ENGLISH]
- READ AND SAVE THESE INSTRUCTIONS -
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS .................................................................................... 1
COMPONENTS OF PACKAGE.................................................................................................. 3
INSTALLATION .......................................................................................................................... 4
OPERATING INSTRUCTIONS................................................................................................... 7
MAINTENANCE ......................................................................................................................... 8
SPECIFICATIONS ..................................................................................................................... 9
MEASUREMENTS & DIAGRAMS .............................................................................................10
PARTS LIST ..............................................................................................................................11
CIRCUIT DIAGRAM ..................................................................................................................13
TROUBLE SHOOTING .............................................................................................................14
WARRANTY .............................................................................................................................15
WARRANTY INFORMATION FORM .........................................................................................17
- READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING -
ALL W I RING MUST B E DON E BY A PROFE S SION A L AND I N
ACCO R D ANCE W ITH N ATION A L AND LOCAL ELECT R ICAL CODES
IMPORTANT SAFETY INSTRUCTIONS
- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -
WARNING
:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING:
1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction.
2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities.
3) Ducted fans must be vented to the outside. a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT SERVICE
PANEL.
b) Clean all grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly,
make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, crawl spaces or garages.
NOTE - This warranty is void without an authorized agent’s receipt or if unit is
damaged due to misuse, poor installation, improper use, mistreatment, negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents. Any repair carried out without the supervision of KOBE RANGE HOODS’ authorized agents will automatically void the warranty.
- KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.
WARNING
1. Keep all fan, baffle/spacer/filter/oil tunnel/oil container and grease-laden surfaces clean. Grease should not be allowed to accumulate on fan, baffle/spacer/filter/oil tunnel/oil container.
2. Always turn hood ON when cooking.
3. Use high settings on cooking range ONLY when necessary.
4. Do not leave cooking range unattended when cooking.
5. Always use cookware and utensils appropriate for the type and amount of food prepared.
6. Use this unit only in the manner intended by the manufacturer.
7. Before servicing, switch power off at service panel and lock service panel (if possible) to prevent power from switching on accidentally.
8. Clean ventilating fan frequently.
: TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE
TOP GREASE FIRE:
1
What to Do In The Event Of a Range Top Grease Fire
SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911.
NEVER PICK UP A BURNING PAN – You May Get Burned.
DO NOT USE WATER, including wet dishcloths or towels – a steam blast will result.
Use an extinguisher ONLY if: a) You have a Class A, B, C extinguisher and know how to operate it. b) The fire is small and contained in the area where it started. c) The fire department has been called. d) You can fight the fire with your back to an exit.
What to Do If You Smell Gas
-
Extinguish any open flame.
-
Do not try to turn on the lights or any type of appliance.
-
Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company and Fire Department right away.
CAUTION
1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors.
2) To reduce the risk of fire, use only metal ductwork. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) to prevent back drafting.
3) Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities.
4) Activating any switch on may cause ignition or an explosion.
5) Due to the size and weight of this hood, installation by 2 persons is recommended.
ELECTRICAL SHOCK HAZARD – Can result in serious injury or death. Disconnect appliance from electric power before servicing. If equipped, the fluorescent light bulb contains small amounts of mercury, which must be recycled or disposed of according to Local, State, and Federal Codes.
2
RAX94 SQB
-2
Series
Range Hood Box
{A} Range Hood Body
– 1
{H} {I}
RAX94DC30
-
I (1-piece Inner Duct Extension)
RAX94DC47
-
I (1-piece Inner Duct Extension)
CONTENTS OF PACKAGE
(Must keep all material for returns or refunds)
{B} 2-pc Duct Cover – 1 {C} Duct Cover Mounting Bracket – 2 {D} Warranty Registration Card – 1 {E} Quick Reference Guide – 1 {F} Baffle Filters x 2 (30” hood)
x 3 (36” hood)
{G} 6” Round Vent Adapter
(for vertical venting) {H} Aluminum Duct Pipe {I} Flapper (2 pcs) {J} Screw Package
{A}
{J}
5 x 12 mm QTY: 6 PCS
4 x 35 mm
Pre-attached to
Vent Adapter
4 x 8 mm QTY: 6 PCS (Pre-attached to Vent Adapter)
12 x 40 mm QTY: 6 PCS (For sheet rock only)
{B} {C}
Inner duct cover Outer duct cover
{D} {E}
(Included in RAX94 SQB-DC30-2 only)
{K} 1-piece Inner Duct Extension
Model No.: RAX94DC30-I
{K}
(Included in RAX94 SQB-DC47-2 only)
{F} {G}
FOR MORE INFORMATION, PLEASE VISIT OUR WEBSITE www.koberangehoods.com.
{L} 1-piece Inner Duct Extension
Model No.: RAX94DC47-I
{L}
3
TABLE 1
Before Installation
Venting Requirements
INSTALLATION
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
Calculation before Installation
To calculate installation, please refer to TABLE 1 (all calculations are in inches.)
- FOR WALL MOUNT -
A = Height of Floor to Ceiling B = Height of Floor to Counter Top
(Standard: 36")
C = Preferred Height of Counter Top
to Hood Bottom (Minimum 26" to 30")
D = Height of Hood E = Height of Duct Cover [F – D] F = Height of the Hood Installation [A – (B+C)]
SAFETY WARNING
HOOD MAY HAVE SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF REMOVING
ANY PARTS FOR INSTALLING, CLEANING, OR SERVICING.
BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY
OCCUR. USING HAND TOOLS IS RECOMMENDED. DO NOT OVER TIGHTEN SCREWS.
MAKE SURE TO PREVENT ANY DEBRIS FROM ENTERING THE VENT OPENING TO AVOID
DAMAGE OR MALFUNCTION.
WALL MOUNT INSTALLATION
**Installation videos available at www.koberangehoods.com**
1. Read any provided document(s).
2. Test the range hood by temporarily connecting to an outlet and turning ON the fan and lights.
3. If you run into any problems, contact KOBE Range Hoods.
4. This range hood has top 6” round exhaust.
5. Decide the location of the venting pipe from the hood to the outside. A straight, short vent run will allow the hood to perform more efficiently. Try to avoid elbows, transitions, and long run as much as possible as this may reduce the performance of the hood. Make sure that the duct work leads to the outside.
4
Loading...
+ 15 hidden pages