Kobe IS2036GS User Manual [en, es, fr]

KOBE Brand Range Hood
Model No. IS2036GS IS2042GS
“ISLAND GLASS CANOPY”
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
1
CONTENTS
- READ AND SAVE THESE INSTRUCTIONS -
IMPORTANT SAFETY INSTRUCTIONS......................................................................... 1
COMPONENTS OF PACKAGE....................................................................................... 3
INSTALLATION ............................................................................................................... 4
OPERATION INSTRUCTIONS........................................................................................ 8
MAINTENANCE .............................................................................................................. 9
SPECIFICATIONS......................................................................................................... 11
MEASUREMENTS & DIAGRAMS................................................................................. 12
PARTS LIST.................................................................................................................. 13
CIRCUIT DIAGRAM...................................................................................................... 15
TROUBLE SHOOTING ................................................................................................. 16
DISCLAIMER ................................................................................................................ 17
WARRANTY.................................................................................................................. 18
PRODUCT REGISTRATION ......................................................................................... 20
- READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING -
ALL WIRING MUST BE DONE BY A PROFESSIONAL AND IN
ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES
IMPORTANT SAFETY INSTRUCTIONS
- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -
WARNING
1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction.
2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities.
3) Ducted fans must be vented to the outside. a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT SERVICE
PANEL.
b) Clean all grease laden surfaces frequently. To reduce the risk of fire and to disperse air
properly, make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, crawl spaces or garages.
NOTE - This warranty is invalid without an authorized agent’s receipt or if unit is
- KOBE RANGE HOODS will not be held responsible for any damages to
: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL
INJURY, OBSERVE THE FOLLOWING:
damaged due to misuse, poor installation, improper use, mistreatment, negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents. Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty.
personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.
WARNING: TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE TOP
GREASE FIRE:
- Keep all fan, baffle/spacer/filter/oil tunnel/oil container and grease-laden surfaces clean. Grease should not be allowed to accumulate on fan, baffle/spacer/filter/oil tunnel/oil container.
- Always turn hood ON when cooking.
- Use high settings on cooking range ONLY when necessary.
- Do not leave cooking range unattended when cooking.
- Always use cookware and utensils appropriate for the type and amount of food prepared.
- Use this unit only in the manner intended by the manufacturer.
- Before servicing, switch power off at service panel and lock service panel (if possible) to prevent power from switching on accidentally.
-
Clean ventilating fan frequently.
1
What to Do In The Event Of a Range Top Grease Fire
SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911.
NEVER PICK UP A BURNING PAN – You May Get Burned.
DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result.
Use an extinguisher ONLY if: a) You have a Class A, B, C extinguisher and know how to operate it. b) The fire is small and contained in the area where it started. c) The fire department has been called. d) You can fight the fire with your back to an exit.
What to Do If You Smell Gas
-
Extinguish any open flame.
-
Do not try to turn on the lights or any type of appliance.
-
Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company and Fire Department right away.
CAUTION
1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors.
2) To reduce the risk of fire, use only metal ductwork. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) to prevent back drafting.
3) Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities.
4) Activating any switch on may cause ignition or an explosion.
5) Due to the size and weight of this hood, two people installation is recommended.
ELECTRICAL SHOCK HAZARD – Can result in serious injury or death. Disconnect appliance from electric power before servicing. If equipped, the fluorescent light bulb contains small amounts of mercury, which must be recycled or disposed of according to Local, State, and Federal Codes.
2
COMPONENTS OF PACKAGE
(Must keep all material for returns or refunds)
Box 1 of 3 Box 2 of 3
{A} KOBE Range Hood {B} Warranty Registration Card {C} Instruction Manual {D} Stainless Filter – 1 {E} Stainless Steel Collar– 1
{A}
{B} {C}
{F} Glass Canopy – 1
Box 3 of 3
{G}Screws Package – 1 {H} One Piece Duct Cover – 1 {I} Mounting Bracket – 1 {J} Mounting Template
All screws attached to units
{G}
{H}
{I} {J}
{D} {E}
OPTIONAL RECIRCULATING KIT AVAILABLE. FOR MORE INFORMATION, PLEASE VISIT OUR WEBSITE
:::.2%(5DQJH+RRGV&20
OR CONTACT KOBE RANGE HOODS AT (626) 775-8880.
3
INSTALLATION
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
Calculation before Installation
To calculate installation, please refer to TABLE 1. (All calculation in inches.)
TABLE 1
A = Height of Floor to Ceiling B = Height of Floor to Counter Top
(Standard: 36")
C = Preferred Height of Counter Top to Hood
Bottom (Recommended 30" to 36")
D = Height of Hood E = Height of the Hood Installation [A – (B+C)] F = Height of Duct Cover [E – D]
SAFETY WARNING
HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.
NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD
MAY OCCUR.
4
Preparation before Installation
NOTE: TO AVOID DAMAGE TO YOUR HOOD,
PREVENT DEBRIS FROM ENTERING THE VENT OPENING.
Decide the location of the venting pipe from the hood to the outside. (Figure 1)
A straight, short vent run will allow the hood to perform more efficiently.
Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood.
Temporarily wire the hood to test for proper operation before installing.
Important: Peel protective film off the hood and duct covers, if any.
Use duct tape to seal the joints between pipe sections.
Advance Planning
1. Mark centerlines of cook top or range on ceiling. Use centerlines marked on ceiling to position the mounting template as shown in Figure 2 and 3.
2. Remove and save template. Cut and remove ceiling drywall. Install 2” x 4” cross framing lumbers (not provided) between ceiling joists.
3. The framing should be spaced 10-1/8” at the front centerline and 8-3/4” on the sides to accept the mounting screw in mounting bracket. Refer to MEASUREMENTS & DIAGRAMS on pages 12.
Figure 1
Figure 2
Figure 3
4. Finish the ceiling surface. Be sure to mark the location of the ceiling joists and cross framing lumber.
5. Align the mounting template to the ceiling marks and tape in place. Cut the 6-1/4” duct open and an approximately 1” wire access hole. Drill holes for the 6 mounting screws as indicated on the template.
6. Align the mounting bracket to the pre-drilled holes on the ceiling and securely fasten to the joists and cross framing lumber with 6 screws (not provided). Make sure screws are driven into the center of joists and cross framing lumber for maximum support.
5
Wiring to Power Supply
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.
7. Route house wiring into the ceiling as close to the installation location as possible. Allow additional length to drop down from the ceiling to the electrical box.
8. Connect the electrical wires according to color (black to black, white to white, and green to green) and cap with wire connectors. Green wire must be grounded to reduce risk of electrical shock.
Figure 4
Figure 5
Ductwork Installation
9. Use 6” round aluminum or steel pipe (not provided) to connect the 6” round damper on the hood to the ductwork above. NOTE: Place 6” round duct pipe over the damper. Seal with duct tape to make all joints secure and tight. NOTE: MAKE SURE FLAPS ON DAMPER CAN OPEN & CLOSE FREELY. (Figure 6)
Figure 6
6
Duct Cover Installation
10. Slide glass canopy onto the blower system. Secure glass on the top of range hood with 4 (M5 x 20) screws and 4 washers (provided). (Figure 5)
11. Slide duct cover onto the blower unit, secure underneath the blower unit with 4 (M8) nuts and 4 washers (provided). Refer to Figure 6 and 7.
12. Carefully slide stainless steel collar through duct cover to the top of glass carefully. Refer to Figure 8.
13. With assistance, align the duct cover to the mounting bracket and secure with 5 (M5 x
10) screws (provided). Refer to Figure 9.
Important: Make sure the hood orientation is correct before securing the hood.
14. Slide stainless steel collar towards the top of the duct cover. Refer to Figure 10.
15. Lock stainless steel collar to left or right to secure the stainless steel collar.
16. Peel protective film off the stainless steel collar.
17. Place stainless steel filter in place.
Figure 7
Figure 8
Final Assembly
18. Turn power ON and check all lights and fan operation.
19. Make sure to leave this manual for the homeowner.
Figure 9
Figure 10
7
OPERATION INSTRUCTIONS
This KOBE hood is equipped with five touch buttons, double horizontal squirrel cages with stainless steel filter, and four bright 12-volt /20-watt halogen lights.
The five touch buttons are Power Control (On/Off), Speed Control (High, Medium, & Low), and Light Control.
Note: For best results, turn hood to low speed prior to any preparation or cooking. Adjust speed as needed.
Power Control
Press Power Control to turn On/Off the hood.
This unit is equipped with 1-minute delay shutoff. To activate this feature, press Power Control button once, panel lights will flash and power will be completely shut off after 1 minutes.
Press Power Control button twice, the fan will be shut off immediately.
Speed Control
Press Speed Control to activate Low, Medium, or High Speed.
Light Control
(Light control is separate from ON/OFF control. Turning power off will not turn lights off.)
Press Light control to turn lights ON or OFF.
8
MAINTENANCE
SAFETY WARNING
NEVER PUT YOUR HAND INTO AREA HOUSING THE FAN WHILE THE FAN IS OPERATING.
CAUTION
:
NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. DO NOT USE PAPER TOWEL ON STAINLESS STEEL.
For optimal operation, clean range hood and all baffle/spacer/filter/oil tunnel/oil container regularly.
*** Regular care will help preserve the appearance of the hood.
1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth.
2. If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface
of the hood. Avoid getting cleaning solution onto or into the control panel. Follow directions of the stainless steel cleaner. Caution: Do not leave on too long as this may cause damage to hood finish. Use soft towel to wipe off the cleaning solution, gently rub off any stubborn spots. Use dry soft towel to dry the hood.
3. DO NOT allow deposits to accumulate or remain on the hood.
4. DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface
and cause rusting.
5. DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in
contact with stainless steel for extended periods. Many of these compounds contain chemicals, which may be harmful. Rinse with water after exposure and wipe dry with a clean lint free cloth.
To Clean Baffle, Spacer, Filter, Oil Tunnel and Oil Container
CAUTION
: DRAIN OIL FROM BAFFLES, SPACER(S), FILTERS, OIL TUNNEL(S) AND OIL
CONTAINERS BEFORE OIL AND RESIDUE CAN OVERFLOW.
Cleaning Baffle Filters
1. Remove all baffles, spacer(s), and oil tunnel(s). Follow directions on page 7 in reverse.
2. Discard oil and residue.
3. Wash with warm soapy water. Dry thoroughly before replacing.
(Note: Stainless Steel Baffles, Spacer(s) & Oil Tunnel are top rack dishwasher safe.)
9
To Replace Halogen Light Bulbs
CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL.
NOTE: DO NOT TOUCH HALOGEN LIGHT WITH BARE HANDS, WHICH MIGHT CAUSE OVER HEAT AND SHORTEN THE LIFT OF LIGHT BULBS.
 
1. Make sure all controls are OFF, and range hood is unplugged.
2. Place the flat-head screwdriver into the groove between the halogen light glass covering and
the housing .
3. Gently separate glass covering from the housing .
4. Gently pull out the defective light bulb and discard. Light bulbs should be 12V 20W
maximum.
5. Wear a glove or use a cloth to hold the new light bulb and push securely into light socket.
NOTE: DO NOT PUSH TOO HARD OR YOU MAY BREAK THE BULB CONNECTOR.
6. Put back halogen light glass cover .
7. Plug back power cord and turn on range hood to test for operation.
10
SPECIFICATIONS
BOX 1 OF 3 MODEL / SIZE
BOX 2 OF 3 MODEL / SIZE
Box 3 OF 3 MODEL / SIZE
COLOR
CONSUMPTION / AMPERE
VOLTAGE
FAN TYPE
DESIGN
EXHAUST
CONTROLS
IS20S – Blower Unit
IS2036GS / 36" – Glass Canopy IS2042GS / 42" – Glass Canopy
IS20DC-28 – 27-1/4” Ht. Duct Cover IS20DC-40 – 39-1/4” Ht. Duct Cover
Commercial Grade Stainless Steel
270W / 3.0A
120V 60Hz
Single Horizontal Squirrel Cage
20-Gauge Seamless / Satin Finish
Top 6" Round with Damper
5 Touch-Button (1-Minute Delay Shut Off)
HALOGEN LIGHTS
HOOD DIMENSION (W x D x H)
HOOD DIMENSION (With Glass and Duct Cover) (W x D x H)
OPTIONAL ACCESSORIES
(SOLD SEPARATELY)
Net WEIGHT (lbs) (IS2036GS) (IS2042GS) (IS20DC-28)
SPEED Low Medium High Air Capacity (cfm) Sone (dB)
Dimension of the hood height depends on the choice of the required duct cover.
12V 20W x 4
18-7/8" x 18-7/8" x 2-1/2"
35-3/4" x 27" x (30" or 42")*
41-3/4" x 27" x (30" or 42")*
Recirculating Kit – Item No. RD-0020
Gross
18.7 30.8
22.0 34.8
9.9
(IS20DC-40) (IS20S)
200 280 420
1.4 (45dB) 2.8 (55dB) 5.4 (64dB)
13.2
13.2
19.8
28.6
17.6
Specifications subject to change without notice.
11
MEASUREMENTS & DIAGRAMS
All ( ) measurements are in millimeter. All inch measurements are converted from millimeter. Inch measurements are estimated.
***Mounting Template
12
PARTS LIST
MODEL NO.: IS2036GS
IS2042GS
(Box 1 of 3)
ITEM NO. IS20S (Blower Unit)
NO. DESCRIPTION MODEL PART NO.
01 Wiring Box ISL120-1 02 Light Transformer ISL120-2 03 Capacitor ISL120-3 04 Processor Board ISL120-4 05 Electronic Support Panel ISL120-5 06 Wiring Box Cover ISL120-6 07 6” Round Damper ISL120-7 08 Air Chamber Support ISL120-8 09 Stainless Steel Collar ISL120-10 10 Motor ISL120-12 11 Motor Cover ISL120-13 12 Air Chamber ISL120-14 13 Squirrel Cage ISL120-15 14 Locknut ISL120-16 15 Blower Cover with Safety Screen ISL120-17 16 Round Body ISL120-19 17 Stainless Steel Filter ISL120-20 18 Halogen Light ISL120-21 19 Control Unit ISL120-22 20 Control Unit Cover ISL120-23
(Box 2 of 3)
MODEL NO. IS2036GS / IS2042GS (Glass)
NO. DESCRIPTION MODEL PART NO.
IS2036GS ISL120-18 21 Glass Canopy IS2042GS ISL120-18-1
(Box 3 of 3)
ITEM NO. IS20DC-28 / IS20DC-40 (Duct cover)
NO. DESCRIPTION MODEL PART NO.
IS20DC-28 ISL120-11 22 Duct Cover IS20DC-40 ISL120-11-1
23 Mounting Bracket ISL120-9
RECIRCULATING KIT – ITEM NO. RD-0020 (OPTIONAL)
NO. DESCRIPTION MODEL PART NO.
24 Box ISL120-A 25 Exhaust Adapter ISL120-B 26 Carbon Filter ISL120-C
13
MODEL NO.: IS2036GS
IS2042GS
RECIRCULATING KIT Item No. RD-0020
Sold Separately
14
CIRCUIT DIAGRAM
MODEL NO.: IS2036GS
IS2042GS
15
Trouble Shooting
Issue Possible Cause Solution
After Installation, both motors and lights are not working.
The power is not on. Make sure the circuit breaker and the unit’s power is
ON. Use a voltage meter to check the power supply. The wire connection is not secure. Check and tighten wire connection. The control panel and processor board wiring are disconnected. The motor transformer is defective. Check the power input and power output on the
Check wire continuity from control panel to processor
board.
motor transformer.
If it’s needed, replace the motor transformer.
Lights are working, but motor(s) is not.
The range hood is vibrating.
The motor is working, but the lights are not working.
The range hood is not venting out correctly.
The control panel and processor board is defective.
Replace the control panel or processor board.
The motor(s) is defective. Replace the motor. The capacitor(s) is defective. Replace capacitor(s). The control panel or processor board is
Replace the control panel or processing board. defective. The blower system is not secure. Tighten the turbine impeller/squirrel cage and air
chamber. The turbine impeller/squirrel cage is
Replace the turbine impeller/squirrel cage. not balanced. Hood is not secured in place. Check the installation of hood, tighten the
mounting bracket. Halogen Light bulb(s) is defective. Try placing the trouble light bulb(s) to a working
socket, if the bulb(s) still doesn’t work; replace
the halogen light bulb(s). The light wiring(s) is loose. Check wire continuity from processor board to
light transformer to halogen light housing(s). Light transformer is defective. Check power input and power output on the light
transformer. If it’s needed, replace the light
transformer. The control panel or processor board is
Replace the control panel or processing board. defective.
The range hood is installed outside of the manufacture recommended clearance.
Adjust the clearance between the range hoods
and cook top to 27” to 30”. For Island range
hood, the clearance between the range hoods
and cook top is 30” to 36”. There is no make-up air inside the house.
Open the window to enhance the performance
of the range hood by creating a sufficient make-
up air. Obstacle blocking the pipe work. Remove all obstacles from the duct work.
Cold air is coming into the
home.
The pipe size is smaller than the suggested pipe size. The pipe connection is not properly
Change the ducting according to the
manufacture suggestion.
Check the pipe installation. sealed. The damper is not properly installed or
Check the damper installation. is missing from the installation. The damper is not installed. By installing the damper, it will help to eliminate
air backflow.
16
DISCLAIMER
1. CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING DELIVERY. NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT. REQUEST NAME AND SIGNATURE OF THE CARRIER’S AGENT AND KEEP COPY TO SUPPORT YOUR CLAIM.
Upon acceptance of items, owner assumes responsibility for its safe arrival. Report damages to the carrier and file a claim immediately. Failure to do so may result in the denial of your claim. The carrier will furnish you with necessary forms for filing a claim.
DAMAGES CAUSED DURING TRANSIT ARE NOT COVERED UNDER OUR WARRANTY.
2. PLEASE INSPECT CONTENTS OF PACKAGE(S) CAREFULLY UPON RECEIVING!
We must be notified in writing of any damages and/or missing parts within the allocated days upon
your receipt of package(s). Contact your local KOBE dealer or distributor or call KOBE for the time limit.
CLAIMS WILL NOT BE ACCEPTED AFTER THE ALLOCATED DAYS.
NOTE: ITEMS WERE THOROUGHLY TESTED AND CAREFULLY PACKED IN OUR FACTORY
BEFORE SHIPPING.
3. Products must be returned in good working condition with ALL original parts and documentation packed in ALL original cartons, fillers and shipping cartons. A restocking fee of 25% will be charged for all approved return(s).
EXCHANGES OR RETURNS MAY NOT BE ACCEPTED IF ANY PACKAGING IS MISSING.
4. MAKE SURE TO INSPECT THE HOOD FOR DAMAGES AND DEFECTS BEFORE INSTALLATION. Appearance flaws of the hood found after installation and not affecting hood
performance is not covered under our warranty for returns or exchanges. Service visits not covered under warranty will carry a service charge.
A)
Before Installation: Return for exchange or refund (please see above for acceptable
returns).
B)
After Installation: NO exchange or refund.
17
WARRANTY
WARRANTY CERTIFICATE
KOBE Range Hoods, Inc. warrants all products manufactured or supplied by it to be free from defects in workmanship and materials. Its obligations pursuant to this warranty are limited to a period of two years from the date of purchase and to the repair or replacement at its option and subject to the terms and conditions stated below, of any component part, which its examination shall disclose to be so defective.
TWO-YEAR WARRANTY SERVICE PERIOD
Any covered failure occurring within two years of original purchase arising from defective workmanship or material in manufacture will be repaired (or at our discretion, replaced) free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods as applicable. Keep proof of purchase (or original invoice) handy for inspection.
If the range hood is sold by the original purchaser during the warranty period the new owner is protected until expiration of the original purchaser’s warranty.
CONDITIONS
The following conditions apply only in relation to the warranty expressly given in this certificate.
1) This warranty applies only:
a)
within U.S.A. and Canada.
b)
to range hoods used for PRIVATE SINGLE FAMILY USE (if used for COMMERCIAL or MULTIPLE FAMILY USE or other purposes, warranty will be voided).
2) Repair of any fault to be provided under this warranty shall not be provided:
a)
if the identification number attached to the range hood has been altered, rendered illegible or removed;
b)
if notice of the defect has not been given within the period applicable;
c)
for failure of light bulbs or heat lamps;
d)
for physical damage;
e)
for surfaces damaged by use of improper chemical cleaning agents;
f)
if the appliance has been: i) subject to misuse, abuse, negligence, accident, incorrect installation or failure to follow the
operating instructions;
ii) connected to improper, inadequate or faulty electricity service or exhaust ducts, flues or duct
cover, or operated using incorrect or contaminated lubricants;
iii) installed, maintained or operated otherwise than in accordance with the instructions
furnished by KOBE Range Hoods including the improper use of detergents, bleaches, or cleaners.
g)
for damage to range hood during transit, delivery, installation or removal;
h)
for damage by or resulting from attempted repairs conducted by anyone other than our Authorized Service Agent.
i)
noise or vibration caused by improper installation of range hood and/or damper.
18
3) The purchaser shall be responsible for any expenses involved in making the range hood readily accessible for servicing and where the range hood is installed outside the main sales territory of the retailer or service territory of the nearest approved KOBE Range Hoods Agent as applicable, for any traveling expenses and any costs of transporting the range hood or parts thereof to and from the dealer or Service Agent
4) The purchaser must produce proof of purchase together with this warranty certificate when making the claim.
5) Damages caused during shipment are not covered under our warranty.
CONSEQUENTIAL DAMAGE
The warrantor is not responsible for any consequential damage. SOME STATES DO NOT ALLOW THE EXCLUSION OF CONSEQUENTIAL DAMAGE SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU.
IMPLIED WARRANTIES/STATE LAW
Any implied warranties, including the implied warranty of merchantability and fitness for purpose, imposed on the sale by the laws of the state of sale are limited to two year from the date of original purchase. Some states do not allow limitations on the duration of implied warranties. This warranty gives you specific legal rights, and may also have rights, which vary from state to state.
SERVICE
For service contact:
KOBE Range Hoods 11775 Clark Street Arcadia, CA 91006 U.S.A. Tel: (626) 775-8880 Email: customer.service@KOBERangeHoods.com Website: www.KOBERangeHoods.com
19
PRODUCT REGISTRATION
Register Your Product!
Any covered failure occurring within two years of original purchase arising from defective workmanship or material in manufacture will be repaired or at our option the unit will be replaced free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods as applicable. Keep proof of purchase (original invoice) handy for inspection.
If the range hood is sold by the original purchaser during the warranty period the new owner is protected until expiration of the original purchaser’s warranty. See warranty section for complete warranty coverage information.
This appliance has been manufactured, tested, and inspected to the standards required by KOBE Range Hoods.
PLEASE MAIL IN YOUR WARRANTY REGISTRATION CARD AND PROOF OF PURCHASE TO:
KOBE Range Hoods
Warranty Registration 11775 Clark Street Arcadia, CA 91006 U.S.A.
RECORD THE FOLLOWING INFORMATION FOR YOUR RECORD:
Model No. ___________________________________________________
Serial No. ___________________________________________________
Purchased Date ____ / ______ /
Purchased From:
____________________________
____________________________
____________________________
IMPORTANT: PLEASE KEEP A COPY OF YOUR SALE RECEIPT OR INVOICE HANDY WHEN
REQUESTING SERVICE.
20
Loading...