Kobe CH0342SQB User Manual

Model No. / N
CH0330SQB CH0336SQB CH0342SQB CH0348SQB
KOBE Brand Range Hood
os
de modèles / Modelo No.
CH-03 SERIES – 18” HEIGHT
  
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
MANUEL D'INSTALLATION
ET MODE D'EMPLOI
INSTRUCCIONES DE INSTALACIÓN
Y MANUAL DE OPERACIÓN
      
[ENGLISH] ..................................................................................................................................1
[FRENCH] .................................................................................................................................28
[SPANISH] ................................................................................................................................55



- READ AND SAVE THESE INSTRUCTIONS -
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS .....................................................................................2
COMPONENTS OF PACKAGE...................................................................................................4
INSTALLATION ...........................................................................................................................5
OPERATION INSTRUCTIONS..................................................................................................12
MAINTENANCE ........................................................................................................................13
SPECIFICATIONS ....................................................................................................................15
MEASUREMENTS & DIAGRAMS .............................................................................................16
PARTS LIST ..............................................................................................................................18
CIRCUIT DIAGRAM ..................................................................................................................21
TROUBLE SHOOTING .............................................................................................................23
DISCLAIMER ............................................................................................................................24
WARRANTY .............................................................................................................................25
PRODUCT REGISTRATION .....................................................................................................27
- READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING -
ALL WIRING MUST BE DONE BY A PROFESSIONAL AND IN
ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES.
1
IMPORTANT SAFETY INSTRUCTIONS
- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -

1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction.
2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities.
3) Ducted fans must be vented to the outside. a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT SERVICE
PANEL.
b) Clean all grease laden surfaces frequently. To reduce the risk of fire and to disperse air
properly, make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, crawl spaces or garages.
NOT E - This warranty is invalid without an authorized agent’s receipt or if unit is
- KOBE RANGE HOODS will not be held responsible for any damages to
:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING:
damaged due to misuse, poor installation, improper use, mistreatment, negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents. Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty.
personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.



1. Keep all fan, baffle/spacer/filter/oil tunnel/oil container and grease-laden surfaces clean. Grease should not be allowed to accumulate on fan, baffle/spacer/filter/oil tunnel/oil container.
2. Always turn hood ON when cooking.
3. Use high settings on cooking range ONLY when necessary.
4. Do not leave cooking range unattended when cooking.
5. Always use cookware and utensils appropriate for the type and amount of food prepared.
6. Use this unit only in the manner intended by the manufacturer.
7. Before servicing, switch power off at service panel and lock service panel (if possible) to prevent power from switching on accidentally.
8. Clean ventilating fan frequently.
 
: TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE
TOP GREASE FIRE:
2
What to Do In The Event Of a Range Top Grease Fire
SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911.
NEVER PICK UP A BURNING PAN – You May Get Burned.
DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result.
Use an extinguisher ONLY if: a) You have a Class A, B, C extinguisher and know how to operate it. b) The fire is small and contained in the area where it started. c) The fire department has been called. d) You can fight the fire with your back to an exit.
What to Do If You Smell Gas
-
Extinguish any open flame.
-
Do not try to turn on the lights or any type of appliance.
-
Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company and Fire Department right away.

1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors.
2) To reduce the risk of fire, use only metal ductwork. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) to prevent back drafting.
3) Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities.
4) Activating any switch on may cause ignition or an explosion.
5) Due to the size and weight of this hood, two people installation is recommended.
  

ELECTRICAL SHOCK HAZARD – Can result in serious injury or death. Disconnect appliance from electric power before servicing. If equipped, the fluorescent light bulb contains small amounts of mercury, which must be recycled or disposed of according to Local, State, and Federal Codes.
 
    
3
COMPONENTS OF PACKAGE
(Must keep all material for returns or refunds)
RANGE HOOD BOX
c
KOBE Range Hood – 1
d
Warranty Registration Card –1
e
Instructions Manual – 1
f
Baffle Filter
- 2 (30”, 36”, 42”)
- 3 (48”)
g
Stainless Steel Spacer
- 1 (30”)
- 3 (36”)
- 3 (42”)
- 2 (48”)
h
Oil Tunnel – 1
i
Ducting Transition – 1
j
Screw Package for Transition – 1
k
Hood-Mounting Bracket-2
l
Screw Package for Hood-Mounting Bracket–1
c
d
j
k l
ORIGINAL KIT
(Sold Separately)
Option Of:
Model No. CH0030DC-12 for 30'' hood
KOBE Duct Cover – 1 Screw Package for Duct Cover - 1
Hood-Mounting Bracket-2
e
f
h
i
g
Model No. CH0036DC-12 for 36'' hood
KOBE Duct Cover – 1 Screw Package for Duct Cover - 1
Hood-Mounting Bracket-2
Model No. CH0042DC-12 for 42'' hood
KOBE Duct Cover – 1 Screw Package for Duct Cover - 1 Hood-Mounting Bracket-2
Model No. CH0048DC-12 for 48'' hood
KOBE Duct Cover – 1 Screw Package for Duct Cover - 1
Hood-Mounting Bracket-2
3/16" X 3/8" (8 pc)
-
FOR MORE INFORMATION, PLEASE VISIT OUR WEBSITE www.KOBERangeHoods.com OR CONTACT KOBE RANGE HOODS AT (626-775-8880).
4
INSTALLATION
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
Calculation before Installation
Calculate the length of the installation, before installing the hood. (All calculation is measure in inches.)
- FOR UNDER THE CABINET -
TABLE 1
A = Height of Floor to Ceiling B = Height of Floor to Counter Top
(Standard: 36”)
C = Preferred Height of Counter Top to Hood
Bottom (Recommended 27” to 30”)
D = Height of Hood E = Height of the Cabinet
- FOR WALL MOUNT (WITH OPTIONAL DUCT COVER) -
TABLE 2
A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”)
C = Preferred Height of Counter Top to Hood
Bottom (Recommended 27” to 30”)
[(A – B] – (D + E)]
D = Height of Hood E = Height of Duct Cover
  
5
              

HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.
NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR.
 
Installation Contents
UNDER THE CABINET INSTALLATION ............................................................................................... 7
WALL MOUNT INSTALLATION ............................................................................................................. 9
   
6
UNDER THE CABINET INSTALLATION
Preparation before Installation
NOTE: TO AVOID DAMAGE TO YOUR HOOD,
PREVENT DEBRIS FROM ENTERING THE VENT OPENING.
Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1.
A straight, short venting run will allow the hood to perform more efficiently.
Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood.
Temporarily wire the hood to test for proper operation before installing.
Important: Peel protective film off the hood (if any).
For installing under the cabinet with recessed bottom, attach 4-inch wide wood filler strips (not included) on each side. Refer to Figure 2.
Measure and create access opening for electrical wires under the cabinet.
Figure 1
Figure 2
Hood Installation
CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE.
1. Puncture the knockout holes on the hood as shown in Figure 3.
2. Attach ducting transition to hood exhaust with ten (3/16” x 3/8”) screws (included). Shown in Figure 4.
3. Using references on Table 1 and measurements on page 16-17 to center the hood in place beneath the cabinet and flush with the front of the cabinet.
4. Draw electrical wires through cabinet access opening.
5. From the bottom of the hood, place screw (not provided) into the exact center of each knockout hole. Make sure all screws are in place before tightening screws. CAUTION:
MAKE SURE THE HOOD IS SECURE BEFORE RELEASING.
6. For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure installation, use as many mounting holes as needed to secure from the inside of hood (screws not included).
7
Figure 3
Figure 4
Duct Cover Installation
5. Use 8” round steel pipe (follow building codes in your area) to connect the ducting transition on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer Figure 15. Slide the duct cover onto the hood.
6. Use 3/16” x 3/8” screws (included) to attach duct cover to hood.
Figure 15
Install Accessories
7. Attach oil tunnel. Refer to Figure 16.
8. Refer to Figure 17. c Slide the baffle filter into the hood. d Push the baffle filter upward. e Slide forward. f Pull downward. g Fit into place.
9. For bottom casing, repeat above steps. Refer to page 17.
10. Install heating lamps (not included), 120 Volts 175 Watts max. each.
Final Assembly
11. Turn power ON in control panel. Check all lights and fan operation.
12. Make sure to leave this manual for the homeowner.
Figure 16
Figure 17
11
OPERATION INSTRUCTIONS
This KOBE hood is equipped with two rotary controls with powerful centrifugal squirrel cage, baffle filters, and bright 12-volt 20-watt halogen lights.
The two rotary controls are Light Control & Speed Control. Refer to Figure 18.
Figure 18
Note: For best results, turn hood to QuietMode™ prior to preparation or cooking to
establish airflow in the kitchen. Adjust speed as needed.
x
Rotate the Speed Control clockwise to cycle from QuietMode¥¥¥¥, Low, Medium, High, and Off; and rotate counterclockwise to cycle from High, Medium, Low, QuietMode¥¥¥¥, and off
x
Rotate the Light Control clockwise to cycle the light intensity through low, medium, high, and off.
x
Press the back Red button to turn on heating lamp.
(Note: Heating lamps are sold separately. Heating lamps required 120-volt, 175-watt.)
12
MAINTENANCE
For the optimal level of operation, clean the range hood surface and baffles regularly.
To Clean Hood Surface
CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS.
*** Regular care will help preserve its fine appearance.
1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth.
2. If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting cleaning solution onto or into the control panel. Follow directions of the stainless steel cleaner. Caution: Do not leave on too long as this may cause damage to hood finish. Use soft towel to wipe off the cleaning solution, gently rub off any stubborn spots. Use dry soft towel to dry the hood.
3. DO NOT allow deposits to accumulate or remain on the hood.
4. DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting.
5. DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals, which may be harmful. Rinse with water after exposure and wipe dry with a clean lint free cloth.
To Clean Baffle Filters & Oil Tunnel
CAUTION: DRAIN BAFFLE FILTERS AND OIL TUNNEL BEFORE OIL WILL OVERFLOW.
1. Remove the baffle filters and oil tunnel.
2. Using a sponge, wash with warm soapy water. Dry completely before returning into place.
(Note: Baffle Filters are top rack dishwasher safe.)
13
Replacing Light Bulb
CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL.
cccc
1. Make sure all controls are off, and range hood is unplugged.
2. Place the flat-headed screwdriver into the groove of the halogen light glass covering and the housing.
3. Pop out the halogen light glass covering.
4. Gently pull out the defective light bulb and discard. Light bulbs should be 12V 20W maximum.
5. Using a cloth, hold the new light bulb and push securely into light socket.
6. Return halogen light glass cover to the housing.
7. Turn range hood ON to test for operation.
cccc
eeee
dddd
dddd
ffff
eeee
ffff
14
SPECIFICATIONS
R
MODEL / SIZE
COLO CONSUMPTION / AMPERE
VOLTAGE NUMBER OF MOTORS
DESIGN FAN TYPE: CENTRIFUGAL EXHAUST CONTROLS
HALOGEN LIGHTS
HOOD DIMENSION (W x D x H)
CH0330SQB / 30” CH0336SQB / 36" CH0342SQB / 42” CH0348SQB / 48”
Commercial Grade Stainless Steel CH0330SQB – 300W / 2.68A
CH0336SQB – 300W / 2.68A CH0342SQB – 320W / 2.86A CH0348SQB – 320W / 2.86A 120V 60Hz
1
18-Gauge Seamless / Satin Finish Squirrel Cage Top Transition Rectangular to 8” Round Rotary Control
12V 20W x 2 – 30”, 36” 12V 20W x 3 – 42”, 48”
(CH0330SQB) 29-3/4” x 25” x 18” (CH0336SQB) 35-3/4” x 25” x 18” (CH0342SQB) 41-3/4” x 25” x 18” (CH0348SQB) 47-3/4” x 25” x 18”
OPTIONAL ACCESSORIES (W x D x H)
HOOD WEIGHT (lbs)
SPEED Air Capacity (cfm)* Sone
*In House Test Static Pressure “0”. One sone is equivalent to the sound of a refrigerator at 40 decibels. **Specifications subject to change without notice.
1) Original Kit - Duct Cover:
Model No. CH0030DC-12 30” x 12” x 12” Model No. CH0036DC-12 36” x 12” x 12” Model No. CH0042DC-12 42” x 12” x 12” Model No. CH0048DC-12 48” x 12” x 12”
2) Model No. SSP30
30” Stainless Steel Back Panel 30” x 1/10” x 32”
3) Model No. SSP36
36” Stainless Steel Back Panel 36” x 1/10” x 32”
Net (CH0330SQB) (CH0336SQB)
(CH0342SQB) (CH0348SQB)
QuietMode¥¥¥¥
400 600 800 1000
1.4* 3.5 7.0 8.0
66.0 84.0
73.0 93.0
84.0 106.0
90.5 115.0
Low Medium High
Gross
15
MEASUREMENTS & DIAGRAMS
All measurements in ( ) are millimeters.
All inch measurements are converted from millimeters. Inch measurements are estimated.
- FOR UNDER THE CABINET -
MODEL NO.: CH0330SQB
CH0336SQB CH0342SQB CH0348SQB
MODEL NO.: CH0330SQB
CH0336SQB CH0342SQB CH0348SQB
- FOR WALL MOUNT -
16
- FOR WALL MOUNT (WITH OPTIONAL DUCT COVER) -
***Rear Knocko ut Holes ***Hood-Mounting Bracket
 
       
17
PARTS LIST
Y
T
MODEL NO.: CH0330SQB
CH0336SQB CH0342SQB CH0348SQB
NO. DESCRIPTION MODEL /SIZE PART NO.
1 Ducting Transition FA-12001-0506-01 (B001-2) 2 Hood Casing CH0330SQB 10-2130
CH0336SQB 10-2136 CH0342SQB 10-2142 CH0348SQB 10-2148
3 Control Unit C1-0501-0101
4 Control Board C1-0404-0401-A 5 Halogen Light Unit (12V 20W Max.) C1-0403-0101 6 Motor FA-12001-0302-01 (B001-4.5) 7 Lamp Socket Cover C1-0204-2130 8 Lamp Socket C1-0414-0120 9 Safety Screen FA-12001-0602-01 (B001-4.2)
10 Capacitor Panel CH0330SQB C1-0201-2130
CH0336SQB C1-0201-2136 CH0342SQB C1-0201-2142 CH0348SQB C1-0201-2148 CH0330SQB C1-0402-0120-40
11 Transformer (Light)
12 Capacitor FA-12001-0401-01
13 Transformer (Motor) C1-0402-A-120-01 14 Processor Board Box C1-0501-0102 15 Processor Board C1-0404-0401-B 16 Screw (1/8” x 3/8”) C1-0708-0003 17 Baffle Filter B101-2130-15 18
Bottom Casing
A
4” Wide CH0030SQB B101-2130-09 4” Wide
B
3” Wide
C
5-1/4” Wide CH0042SQB B101-2142-09
D
4-1/2” Wide CH0048SQB B101-2148-09
CH0336SQB CH0342SQB C1-0402-0120-60 CH0348SQB
CH0036SQB CH0036SQB B101-2136-09
BLOWER ASSEMBL
NO. DESCRIPTION MODEL /SIZE PART NO.
6-1 Screws (3/16” x 3/8”) B001-4.1 6-2 Left Locknut B001-4.3 6-3 Left Squirrel Cage B001-4.4 6-4 Right Squirrel Cage B001-4.6 6-5 Right Locknut B001-4.7 6-6 Air Chamber B001-4.8
(Optional Duct Cover)
ORIGINAL KI
NO. DESCRIPTION MODEL /SIZE PART NO.
01 Hood-Mounting Bracket C1-0221-0330 02 Screw (3/16” x 3/8”) C1-0707-0001 03 Duct Cover CH0030DC-12 B102-6012-030
CH0036DC-12 B102-6012-036 CH0042DC-12 B102-6012-042 CH0048DC-12 B102-6012-048
04 Screw (3/16” x 3/8”) C1-0707-0001
18
MODEL NO.: CH0330SQB
CH0336SQB
19
MODEL NO.: CH0342SQB
CH0348SQB
20
CIRCUIT DIAGRAM
MODEL NO.: CH0330SQB
CH0336SQB
21
MODEL NO.: CH0342SQB
CH0348SQB
22
TROUBLE SHOOTING
Issue Possible Cause Solution
After Installation, both motors and lights are not working.
The power is not on. Make sure the circuit breaker and the unit’s power is
ON. Use a voltage meter to check the power supply. The wire connection is not secure. Check and tighten wire connection. The control panel and processor board wiring are disconnected. The motor transformer is defective. Check the power input and power output on the
Check wire continuity from control panel to processor
board.
motor transformer.
If it’s needed, replace the motor transformer.
Lights are working, but motor(s) is not.
The range hood is vibrating.
The motor is working, but the lights are not working.
The control panel and processor board is defective.
Replace the control panel or processor board.
The motor(s) is defective. Replace the motor. The capacitor(s) is defective. Replace capacitor(s). The control panel or processor board is
Replace the control panel or processing board. defective. The blower system is not secure. Tighten the turbine impeller/squirrel cage and air
chamber. The turbine impeller/squirrel cage is
Replace the turbine impeller/squirrel cage. not balanced. Hood is not secured in place. Check the installation of hood, tighten the
mounting bracket. Halogen Light bulb(s) is defective. Try placing the trouble light bulb(s) to a working
socket, if the bulb(s) still doesn’t work; replace
the halogen light bulb(s). The light wiring(s) is loose. Check wire continuity from processor board to
light transformer to halogen light housing(s). Light transformer is defective. Check power input and power output on the light
transformer. If it’s needed, replace the light
transformer. The control panel or processor board is
Replace the control panel or processing board. defective.
The range hood is not venting out correctly.
Cold air is coming into the
home.
The range hood is installed outside of the manufacture recommended clearance.
Adjust the clearance between the range hoods
and cook top to 27” to 30”. For Island range
hood and professional series range hood, the
clearance between the range hoods and cook
top is 30” to 36”. There is no make-up air inside the house.
Open the window to enhance the performance
of the range hood by creating a sufficient make-
up air. Obstacle blocking the pipe work. Remove all obstacles from the duct work.
The pipe size is smaller than the suggested pipe size. The pipe connection is not properly
Change the ducting according to the
manufacture suggestion.
Check the pipe installation. sealed.
23
DISCLAIMER
1. CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING DELIVERY. NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT. REQUEST NAME AND SIGNATURE OF THE CARRIER’S AGENT AND KEEP COPY TO SUPPORT YOUR CLAIM.
Upon acceptance of items, owner assumes responsibility for its safe arrival. Report damages to the carrier and file a claim immediately. Failure to do so may result in the denial of your claim. The carrier will furnish you with necessary forms for filing a claim.
DAMAGES CAUSED DURING TRANSIT ARE NOT COVERED UNDER OUR
WARRANTY.
2. PLEASE INSPECT CONTENTS OF PACKAGE(S) CAREFULLY UPON RECEIVING!
We must be notified in writing of any damages and/or missing parts within the allocated days
upon your receipt of package(s). Contact your local KOBE dealer or distributor or call KOBE for the time limit.
CLAIMS WILL NOT BE ACCEPTED AFTER THE ALLOCATED DAYS.
NOTE: ITEMS WERE THOROUGHLY TESTED AND CAREFULLY PACKED IN OUR
FACTORY BEFORE SHIPPING.
3. Products must be returned in good working condition with ALL original parts and documentation packed in ALL original cartons, fillers and shipping cartons. A restocking fee of 25% will be charged for all approved return(s).
EXCHANGES OR RETURNS MAY NOT BE ACCEPTED IF ANY PACKAGING IS
MISSING.
4. MAKE SURE TO INSPECT THE HOOD FOR DAMAGES AND DEFECTS BEFORE INSTALLATION. Appearance flaws of the hood found after installation and not affecting
hood performance is not covered under our warranty for returns or exchanges. Service visits not covered under warranty will carry a service charge.
A)
B)
Before Installation: Return for exchange or refund (please see above for
acceptable returns).
After Installation: NO exchange or refund.
24
WARRANTY
WARRANTY CERTIFICATE
KOBE Range Hoods, warrants all products manufactured or supplied by it to be free from defects in workmanship and materials. Its obligations pursuant to this warranty are limited to a period of two years from the date of purchase and to the repair or replacement at its option and subject to the terms and conditions stated below, of any component part, which its examination shall disclose to be so defective.
TWO-YEAR WARRANTY SERVICE PERIOD
Any covered failure occurring within two years of original purchase arising from defective workmanship or material in manufacture will be repaired (or at our discretion, replaced) free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods as applicable. Keep proof of purchase (or original invoice) handy for inspection.
If the range hood is sold by the original purchaser during the warranty period the new owner is protected until expiration of the original purchaser’s warranty.
CONDITIONS
The following conditions apply only in relation to the warranty expressly given in this certificate.
1) This warranty applies only:
a)
within U.S.A. and Canada.
b)
to range hoods used for PRIVATE SINGLE FAMILY USE (if used for COMMERCIAL or MULTIPLE FAMILY USE or other purposes, warranty will be voided).
2) Repair of any fault to be provided under this warranty shall not be provided:
a)
if the identification number attached to the range hood has been altered, rendered illegible or removed;
b)
if notice of the defect has not been given within the period applicable;
c)
for failure of light bulbs or heat lamps;
d)
for physical damage;
e)
for surfaces damaged by use of improper chemical cleaning agents;
f)
if the appliance has been: i) subject to misuse, abuse, negligence, accident, incorrect installation or failure to
follow the operating instructions;
ii) connected to improper, inadequate or faulty electricity service or exhaust ducts, flues
or duct cover, or operated using incorrect or contaminated lubricants;
iii) installed, maintained or operated otherwise than in accordance with the instructions
furnished by KOBE Range Hoods including the improper use of detergents, bleaches, or cleaners.
g)
for damage to range hood during transit, delivery, installation or removal;
h)
for damage by or resulting from attempted repairs conducted by anyone other than our Authorized Service Agent.
i)
noise or vibration caused by improper installation of range hood and/or damper.
25
3) The purchaser shall be responsible for any expenses involved in making the range hood readily accessible for servicing and where the range hood is installed outside the main sales territory of the retailer or service territory of the nearest approved KOBE Range Hoods Agent as applicable, for any traveling expenses and any costs of transporting the range hood or parts thereof to and from the dealer or Service Agent
4) The purchaser must produce proof of purchase together with this warranty certificate when making the claim.
5) Damages caused during shipment are not covered under our warranty.
CONSEQUENTIAL DAMAGE
The warrantor is not responsible for any consequential damage. SOME STATES DO NOT ALLOW THE EXCLUSION OF CONSEQUENTIAL DAMAGE SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU.
IMPLIED WARRANTIES/STATE LAW
Any implied warranties, including the implied warranty of merchantability and fitness for purpose, imposed on the sale by the laws of the state of sale are limited to two year from the date of original purchase. Some states do not allow limitations on the duration of implied warranties. This warranty gives you specific legal rights, and may also have rights, which vary from state to state.
SERVICE
For service contact:
KOBE Range Hoods 11775 Clark Street Arcadia, CA 91006 U.S.A. Tel: (626) 775-8880 Email: customer.service@KOBERangeHoods.com Website: www.KOBERangeHoods.com
26
Loading...