Kobe CH0042SQBWM1 User Manual

KOBE Range Hoods
CH00 Series
Model No.
Under Cabinet:
Wall Mount: CH0030SQB-WM-1 (30”)
RA02 Series
Model No.
Wall Mount:
CH0030SQB-1 (30”) CH0036SQB-1 (36”) CH0042SQB-1 (42”) CH0048SQB-1 (48”)
CH0036SQB-WM-1 (36”) CH0042SQB-WM-1 (42”) CH0048SQB-WM-1 (48”)
RA0230SQB-1 / RA0230SQB-DC-1 (30”) RA0236SQB-1 / RA0236SQB-DC-1 (36”) RA0242SQB-1 / RA0242SQB-DC-1 (42”) RA0248SQB-1 / RA0248SQB-DC-1 (48”)
RA0230SQB-DC24-1 (30”) RA0236SQB-DC24-1 (36”) RA0242SQB-DC24-1 (42”) RA0248SQB-DC24-1 (48”)
RA0230SQB-DC48-1 (30”) RA0236SQB-DC48-1 (36”) RA0242SQB-DC48-1 (42”) RA0248SQB-DC48-1 (48”)
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
IMPORTANT
READ THIS FIRST
READ BEFORE INSTALLATION
1. Carefully check all contents of packages.
2. Thoroughly inspect the unit for any shipping damages, cosmetic damages or defects.
3. Have a certified contractor/electrician test the unit before installation.
IF THERE IS ANY PROBLEM:
1. DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL
PACKAGING MATERIAL.
2. Have your original invoice as proof of purchase and product serial number ready.
3. Contact your merchant for product replacement due to shipping damages, cosmetic damages or defects.
4. For all other issues, call 1-877-BUY-KOBE (289-5623), or e-mail to
info@koberangehoods.com .
NO RETURN, NO REFUND, NO EXCHANGE IF:
1. PRODUCT HAS BEEN INSTALLED
2. KNOCK-OUT HOLES HAVE BEEN PUNCTURED
3. MISSING ORIGINAL PACKAGING MATERIAL
AND/OR PARTS
[ENGLISH]
- READ AND SAVE THESE INSTRUCTIONS -
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS ..................................................................................... 1
COMPONENTS OF PACKAGE................................................................................................... 3
INSTALLATION ........................................................................................................................... 5
OPERATION INSTRUCTIONS.................................................................................................. 15
MAINTENANCE ........................................................................................................................ 16
SPECIFICATIONS .................................................................................................................... 17
MEASUREMENTS & DIAGRAMS ............................................................................................. 21
PARTS LIST .............................................................................................................................. 24
CIRCUIT DIAGRAM .................................................................................................................. 30
TROUBLE SHOOTING ............................................................................................................. 31
WARRANTY ............................................................................................................................. 32
PRODUCT REGISTRATION ..................................................................................................... 34
- READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING -
ALL WIRING MUST BE DONE BY A PROFESSIONAL AND IN ACCORDANCE WITH
NATIONAL AND LOCAL ELECTRICAL CODES.
IMPORTANT SAFETY INSTRUCTIONS
- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -
WARNING
:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING:
1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction.
2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities.
3) Ducted fans must be vented to the outside. a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT SERVICE
PANEL.
b) Clean all grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly,
make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, crawl spaces or garages.
NOTE - This warranty is invalid without an authorized agent’s receipt or if unit is
damaged due to misuse, poor installation, improper use, mistreatment, negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents. Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty.
- KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.
WARNING
1. Keep all fan, baffle/spacer/filter/oil tunnel/oil container and grease-laden surfaces clean. Grease should not be allowed to accumulate on fan, baffle/spacer/filter/oil tunnel/oil container.
2. Always turn hood ON when cooking.
3. Use high settings on cooking range ONLY when necessary.
4. Do not leave cooking range unattended when cooking.
5. Always use cookware and utensils appropriate for the type and amount of food prepared.
6. Use this unit only in the manner intended by the manufacturer.
7. Before servicing, switch power off at service panel and lock service panel (if possible) to prevent power from switching on accidentally.
8. Clean ventilating fan frequently.
: TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE
TOP GREASE FIRE:
1
What to Do In The Event Of a Range Top Grease Fire
SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911.
NEVER PICK UP A BURNING PAN – You May Get Burned.
DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result.
Use an extinguisher ONLY if: a) You have a Class A, B, C extinguisher and know how to operate it. b) The fire is small and contained in the area where it started. c) The fire department has been called. d) You can fight the fire with your back to an exit.
What to Do If You Smell Gas
-
Extinguish any open flame.
-
Do not try to turn on the lights or any type of appliance.
-
Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company and Fire Department right away.
CAUTION
1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors.
2) To reduce the risk of fire, use only metal ductwork. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) to prevent back drafting.
3) Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities.
4) Activating any switch on may cause ignition or an explosion.
5) Due to the size and weight of this hood, two people installation is recommended.
ELECTRICAL SHOCK HAZARD – Can result in serious injury or death. Disconnect appliance from electric power before servicing. If equipped, the fluorescent light bulb contains small amounts of mercury, which must be recycled or disposed of according to Local, State, and Federal Codes.
2
{H}
Duct Cover
(Included in Wall Mound Hood
COMPONENTS OF PACKAGE
(Must keep all material for returns or refunds)
CH00 Series RANGE HOOD BOX
{A} KOBE Range Hood {B} Warranty Registration Card {C} Quick Reference Guide {D} Oil Tunnel {E} Baffle Filter – 2 (30” & 36”)
{F} Spacer x 2 {G} 6” Round Plastic Collar (30” & 36”)
8” Round Exhaust Plate (42” & 48”)
{H} Screws Package {I} Hood-Mounting Bracket x 2 {J} Screws Package {K} Wire Cap x 3 {L} Screws Package (for Under Cabinet only)
{A}
{B} {C}
{D} {E}
{F} {G}
– 3 (42” & 48”)
{I} {J}
{K} {L}
Wire caps (3)
M4 x 3/4" (4 for 30” & 36”) (8 for 42” & 48”)
ONLY)
Option Of:
Model No. CH0030DC-12 for 30'' hood
Duct Cover Screw Package for Duct Cover
Model No. CH0036DC-12 for 36'' hood
Duct Cover Screw Package for Duct Cover
Model No. CH0042DC-12 for 42'' hood
Duct Cover Screw Package for Duct Cover
Model No. CH0048DC-12 for 48'' hood
Duct Cover Screw Package for Duct Cover
M4 x 1-1/2” (6)
M4 x 1-1/4” (4 for 30” & 36”) (8 for 42” & 48”)
3
RA02 Series
RANGE HOOD BOX
Inner Duct Extension
RA02DC
-24-1
Outer Duct Extension
RA02DC
-24
{A} KOBE Range Hood {B} Warranty Registration Card {C} Quick Reference Guide {D} Oil Tunnel {E} Baffle Filter x 2 (30” & 36”)
x 3 (42” & 48”) {F} Spacer {G} 8” Round Exhaust Plate (42” & 48” only) {H} Screws Package {I} Hood-Mounting Bracket {J} Screws Package {K} Duct Cover (Model No. RA02DC-1) {L} Wire Cap {M} Screws Package
{A}
{B} {C}
{D} {E}
{H}
{I} {J}
{K} {L}
Wire caps (3)
{M}
M4 x 1-1/2” (4)
(Included in RA02 SQB-DC24-1 and SQB-DC48-1)
{N} Inner Duct Extension
(Model No. RA02DC-24-1)
{O} Duct Cover Mounting Bracket {P} Screws Package
{N} {O} {P}
M4 x 1-1/2” (2)
{F} {G}
-
FOR MORE INFORMATION, PLEASE VISIT OUR WEBSITE www.koberangehoods.com OR CONTACT KOBE RANGE HOODS AT (626) 775-8880.
(Included in RA02 SQB-DC48-1 Only)
{Q} Outer Duct Extension
(Model No. RA02DC-24)
{Q}
4
TABLE 1
TABLE 2
CH00 Series
RA
02 Series
CH
00 Series
INSTALLATION
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
Calculation before Installation
Calculate the length of the installation, before installing the hood. (All calculation is measure in inches.)
- FOR UNDER THE CABINET -
A = Height of Floor to Ceiling B = Height of Floor to Counter Top
(Standard: 36”)
C =
Preferred Height of Counter Top to Hood
Bottom 30” & 36” Hood (Recommended 27” to 30”) 42” & 48” Hood (Recommended 30” to 36”)
D = Height of Hood E = Height of the Cabinet
- FOR STAND ALONE -
A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”)
C =
Preferred Height of Counter Top to Hood
Bottom 30” & 36” Hood (Recommended 27” to 30”) 42” & 48” Hood (Recommended 30” to 36”)
[(A – B] – (D + E)]
D = Height of Hood E = Height of Duct Cover
5
SAFETY WARNING
HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.
NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR.
CH00 SERIES – UNDER THE CABINET INSTALLATION ..................................................................7
CH00 SERIES – STAND ALONE INSTALLATION ..............................................................................9
RA02 SERIES – INSTALLATION ...................................................................................................... 12
6
Preparation before Installation
Hood Installation
CH00 SERIES – UNDER THE CABINET INSTALLATION
NOTE: TO AVOID DAMAGE TO YOUR HOOD,
PREVENT DEBRIS FROM ENTERING THE VENT OPENING.
Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1.
A straight, short venting run will allow the hood to perform more efficiently.
Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood.
Temporarily wire the hood to test for proper operation before installing.
Important: Peel protective film off the hood (if any).
For installing under the cabinet with recessed bottom, attach 4-inch wide wood filler strips (not included) on each side. Refer to Figure 2.
Measure and create access opening for electrical wires under the cabinet.
CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE.
1. Puncture the knockout holes on the hood as shown in Figure 3.
2. (This step only applies to 42” and 48” models.) Attach exhaust plate on hood with four (3/16” x 3/8”) screws (included). Shown in Figure 4.
3. Using references on Table 1 and measurements on page 21 center the hood in place beneath the cabinet and flush with the front of the cabinet.
4. Draw electrical wires through cabinet access opening. Refer to Figure 6.
5. From the bottom of the hood, place screw (provided) into the exact center of each knockout hole. Make sure all screws are in place before tightening screws. CAUTION:
MAKE SURE THE HOOD IS SECURE BEFORE RELEASING.
6. For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure installation, use as many mounting holes as needed to secure from the inside of hood (screws included).
Figure 1
Figure 2
Figure 3
Figure 4
7
Ductwork Installation
Wiring to Power Supply
Install Accessories
Final Assembly
7. Use 6” round steel pipe for 30” and 36” models or 8” round steel pipe for 42” and 48” models (follow building codes in your area) to connect the exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 5.
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.
8. Connect the electrical wires.
-
Connect three wires (black, white and green) to house wires and cap with wire connectors. Connect according to color: black to black, white to white, and green to green as shown on Figure 6.
-
If necessary to hide the electrical wire connections, push wires back into the wiring box. Access the wire connections underneath the hood. To prevent any damage, make sure wires do not slip between motor or any moving parts.
9. Attach Oil Tunnel. Refer to Figure 7.
10. Refer to Figure 8. Slide the baffle filter into the hood. Push the baffle filter upward. Slide forward. Pull downward. Fit into place.
11. Repeat until all baffle filters and spacers are resting against oil tunnel. Refer to page 22.
12. Turn power ON in control panel. Check all lights and fan operation.
13. Make sure to leave this manual for the homeowner.
Figure 5
Figure 6
Figure 7
Figure 8
8
Preparation before Installation
Preparation before Installation
CH00 SERIES – STAND ALONE INSTALLATION
***This installation required to have Duct Cover
Model No. CH0030DC-12 / CH0036DC-12 / CH0042DC-12 / CH0048DC-12
NOTE: TO AVOID DAMAGE TO YOUR HOOD,
PREVENT DEBRIS FROM ENTERING THE VENT OPENING.
Decide the location of the venting pipe from the hood to the outside. Refer to Figure 9.
A straight, short venting run will allow the hood to perform more efficiently.
Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood.
Temporarily wire the hood to test for proper operation before installing.
Important: Peel protective film off the hood and the duct cover (if any).
If necessary, prepare back wall frame with cross framing lumber for secure installation.
Using references on Table 2 and measurements on page 21-22, decide the level of the lumber. Refer to Figure 10.
CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE.
1. (This step only applies to 42” and 48” models.) Attach exhaust plate on hood with four (3/16” x 3/8”) screws (included). Shown in Figure 11.
2. If necessary, remove the rubber stand on the back of the hood.
3. Use twelve (3/16” x 3/8”) screws (included) to attach the two hood-mounting brackets (included) to the top of the hood.
4. Using references in Table 2 and Measurements and Diagrams on pages 21-22, mark the leveling point of the hood. Position six mounting screws (included) on the wall, leaving 1/8” away from the wall.
Figure 9
Figure 10
Figure 11
9
Loading...