Note: IR21a’s and other IR receivers are wired in parallel. Maximum 10 per system.
Note: When using more than 150 foot lengths of shielded cable (total) to connect IR receivers to the IR55, it may be necessary to add a 470 ohm 1/4 watt 5% resistor between the IR55 “GND” and “IR OUT” terminals. This resistor discharges cable capacitance.
IR21b
IR OUT
IR21b
IR OUT
Typical IR Repeater System
PS1202
Power
GND
+12VDC
GND
+12VDC
Supply
IR55
Connection
Block
+12VDC
GND
IR OUT
IR34 double emitter
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
IR31 single emitter
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
234567890123456789012345678
Satellite dish
CD Changer
Cassette deck
Note: Position and attach emitter over component IR window
IR55
Infrared Connection Module
Information and Installation Guide
v 1.2
IR55 Features
* Easy to install, easy to use! * No maintenece or adjustments *Connect up to 10 infrared receivers *Connect up to 8 emitters (four IR34 double emitters) *Connect a PS1202 or PS1205 power supply
Specifications
Infrared carrier frequency: 30-60kHz Power requirements: PS1202 200mA or PS1205 500mA unregulated 12VDC power supply Dimensions: 2-1/2” w x 1” h x 2-5/8” D (63 x 26 x 67mm). Color: Black
Installation Tips:
1. Follow all local electrical & building code requirements.
2. The IR55 is usually positioned behind the stereo components it is helping to control.
3. Connect all of the infrared receivers in parallel to the IR55 blue three terminal connector as shown in the diagram. Wires can be solid or stranded, shielded or unshielded with a minimum of 24 gauge for runs under 200’, 22 gauge for runs under 500’ and 20 gauge for runs up to 1000’. Wires can be looped from IR21a to IR21a or home run. Home runs generally offer more reliability and future flexibility.
4. Connect the emitters by inserting their plugs into any available IR55 emitter jack. Up to four single emitter or double emitters (maximum eight emitters) can be connected to a single IR55. If more emitter connections are required, call Knöll for amplified connection block information.
5. Lastly plug the PS1202 or PS1205 power supply into the IR55 and test the whole system.
Warranty
Knoll Systems warrants its products sold in the USA by authorized
Knoll Systems dealers to be free from defects in materials and workmanship. The warranty extends for two full years from the date of purchase by the original consumer. Any products returned within the warranty period will be repaired or replaced at Knoll Systems option, at no cost. Knoll Systems will not be responsible for the actual cost of removal or reinstallation of the product, nor of any incidental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you. This warranty gives you specific legal rights. You may have additional legal rights that vary from state to state.