Knoll IR220 Installation Guide

IR220 Infrared Receiver Specifications:
Specifications
Infrared carrier frequency: 30-60 kHz Indoor reception range: 25-30 feet (7-9 meters) Nominal reception angle: 50 degrees off axis Maximum wire length: 1000’ (300m) or more with larger
gauge wire
Wire requirements: 3 or 4 conductors, minimum
24-gauge to 200’; 22-gauge
up to 500’; 20-gauge to 1000’ Power requirements: Unregulated 12VDC, 40mA Dimensions:
Cord length 75” (2 meters)
Requires 12VDC power supply, emitter(s) and may require IR54, or IR55 connection block.
15/16 x 3/8 x 1/2” h
(24 x 9.5 x 13 mm h)
Warranty
Knoll Systems warrants its products sold in the USA and Canada by authorized Knoll dealers to be free of defects in materials and workmanship. This warranty extends for three full years from the date of purchase by the original consumer. Any products returned to Knoll Systems and found to be defective by Knoll Systems within the warranty period will be repaired or replaced at Knoll Systems option, at no charge. Knoll Systems will not be responsible for the actual cost of installation or removal of the product, nor for any incidental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights. You may have additional legal rights that vary from state-to-state.
Knoll Systems www.knollsystems.com
145 Tyee Drive Point Roberts, WA 98281 12140 Horseshoe Way, Richmond BC V7A 4V5 Telephone: (604) 272-4555, Fax: (604) 272-5595
Made in Canada Knoll Systems All Rights Reserved

IR220

Micro Infrared Receiver Installation Instructions v1.0
Warning: To be installed and/or used in
accordance with appropriate electrical codes and regulations.
Introduction: Thank you for your purchase of a Knoll IR220
infrared receiver. This receiver features the ability to pick up a remote control infrared signal and relay it on wires to another location up to 1000’ (or more).
Features:
Will relay almost all remote control types (except some
B & O and Elite models).
Can be connected with almost any 3 conductor wire including cat 5.
Requires very little power. Suggest using PS1202 12 VDC (200 mA) for up to 5 IR220’s.
Up to 10 or IR220’s, IR230’s and other compatible models can be connected in a single system.
Specify black, white or silver color case.
CFL ready design.
Installation Tips
1. Follow all local electrical & building code requirements.
2. The IR220 is usually mounted on the surface of a panel, door, cabinet or plate. For easy installation and to ensure reliability, it is suggested that a PS1202 (200 mA) or PS1205 (500 mA) 12 VDC unregulated power supply, IR31a (single) or IR34a (dual) emitters and one of the following: IR54 (decora inwall style, 4 output) or IR55 (tabletop style, 4 output) connection block, be used.
3. Wires can be solid or stranded, shielded or unshielded with a minimum of 28-gauge for runs under 200’, 22-gauge for runs under 500’ and 20-gauge for runs up to 1000’. Wires can be looped from IR220 to IR220 or home run. Home runs generally offer more reliability and future flexibility.
4. IR220s can be mixed and matched in larger systems with up to 10 infrared receivers, such as the Knoll IR100 or IR230.
5. Mount the IR220 using the double sided sticky tape provided. It is best to mount the IR220 where it will not get direct sunlight on it.
PS1202
12 V DC Po wer Supply
. To wire the system together, connect the IR220 12V, GND and
5 IR SIG terminals to the corresponding IR54 or IR55 terminal. Strictly observe polarity. The conductor with printing on it is the 12 V wire, the center wire is GND and the other conductor is the IR signal.
, plug the single or dual emitters into the IR54 or IR55
. Next6
connection block.
. Now, plug in the7
five to ten receivers.
. The infrared sy8
unswitched outlet) as it uses very little power.
. Test the infrared system to see if it is work9 sunlight and passive infrared security systems can lower the distance that remote controls can work with an IR220 receiver.
0. If you have any questions or concerns, please call and ask fo1 infrared technical support at 1 800 566 5579. The Help Line is ope from 7:30 a.m. to 5:00 p.m., Monday to Friday, Pacific time.
PS1202 (for up to five receivers) or PS1205 for
stem is usually left plugged in all the time (to an
ing properly. Bright
r
n
Note: IR220’s are wired in parallel
IR55
12V
GND
SI G
Connection Block
Wire with printing
Recei ver
IR31A
CD
IR34A
Di sh
IR34A
171
IR220
IR OUT Signal GROUND
+12 VDC
Wire with printing