Knightsbridge WALL2, WALL1, WALL3 Installation Instructions

INSTALLATION & MAINTENANCE MANUAL
WALL1 / WALL2 / WALL3
GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by the end user for future reference and maintenance. These instructions should be used to aid installation of the following products: WALL1 / WALL2 / WALL3
SAFETY
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
• This product is Class I and must be earthed
• This product series is IP65 rated
INSTALLATION
• Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable IP rated junction boxes should be used where required
• Using the Allen key provided, carefully loosen the three grub screws securing the baseplate to the luminaire (see Fig. 1)