INSTALLATION & MAINTENANCE MANUAL
UCLED SERIES
60

GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by the end user for future
reference and maintenance.
These should be used to aid installation of the following products:
UCLED4CW/UCLED4WW/UCLED7CW/UCLED7WW/UCLED9CW/UCLED9WW/UCLED13CW/
UCLED13WW/UCLED18CW/UCLED18WW/UCLED22CW/UCLED22WW
SAFETY
• Installation of this luminaire should only be carried out by a qualified electrician or competent
person to the current building and IEE Wiring Regulations (BS7671)
• Before installation/maintenance, ensure that all mains supply to the luminaire is switched off and
the circuit fuses are removed or switched off
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the
rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress of Protection) rating of this luminaire
when deciding the location for installation
• This product is class II double insulated
• Please recycle this unit
• This product is non-dimmable
• This product is IP20
INSTALLATION
Note - If this luminaire is being used in conjunction with external PIR or sensors, please confirm with
the manufacturer of the sensors that they are compatible with LED luminaires.
• Provide a suitable power supply to the required position of the luminaire, and then connect the
supplied mains cable with the ‘figure of 8’ connector
• Mark the location of the fixing holes for the mounting clips. The mounting clips should be spaced
so as to distribute the weight of the luminaire evenly. Drill the holes for the mounting clips (see fig
1) ensuring not to infringe with any joists, gas/water pipes or electrical cables that may be hidden
behind the surface
Note: The 4W, 7W and 9W units only require two mounting clips and the 13W, 18W and 22W versions
require three.