These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following products:
TNXQUADSTW / TNXQUADSTBK / TNXONESTW / TNXONESTBK
SAFETY
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671)
and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the
circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
• This product is Class II double insulated
• This product is IP65 rated
INSTALLATION
Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible with LED luminaires.
• Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable IP
rated junction boxes should be used where required
• Remove the diffuser from the luminaire housing by unscrewing the four screws
• Drill the fixing holes in the rear of the fitting. Mark the location of the fixing holes and drill ensuring not to
infringe with any gas/water pipes or electrical cables
• Feed the mains cable through the rubber grommet to retain IP rating, and secure the base to the surface
using the plugs and screws provided
Page 3
• Ensuring correct polarity is observed, carefully wire as shown in Fig. 1. Two cables can be inserted into
the push-fit terminal block in order to achieve loop-in/loop-out wiring. The earth terminal is non-functional
and only provided for convenience
Fig. 1
• Connect the battery to the inverter
• Choose the required driver output and colour temperature via the switches on the driver (see Fig. 2)
Fig. 2
• Attach the LED plate to the luminaire body by aligning the four butterfly screws on the body with the
corresponding holes on the plate then turn clockwise to lock into place (see Fig. 3)
Page 4
Fig. 3
• Re-attach the diffuser to the luminaire body using the four screws
• Switch on and check for correct operation ensuring the green indicator LED is illuminated
• See below for operation of the self-test function
• We recommend, on commissioning the installation, a minimum charge period of 24 hours before carrying
out an emergency duration test
SELF-TEST FUNCTION
This product is programmed to carry out its own self-test operation according to the following programme:
24 hours after first power on3-hour initial duration test
then every 28 days30-second function test
and every 52 weeks3-hour duration test
Following self-tests, the unit will revert to charging mode, and any faults will be indicated by the bi-colour LED
indicator as follows:
Page 5
LED INDICATORSTATUS
Solid greenNormal conditions, battery is charged / charging
Slow flash green (1 sec on, 1 sec off)Self-test (function or duration test) underway
Solid redBattery fault
Slow flash red (1 sec on, 1 sec off)Lamp fault
Fast flash red (0.25 sec on, 0.25 sec off)Failed duration test
To clear a fault indication, disconnect and reconnect the mains supply once the fault has been rectified.
To reset the self-test timing schedule, disconnect and reconnect the battery - disconnecting and reconnecting
the mains supply does not reset the timing schedule.
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
GENERAL
This product contains a light source of energy efficiency class D to Regulation (EU) No. 2019/2015 and (UK)
2021 No. 1095.
This product contains an LED light source which can be replaced by a professional and a control gear which can
be replaced by a professional.
Page 6
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the
product.
Do not use any source of high-pressure washers to maintain or clean this luminaire.
This product is non-dimmable.
This product should be dismantled for disposal when it reaches the end of its life. Please see website for
dismantling instructions.
This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities
for where facilities exist
The batteries in this luminaire are Lithium Ion and must be disposed of correctly. Please contact the local
authorities for the disposal of this toxic waste
WARRANTY
This product has a warranty of 5 years from date of purchase. Failure to install this product in accordance with
the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will
invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place
of purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation
costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve
the right to alter product specification without prior notice.
TESTING FOR EMERGENCY LUMINAIRES
Recommended routine test procedure in accordance with BS5266:
• Daily check – check status of bi-colour LED indicator
• Monthly functional test – the luminaire will perform this function without any action from the user.
Alternatively, simulate a mains supply failure for approx. 30 seconds by operation of key switch, or switching
off circuit breaker. Ensure normal supply is restored after test and check status of bi-colour LED indicator
• Annual 3-hour duration test – the luminaire will perform this function without any action from the user.
Page 7
Alternatively, simulate a mains supply failure for 3-hour continuous test by operation of key switch, or
switching off circuit breaker. Ensure normal supply is restored after test and check status of bi-colour LED
indicator
• If the luminaire fails any of the above tests, please contact a qualified electrician. Results should be recorded,
even when obtained via the self-test function. See below for test record sheet
Page 8
230V
50Hz
(UK) MANUFACTURER
ML ACCESSORIES LTD,
UNIT E CHILTERN PARK,
BOSCOMBE ROAD, DUNSTABLE
LU5 4LT,
WWW.MLACCESSORIES.CO.UK
IP65
SUPPLIED BY:
(EU) AUTHORISED REPRESENTATIVE
52531 ÜBACH-PALENBERG, GERMANY
-5~
°C
35
TA
02
SLV LIGHTING GROUP,
DAIMLERSTRASSE 21-23,
EMAIL: EPREL@GROUP.SLV.COM
MADE IN CHINA
AKDEC22_V1