INSTALLATION & MAINTENANCE MANUAL
T8LED SERIES
230V
IP
20
52
1

GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by the end user for future
reference and maintenance.
These instructions should be used to aid installation of the following products:
T8LED2 / T8LED4 / T8LED5 / T8LED6 / T8LED2D / T8LED4D / T8LED5D / T8LED6D
SAFETY
• Installation of this lamp should only be carried out by a qualified electrician or competent person to
the current Building and IEE Wiring Regulations (BS7671)
• Please isolate mains prior to installation/maintenance
• Check the total load on the circuit (including when this product is fitted) does not exceed the rating
of the circuit cable, fuse or circuit breaker
• This product is IP20 rated
• This product is non-dimmable
INSTALLATION
• Ensure supply voltage to the luminaire has been isolated
• Please note, this LED tube is powered from one end (see Fig 1)
(L) Live
(N) Neutral
Fig 1
• Carefully remove old tube from the fitting by rotating 90°
• Insert the MLA LED tube into the fitting and lock in position by rotating 90°
• Ensure light emission direction is correct as these lamps are directional
• If the fitting is wired as shown in Fig 2, it will not matter which way the LED tube is installed
Fig 2
Lamp holders
• Switch on power supply and check for correct operation