INSTALLATION & MAINTENANCE MANUAL
T8BLED EM SERIES
52

GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by the end user for future
reference and maintenance.
These instructions should be used to aid installation of the following products:
T8BLED15EM, T8BLED15HLEM, T8BLED16EM, T8BLED16HLEM, T8BLED25EM, T8BLED25HLEM,
T8BLED26EM, T8BLED26HLEM
SAFETY
• Installation of this luminaire should only be carried out by a qualified electrician or competent
person to the current IEE Wiring Regulations (BS7671)
• Please isolate mains prior to installation/maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the
rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for
installation
• This product is Class I and requires an earth
• This product is non-dimmable
INSTALLATION
• Provide power to the required point of installation
• Remove the end caps with the aid of a slotted screwdriver
• Remove 2 screws on top of the twin fitting (see fig 1)
End
Cap
Fig 1 Twin fitting
Remove screws
• Remove the LED plate on the single version by pinching together under the LED plate
• Slide the LED plate off on the twin version
• Mark the location of the fixing holes and drill the holes ensuring not to infringe with any joists,
gas or water pipes or electrical cables
• Bring power cable into luminaire
• Secure luminaire to ceiling
• Connect the permanent live, neutral, earth and switched live to the push fit terminals on the
terminal block (see fig 2)