Knightsbridge LED3WB, LED3WCW, LED3WWW, LED5WB, LED5WCW Installation Instructions

...
INSTALLATION & MAINTENANCE MANUAL
IP
20
LEDxxx / LEDTxxx
43
1
GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by the end user for future reference and maintenance. These instructions should be used to aid installation of the following products: LED3WB / LED3WCW / LED3WWW / LED5WB / LED5WCW / LED5WW W / LED11WB / LED11WCW / LED11WWW LEDT3WCW / LEDT3WWW / LEDT5WCW / LEDT5WWW / LEDT11WCW / LEDT11WWW
SAFETY
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for installation
• This product is Class III
• This product series is IP20 rated
• This product is dimmable with LEDDIMMER or LEDTD1* (* suitable for flat range only)
INSTALLATION
Note - If this luminaire is being used in conjunction with an external PIR or sensor, please confirm with the manufacturer
of the sensors that they are compatible with LED lamps
• Provide power to the required point of installation
• Using the clip as a template, mark the location for, and drill the fixing holes ensuring not to infringe with any gas / water pipes or electrical cables and insert the luminaire into the clips until it locks into place (see Fig.1)
Fig. 1
• Ensuring correct polarity is observed, connect the 230V mains supply to the primary side of the 24V constant voltage driver, Live (Brown), Neutral (Blue) (LEDAD36 pictured, not supplied) (see Fig. 2)