Knightsbridge LANT1, LANT1W, LANT2, LANT2W Installation Instructions

INSTALLATION & MAINTENANCE MANUAL
230V
50Hz
IP
54
LANT1x / LANT2x
02
GENERAL INSTRUCTIONS
SAFETY
• Installation of this luminaire should only be carried out by a qualified electrician or competent person to the latest Building and current IEE Wiring Regulations (BS7671)
• Please isolate mains prior to installation/maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for installation
• This product is Class II double insulated
• This product is non-dimmable
• This product is IP54 rated
INSTALLATION
• Provide power to the required point of installation. Suitable IP rated junction boxes should be used where required
• Remove the 2 nuts on the front of the fitting securing the baseplate of the luminaire
• Using the baseplate as a template mark the location of the fixing holes, and drill the holes ensuring not to infringe with any joists, gas or water pipes or electrical cables
• Feed mains cable through the rubber grommet to retain IP rating and secure baseplate to the desired surface. Carefully wire as shown in Fig 1
• Reassemble ensuring there are no trapped cables
• Switch on and check for correct operation
Neutral (blue)
Live (brown)
Fig 1