Knightsbridge FLF10RGB, FLF20RGB, FLF30RGB, FLF50RGB Installation Instructions

INSTALLATION & MAINTENANCE MANUAL
IP
65
FLFxxRGB series
113
GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by the end user for future reference and maintenance. These instructions should be used to aid installation of the following products; FLF10RGB, FLF20RGB, FLF30RGB, FLF50RGB
SAFETY
• Installation of this luminaire should only be carried out by a qualified electrician or competent person to the latest Building and current IEE Wiring Regulations (BS7671)
• Please isolate mains prior to installation/maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for installation
• This product is Class I and requires an earth
• This product is non-dimmable
• This product is IP65 rated
INSTALLATION
• Provide power to the required point of installation. Suitable IP rated junctions boxes should be used where required
• Remove the bolts either side of the base mounting bracket and remove bracket, see Fig 1
Bolt
Mounting bracket
Fig1
• Using the base mounting bracket as a template, mark the location of the fixing holes and drill the holes ensuring not to infringe with any joists, gas or water pipes or electrical cables
• Carefully wire as shown in Fig 2