These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following product:
EMPOWERSTL
SAFETY
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671)
and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the
circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
• Allow 50mm above and around the fitting for air dissipation (do not cover the fitting with insulation)
• This product is for indoor use only
• This product is Class II double insulated
• This product is IP20 rated
INSTALLATION
• Provide power to the required point of installation
• Cut a suitable hole in the mounting surface as per the cut-out details (see Fig. 1) ensuring not to infringe
with any joists, gas / water pipes or electrical cables
Page 3
INSTRUCTIONS EMPOWERST
• Connect the luminaire to the mains supply via a suitable
junction box ensuring that correct polarity is observed: Live
(brown) and Neutral (blue)
(see Fig. 2):
Fig. 1
Fig. 2
• Connect the battery pack to the inverter via the plug and socket provided, ensuring that correct polarity is
observed
• Connect the downlight to the inverter via the plug and socket provided
• Change the bezel if required, by unscrewing from the downlight and replacing with the desired bezel
• Place the inverter and battery pack into the ceiling via the cut-out
• Push up the spring clips either side of the fitting and locate into ceiling
• Switch on and check for correct operation, ensuring the green indicator LED is illuminated
Page 4
SELF-TEST FUNCTION
This product is programmed to carry out its own self-test function according to the following programme:
24 hours after first power-on 3-hour duration test
Then every 28 days 30 second monthly function test
And every 52 weeks 3-hour duration test
The downlight has one tri-colour LED which is green when charging, white when in emergency mode, and
red to indicate faults. Following self-tests, the unit will go back into charging mode, and any faults will be
indicated by the LED indicator as follows:
LED indicatorStatus
Solid greenNormal conditions / charging / test successful
1 red flashBattery fault
2 red flashesLamp fault
3 red flashesDuration test failure
NB: disconnect and restore power to the unit to clear a fault indication once the condition is rectified.
This product has no facility for initiating tests manually.
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
Page 5
GENERAL
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole
luminaire should be replaced.
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the
product.
This product is non-dimmable.
This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities
for where facilities exist.
The batteries in this luminaire are Lithium Ion and must be disposed of correctly. Please contact the local
authorities for the disposal of this toxic waste.
WARRANTY
This product has a warranty of 3 years from date of purchase. Failure to install this product in accordance with
the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch codes will
invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place
of purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation
costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve
the right to alter product specification without prior notice.
Page 6
TESTING FOR EMERGENCY LUMINAIRES
Recommended routine test procedure in accordance with BS5266:
• Daily check – check status of LED indicator
• Monthly functional test – the luminaire will perform this function without any action from the user.
Alternatively, simulate a mains supply failure for approx. 30 seconds by operation of key switch, or switching
off circuit breaker. Ensure normal supply is restored after test and check status of LED indicator
• Annual three-hour duration test – the luminaire will perform this function without any action from the user.
Alternatively, simulate a mains supply failure for three-hour continuous test by operation of key switch, or
switching off circuit breaker. Ensure normal supply is restored after test and check status of LED indicator
• If the luminaire fails any of the above tests, please contact a qualified electrician. Results should be recorded,
even when obtained via the self-test function. See below for test record sheet
Page 7
SUPPLIED BY:
ML ACCESSORIES LTD, UNIT E CHILTERN PARK, BOSCOMBE ROAD,
(UK) MANUFACTURER
DUNSTABLE LU5 4LT, WWW.MLACCESSORIES.CO.UK
(EU) AUTHORISED REPRESENTATIVE
SLV LIGHTING GROUP,
DAIMLERSTRASSE 21-23,
52531 ÜBACH-PALENBERG, GERMANY
EMAIL: EPREL@GROUP.SLV.COM
MADE IN CHINA
0~45°C
TA
54
DCJUN23_V1
Page 8
TEST RECORD SHEET
INITIAL COMMISSIONING
3 HOUR TEST
MONTHTEST
1FUNCTIONAL
2FUNCTIONAL
3FUNCTIONAL
4FUNCTIONAL
5FUNCTIONAL
6FUNCTIONAL
7FUNCTIONAL
8FUNCTIONAL
9FUNCTIONAL
10FUNCTIONAL
11FUNCTIONAL
123 HOUR
FIRST YEARSECOND YEARTHIRD YEARFOURTH YEARFIFTH YEAR
SIGNEDDATE SIGNED DATE SIGNED DATE SIGNEDDATE SIGNEDDATE
Installed by: Installation date:
Contact number:
SIGNEDDATE
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.