These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following products:
EMLED1L / EMLED3L / EMLED4L
SAFETY
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671)
and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the
circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
• This product is Class II double insulated
• This product is IP65 rated
INSTALLATION
Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible with LED luminaires.
• Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable IP
rated junction boxes should be used where required
• Unfasten the screws at each end of the product to remove the diffuser
• Release the gear tray by pushing the release tabs outwards (see Fig. 1)
Page 3
Fig. 1
• Drill the fixing holes in the rear of the fitting. Mark the location of the fixing holes and drill ensuring not to
infringe with any gas/water pipes or electrical cables
• Drill out one of the 20mm drilling guides and fit the grommet provided
• Feed the mains cable through the rubber grommet to retain IP rating, and secure the baseplate to the
surface
• Wire for non-maintained operation (Fig. 2), maintained operation (Fig. 3) or switched-maintained operation
(Fig. 4) as required. Remove the link between LS and L if not required
Page 4
Fig. 2
• Ensure the battery is connected via the plug and socket to the PCB
• Replace the gear tray and diffuser ensuring seal is in place
• Switch on and check for correct operation, ensuring the green indicator LED is illuminated
• We recommend, on commissioning the installation, a minimum charge period of 24 hours before carrying
out an emergency duration test
Page 5
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
GENERAL
Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only, do not
use aggressive cleaning products or solvents which may damage the product.
Do not use any source of high-pressure washers to maintain or clean this luminaire.
Installing in areas where the temperature consistently drops below 0°C may shorten the battery life.
This product is non-dimmable.
This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities
for where facilities exist.
The batteries in this luminaire are Lithium Ion and must be disposed of correctly. Please contact the local
authorities for the disposal of this toxic waste.
WARRANTY
This product has a warranty of 3 years from date of purchase. Failure to install this product in accordance with
the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will
invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place
of purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation
costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve
the right to alter product specification without prior notice.
Page 6
TESTING FOR EMERGENCY LUMINAIRES
Recommended routine test procedure in accordance with BS5266
• Daily check – check LED charge indicator is illuminated
• Monthly functional test - simulate a mains supply failure for approx. 30 seconds by operation of key switch
or switching off circuit breaker. Ensure normal supply is restored after test and ensure charge indicator is
illuminated
• Annual 3-hour duration test - simulate a mains supply failure for 3-hour continuous test by operation of key
switch or switching off circuit breaker. Ensure normal supply is restored after test and ensure charge indicator
is illuminated
• If the luminaire fails any of the above tests, please contact a qualified electrician. See below for test record
sheet
Page 7
SUPPLIED BY:
ML ACCESSORIES LTD, UNIT E CHILTERN PARK,
(UK) MANUFACTURER
BOSCOMBE ROAD, DUNSTABLE LU5 4LT,
WWW.MLACCESSORIES.CO.UK
(EU) AUTHORISED REPRESENTATIVE
SLV LIGHTING GROUP,
DAIMLERSTRASSE 21-23,
52531 ÜBACH-PALENBERG, GERMANY
EMAIL: EPREL@GROUP.SLV.COM
MADE IN CHINA
0~45°C
54
TA
DCJUN23_V1
Page 8
switching off circuit breaker. Ensure normal supply is restored after test and ensure charge indicator isilluminated
key switch or switching off circuit breaker. Ensure normal supply is restored after test and ensure chargeindicator is illuminated
sheet