Knick Portavo 904(X) PH Instruction Manual

User Manual
The Art of Measuring.
MEMO
SENS
orange-red ring
Betriebs-
anleitung
deutsch
MEMO
SENS
MEMO
SENS
MEMO
SENS
Pg 13.5 -Steckkopf
¡Å
English
Portavo 904(X) PH
Latest Product Information: www.knick.de
Basics
Warranty
Defects occurring within 3 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender). Sensors and accessories: 1 year Subject to change
Return of products under warranty
Please contact our Service Team before returning a defective device. Ship the cleaned device to the address you have been given. If the device has been in contact with process uids, it must be decontaminated/ disinfected before shipment. In that case, please attach a corresponding certicate, for the health and safety of our service personnel.
Disposal
Please observe the applicable local or national regulations concerning the disposal of “waste electrical and electronic equipment”.
3
Registered trademarks
The following names are registered trademarks. For practical reasons they are shown without trademark symbol in this manual.
• Calimatic®
• Memosens®
• Paraly®
• Portavo®
• Sensocheck®
• Sensoface®
4
Package Contents ............................................................................... 6
Documentation ................................................................................... 7
Overview of the Portavo 904(X) PH .................................................. 8
Value-Added Features ..............................................................................................9
Protective Cover .......................................................................................................10
Hook ............................................................................................................................. 10
Display ......................................................................................................................... 11
Keypad ........................................................................................................................12
Start-Up ............................................................................................. 13
Inserting the Batteries ........................................................................................... 13
Batteries for Application in Hazardous Locations........................................14
Connecting a Sensor .............................................................................................. 15
Switching On the Meter ........................................................................................ 16
Icons ............................................................................................................................. 16
Conguring .......................................................................................17
Table of Contents
Calibrating ........................................................................................18
Measuring .........................................................................................22
Switching the Measured Value Display ........................................................... 22
Data Logger ......................................................................................23
Operating Modes of the Data Logger (Logger Type) ................................. 24
Data Logger Menu .................................................................................................. 26
Conguring the Data Logger .............................................................................. 27
Starting the Data Logger using CONT ............................................................. 28
Starting the Data Logger using START ............................................................28
Displaying the Logger Data ................................................................................. 29
Stopping the Data Logger ...................................................................................30
Clearing the Data Logger ..................................................................................... 30
Clock ..................................................................................................31
Table of Contents
Paraly SW 112 Software ..................................................................32
Error Codes and Device Messages ................................................... 33
“Sensoface” Messages ............................................................................................ 34
Error Messages ......................................................................................................... 35
Product Line ...................................................................................... 36
Accessories ................................................................................................................36
Sensors ........................................................................................................................ 37
Knick CaliMat Buer Solutions ...........................................................................38
Specications .................................................................................... 39
Index .................................................................................................. 43
5
6
Check the shipment for transport damage and completeness. The package of the Portavo 904(X) PH includes:
• The Portavo 904(X) PH incl. 4 AA batteries and premounted quiver
• Carrying strap
• Quickstart instructions in various languages
• Specic test report
• Safety instructions
• Certicates
• Data carrier with detailed user manuals and Paraly SW 112 software
• USB cable, 1.5 m

Package Contents

Documentation

Specic Test Report
CD-ROM
Complete documentation:
• User manuals in dierent languages
• Safety Information
• Certicates
• Quickstart guides
Safety Instructions
In ocial EU languages and others.
• EC Declarations of Conformity
7
Certicates
• IECEx
• ATEX
Quickstart Guides
Installation and rst steps:
• Operation
• Menu structure
• Calibration
• Error messages and recommended actions
Various languages on CD-ROM and on our website: www.knick.de
8

Overview of the Portavo 904(X) PH

The Portavo 904(X) PH is a portable
pH meter. A plain-text line on the high­contrast LCD screen makes operation vir­tually self-explanatory. The device variant 904 XPH is available for applications in hazardous locations up to Zone0. The meter stands out by the following features:
• Use of digital Memosens sensors
• Memosens sensors and DIN pH sensors can be used on one device.
• A detachable quiver protects the sensor and prevents it from drying out. Further-
Quiver
more, it can be used for calibration.
• The rugged housing is made of a high-performance polymer. It provides high impact resistance and dimensional stability even when exposed to extreme moisture.
• Scratch-proof clear glass display, perfectly readable even after years
• Very long operating times with one set of batteries (4 x AA) or use of a Li-ion battery for reliable operation even at high or very low operating temperatures (Li-ion battery not suited for Portavo 904 X PH for application in a hazardous location)
• Data logger with 5000 values
• Micro USB port for communication with Paraly SW 112 software for data evaluation of digital sensors (Memosens)
• Sensoface icons provide single-glance information on the sensor condition (page 34)
• Calibration with “Calimatic” automatic buer recognition (page 18)
• Manual calibration by entering individual buer values
• Real-time clock and indication of battery charging level
• At measuring temperatures from -20 to +100 °C the temperature detector can be automatically identied.
Overview of the Portavo 904(X) PH

Value-Added Features

Memosens
The Portavo 904 can communicate with Memosens sensors. When these digital sensors are connected to the meter, they are automatically identied and indicated by the logo shown on the right. Furthermore, Memosens allows the storage of calibration data, which will be available and can still be used when the sensor is connected to another Memosens-capable device.
Sensoface
Sensoface provides quick information on the sen­sor condition. The three “smiley” faces as shown on the right represent the sensor condition during measurement and after a calibration. When the condition deteriorates, an INFO …” message gives a hint to the cause.
9
Automatic calibration with Calimatic
Calimatic is a very convenient method for pH calibration with automatic buer recognition. You only have to select the buer set with the buers used. The buers can then be used in any order. As delivered, this calibration method is preset. It can be adjusted or disabled in the conguration menu.
10
Overview of the Portavo 904(X) PH

Protective Cover

The front of the meter is protected by a cover, which can be completely ipped over and secured to the back for oper­ation. A label on the inner side of the cover explains the control functions and device messages.

Hook

A fold-out hook on the back allows suspending the meter. This leaves your hands free for the actual measurement. The rating plate is located beneath the hook.
Protective Cover and Hook Combined
Cover and hook can be joined together to form a benchtop stand allowing com­fortable and fatigue-free working at a lab bench or desk.
Overview of the Portavo 904(X) PH

Display

The meter has a three-line display for representing alphanumeric informa­tion such as measurement and calibra­tion data, temperatures and date/time. Additional information is provided by means of icons (Sensoface, battery icon, etc.). Some typical displays are shown here.
Measuring (display of measured value, temperature, date and time)
11
Calibration – step 1
Logger data (display of measured value, memory location, temperature, date and time)
End of calibration (display of slope)
Clock (display of hours and minutes, seconds and date).
12
Overview of the Portavo 904(X) PH

Keypad

The keys of the membrane keypad have a noticeable pressure point.
They have the following functions:
on/o Switches the meter on and
displays the device and calibration data (see Start-Up)
meas Switches the meter on /
Activates measuring mode / Stops the data logger
cal Starts calibration
set Activates conguration /
Conrms entries
clock Displays time and date, allows
setting the clock using set
RCL View stored values
STO Holds and saves a measured
value, allows setting and starting the logger by pressing set (page 23)
▲ ▼
When this icon is displayed, you can use the arrow keys for navigation.

Start-Up

Check the shipment for transport damage and completeness (see Package Contents).
Caution!
Do not operate the device when one of the following conditions applies:
• the device shows visible damage
• the device fails to perform the intended function
• prolonged storage at temperatures above 70 °C
• severe transport stresses In this case, a professional routine test must be performed. This test should be carried out by the manufacturer.
Precautions for application in hazardous locations
Warning!
• Only open the battery compartment of the Portavo 90n X outside the hazardous location.
• Never try to open the device. If a repair should be required, return the device to our factory.
• Never use the USB port within the hazardous location.
13

Inserting the Batteries

With four AA batteries, the Portavo has an operating time of over 1000h. Open the battery compartment on the rear of the device. Be sure to observe the correct polarity when inserting the batter­ies (see markings in the battery chamber). Close the battery compartment cover and screw it handtight.
A special lithium-ion battery suited to the battery compartment is available for the Portavo 904. The battery is recharged through the USB port. Note: Not available for the Portavo 904 X (device variant for applications in hazard­ous locations).
14
A battery icon in the display indicates the battery power level:
Icon fully lled Batteries at full capacity
Icon partially lled Battery capacity is sucient
Icon empty Battery capacity not sucient;
calibration is possible, no logging
Icon blinks Max. 10 operating hours remaining,
measurement is still possible Caution! It is absolutely necessary to replace the batteries.
Warning!
When using the Portavo 904 X (device variant for applications in hazardous locations) in a hazardous location, only the battery types listed below may be used. The batteries must be from the same man­ufacturer and of identical type and capacity. Never use new and used batteries together (see also Control Drawing 209.009-110).
Start-Up

Batteries for Application in Hazardous Locations

Batteries (4x each) Temp. class Ambient temperature range
Duracell MN1500 T4 -10 °C ≤ Ta ≤ +40 °C
Energizer E91 T3 -10 °C ≤ Ta ≤ +50 °C
Power One 4106 T3 -10 °C ≤ Ta ≤ +50 °C
Panasonic Pro Power LR6 T3 -10 °C ≤ Ta ≤ +50 °C
Start-Up
15

Connecting a Sensor

The Portavo 904(X) PH provides several connections so that many types of sensors can be used for measurement. Note that only one sensor may be connected to the meter at a time. The meter automatically recognizes a connected Memosens sensor and switches accordingly. Memosens is signaled in the display.
Caution!
Always make sure that a sensor is connected to the meter before starting measurement. Explanation: The analog pH input of the Portavo is an electrometer amplier with an extremely high-impedance. When the sensor is not in contact with the medium or not connected to the meter, electric charges on the input can generate arbitrary, stable pH or mV values which will be shown in the display.
Connections
a - Micro USB port b - M8, 4 pins for Memosens sensors c - Temperature probe GND d - Temperature probe e - pH socket (DIN 19 262)
Memosens sensors have a cable coupling, which allows convenient replacement of sensors while the cable remains connected to the meter. The connecting cable is connected to socket b (M8, 4 pins for Memosens sensors).
16

Switching On the Meter

When you have connected the sensor, you can switch the meter on by pressing the on/o or meas key. When the meter is switched on with the on/o key, rst a self test is performed and then the calibration data and settings are displayed before the meter switches to measuring mode. When the meter is switched on with the meas key, it immediately switches to measuring mode. Depending on the connected sensor and the specic measuring task, several steps for conguration and calibration must be per­formed as described on the following pages.

Icons

Important information about the state of the device:
Start-Up
Sensor condition
Process variable
Error message
active
Memosens sensor
Date Logger
Battery
charging level
Temperature
detection
(sensor,
separate or
manual)
Time
Loading...