KMD-1183 NetSensor Operator’s Guide
Operating Instructions
Introduction
A KMD-1183 NetSensor is a temperature/humiditysensing, wall-mounted, operator interface
for controlling a heating, ventilation, and air
conditioning (HVAC) system using KMC direct
digital controls. The NetSensor includes nine buons
(see illustration) that are described here along with
basic operation.
1
2
3
4
Raise or lower the temperature setpoint
To adjust the room temperature, press the Mode
buon to cycle to Cooling Setpoint or Heating
Setpoint mode (or ip open the cover and press the
desired buon) and use the up/down arrow buons
to adjust the setpoint to the desired seing.
Override unoccupied temperature setback/setup
To restore normal room temperature during a
scheduled unoccupied period, press the Mode
buon to cycle to Override mode (or ip open the
cover and press the Override buon) and use the
up/down arrow buons to turn On or O.
Check the humidity
Humidity is continuously displayed as xx% RH in
the middle right-hand side of the screen. To display
humidity on the top primary display, ip open the
cover and press the Humidity buon.
Check (and set) system time or day of week
System time is continuously displayed in the lower
right-hand side of the screen. To display the system
time or day of week on the top primary display,
ip open the cover and press the desired buon. If
the system is a stand-alone unit (not networked),
the time and day can also be adjusted by using the
up/down arrow buons (note AM/PM designators).
For Day of Week, simultaneously press Time and
Humidity buons (on the display, 1 = Sun., 2 = Mon.,
3 = Tue., 4 = Wed., 5 = Thur., 6 = Fri., and 7 = Sat.).
Check the system failure alarm
If a failure is detected in the HVAC system, the
controller will shut down the system. If the HVAC
system does not seem to be operating, press the
Alarm buon. If On is displayed, the HVAC system
requires servicing.
Specifications and design subject to change without notice.
5
6
Button Descriptions
The up and down arrow buons are used for raising
or lowering a value, such as temperature setpoint.
The other buons are described below:
Mode—cycles between display/set options for
1.
room temperature, cooling setpoint, heating
setpoint, and override. (The mode returns to
default room temperature display about ten
seconds aer the last buon press.)
Cooling Setpoint—displays the cooling
2.
operation setpoint value.
Heating Setpoint—displays the heating
3.
operation setpoint value.
Override—displays manual override status
4.
during scheduled unoccupied periods of
temperature setback/setup.
*Time—displays system time.
5.
Alarm—displays system failure alarm status.
6.
Humidity—displays room relative humidity.
7.
*Day of Week (press Time and Humidity
8.
buons together)—displays system day of
the week in a numeric mode, with 1 = Sunday
and 7 = Saturday.
*In a networked system, users can only view the day
and time. In stand-alone systems, users can also adjust
the day and time seings.